Maxim MAX6713MEXS-T10, MAX6713LEXS-T, MAX6713LEXS-T10, MAX6712TEXS-T, MAX6712TEXS-T10 Datasheet

...
General Description
The MAX6711/MAX6712/MAX6713 are microprocessor (µP) supervisory circuits used to monitor the power supplies in µP and digital systems. They provide excel­lent circuit reliability and low cost by eliminating exter­nal components and adjustments when used with +5.0V, +3.3V, +3.0V, or +2.5V-powered circuits. They also provide a debounced manual reset input.
These circuits assert a reset signal whenever the V
CC
supply voltage declines below a preset threshold or whenever manual reset is asserted. Reset remains asserted for at least 140ms after VCChas risen above the reset threshold or when manual reset is deasserted. Reset thresholds suitable for operation with a variety of supply voltages are available.
The MAX6713 has an open-drain output stage, while the MAX6711/MAX6712 have push-pull outputs. The MAX6713’s open-drain RESET output requires a pull-up resistor that can be connected to a voltage higher than VCC. The MAX6711/MAX6713 have an active-low reset output, while the MAX6712 has an active-high reset out­put. The reset comparator is designed to ignore fast transients on VCC, and the outputs are guaranteed to be in the correct logic state for VCCdown to 1V.
Low supply current makes the MAX6711/MAX6712/ MAX6713 ideal for use in portable equipment. These devices are available in a 4-pin SC70 package.
Applications
Computers Controllers Intelligent Instruments Critical µP and µC Power Monitoring Portable/Battery-Powered Equipment Automotive
____________________________Features
Precision Monitoring of 2.5V, 3.0V, 3.3V, and 5.0V
Power-Supply Voltages
Fully Specified Over TemperatureAvailable in Three Output Configurations
Push-Pull RESET Output (MAX6711) Push-Pull RESET Output (MAX6712) Open-Drain RESET Output (MAX6713)
140ms min Power-On Reset Pulse WidthManual Reset Input12µA Supply CurrentGuaranteed Reset Valid to VCC= +1V ♦ Power-Supply Transient ImmunityNo External Components4-Pin SC70 Package
MAX6711L/M/R/S/T/Z, MAX6712L/M/R/S/T/Z, MAX6713L/M/R/S/T/Z
4-Pin SC70 Microprocessor Reset Circuits
with Manual Reset Input
________________________________________________________________ Maxim Integrated Products 1
19-1623; Rev 0; 1/00
Note: These parts are offered in 2.5k or 10k reels and must be ordered in 2.5k or 10k increments. Order MAX6711_EXS-T for
2.5k reels and MAX6711_EXS-T10 for 10k reels. Insert the desired suffix letter from the Selector Guide into the blank to complete the part number.
For free samples and the latest literature: www.maxim-ic.com, or phone 1-800-998-8800. For small orders, phone 1-800-835-8769.
4 SC70-4-40°C to +125°C
MAX6711_EXS-T10
4 SC70-4
PIN-PACKAGETEMP. RANGE
-40°C to +125°C
MAX6711_EXS-T
PART
4 SC70-4-40°C to +125°C
MAX6712_EXS-T10
4 SC70-4-40°C to +125°C
MAX6712_EXS-T
4 SC70-4-40°C to +125°C
MAX6713_EXS-T10
4 SC70-4-40°C to +125°C
MAX6713_EXS-T
Ordering Information
TOP VIEW
RESET (RESET)
1
GND
V
CC
MAX6711 MAX6712 MAX6713
SC70-4
2
4
MR
3
( ) ARE FOR MAX6712.
MAX6711 MAX6713
V
CC
V
CC
R
PULL-UP
*
RESET
RESET INPUT
GND
MR
V
CC
GND
*MAX6713 ONLY
PUSHBUTTON SWITCH
µP
Pin ConfigurationTypical Operating Circuit
Selector Guide appears at end of data sheet.
MAX6711L/M/R/S/T/Z, MAX6712L/M/R/S/T/Z, MAX6713L/M/R/S/T/Z
4-Pin SC70 Microprocessor Reset Circuits with Manual Reset Input
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(VCC= full range, TA= -40°C to +125°C, unless otherwise noted. Typical values are at VCC= +5V for L/M versions, VCC= +3.3V for T/S versions, V
CC
= +3V for R version, VCC= +2.5V for Z version, and TA= +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Terminal Voltage (with respect to GND)
VCC........................................................................-0.3V to +6.0V
RESET, RESET (push-pull).........................-0.3V to (V
CC
+ 0.3V)
RESET (open drain)...............................................-0.3V to +6.0V
MR ..............................................................-0.3V to (V
CC
+ 0.3V)
Input Current, V
CC
, MR.......................................................20mA
Output Current, RESET, RESET ..........................................20mA
Rate of Rise, V
CC
............................................................100V/µs
Continuous Power Dissipation (TA= +70°C)
4-Pin SC70 (derate 3.1mW/°C above +70°C)..............245mW
Operating Temperature Range .........................-40°C to +125°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
100 640
TA= +85°C to +125°C
TA= -40°C to +125°C
TA= 0°C to +70°C
TA= +85°C to +125°C
TA= -40°C to +85°C
MAX671_L
CONDITIONS
2.22 2.42
4.50 4.75
V
4.56 4.63 4.70
V
TH
Reset Threshold
1.2 5.5
V
1.0 5.5
VCCRange
60
60
12 30
16 35
I
CC
Supply Current
VCC< 5.5V, MAX671_L/M
VCC< 3.6V, MAX671_R/S/T/Z
UNITSMIN TYP MAXSYMBOLPARAMETER
VCC< 5.5V, MAX671_L/M
MAX671_R
2.59 2.63 2.66TA= +25°C
VCC< 3.6V, MAX671_R/S/T/Z
TA= +25°C
TA= -40°C to +85°C
MAX671_M
4.25 4.50
2.55 2.70TA= -40°C to +85°C
MAX671_Z
2.25 2.38
2.28 2.32 2.35
2.52 2.74TA= +85°C to +125°C
TA= +25°C
TA= -40°C to +85°C
4.31 4.38 4.45
4.44 4.82TA= +85°C to +125°C
TA= +25°C
TA= -40°C to +85°C
MAX671_T
3.04 3.08 3.11
4.20 4.56TA= +85°C to +125°C
TA= +25°C
3.00 3.15TA= -40°C to +85°C
2.95 3.21TA= +85°C to +125°C
MAX671_S
2.81 3.05
2.85 3.00
2.89 2.93 2.96TA= +25°C
TA= -40°C to +85°C
TA= +85°C to +125°C
TA= +85°C to +125°C
µA
Reset Threshold Tempco
ms
µs
ppm/°C
140 240 460
20
30
TA= -40°C to +85°C
VCC= VTHto (VTH- 100mV)
Reset Active Timeout Period
VCCto Reset Delay (Note 2)
MAX6711L/M/R/S/T/Z, MAX6712L/M/R/S/T/Z, MAX6713L/M/R/S/T/Z
4-Pin SC70 Microprocessor Reset Circuits
with Manual Reset Input
_______________________________________________________________________________________ 3
Note 1: Production testing done at TA= +25°C; limits over temperature guaranteed by design only. Note 2: RESET output for MAX6711/MAX6713; RESET output for MAX6712.
CONDITIONS UNITSMIN TYP MAXSYMBOLPARAMETER
VCC= VTHmax, I
SINK
= 3.2mA,
MAX6712L/M
VCC= VTHmax, I
SINK
= 1.2mA,
MAX6712R/S/T/Z
VCC> VTHmax, I
SOURCE
= 800µA,
MAX6711L/M
V
CC
> VTHmax, I
SOURCE
= 500µA,
MAX6711R/S/T/Z
VCC= VTHmin, I
SINK
= 1.2mA,
MAX6711R/S/T/Z, MAX6713R/S/T/Z
VCC= VTHmin, I
SINK
= 3.2mA,
MAX6711L/M, MAX6713L/M
VCC> VTH, RESET deasserted
VCC> 1.0V, I
SINK
= 50µA
1.8V < VCC< VTHmin, I
SOURCE
= 150µA
µA1
RESET Open-Drain Output Leakage Current
V
0.8 · V
CC
V
OH
RESET Output Voltage High (MAX6712)
0.4
V
0.3
V
OL
RESET Output Voltage Low (MAX6712)
0.8 · V
CC
V
0.8 · V
CC
V
OH
RESET Output Voltage High (MAX6711)
V
0.3
V
OL
RESET Output Voltage Low (MAX6711/MAX6713)
0.4
0.3
V
0.3 · V
CC
V
IL
MR Input Threshold
V
IH
0.7 · V
CC
k10 20
MR Pull-Up Resistance
1
MR Minimum Pulse Width
µs
ns100
MR Glitch Immunity
200
MR to Reset Delay
ns
ELECTRICAL CHARACTERISTICS (continued)
(VCC= full range, TA= -40°C to +125°C, unless otherwise noted. Typical values are at VCC= +5V for L/M versions, VCC= +3.3V for T/S versions, V
CC
= +3V for R version, VCC= +2.5V for Z version, and TA= +25°C.) (Note 1)