MAXIM MAX6662 User Manual

General Description
The MAX6662 is a 12-bit + sign temperature sensor combined with a programmable overtemperature alarm and a 3-wire (SPI™-compatible) serial interface in a sin­gle package. It converts its die temperature into digital values using an internal analog-to-digital converter (ADC). The temperature data is stored in a temperature register as a 13-bit word, which allows 0.0625°C resolu­tion. The temperature data is readable at any time through the serial interface. The operating temperature range is -55°C to +150°C.
The MAX6662 provides two programmable watchdog interrupt outputs. ALERT is used for lower temperature warning functions, while OT is used for higher tempera­ture-critical functions, such as power-supply shutdown. The MAX6662 features a shutdown mode that saves power by disabling everything except the serial inter­face. The temperature sensor is available in an 8-pin SO package.
Applications
HVAC
Refrigeration
Automotive
Test Equipment
Features
12-Bit + Sign, 0.0625°C Resolution
Accuracy
±1°C max (+30°C to +50°C) ±1.6°C max (0°C to +70°C) ±2.5°C max (-20°C to +85°C) ±2.5 typ (+150°C)
Extended Temperature Measurement Range
-55°C to +150°C
Low Average Supply Current, 125μA (typ)
Shutdown Mode to Minimize Power Consumption
in Portable Applications
Two Programmable Temperature Fault Outputs
Switchable Fault Queue to Eliminate False
Tripping in Noisy Environments
MAX6662
12-Bit + Sign Temperature Sensor with
SPI-Compatible Serial Interface
________________________________________________________________
Maxim Integrated Products
1
ALERT
OTGND
1
2
87V
CC
NCCS
SIO
SCLK
SO
TOP VIEW
3
4
6
5
MAX6662
Pin Configuration
Ordering Information
10kΩ
10kΩ
0.1μF
V
CC
OT
ALERT
SIO
SCLK
CS
SYSTEM
CONTROLLER
V
CC
= +3V TO +5.5V
HEAT
SOURCES
MAX6662
Typical Operating Circuit
19-2121; Rev 0; 7/01
EVALUATION KIT
AVAILABLE
SPI is a trademark of Motorola, Inc.
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
PART TEMP. RANGE PIN-PACKAGE
MAX6662MSA -55°C to +150°C 8 SO
MAX6662
12-Bit + Sign Temperature Sensor with SPI-Compatible Serial Interface
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(VCC= +3V to +5.5V, TA= -55°C to +125°C, unless otherwise noted. Typical values are at TA= +25°C and VCC= +3.3V.)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
All Voltages Are Referenced to GND V
CC
...........................................................................-0.3V to +6V
ALERT, OT................................................................-0.3V to +6V
SIO, SCLK, CS............................................-0.3V to (V
CC
+ 0.3V)
SIO Current .......................................................-10mA to +50mA
Continuous Current into Any Pin (except NC)….................10mA
Continuous Power Dissipation (T
A
= +70°C)
8-Pin SO (derate 5.9mW/°C above +70°C)..................471mW
Operating Temperature Range (Note 1) ..........-55°C to +150°C
Junction Temperature......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Note 1: The MAX6662 is not recommended to operate above +125°C for an extended period of time.
TEMPERATURE TO DIGITAL-CONVERTER CHARACTERISTICS
Accuracy
Power-Supply Rejection Ratio PSRR 0.2 0.5 °C/V
Resolution 0.0625 °C
Supply Voltage Range V
Average Operating Current
Peak Operating Current (Note 2)
Shutdown Supply Current
Power-On-Reset Threshold V
Power-On-Reset Threshold Hysteresis
Conversion Time t
Temperature Update Frequency 2Hz
SERIAL INTERFACE (SIO, SCLK, CS, ALERT, OT)
Input Low Voltage V
Input High Voltage V
Input/Output Leakage Current I
Input Capacitance C
Output Low Sink Current I
Output High Voltage V
Output Low Voltage V
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
+30°C TA +50°C, VCC = +3.3V -1.0 ±0.4 +1.0
0°C TA +70°C, VCC = +3.3V -1.6 ±0.7 +1.6
-20°C TA +85°C, VCC = +3.3V -2.5 ±1.0 +2.5
CC
POR
CONV
IL
IH
LEAK
in
OL
OH
OL
-40°C TA +100°C, V
-55°C TA +125°C, V
TA +150°C, VCC = +3.3V ±2.5
VCC = +5.5V 150
= +3.0V 125
V
CC
VCC = +5.5V 300 600
= +3.0V 300 500
V
CC
VCC = +5.5V 8 22
V
= +3.0V 4 15
CC
VIN = GND or V
ALERT, OT, VOL = 0.6V 3 mA
I
= 1.6mA source V
SIO
I
= 1.6mA sink 0.4 V
SIO
CC
= +3.3V -3.0 ±1.2 +3.0
CC
= +3.3V -4.0 ±1.5 +4.0
CC
3.0 5.5 V
2.0 2.5 V
90 mV
0.25 s
0.8 V
0.7 V
CC
-5 +5 µA
5pF
- 0.4 V
C C
°C
µA
µA
µA
V
MAX6662
12-Bit + Sign Temperature Sensor with
SPI-Compatible Serial Interface
_______________________________________________________________________________________
3
Typical Operating Characteristics
(VCC= +3V, TA = +25°C, unless otherwise noted.)
ELECTRICAL CHARACTERISTICS (continued)
(VCC= +3V to +5.5V, TA= -55°C to +125°C, unless otherwise noted. Typical values are at TA= +25°C and VCC= +3.3V.)
Note 2: Peak operating current measured during conversion.
SERIAL INTERFACE TIMING
Serial Clock Frequency f
SCLK High Pulse Width t
SCLK Low Pulse Width t CS High Pulse Width t
SCLK Fall to Output Data Valid t
CS Fall to SCLK Rise t CS Rise to Output Disable t CS to SCLK Hold Time t
SIO to SCLK Setup Time t
SIO to SCLK Hold Time t
Output Fall Time t
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
SCLK
CH
CL
CSW
DO
CSS
TR
CSH
DS
DH
F
200 ns
200 ns
200 ns
C
= 100pF 100 ns
LOAD
100 ns
C
= 100pF 100 ns
LOAD
0ns
100 ns
0ns
10 ns
2.5 MHz
TEMPERATURE ERROR
VS. TEMPERATURE
3
2
1
0
-1
TEMPERATURE ERROR (°C)
-2
-3
-50 3010-30 -10 50 70 90 110 130 150
VCC = +3.0V
VCC = +5.0V
TEMPERATURE (°C)
VCC = +3.3V
MAX6662 toc01
PERCENTAGE OF SAMPLES (%)
TEMPERATURE ERROR DISTRIBTUTION
90
NOTE: DEVICES
80
TRIMMED AT
= +30°C
T
A
70
60
50
40
30
20
10
0
-0.45-0.35 -0.25-0.15 0.05 0.15 0.25 0.35 0.45 TEMPERATURE ERROR (°C)
200 SAMPLES
= +30°C
T
A
SUPPLY CURRENT VS. TEMPERATURE
200
AVERAGE OVER 2
MAX6662 toc02
180
VCC = +5.0V
160
140
SUPPLY CURRENT (μA)
120
VCC = +3.0V
100
-50 500 100 150 TEMPERATURE (°C)
MAX6662 toc03
VCC = +3.3V
Loading...