MAX6361/MAX6363/MAX6364
SOT23, Low-Power µP Supervisory Circuits
with Battery Backup
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(VCC= +2.4V to +5.5V, V
BATT
= 3V, TA= -40°C to +85°C, reset not asserted, typical values are at TA= +25°C, unless otherwise
noted.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Terminal Voltages (with respect to GND)
VCC, BATT, OUT...................................................-0.3V to +6V
RESET (open drain)..............................................-0.3V to +6V
BATT ON, MR, RESET IN .....................-0.3V to (V
OUT
+ 0.3V)
RESET, RESET......................................-0.3V to (V
OUT
+ 0.3V)
Input Current
V
CC
Peak ............................................................................1A
V
CC
Continuous ............................................................250mA
BATT Peak ....................................................................250mA
BATT Continuous ............................................................40mA
GND ................................................................................75mA
Output Current
OUT................................Short-Circuit Protection for up to 10s
RESET, RESET, BATT ON ..............................................20mA
Continuous Power Dissipation (T
A
= +70°C)
6-Pin SOT23 (derate 8.70mW/°C above +70°C) .........696mW
Operating Temperature Range
MAX636_ .........................................................-40°C to +85°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
V
0 5.5
No load (Note 2)
VCC,
V
BATT
Operating Voltage Range,
VCCor V
BATT
Supply Current
(excluding I
OUT
)
I
CC
No load, VCC> V
TH
VCC= 2.8V
VCC= 3.6V
VCC= 5.5V
10 30
11 35
15 50
µA
µA
1
3
TA= +25°C
TA= -40°C to +85°C
V
BATT
= 2.8V,
VCC= 0
I
SUPPLY
I
SUPPLY
in Battery-Backup
Mode (excluding I
OUT
)
BATT Standby Current I
BATT
5.5V > VCC>
(V
BATT
+ 0.2V)
TA= +25°C
TA= -40°C to +85°C
-0.1 0.02
-1.0 0.02
µA
Ω
1.25
2.25
4.6
VCC= 4.75V, I
OUT
≤ 150mA
VCC= 3.15V, I
OUT
≤ 65mA
VCC= 2.38V, I
OUT
≤ 25mA
R
ON
VCCto OUT On-Resistance
V
OUT
in Battery-Backup Mode
Battery-Switchover Threshold
(VCC- V
BATT
)
Reset Threshold
VCCFalling Reset Delay
Reset-Active Timeout Period t
RP
V
TH
V
BATT
= 4.5V, I
OUT
≤ 20mA
V
BATT
= 3.0V, I
OUT
≤ 10mA
V
BATT
= 2.25V, I
OUT
≤ 5mA
V
CC
< V
TH
MAX636_UT46
VCCfalling at 10V/ms
V
BATT
- 0.2
V
BATT
- 0.15
V
BATT
- 0.15
20
-20
4.50 4.63 4.75
4.25 4.38 4.50
3.00 3.08 3.15
2.85 2.93 3.00
2.55 2.63 2.70
2.25 2.32 2.38
35
150 280
ms
µs
V
mV
V
Power-up
Power-down
MAX636_UT23
MAX636_UT26
MAX636_UT29
MAX636_UT31
MAX636_UT44