MAX4372T/F/H
Low-Cost, SOT23, Micropower, High-Side
Current-Sense Amplifier with Voltage Output
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
RS+
= 0 to +28V, VCC= +2.7V to +28V, V
SENSE
= 0, R
LOAD
= 1MΩ, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are
at T
A
= +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
VCC, RS+, RS- to GND ...........................................-0.3V to +30V
OUT to GND ...........................................................-0.3V to +15V
Differential Input Voltage (V
RS+
- V
RS-
) ..............................±0.3V
Current into Any Pin..........................................................±10mA
Continuous Power Dissipation (T
A
= +70°C)
5-Pin SOT23 (derate 7.1mW/°C above +70°C).............571mW
8-Pin SO (derate 5.88mW/°C above +70°C).................471mW
Operating Temperature Range ...........................-40°C to +85°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10sec). ............................+300°C
VCC= 2.7V, I
OUT
= -500µA
VCC= 2.7V
V
RS+
≤ 2V
V
RS+
> 2V
V
RS+
≤ 2V
V
RS+
> 2V
V
RS+
> 2V
V
RS+
> 2V, V
SENSE
= 5mV
Gain = +100V/V
VCC= 0
Gain = +20V/V or +50V/V
CONDITIONS
V0.1 0.25VCC- V
OH
OUT High Voltage
965
OUT Low Voltage mV
2.6
mV
100
V
SENSE
150
Full-Scale Sense Voltage
(Note 4)
V028V
CMR
Common-Mode Input Range
(Note 3)
V2.7 28V
CC
Operating Voltage Range
(Note 2)
µA
-50 2
I
RS-
Input Bias Current
02
-25 2
I
RS+
01
dB85CMRCommon-Mode Rejection
µA30 60I
CC
Supply Current
µA0.05 1.2I
RS+
, I
RS-
Leakage Current
UNITSMIN TYP MAXSYMBOLPARAMETER
I
OUT
= 10µA
I
OUT
= 100µA
V
SENSE
= 100mV, VCC= 12V,
V
RS+
= 12V, TA= +25°C (Note 6)
%±0.18 ±3
Full-Scale Accuracy
(Note 5)
V
SENSE
= 100mV, VCC= 12V,
V
RS+
= 12V (Note 6)
±6
V
SENSE
= 100mV, VCC= 28V,
V
RS+
= 28V (Note 6)
±0.15 ±7
V
SENSE
= 100mV, VCC= 12V,
V
RS+
= 0.1V (Note 6)
±1 ±28
V
SENSE
= 6.25mV, VCC= 12V,
V
RS+
= 12V (Note 7)
%
±0.15
Total OUT Voltage Error
(Note 5)