Maxfor MFG-G400 User Manual

MAXFOR Technology Inc.
MQEP-22-04 ( 1 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
Smart Gateway
(MFG-G400)
User’s Manual
MAXFOR Technology Inc.
MAXFOR Technology Inc.
MQEP-22-04 ( 2 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
CONTENTS
1. Symbol Description and Definition ................................................................................................................ 3
2. Notice ............................................................................................................................................................................. 4
3. Introduction ................................................................................................................................................................. 5
4. Features ......................................................................................................................................................................... 5
5. Specification ................................................................................................................................................................ 5
6. Designation .................................................................................................................................................................. 7
7. Remote access method to MFG-G400 .......................................................................................................... 8
7.1 Access method to VNC Viewer ..................................................................................................................... 8
8. Installation ................................................................................................................................................................... 9
9. Maintenance ................................................................................................................................................................ 9
10. Contact information ............................................................................................................................................ 9
MAXFOR Technology Inc.
MQEP-22-04 ( 3 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
1. Symbol Description and Definition
WARNING
Warning messages address situations that could result in injury or critical damage to the Gateway.
CAUTION
Caution messages address situations that could result in damage to the Gateway.
NOTE
Notes relate helpful information.
DC Symbol
Indicates the DC power.
MAXFOR Technology Inc.
MQEP-22-04 ( 4 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
2. Notice
Important matter
▷The following document is not contractually binding. MAXFOR Technology Inc. reserves the rights to
revise the document at any point, following the any potential successful upgrade of the product;
▷First-time user, or whomever responsible for the repairing of the product, must read this manual
thoroughly before operation.
▷For the product to perform at its best, repairing or maintenance must be under the directives of
personnel of, or those appointed by MAXFOR Technology Inc.
Limitation of Liability
▷MAXFOR Technology Inc. will not be held responsible for any damages such as physical damages
occurred on users, if the cause is the inappropriate use of the product against the manual description.
▷MAXFOR Technology Inc. does not appoint any agency or men, the legal rights to represent the
company regarding our business.
▷ MAXFOR Technology Inc. will not be held responsible for damages or legal prosecution, caused by
sales or se of products not approved by us.
WARNING
Use provided adaptor. When using other adaptors, make sure to use proper rating
and standard product. It may causes damage the equipment.
CAUTION
Equipment listed in the data sheet allowed range of temperature, humidity and air
pressure in use. When used in an environment that exceeds the tolerance of the
device can cause malfunction or failure.
CAUTION
This equipment is indoor use and all the communication wirings are limited to inside
of the building.
MAXFOR Technology Inc.
MQEP-22-04 ( 5 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
3. Introduction
The MFG-G400 is functions as a gateway to transmit data to server without going through PC being
collected data from wireless sensor network.
4. Features
z Ubiquitous Sensor Network Gateway z SAMAUNG S3C6410 (ARM core) 633MHz chip. z Linux Kernel 2.6.x support. z Ethernet, Serial, JTAG, USB, GPIO Connectors. z USN to BcN Wireless interface.
5. Specification
Item Specification Remark
MAIN
Process SAMSUNG S3C6410- 667MHz ARM11 Core
Memory
SDRAM 128 Mbytes DDR2 533MHz
NAND Flash 64 M bytes
Boot Flash 4 Megabit
OS Linux Kernel 2.6.x
Interface
Parallel GPIO 4 Ports
Serial
USB HOST 1 Port
Console 1 Port
RS232 2 Port
LAN RJ-45 1 Port 100Mbps Only
Debug On-Board JTAG Converter
LED Debugging 5 Bits POWER, STATE, LINK, Tx, Rx
Support Device CDMA, WLAN Option
Alarm Light
RF
Freq. band 2.405G -2.475GHz IEEE 802.15.4
MAXFOR Technology Inc.
MQEP-22-04 ( 6 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
RF power -55dBm - 8dBm Boost mode
Sensitivity -102dBm Receive sensitivity
Antenna Dipole Antenna
System Operation
Temperature Range
Operating -20°C - 50°C
Storage -20°C - 50°C
Humidity Range 0~95% RH, non-condensing
Power In 12V DC
Power Out
USB Port: 5V , 500mA
Alarm Port: 12V , 200mA
Buzzer Port: 12V , 200mA
Consumption 2.0A
Dimension 185(W) X 130(D) X 45(H)mm
IP Code IPXX
Power source
AC power adapter
Input: 100-240VAC, 50/60Hz, 1200mA
Output: 12VDC, 3.33A
Model NO: GC99D040012
NOTE
Specifications are subject to change without notice.
MAXFOR Technology Inc.
MQEP-22-04 ( 7 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
6. Designation
NO. Description
1 LED ( Power, STATE, LINK, Tx, Rx)
2 ANTENNA(Dipole antenna)
3 Magnetic key
4 4.3 inch LCD
5 Power & Eternet Hole
MAXFOR Technology Inc.
MQEP-22-04 ( 8 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
7. Remote access method to MFG-G400
- Remote access is used to confirm only sensor data and Set values is used to Default values.
CAUTION
If you change the setting, remote VNC connection and data linkage can be a
problem.
7.1 Access method to VNC Viewer
① VNC Viewer Program Installation
② Run VNC Viewer and Connect Server
③ VNC connection screen
MAXFOR Technology Inc.
MQEP-22-04 ( 9 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
8. Installation
- Locate the Gateway in an area easily accessible by a technician.
- Avoid locations in which the Gateway will be subjected to vibration or rapid temperature fluctuations.
- Follow local regulations and site requirements.
9. Maintenance
Cleaning
- Use a soft cloth and mild detergent to clean the device. Do not use paint thinner, benzene, solvent or
strong detergent.
- Be sure to turn the power key off before cleaning the device.
- Only authorized service personnel should remove the cover of the unit.
Storage
- Store the equipment in an area with moderate temperature and humidity.
- If the equipment is not to be used for a long time, it is recommended to protect it from dust, dirt or
humidity.
- Keep it away from any heating source, direct sunlight, water vapor, or such environment as poor
ventilation, excessive shock or vibration.
10. Contact information
Web site: http://www.maxfor.co.kr
MAXFOR Technonogy Inc..
: 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
POST No. : 449-823
TEL : +82-31-337-0486
FAX : +82-31-339-7126
MAXFOR Technology Inc.
MQEP-22-04 ( 10 / 10 ) R.0
A4(210×297mm)
MAXFOR Technology 48, Banjeong-ro, Yangji-my e on, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
FCC Part 15.105 statement
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
FCC Part 15.21 statement
Any changes or modifications to this device not explicitly approved by manufacturer could void your
authority to operate this equipment.
FCC Part 15.19 statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Body-worn Operation
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum 20 cm between the radiator and your
body. This transmitter must not be collocated or operating in conjunction with any other antenna or
transmitter unless authorized to do so by the FCC.
Loading...