This manual has been created for informative purpose. The company declines every responsibility for the results of projecting or installation based on the explanations and the technical specifications given
in this manual. Is besides forbidden the reproduction under any form of the texts and of the figures contained in this manual.
2.4 Operation data .......................................................................................................................................... 6
3.1 Indoor units ............................................................................................................................................... 7
3.2 Outdoor units ............................................................................................................................................7
5.1 Indoor units ............................................................................................................................................... 9
5.2 Outdoor units ............................................................................................................................................9
6.1 Indoor units ............................................................................................................................................. 10
6.2 Outdoor units ..........................................................................................................................................10
7. CONTROL FUNCTIONS .........................................................................................................................11
7.1. Temperature parameters ....................................................................................................................... 11
for the dischar
Permissible excessive operating pressure
for the suction side
Sound pressure level dB(A) 49/-/- 50/-/-
Sound power level dB(A) 59/-/- 60/-/-
Dimensions (WXHXD) mm 906 x 596 x 378 906 x 596 x 378
Dimension of package (L/W/H) mm 948 x 420 x 645 348 x 420 x 645
Net weight/gross weight kg 43/47 43/47
Refrigerant charge (R410A) kg 1,3 1,3
Length m 5 5
Gas additional charge g/m 20 20
Outer diameter
Max distance
Connecting pipe
e side
Liquid pipe mm Φ6 Φ6
Gas pipe mm Φ9,52 Φ9,52
Height m 10 10
Length m 15 20
Mpa 3,8 3,8
Mpa 1,2 1,5
The above data of specifications are subject to change without prior notice. Please refer to the actual data specified on the nameplate of
the unit.
Note: Test conditions:
Standard condition
Rated cooling 27 19 35 24
Rated heating 20 15 7 6
3) Microphone at a distance of 1m from the unit.
Approximate calculation from Sound Pressure Level to Sound Power Level:
- Average Sound Pressure Level
L
: Sound pressure level of front test point.
1P
L
: Sound pressure level of side test point for indoor unit
2P
- Approximate Sound Power Lever
Dry bulb temp. °C Wet bulb temp. °C Dry bulb temp. °C Wet bulb temp. °C
Indoor side state Outdoor side state
*1.0*1.0
LL
21
L
L
=10*lg
p
=
W
+
L
+10.
L
p
PP
1010(*2/1
1P
.
L
,
.
2P
5
0
2. CHARACTERISTICS DATA
2.1 Operation characteristic curve
Cooling
10
Condition
Indoor:DB27
Outdoor:DB35 WB24
8
Indoor air flow: Super High
Pipe length: 5m
6
4
Current (A)
2
0
WB19
BDS35A
BDS28A
Compressor speed (rps)
2.2 Capacity variation ratio according to temperature
200
180
160
140
120
100
80
60
Capacity ratio(%)
40
20
0
33353739414345
BDS28A
BDS35A
Condition
Indoor:DB27
Indoor air flow: Super High
Pipe length: 5m
WB19
Outdoor temp.( )
2.3 Noise criteria curve
50
45
40
35
30
25
Noise/dB(A)
20
15
10
Super High
BDS35A
BDS28A
HighMiddleLowQuiet
Indoor fan motor rotating speed (rps)
2.4 Operation data
Heating
10
Condition
Indoor:DB20
Outdoor:DB7
8
Indoor air flow:Super High
Pipe length: 5m
6
4
Current (A)
2
0
505151020304060708090020304060708090
BDS35A
BDS28A
Compressor speed (rps)
gnitaeHgnilooC
200
180
160
140
120
100
80
60
Capacity ratio(%)
40
20
0
-18-14-10-6-2261
BDS28A
BDS35A
Condition
Indoor:DB20
Indoor air flow:Super High
Pipe length: 5m
Outdoor temp.( )
tinUroodtuOtinUroodnI
55
50
45
Noise/dB(A)
40
35
30
082030405060708090
Compressor speed (rps)
BDS35A
BDS28A
Cooling:
Temperature
conditions (°C)
Indoor Outdoor
27/19 35/24
Model
name
BDS28A
BDS35A
Standard
pressure
Heat exchanger pipe
temp.
P(MPa) T1 (°C) T2 (°C)
0,9~1,2
In: 12~14
Out: 10~12
In: 41~43
Out: 43~45
Indoor fan speed
Outdoor fan
speed
Super high Super High
Compressor
revolution (rps)
34
55
6
Heating:
Temperature
conditions (°C)
Indoor Outdoor
20/15 7/6
Model
name
BDS28A
BDS35A
Standard
pressure
P(MPa) T1 (°C) T2 (°C)
2,0~2,6
Heat exchanger pipe
temp.
In: 33~35
Out: 42~44
In: 3~5
Out: 3~5
Indoor fan speed
Super high Super high
Outdoor fan
speed
Notes:
(1) Connecting piping condition: 5m.
(2) T1: Outlet and inlet pipe temperature of evaporator.
T2: Outlet and inlet pipe temperature of condenser.
P: Pressure of air pipe used for connecting outdoor and indoor units.
Notes:
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor thermometer)
(2) Connecting piping condition: 5m.
3. DIMENSIONS
3.1 Indoor units
866
209
Compressor
revolution (rps)
41
55
3.2 Outdoor units
541162163
7
4. REFRIGERANT DIAGRAM
TINUROODTUOTINUROODNI
GAS SIDE
HEAT
EXCHANGE
(EVAPORATOR)
3-WAY VALVE
LIQUID SIDE
2-WAY VALVE
Discharge
Suction
COMPRESSOR
4-Way valve
Accumlator
Electron expansion valve
HE AT
EXCHANGE
(CONDENSER)
reniartSreniartS
COOLING
HEATING
8
5. ELECTRICAL CIRCUIT DIAGRAM
5.1 Indoor units: BDS28A, BDS35A
FAN
MOTOR
M1
DC-MOTOR
CAP
JUMP
SWING-LR
M2
SWING
ROOM
TEMP.SENSOR
0
TUBE
TEMP.SENSOR
0
RT2RT1
ROOMTUBE
AP2
PRINTEDCIRCUITBOAR D
SWING-UD1
M3
SWING
MOTOR(U.D1)MOTOR(L.R)
RECEIVER AND
DISPLAYBOARD
AP1
SWING-UD2
M4
SWING
MOTOR(U.D2)
MAGNETIC
RING
N
DISP2DISP1
AC-L
COM-OUT
L-OUT
K7
HEALTH-LHEALTH-N
RDBU
COOL PLASMA
GENERATOR
L
L
BN(BK)
BU(WH)
POWER
L
N
YEGN(GN)
BU
BK
BN
XT1
N(1)
2
3
CONN WIRE
BU
BK
BN
YEGN
TERMINAL
BOARD
OUTDOOR UNIT
PE
YEGN
EVAPORATOR
YEGN
PE
5.2 Outdoor units: BDS28A, BDS35A
SAT
W3YEGN
PE
W10RD
YEGN
PE
XT2
BU
INDOOR UNIT
N(1)
BK
BN
L1
2
L1
3
W2BU
W4BK
W1BN
E
OVC-COMPCN2
N1
COMU
AC-L1
OFAN1
M
FAN
CN1
EKV
PE
TUBE
TEM.SENSOR
RT1
0
4V AC-L2
RT2
4YV
OUTROOM
TEM.SENSOR
0
L3
EXHAUST
TEM.SENSOR
RT3
0
LX-2
W11
L2L2L2
W5BU
COMP-U
AP1
LX-1
L3
L
COMP
R
COMP
S
W7RD
W6YE
COMP-V COMP-W
W12
W13WH
WHOG
P
HP
E
C
HPP
W8YEGN
HEAT-N2 HEAT-L
(CHASSIS)
PE
N2N3
EH2
HEATER
W9BU
HEAT-N1
RD RD
EH1
HEATER
(COMP)
9
6
7
6. PRINTED CIRCUIT BOARD
6.1 Indoor unit: BDS28A, BDS35A
12345
15
14
13
6.2 Outdoor units: BDS28A, BDS35A
No Part name
1 DC fan
2 Microswitch
3 Electrostatic precipitation
4 Small up & down swing interface
5 Left and right
Big up & down swing interface
6
7 Display interface
8 Ambient temperature sensor
9 Tube temperature sensor
Outdoor unit live wire
10
Input interface of live wire for
11
indoor unit
Health
12
Fuse
13
Interface of neutral wire for
14
indoor and outdoor units
Communication interface of
89111012
15
indoor and outdoor units
No Part name
1 Input of neutral wire of power
2 Input of live wire of power
Communication interface
3
Interface 1 of electric reactor
4
Interface 2 of electric reactor
5
6 Interface of fan
Neutral wire of electric heater of
7
chassis
Neutral electric wire of
8
compressor
9 Neutral wire of 4-way valve
Live wire of 4-way valve
10
Live wire of electric heater
11
Input of overload
12
Temperature sensor
13
U, V, W three phases of
14
compressor
15 Input of ground wire of power
10
7. Control functions
7.1. Temperature Parameters
• Indoor preset temperature (Tpreset)
• Indoor ambient temperature (T
amb)
7.2. Basic functions
Once energized, the compressor should in no way be restarted unless after at least 3-minute time interval. In case of having
memory function, for the first energization, the compressor will be started without 3-minute lag, if being under the condition
of power-off, and the compressor will have 3-minutes delay to be started under the condition of power-on. Once started, the
compressor will not be stopped within 6 minutes with the changes of room temperature.
7.2.1 Cooling Mode
Cooling Condition and Process
When T
and the indoor fan will run at preset speed.
When T
at preset speed.
When T
■ Under this mode, the switchover (reversal) valve will be de-energized and the temperature can be set from 16°C to 30°C.
If the compressor is shut down for some reason, the indoor fan and the swing device will operate at the original state.
amb.≥ Tpreset , the unit will run under cooling mode, in which case the compressor and outdoor fan will be started,
amb.≤ Tpreset -3°C, the compressor will stop, the outdoor fan will stop with time lag of 30s, and the indoor fan will run
preset -3°C <Tamb. < Tpreset , the unit will maintain its original operating status.
Tpreset
Tpreset –2 ˚C
Tamb.
≥ 6 min.≥ 3 min.≥ 6 min.
Start cooling
Original operating status
Stop cooling
Compressor
Outdoor fan
Indoor fan
Run
Setting fan speed
Stop
Protection function
♦ Overcurrent protection
If total current is high, the compressor will run in limited frequency. If total current is too high, the compressor will stop, the
outdoor fan will delay 30 seconds to stop, indoor unit will display E5 and outdoor yellow light will blink 5 times.
♦ Antifreeze protection
When the antifreeze protection is detected, the compressor will stop, the outdoor fan will stop after 30 seconds, and the
indoor fan and swing motor will keep running in the original mode. When antifreeze protection is eliminated and the
compressor has stopped for 3 minutes, the compressor will resume running in the original mode.
The period ofantifreezing protection
Compressor
3 min
Outdoor fan
Indoor fan
Low fan speed
Run
Stop
11