Max P002, 216, 213, 215, 214 User Manual

Positive Displacement Flowmeters
Operational Manual
For Models Model 213, P002, 214, 215 and 216
Model
Model
Model
Model
Model
210 Piston Series
Positive Displacement Flow Meters
Max Machinery, Inc. 210 Series User Manual © Copyright 2013 Rev. 002Q4 1
Table of Contents
Before You Install .................................................................................. page 3
Meter General Description ..................................................................page 4
Transmitter General Description ....................................................... page 5
Meter Specications ............................................................................page 6
Transmitter Specications Analog ................................................... page 7
Transmitter Specications Frequency (Pulse) ............................... page 8
Do’s & Don’ts .......................................................................................... page 9
Installation .............................................................................................page 10
Operation ................................................................................................ page 11
Electrical Installation - Wiring ...................................................... page 12-13
Troubleshooting ...................................................................................page 14
Diagrams & Pressure Drop:
213 Piston Flow Meter .......................................................... page 15
P002 Piston Flow Meter .....................................................page 16
214 Piston Flow Meter ......................................................... page 17
215 Piston Flow Meter .........................................................page 18
216 Piston Flow Meter .........................................................page 19
Contact for Repairs & Calibration Services ..................................page 20
Custom Instructions for Hazardous Locations/Explosion Proof Housing: www.maxmachinery.com/content/explosion-proof-installation-instructions
DO NOT ATTEMPT TO INSTALL OR START FLOW METER WITHOUT READING THIS ENTIRE MANUAL
Max Machinery, Inc. (MMI) reserves the right to make changes to the product in this Instruction Manual to improve performance, reliability, or
manufacturability. Consequently, contact MMI for the latest available specications and performance data. Although every effort has been made to
ensure accuracy of the information contained in this Instruction Manual, MMI assumes no responsibility for inadvertent errors.
Max Machinery, Inc. 210 Series User Manual © Copyright 2013 Rev. 002Q4 2
Before You Install
Thank you for choosing to install a Max Machinery precision ow meter. To ensure the best experience please take a
moment to read through this manual prior to installation.
When you purchased this meter a ow engineer helped determine many of the factors that will be reviewed on the following pages. You may nd it useful to ll out the form below and keep it in your les for reference.
When you are ready to install there will be a few tools you will need:
Meter Installation: The meter and transmitter
A signal cable (available from factory)
The display or signal processing device Indicator Manual
Calibration Certicate
Bypass plumbing supplies
Many Max meters are installed and operate for decades, so having the following information in your records may prove useful. We have provided this outline as a starting point.
Process Temperatures ___________________________ Fluid Viscosity ____________________________________
Operating Range ________________________________ Line Pressure ____________________________________
Max Sales # or PO # _____________________________ Installation Date __________________________________
Meter Model # __________________________________ Meter Serial # ____________________________________
Transmitter Model # _____________________________ Transmitter Serial # _______________________________
Notes: _____________________________________________________________________________________________
_____________________________________________________________________________________________
_____________________________________________________________________________________________
_____________________________________________________________________________________________
Max Machinery, Inc. 210 Series User Manual © Copyright 2013 Rev. 002Q4 3
Meter General Description
The Max 210 Series Flow Meters are positive displacement piston type units capable of great accuracy over a wide range
of ow rates and uid viscosities. The four basic sizes of this series (213, 214, 215, 216) will measure ows from 1 cc/min
to 25 gal/min. Various “O” ring and internal plating options
are available to meet temperature and uid compatibility
requirements.
In a piston type ow meter, four pistons and cylinders are
arranged in a radial fashion around a central crankshaft.
Two uid ports on the cylinder wall, a port at the top of the cylinder, and a grooved piston enable uid entering the ow
meter’s central cavity to be measured and pumped out by each piston in turn. The valving action for each cylinder is
accomplished by the piston adjacent to it. The accuracy of a piston ow meter is dependent on close tolerances in the cylinder wall and piston. Max Machinery regularly holds tolerances as ne as 0.00005 inches in the production of these
meters.
The movement of the pistons is converted to a circular motion at the
central crankshaft, which is coupled to a magnet in the ow meter. This
motion is sensed by an external electronic transmitter, which converts
ow into a voltage, pulse train, or current for further processing.
inlet outlet
The Max Series 210 Meter can be expected to perform superbly if
operated within the connes of its design envelope. For this reason,
it is important to read this manual and understand the operational requirements and limits of the meter. Our Technical Service staff will be happy to answer any questions that this manual does not cover.
Max Model 214
Max Machinery, Inc. 210 Series User Manual © Copyright 2013 Rev. 002Q4 4
Transmitter General Description
Max transmitters are designed to work with the entire family of Max Flow Meters to provide extremely precise ow
measurement in a cost effective package. Different options of industrial housings or IP66 rated explosion proof enclosures, combined with a choice of one-part and two-part, high temperature designs with remote electronics cover a wide range of application environments – from the laboratory to harsh industrial processes.
This latest generation of transmitters use modern sensor technology coupled with advanced signal processing to deliver high levels of performance and reliability. Hall sensors are used to detect the position of a driven magnet inside a Max
Flow Meter. Changes in position are tracked by a microprocessor, which generates an output proportional to the ow rate. Advanced signal processing provides both ne angular resolution (0.36 degrees rotation) and rapid response
(output updated every one millisecond).
Max transmitters are typically mated to a mechanical ow meter, congured, and calibrated at the factory as a set. This ensures accuracy and allows quick setup in the eld. For eld installations where the transmitter has not been set up with a meter at the factory, an optional serial interface kit may be purchased to give full access to conguration
options and parameters.
Transmitter Features
High resolution measurement –
Analog Output: Congured output ranges to any value within ± 10 Vdc or ± 20 mA. Frequency Output: Congured output resolution of 1 to 1000 pulses per revolution. Linearization of up to 16 points to fully describe the ow meter’s output curve and achieve the highest system
linearity over the meter’s entire operating range.
Compensation Algorithm – Compensates for variations in Hall sensor and ow meter characteristics to provide a stable, undamped output that accurately represents the instantaneous ow rate. This feature is factory set when the meter
and transmitter are mated together. If the transmitter is changed, the compensation can be performed via a button on the circuit board.
Anti-Dither Buffer - Masks the false output that may occur at very low ow rates in the presence of vibration or hydraulic
noise. If the meter reverses direction the output signal will be interrupted for a user selected portion of a meter rotation.
Reverse ow exceeding the buffer setting will result in an output proportional to reverse ow rate. The buffer quantity
can be set from 1% to 100% of a revolution.
213 Standard 213 2-Part Pickup 213 Ex-Proof
Max Machinery, Inc. 210 Series User Manual © Copyright 2013 Rev. 002Q4 5
Meter Specications
Model 213 P002 214 215 216
1
Maximum ow rate
Gal/min: 0.48 0.53 2.64 9.25 26.4 Liters/min: 1.8 2.0 10 35 100
Maximum pressure (psi)
2xx-3xx, 2xx-4xx: 1,000 psi (70 bar) 2xx-6xx: 3,000 psi (210 bar) P002, 214-5xx 7,250 psi (500 bar)
Pressure drop (PSIG)
Operating maximum: 15 15 28 30 30
Absolute maximum: 20 20 30 42 42
100% Flow (3cps): 3.25 3.25 3.5 5 9
2
Maximum temperature --------------------- 1 part: 195°F (90°C) --------------------
2
Maximum temperature -------------------- 2 part: 435°F (225°C) --------------------
3
Recommended ltration 10 micron 10 micron 10 micron 10 micron 10 micron Displacement (cc/rev) 0.887 1.0 10.5 47.6 169.5 Weight (lbs) 1000 & 3000 psi 1.25 (0.57Kg) --- 6.25 (2.8Kg) 22.75 (10.3Kg) 55.25 (25.1Kg) 7250 psi --- 4.2 (1.9kg) 14.4 (6.5) --- --- Typical k-factor (pulses/cc) 290 Frequency series Transmitter 1000 1000 90 20 5
Port size (NPT): 0.125” --- 0.375” 0.500” 0.750” SAE #4 #4 #6 #12 #18
1
For viscosities of 30 cps or more, derate per pressure drop curves for higher viscosities.
2
Dependent on meter seal material, transmitter model, orientation and ambient temperature. See transmitter manual;
consult factory.
3
Some materials may have different lter requirements, consult factory.
Max Machinery, Inc. 210 Series User Manual © Copyright 2013 Rev. 002Q4 6
Loading...
+ 14 hidden pages