Matrox XC-75 Application Note

Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Sony XC-75 May 31, 1996
Camera Interface Overview
Camera Interface Details
640 x 484 x 8-bit @ 60fps (max)
Analog video output
Internal or external sync
Internal or external exposure control
4 modes: continuous mode (internal sync), continuous mode (external sync), restart reset
mode, asynchronous shutter mode (S-Donpisha mode)
1. Continuous mode (internal sync)
640 x 484 x 8-bit @ 30fps
Analog (composite) video output
Interlaced
Continuous video
DCF used: XC75.DCF
Sony
XC-75
Video
Matrox Pulsar
(with PLS-TTL-CABLE)
2. Continuous mode (external sync)
640 x 484 x 8-bit @ 30fps
Analog video output
Interlaced
Continuous video
Matrox Pulsar sending TTL hsync (HD) and vsync (VD) signals to camera
DCF used: XC75M.DCF
Sony
XC-75
Video
HD VD
Matrox Pulsar
(with PLS-TTL-CABLE)
3. Restart reset mode
Sony
XC-75
640 x 484 x 8-bit @ 15fps (max)
Analog video output
Interlaced
Matrox Pulsar receiving TTL external trigger
Matrox Pulsar sending TTL hsync (HD) and vsync (RR trigger) signals to camera
DCF used: XC75AM.DCF
Video
HD
RR Trigger
TTL external trigger
Matrox Pulsar
(with PLS-TTL-CABLE)
Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Sony XC-75 May 31, 1996
Camera Interface Details
Cabling Requirements
4. Asynchronous shutter mode (S-Donpisha mode)
Video
Sony
XC-75
640 x 240 x 8-bit @ 60fps (max)
Analog video output
Non-interlaced
External exposure control with exposure times ranging from 42.2µs to 13ms in increments
TTL external trigger
HD VD
Async. Shutter
Matrox Pulsar
(with PLS-TTL-CABLE)
of 63.5µs
Matrox Pulsar receiving TTL external trigger
Matrox Pulsar sending TTL hsync (HD), vsync (VD) and asynchronous shutter trigger
signals to camera
DCF used: XC75DP1.DCF
1. Continuous mode (internal sync)
IMG-7W2-TO-1BNC (or 5BNC) required for video signal
Video input BNC of IMG-7W2-TO-1BNC cable should be connected to VIDEO OUT
BNC connector of camera
2. Continuous mode (external sync)
IMG-7W2-TO-1BNC (or 5BNC) required for video signal; PLS-TTL-CABLE required
for digital syncs
Video input BNC of IMG-7W2-TO-1BNC cable should be connected to VIDEO OUT
BNC connector of camera
The connections between the DB-37 connector of the PLS-TTL-CABLE and the12-pin
connector of the camera are as follows:
PLS-TTL-CABLE Sony XC-75 (DB-37 connector) (12-pin connector)
Pin name Pin no. Pin name Pin no.
GROUND 6 & 7 VD INPUT (GND) 12 GROUND 6 & 7 HD INPUT (GND) 5 GROUND 6 & 7 VIDEO OUT (GND) 3 GROUND 6 & 7 GND 1 GROUND 6 & 7 GND 10 TTL_VSYNC 11 VD INPUT 7 TTL_HSYNC 26 HD INPUT 6
PUL-CID-020 2
Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Sony XC-75 May 31, 1996
Cabling Requirements Continued
3. Restart reset mode
IMG-7W2-TO-5BNC required for video signal and TTL external trigger signal; PLS-
TTL-CABLE required for digital syncs
Video input BNC of IMG-7W2-TO-5BNC cable should be connected to VIDEO OUT
BNC connector of camera
The connections between the DB-37 connector of the PLS-TTL-CABLE and the12-pin
connector of the camera are as in continuous mode (external sync)
TTL external trigger source should be connected to the TTL Trigger Input of the IMG-
7W2-TO-5BNC cable
4. Asynchronous shutter mode (S-Donpisha mode)
IMG-7W2-TO-5BNC cable required for video signal and TTL external trigger signal;
PLS-TTL-CABLE required for digital syncs
Video input BNC of IMG-7W2-TO-5BNC cable should be connected to VIDEO OUT
BNC connector of camera
The connections between the DB-37 connector of the PLS-TTL-CABLE and the12-pin
connector of the camera are as in continuous mode (external sync)
The connections between the DB-37 connector of the PLS-TTL-CABLE and the 6-pin
lens connector of the camera are as follows:
Special Considerations
PLS-TTL-CABLE Sony XC-75 (DB-37 connector) (6-pin connector)
Pin name Pin no. Pin name Pin no.
GROUND 7 GND 3 TTL_EXPOSURE2 27 TRIGGER 2
TTL external trigger source should be connected to the TTL Trigger Input of the IMG-
7W2-TO-5BNC cable
Asynchronous shutter mode (S-Donpisha mode)
The delay between the external trigger signal and the start of exposure is 16 lines or 1ms
The exposure time can be set by modifying the DCF at the hardware register level. A
hardware register editor is provided by running Intellicam with the -hwreg option (specifically by running INTELCAM -hwreg). An additional menu item, “HW REGISTER EDITOR”, appears on the main menu screen. The PSG_SETVCNT register controls the exposure time:
Exposure time = (16381 lines PSG_SETVCNT) 63.49µs + 42.2µs Or PSG_SETVCNT = 16381 lines (exposure time 42.2µs) / 63.49µs
PUL-CID-020 3
Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Sony XC-75 May 31, 1996
Special Considerations Continued
The value of PSG_SETVCNT must be an integer number of linetimes (one linetime =
63.49µs) and must be set in hexadecimal. The exposure time can vary from 42.2µs to 13ms. An exposure time of 42.2µs results when PSG_SETVCNT is set to 3FFD in hex (16381 lines); setting PSG_SETVCNT to 3F32 in hex (16178 lines) yields an exposure time of 13ms. The default exposure time in this DCF is 10ms; the corresponding value of PSG_SETVCNT is 3F60h (16224 lines). The register is set in the following way:
PSG_SETVCNT = 3F60H
When computing the hardware registers, the following question may be asked: “Some registers have been manually edited. Ok to overwrite them all? (y/n)”. Answer “no” to this question and to all questions that follow.
IMPORTANT! These instructions must be followed very carefully; the only register that should be modified is the one mentioned above. Please consult Matrox Imaging
Applications at (514) 822-6061 if assistance is required.
The time between external trigger signals must be greater than the sum of the exposure
time and the frame transfer time (16.7ms); since the default exposure time is 10ms, the trigger rate must be less than 37.5Hz for the current settings of the DCF
The camera must be modified in order to operate in S-DONPISHA mode. The following
settings are required inside the XC-75 head:
MB-403 board:
JR1 must be shortedJR3 must be shortedJR2 must be set to the T position
SG-199 board:
JR7 and JR 8 must be open
The connections described in this document can also be achieved by using the JB-77
junction box. Consult the Sony XC-75 camera manual for a pinout description
The DCF(s) mentioned in this application note can be found on the MIL and MIL-Lite CD, or our FTP site (ftp.matrox.com). The information furnished by Matrox Electronics System, Ltd. is believed to be accurate and reliable. Please verify all interface connections with camera documentation or manual. Contact your local sales representative or Matrox Sales office or Matrox Imaging Applications at 514-822-6061 for assistance.
CorporateCorporate Headquarters:Headquarters: Canada and U.S.A.Canada and U.S.A. Matrox ElectronicMatrox Electronic Systems Ltd.Systems Ltd.
1055 St.Regis Blvd. Dorval, Quebec, Canada H9P 2T4 Tel: (514) 685-7230 Fax: (514) 822-6273
Sales Offices:Sales Offices: U.K.U.K.
Matrox (UK) Ltd.Matrox (UK) Ltd.
Sefton Park, Stoke Poges Buckinghamshire U.K. SL2 4JS Tel: +44 (0) 1753 665500 Fax: +44 (0) 1753 665599
FranceFrance Matrox France SARLMatrox France SARL
2, rue de la Couture, Silic 225 94528 Rungis Cedex Tel: (0) 1 45-60-62-00 Fax: (0) 1 45-60-62-05
GermanyGermany Matrox GmbHMatrox GmbH
Inselkammerstr.8 D-82008 Unterhaching Germany Tel: 089/614 4740 Fax: 089/614 9743
Asia PacificAsia Pacific Matrox Asia LiaisonMatrox Asia Liaison OfficeOffice
Rm. 1901, 19/F, Workington Tower, 78 Bonham Strand E., Sheung Wan, Hong Kong. Tel: 852.2877.5387 Fax: 852.2537.9530
PUL-CID-020 4