Matrox TM6701AN Application Note

Application Note:
Interfacing non-standard cameras to Matrox Pulsar PULNIX TM-6701AN February 4, 1998
Camera Descriptions
640 x 480 x 8-bit @ 60fps or 640 x 240 x 8-bit @ 120fps
Analog video output.
Internal sync.
25.49 MHz pixel clock rate.
Internal exposure control.
Interface Modes Continuous (60 MHz, 120 MHz), internal reset (fast, slow)
Camera
Mode 1 : Continuous (60 Hz)
Interface Briefs
PULNiX
TM 6701AN
640 x 480 x 8-bit @ 60fps
Analog (composite) video output.
Continuous video.
Double-speed progressive scan.
DCF used : T6701N1.DCF
Video
Mode 2 : Continuous (120 Hz)
PULNiX
TM 6701AN
Video
Matrox Pulsar
Matrox Pulsar
640 x 240 x 8-bit @ 120fps
Analog (composite) video output.
Continuous video.
Two-row progressive scan.
DCF used: T6701N2.DCF
Mode 3: Internal fast reset mode
Mode 3: Internal fast reset
PULNiX
TM 6701AN
640 x 480 x 8-bit @ 60fps (max)
Analog (composite) video output
Double speed progressive scan
Internal exposure control: exposure time
Matrox Pulsar receiving TTL external trigger
Matrox Pulsar sends TTL_EXPOSURE1 (VINIT in) signal to camera to initiate exposure
DCF used: T6701NS0.DCF
Video
EXPOSURE1
TTL external trigger
Matrox Pulsar
with PLS-TTL-CABLE
PUL-CID-050
Application Note:
Interfacing non-standard cameras to Matrox Pulsar PULNIX TM-6701AN February 4, 1998
Mode 4: Internal slow reset mode
Camera Interface Briefs (continued)
Mode 4: Internal slow reset
PULNiX
TM 6701AN
640 x 240 x 8-bit @ 120fps (max)
analog (composite) video output
two row progressive scan
internal exposure control: exposure time set with shutter control switch on rear panel of
Video
EXPOSURE1
TTL external trigger
Matrox Pulsar
with PLS-TTL-CABLE
camera (positions 5-8)
Matrox Pulsar receiving TTL external trigger
Matrox Pulsar sends TTL_EXPOSURE1 (VINIT in) signal to camera to initiate exposure.
DCF used: T6701NS1.DCF
Mode 5 : Asynchronous reset (60 Hz)
PULNiX
TM 6701AN
640 x 480 x 8-bit @ 60fps (max.)
Analog (composite) video output.
Double-speed progressive scan.
Matrox Pulsar receiving TTL external trigger.
Matrox Pulsar sending EXPOSURE1 (VINIT) signal to camera to initiate exposure and
Video
EXPOSURE1
TTL external trigger
Matrox Pulsar
with PLS-TTL-CABLE
control exposure time
DCF used : T6701N1E.DCF
Mode 6 : Asynchronous reset (120 Hz)
PULNiX
TM 6701AN
640 x 240 x 8-bit @ 120fps (max.)
Analog (composite) video output.
Two-row progressive scan.
Matrox Pulsar receiving TTL external trigger.
Matrox Pulsar sending EXPOSURE1 (VINIT) signal to camera to initiate exposure and
Video
EXPOSURE1
TTL external trigger
Matrox Pulsar
with PLS-TTL-CABLE
control exposure time
DCF used: T6701N2E.DCF
PUL-CID-050
2
Application Note:
The three switches on the rear of the camera
Interfacing non-standard cameras to Matrox Pulsar PULNIX TM-6701AN February 4, 1998
Camera Interface Details
Mode 1 and 2: Continuous (60 and 120 Hz)
ASY N O
Set "Shutter"
Control Dial to "0"
NRM P T
must be set to NRM, N, and O for 60 Hz operation, and NRM, N, and T for 120 Hz operation.
The shutter control switch on the rear of the
camera must be set to position ‘0’.
Camera's Rear Panel
Mode 3 and 4: Internal fast and slow reset
Positions 1 through 8 of the shutter control switch on the rear of the camera correspond to
the following exposure times:
Shutter control switch positions
Internal fast reset mode Internal slow reset mode
Position Exposure time (s) Position Exposure time (s) 1 1/320001H 5 1/200016H 2 1/160002H 6 1/100032H 3 1/8000 4H 7 1/500 64H 4 1/4000 8H 8 1/250128H
The delay between the rising edge of the external trigger pulse and the falling edge of the
TTL_EXPOSURE1 pulse is 10µs.
The width of the TTL_EXPOSURE1 pulse must be greater than 63µs (two horizontal line
times).
The camera is reset upon the falling edge of the TTL_EXPOSURE1 (VINIT IN) pulse and
will expose for the amount of time as set on the shutter control switch..
Mode 5 and 6 : Asynchronous reset (Pulse Width Control - 60 and 120 Hz)
The three switches on the rear of the camera must be set respectively to ASY (asynchronous
shutter mode), N and O for 60 Hz operation, and ASY, N, and T for 120 Hz operation; the shutter control switch on the rear of the camera must be set to position 9.
The camera is reset upon the falling edge of the EXPOSURE1 (VINIT IN) pulse. The
exposure period is for the inactive (low) period of EXPOSURE1 (VINIT IN). The default exposure time in this DCF is 6.4 ms.
PUL-CID-050
3
Application Note:
Interfacing non-standard cameras to Matrox Pulsar PULNIX TM-6701AN February 4, 1998
Cabling Requirements
Mode 1 and 2: Continuous (60 and 120 Hz)
IMG-7W2-TO-1BNC cable required for video input of camera (single input)
Video input of IMG-7W2-TO-1BNC cable should be connected to video out BNC
connector of camera
Mode 1: Internal fast reset mode
Mode 3: Internal slow reset
IMG-7W2-TO-5BNC cable and PLS-TTL-CABLE required
video input BNC of IMG-7W2-TO-5BNC cable should be connected to VIDEO OUT BNC
connector of camera
the three switches on the rear of the camera must be set respectively to ASY (asynchronous
shutter mode), N and O; the shutter control switch on the rear of the camera must be set to a position between 1 and 4
the connections between the DB-37 connector of the PLS-TTL-CABLE, the 12-pin
connector of the camera and the power supply are as follows:
PLS-TTL-CABLE PULNiX TM-6701AN POWER (DB-37 connector) (12-pin connector) SUPPLY Pin name Pin no. Pin name Pin no.
TTL_EXPOSURE1 9 VINIT in 6 GROUND 7 GND 1, 3, 5, or 8 GND
12V DC in 2 +12V
TTL external trigger source should be connected to the TTL Trigger Input of the IMG-7W2-
TO-5BNC cable.
Mode 4: Internal slow reset
IMG-7W2-TO-5BNC cable and PLS-TTL-CABLE required
video input BNC of IMG-7W2-TO-5BNC cable should be connected to VIDEO OUT BNC
connector of camera
the three switches on the rear of the camera must be set respectively to ASY (asynchronous
shutter mode), N and T; the shutter control switch on the rear of the camera must be set to a position between 5 and 8
the connections between the DB-37 connector of the PLS-TTL-CABLE and the 12-pin
connector of the camera are as in internal fast reset mode.
TTL external trigger source should be connected to the TTL Trigger Input of the IMG-7W2-
TO-5BNC cable
PUL-CID-050
4
Application Note:
The DCF(s) mentioned in this application note can be found on the MIL and MIL-Lite CD, or our FTP site (ftp.matrox.com). The information furnished
Interfacing non-standard cameras to Matrox Pulsar PULNIX TM-6701AN February 4, 1998
Cabling Requirements (continued)
Mode 5 and 6 : Asynchronous reset (Pulse Width Control - 60 and 120 Hz)
IMG-7W2-TO-5BNC cable and PLS-TTL-CABLE required
Video input BNC of IMG-7W2-TO-5BNC cable should be connected to video out BNC
connector of camera
The connections between the DB-37 connector of the PLS-TTL-CABLE and the 12-pin
connector of the camera are as in internal fast reset mode.
TTL external trigger source should be connected to the TTL Trigger input of the IMG-7W2-
TO-5BNC cable
by Matrox Electronics System, Ltd. is believed to be accurate and reliable. Please verify all interface connections with camera documentation or manual. Contact your local sales representative or Matrox Sales office or Matrox Imaging Applications at 514-822-6061 for assistance.
Corporate Headquarters:Corporate Headquarters: Sales Offices:Sales Offices: Canada and U.S.A.Canada and U.S.A. Matrox Electronic SystemsMatrox Electronic Systems Ltd.Ltd.
1055 St.Regis Blvd. Dorval, Quebec, Canada H9P 2T4 Tel: (514) 685-7230 Fax: (514) 822-6273
U.K.U.K. Matrox (UK) Ltd.Matrox (UK) Ltd.
Sefton Park, Stoke Poges Buckinghamshire U.K. SL2 4JS Tel: +44 (0) 1753 665500 Fax: +44 (0) 1753 665599
FranceFrance Matrox France SARLMatrox France SARL
2, rue de la Couture, Silic 225 94528 Rungis Cedex Tel: (0) 1 45-60-62-00 Fax: (0) 1 45-60-62-05
GermanyGermany Matrox GmbHMatrox GmbH
Inselkammerstr.8 D-82008 Unterhaching Germany Tel: 089/614 4740 Fax: 089/614 9743
Asia PacificAsia Pacific Matrox Asia Liaison OfficeMatrox Asia Liaison Office
Rm. 1901, 19/F, Workington Tower, 78 Bonham Strand E., Sheung Wan, Hong Kong. Tel: 852.2877.5387 Fax: 852.2537.9530
PUL-CID-050
5
Loading...