Matrix G7-S12 Instructions Manual

G7 SINGLE-STATION STRENGTH
PECTORAL FLY
MAT RIX F ITN ESS S YSTE MS | 16 00 LA NDM ARK D RIV E COT TAGE G ROV E W I 535 27 USA
To ll Fr ee
86 6.6 93.4 863
ma tr ix fi tne ss .c om Fa x
PAR T # 00 000 882 10
REV. 1.0
IMPORTANT SAFETY INFORMATION
It is the sole responsibility of the purchaser of MATRIX Fitness Systems products to instruct all individuals, whether they
are the end user or supervising personnel on proper usage of the equipment.
It is recommended that all users of MATRIX Fitness Systems exercise equipment be informed of the following information
prior to its use.
PROPER USAGE
Do not use any equipment in any way other than designed or intended by the manufacturer. It is imperative that MATRIX
Fitness Systems equipment be used properly to avoid injury.
Keep hands and feet clear at all times from moving parts to avoid injury.
CHECK FOR DAMAGED PARTS
1. DO NOT use any equipment that is damaged and or has worn or broken parts. Use only replacement parts supplied by
your country’s local MATRIX Fitness Systems dealer.
2. MAINTAIN LABELS AND NAMEPLATES: Do not remove labels for any reason. They contain important information.
If unreadable or missing, contact your MATRIX Fitness Systems dealer for a replacement.
3. SECURING EQUIPMENT: All equipment MUST be secured to the floor to stabilize and eliminate rocking or tipping over.
This must be performed by a licensed contractor.
4. MAINTAIN ALL EQUIPMENT: Preventative maintenance is the key to smooth operating equipment as well as keeping
your liability to a minimum. Equipment needs to be inspected at regular intervals.
5. Ensure that any person(s) making adjustments or performing maintenance or repair of any kind is qualified to do so.
MATRIX Fitness Systems dealers will provide service and maintenance training at our corporate facility upon request.
WARNING: SERIOUS INJURY CAN OCCUR ON THIS EQUIPMENT. FOLLOW THESE PRECAUTIONS TO
AVOID INJURY!
1. Never allow children on selectorized strength equipment. Teenagers must be supervised at all times while using
this equipment.
2. All warnings and instructions should be read and proper instruction obtained prior to use.
3. Cease exercise if you feel faint or dizzy. Obtain a medical exam before beginning an exercise program
4. Keep body, hair, clothing and fitness accessories free and clear of all moving parts.
5. Inspect the machine before use. DO NOT use machine if it appears damaged or inoperable.
6. Check to see that the selector pin is completely inserted into the weight stack.
7. NEVER use the machine with the weight stack pinned in an elevated position.
8. Never use dumbbells or other means to incrementally increase the weight resistance. Only use the means provided
directly from the manufacturer.
9. This equipment should only be used in supervised areas where access and control are regulated by the owner.
PECTORAL FLY PLACARD
ACTION FREQUENCY
Clean Upholstery Daily
Inspect Cables Daily
Clean Guide Rods Monthly
Inspect Hardware Monthly
Inspect Frame Bi-Annually
Clean Machine As Needed
Clean Grips As Needed
Lubricate Guide Rods As Needed
Upholstery & Grips should be cleaned with a non-ammonia based cleaner (like Simple Green) or a mild soap and water.
Guide rods should be lubricated with Teflon based lubricant. Apply the lubricant to a cotton cloth and then apply up and
down the guide rods.
MAINTENANCE CHECKLIST
PRODUCT SPECIFICATIONS
TECH SPECS
Overall dimensions 63”L X 47”W x 52”H
Weight 592 lbs
Shipping weight 638 lbs
WARRANTY (Valid in USA only)
Frame (not coatings) 10 years
Structural parts 10 years
Weight stacks 5 years
Pulleys 5 years
Pivot bearings 5 years
Any items not specified 3 years
Labor (excluding upholstery/cables/grips) 3 years
Upholstery/grips/springs 1 year
pec_fly_091102.indd 1 11/2/09 2:43 PM
G7-S12 PECTORAL FLY
UNPACKING G7-S12 PECTORAL FLY
Thank you for purchasing a MATRIX Fitness product. This machine is an EN957-1 and E9576-2 complaint Class S product. Your MATRIX G7-S12 PECTORAL FLY is inspected before it is packaged. It is shipped in multiple pieces to facilitate the compact packaging of the machine. Prior to assembly, confirm all the components by matching them with the exploded diagrams. The weight stack is shipped in separate packaging to reduce the weight of this box. Carefully unpack the unit from this box and dispose of the packing materials in accordance with your local laws.
CAUTION
The weight of the G7-S12 PECTORAL FLY is 214 lbs. (97 kg) not including the weight stack. The weight stack tower is packaged completely assembled for ease of installation; use extra caution when removing from its pallet during assembly. The weight stack for this machine is 378 lbs. (174.4 kg). To avoid injury to yourself and prevent damage to the frame components, be sure to have proper assistance removing the frame pieces from this box. Please be sure to install the equipment on a stable base, properly level the machine and leave at least two feet of clearance to enter and exit the machine. Maximum user weight for this machine is 300 lbs.
INCLUDED TOOLS REQUIRED FOR ASSEMBLY
3MM L-Shaped Allen Wrench 4MM L-Shaped Allen Wrench 5MM L-Shaped Allen Wrench 6MM L-Shaped Allen Wrench 8MM L-Shaped Allen Wrench 10MM L-Shaped Allen Wrench Phillips Screwdriver 8MM Open-End Wrench 17MM Open-End Wrench
If any items are missing please contact your country’s local MATRIX dealer for assistance.
0mm 10 20 30 40 50 60 70 80 90 100 1
10 120 130 140 150 160
Cable Detail
Step 1
Flat Washer(M10) Lock Washer(M10)
F16 F17 F18
4Q11 Z02 Z05 Z07
Screw (M10X30L) 10
Nylon Nut (M10)
10Arc-Flat Washer
Screw (M10X75L)
8
6
4
2 Z15 2Screw (M10X135L)
Screw (M8X75L)
Lift the aluminumn wing and top cover, then take apart the front and rear sheilds. Q11 bolts won't be used anymore for the wing and cover re-assembly.
Item Description Qty
A
Q11
Q11
Q11
Q11
60
A
Step 2
Frame Detail
Item QtyDescription
Z02
Z01 4
Z11
Z02
D37
B22
Z11
Z02
Z02
D37
B22
Z11
Z02
Z11
Z02
Z01
D37
B22
Z01
D37
B22
B22
B23
B22
B23
B22
B23
B23
B22
B22
D37
Z01
Z02 8
D37 8
B22 12
B23 4
Z11 4
Screw (M10X75L) Screw (M10X30L)
Lock Washer(M10)
Flat Washer(M10)
Nylon Nut (M10) Arc-Flat Washer
Step 3
Arm Detail
Item Description Qty
Z11
Z13
Z32
Z27
D22
Z26
Z11
Z13
Z32
Z27
D22
Z26
Z13 Screw (M8X60L) 4 Z26 Screw (M8X20L) 2 Z11 Stopper Bolt 2 D22 Pulley Cover 2 Z27 C Clamp 2 Z32 Flat Washer(M26) 2
Step 4
Pad Detail
Item Description Qty
Z04
Z04
Z04
Z05
Z05
Z04
Z04 Screw (M10X75L) 4 Z05 Screw (M10X20L) 4
Step 5
Cover Detail
Screw (M8X60L) 4
Item Description Qty
Lift the wing and top cover,then assemble the front and rear shields to the frame.
Rubber Pad
Fixing Plate
Adjustable
60
Z17
Z17
Z17
Z17
Z17
pec_fly_091102.indd 2 11/2/09 2:43 PM
Loading...