The FMS - 12051 Motion sensor is a surface mount ceiling sensor, and utilises infrared technology to detect and identify motion, night and day.
Upon detection, the connected lighting load will illuminate for a user determined period of time.
SPECIFICATIONS
Max 7 minutes
Rated Load: 1200W (Incandescent)
300W (Fluro) Detection distance: 12m max Detection range: 180° Installation height: 1.8m - 2.5m Manual Override: No Weatherproof Rating: IP44 Warranty: 1 year
INSTALLATION
Note: All electrical connections relating to this installation must be carried out by a suitably qualied and registered electrician.
The sensor should not be installed outside.
FMS-12051 MOTION SENSOR INSTRUCTIONS
Fig.1
SET UP AND ADJUSTMENT
1. Adjust the TIME setting anti clockwise to minimum (10s)
2. Adjust the LUX setting clockwise to maximum.
3. Switch the power on. (The control load will not work immediately, as it requires 5-30 seconds to preheat.
4. The sensor will activate again, 5 - 15 seconds later, once the rst switching cycle is completed.
5. If testing when the ambient light is greater than 3 LUX, the initial switch cycle will not continue to operate. In this instance, cover the detection window with a dark object, such as a cloth. It is normal for the cycle to stop within 5-15 seconds of completion of the initial signal.
PROBLEM POSSIBLE SOLUTION
Lights do not turn on
Check the power is on Check the bulbs and xtures are working correctly Check wiring is correct Ensure LUX setting is set for a darker setting than present
Lights do not switch off
Make sure unit is wired correctly. Ensure there is not a continuous signal in the detection eld. Ensure the time delay is set on the appropriate setting.
Lights do not switch on
Make sure there are no reective sources in the detection eld Check detection window is clear Check installation height and detection distance is in the parameters.
TROUBLESHOOTING
WIRING DIAGRAM
As with all PIR motion sensors, the FMS - 12051 must be positioned away from any sources of heat (such as extractor fans, dryers, any air conditioning or heating registers, etc.) Reective surfaces and overhanging branches may also cause false activation.
1. Isolate the power
2. Select a suitable location to install the unit by considering points in previous sections and the units detection range and direction
3. Remove the housing cover by loosening the two screws. (Fig 1)
4. Place the back housing cover onto the surface and mark the position of the mounting holes.
5. Drill the holes and insert wall plugs into these holes, and x back housing cover to surface.
LN