mastro ABH3003, ACH3 Series, ABH3004, ABH3005, ABH3006 Instructions For Installation, Use And Maintenance Manual

...
Page 1
004_03
Instructions for installation, use and maintenance
ELECTRIC FRY-TOP
04/2006
ACH3001 · ACH3002 · ACH3003 ACH3004 · ACH3005 · ACH3006 ACH3007
ACH3018 · ACH3019 · ACH3020
ABH3001 · ABH3002 · ABH3003 ABH3004 · ABH3005 · ABH3006 ABH3007 · ABH3008 · ABH3009
Page 2
004-03 - Electric fry-top
2
Models and dimensions page 3
Technical data 9
Installation instructions 10
Installation 10 Legal and technical requisites 10 Installation 10 Wiring 10 Unipotential 10 Start-up 10
Using the appliance 11
Ignition 11 Special precautions 11
Cleaning and taking care
of the appliance
11 What to do if not using the appliance for a long time 11 What to do if something goes wrong 11
Maintenance 11
WEEE Directive 11
Wiring diagrams 12-15
Warning 16
INDEX
Page 3
BCDA BCDA
BA BA
C
D
004-03 - Electric fry-top
3
ABH30004
400 x 650 x 300 (440) Weight approx. 35 kg
ABH30009
600 x 650 x 300 (440) Weight approx. 48 kg
ABH30001/2/3
400 x 650 x 300 (440) Weight approx. 35 kg
ABH30005/6
600 x 650 x 300 (440) Weight approx. 48 kg
Main switch Fat tray Pilot lamp (voltage) Pilot lamp (resistances)
Dimensions
A B C D
Page 4
A
A
B
C
D
A
B
C
D
A
004-03 - Electric fry-top
4
Main switch Fat tray Pilot lamp (voltage) Pilot lamp (resistances)
400 x 700 x 870 (1080) Weight approx. 69 kg
600 x 700 x 870 (1080) Weight approx. 82 kg
ACH30001/2/3
400 x 700 x 870 (1080) Weight approx. 69 kg
600 x 700 x 870 (1080) Weight approx. 82 kg
Dimensions
A B C D
Page 5
BCDA ADC
CDA
B
CDA
A
D
D
A
C
C
B
B
A
C
D
A
C
D
004-03 - Electric fry-top
5
600 x 650 x 300 (440) Weight approx. 48 kg
800 x 650 x 300 (510) Weight approx. 70 kg
800 x 650 x 300 (440) Weight approx. 70 kg
ABH30007
600 x 650 x 300 (440) Weight approx. 48 kg
Main switch Fat tray Pilot lamp (voltage) Pilot lamp (resistances)
Dimensions
A B C D
Page 6
BCDA
CDA
A
C
DAD
C
ADCB
C
ADCB
A
A
004-03 - Electric fry-top
6
600 x 700 x 870 (1080) Weight approx. 82 kg
600 x 700 x 870 (1080) Weight approx. 82 kg
ACH30004/5
800 x 700 x 870 (1080) Weight approx. 102 kg
800 x 700 x 870 (1080) Weight approx. 102 kg
Main switch Fat tray Pilot lamp (voltage) Pilot lamp (resistances)
Dimensions
A B C D
Page 7
BCDA
B
DAC
BA
BA
004-03 - Electric fry-top
7
400 x 700 x 300 (440) Weight approx. 35 kg
600 x 700 x 300 (440) Weight approx. 48 kg
400 x 700 x 300 (510) Weight approx. 35 kg
ACH30018/19/20
600 x 700 x 300 (510) Weight approx. 48 kg
Main switch Fat tray Pilot lamp (voltage) Pilot lamp (resistances)
Dimensions
A B C D
Page 8
DAC
BCDA
BA
AD
DA
CCB
AD
DA
CCB
004-03 - Electric fry-top
8
600 x 700 x 300 (440) Weight approx. 48 kg
800 x 700 x 300 (510) Weight approx. 70 kg
600 x 700 x 300 (510) Weight approx. 48 kg
800 x 700 x 300 (510) Weight approx. 70 kg
Main switch Fat tray Pilot lamp (voltage) Pilot lamp (resistances)
Dimensions
A B C D
Page 9
004-03 - Electric fry-top
9
Technical data
The data plate is located on the rigth hand side of the con­trol panel and contains all the data needed for connecting it up to the mains electricity supply.
0051
TIPO/TYPE
CAT/KAT GAS/GAZ G30 G31 G20 G25
II2H3B/P P mbar 30 30 20 -
II2H3+ P mbar 30 37 20--
II2H3+ P mbar 28 37 20 -
25II2L3B/P P mbar 30 30
II2ELL3B/P P mbar 50 50 20 20
II2E+3+ P mbar 28 37 20 25
II2H3B/P P mbar 50 50 20 -
I2E P mbar - - 20 -
--II2H3B/P P mbar 30 30
II2H3+ P mbar 28 37 20 -
--
--
I3B/P P mbar 30 30
I3+ P mbar 28 37
SE FI DK CZ SK SI
IT CH PT
ES IE GB GR
NL
DE
FR BE
AT CH
LU
EE LV LT
EE LV LT
NO MT CY IS HU
CY
MOD.
MOD.
ART.
N.
N.
Qn kW
m3/h
MADE IN ITALY
Predisposto a gas: - Gas preset: - Prevu pour gaz:
Eingestelt für Gas: - Preparado para gas: -
Geschuckt voor:
V AC kW Hz
THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS BEFORE INSTALLING AND USING THE APPLIANCE. THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.
Model
ABH30004
ABH30001/2/3
ACH30001/2/3
ABH30009
ABH30005/6
ACH30018/19/20
ABH30007/8
ACH30004/5/6/7
FRY-TOP
Dim.: LxWxH (total h)
of work surface
400 x 650 x 300 (440)
400 x 700 x 300 (510)
400 x 700 x 870 (1080)
400 x 650 x 300 (440)
400 x 700 x 300 (510)
400 x 700 x 870 (1080)
600 x 650 x 300 (440)
600 x 700 x 300 (510)
600 x 700 x 870 (1080)
600 x 650 x 300 (440)
600 x 700 x 300 (510)
600 x 700 x 870 (1080)
600 x 650 x 300 (440)
600 x 700 x 300 (510)
600 x 700 x 870 (1080)
600 x 650 x 300 (440)
600 x 700 x 300 (510)
600 x 700 x 870 (1080)
800 x 650 x 300 (440)
800 x 700 x 300 (510)
800 x 700 x 870 (1080)
800 x 650 x 300 (440)
800 x 700 x 300 (510)
800 x 700 x 870 (1080)
Voltage rating
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
230 V 3 AC or 400 V 3N AC
Power
5.0 kW
5.0 kW
5.0 kW
5.0 kW
5.0 kW
5.0 kW
6.75 kW
6.75 kW
6.75 kW
6.75 kW
6.75 kW
6.75 kW
6.75 kW
6.75 kW
6.75 kW
6.75 kW
6.75 kW
6.75 kW
10 kW
10 kW
10 kW
10 kW
10 kW
10 kW
Lead wire / Section
4 x 1.5 mm
2
or 5 x 1.5 mm
2
4 x 1.5 mm
2
or 5 x 1.5 mm
2
4 x 1.5 mm
2
or 5 x 1.5 mm
2
4 x 1.5 mm
2
or 5 x 1.5 mm
2
4 x 1.5 mm
2
or 5 x 1.5 mm
2
4 x 1.5 mm
2
or 5 x 1.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
4 x 2.5 mm
2
or 5 x 2.5 mm
2
Page 10
004-03 - Electric fry-top
10
Before beginning installation, remove all packaging from the appliance. Some parts are protected with an adhesive film which should be carefully removed. Any remnants of glue should be thoroughly cleaned using suitable substances such as benzine. Under no circum­stances should abrasive substances be used. Fit the legs to the appliance; the appliance must be level­led using a spirit level. Slight irregularities can be levelled by adjusting the feet themselves. With table models, make sure that the base chosen is ca­pable of supporting the weight of the appliance. The main switch or plug should be located in the vicinity of the ap­pliance and easy of access. We recommend installing the machine under a range hood so that all the fumes are re­moved as quickly as possible. If the appliance is to be in­stalled near walls, dividing walls, kitchen equipment or de­corative pannelling, these should be in non-inflammable material or covered with non-inflammable material. Make sure that all fire prevention standards and safety pre­cautions are strictly adhered to.
Warning!
MODEL ACH30001/2/3 if this model is going to be mounted on its own, it must be fixed to the floor. Fixing accessories are included. The appliance should be fitted following the indica­tions given in the drawing below.
Legal and technical requisites
When installing the appliance, the following safety stan­dards must be adhered to:
- Local accident prevention standards
- Current CEI standards.
Installation
Installation, start-up and maintenance should only be car­ried out by expert personnel. All work required to install the appliance should be carried out in compliance with all local standards and regulations. The manufacturers decli­ne all responsibility where poor performance is due to in­correct installation in disregard of the above conditions.
Warning!
In compliance with international regulations, when connecting the appliance to the mains power supply, a device with a minimum aperture of 3 mm between con­tacts must be fitted upstream of the appliance, al­lowing omnipolar disconnection of the appliance from the mains.
Wiring
When choosing the lead wire, make sure it has the fol­lowing characteristics: it should be at least of the H07 RN­F type and its section should be large enough for the ap­pliance (see "Technical specifications and dimensions", page 9). Wire entry on top models is on the back wall, and under­neath all other models. In both cases the terminal board is at the front, behind the control panel. Pass the wire through the core hitch and wire clamp, plug the leads into their terminals on the board and secure them. The earth lead must be a little longerthan the others so that it is the last lead to disconnect if the wire clamp breaks.
Unipotential
The appliance must be connected up to a unipotential sy­stem. The connection screw is located on all top models at the back on the right hand side, while in other models it is located underneath the appliance on the right hand side. It is labelled.
Warning!
The manufacturers cannot be held responsible for any damage due to inadequate or incorrect installation. Under such circumstances the guarantee will be consi­dered null and void.
Start-up
Before using the appliance for the first time, thoroughly clean the grilling plate (see “Cleaning and Taking Care of the Appliance”) to remove the protective film of mineral oil applied in the factory. Check installation and wiring, then turn the appliance on following the instructions below, and leave on, empty, for about 15 mins.
INSTALLATION INSTRUCTIONS
RETRO BACK ARRIERE RÜCKSEITE
1
Page 11
004-03 - Electric fry-top
11
Warning!
- Beware of inexpert handling!
Ignition
Check that the fat tray is in place. Turn on the main switch upstream of the appliance. Turn the thermostat to any po­sition between 50°C and 300°C; the pilot lights will come on; the green one shows that the appliance is on, the yel­low one shows that the resistances are on. As soon as the required temperature is reached, the yel­low light goes off. To turn the appliance off, simply turn the knob back to '0'.
Note: Appliances ABH30007/8, ACH30004/5/6/7 have
2 separate, independent cooking areas.
Special precautions
It is recommanded to keep cleaning the plate during use, using a scraper or a dampf cloth to remove particles of food which could start smoking and causing unpleasant smells.
CLEANING AND TAKING CARE OF THE MACHINE
Warning!
Never clean the appliance with jets of water, whether direct or pressurised. Never clean the appliance before it has cooled down.
Before starting to clean the appliance, disconnect from the mains. Remove, empty and wash the fat tray. Remove any remaining particles of food using the scaper or a dampf cloth. The plate and steel parts should be washed in warm water using a neutral detergent. Rinse the plate with a soft cloth to get rid of all traces of detergent. Thoroughly dry the appliance. Avoid using abrasive or corrosive detergents which could damage the steel. After cleaning the appliance, grease the plate with vegeta­ble oil.
What to do if not using the appliance for a long time
Thoroughly clean and dry the machine as described. Disconnect the power supply. Grease the plate with vegetable oil.
USING THE APPLIANCE
What to do if something goes wrong
If anything goes wrong, immediately turn the appliance off, then turn off the power supply at the switch located upstream of the appliance, and call the aftersales depart­ment.
MAINTENANCE
All maintenance should be carried out by qualified per­sonnel only. Before carrying out any maintenance work, unplug the appliance or turn off the switch upstream of the appliance.
THE 2002/96/EC DIRECTIVE (WEEE): information to users
This informational note is meant only for owners of equipment marked with the symbol shown in Fig. A on the adhesive label featuring the techni­cal specifications applied on the actual product
(the label also giving the serial number).
This symbol indicates that the product is classified, accor­ding to the regulations in force, as an item of electrical and electronic equipment and conforms to EU Directive 2002/96/EC (WEEE) meaning that, at the end of its service life, it must be treated separately from domestic waste, i.e. it must be handed in free of charge to a separate waste electrical and electronic equipment collection centre or re­turned to the reseller when buying a new equivalent item of equipment.
The user is responsible for delivering the unit at the end of its life to the appropriate collection facilities. Failure to do so shall result in the user being subject to the penalties prescribed by the legislation in force on waste. Suitable separated collection so that the unit no longer used can be sent off for environmentally compatible recy­cling, treatment and disposal helps avoid possible negati­ve effects on the environment and on health and facilitates the recycling of the product's component materials.
For more detailed information on available collection sy­stems, contact the local waste disposal service or the shop you purchased the unit from. Producers and importers fulfil their responsibility for envi­ronmentally compatible recycling, treatment and disposal both directly and by joining a collective scheme.
Page 12
400 V 3N AC
B1
F1
F2
1mA 2 345
6
123456
L1L2 L3 N
P1P2 P3 12 22 32
11 21 31
P4
H2 H1
R1 R1 R1
1234
230V 3 AC
1mA2 345
6
L1 L2 L 3
12
3
12 22 32
4456
R1
ABH30001/2/3 ACH30001/2/3 ABH30004
mA B1 F1 H1 H2 R1 F2
Line input terminal board Switch Thermostat Green pilot lamp Orange pilot lamp Resistance 1650 W Safety thermostat
Total power:
5000 W
004-03 - Electric fry-top
12
Wiring diagrams
Page 13
004-03 - Electric fry-top
13
400 V 3N AC
B1
F1
F2
1mA 2 345
6
123456
L1L2 L3 N
P1P2 P3 12 22 32
11 21 311234
P4
H2 H1
R1 R1 R1 R1
12 22 32
11 21 31
78
230V 3 AC
1mA2 345
6
L1 L2 L 3
12
3
12 22 32
456
78
R1
ABH30009 ABH30005/6 ACH30018/19/20
mA B1 F1 H1 H2 R1 F2
Line input terminal board Switch Thermostat Green pilot lamp Orange pilot lamp Resistance 1650 W Safety thermostat
Total power:
6750 W
Wiring diagrams
Page 14
004-03 - Electric fry-top
14
430 V 3N AC
230V 3 AC
1mA2 345
6
L1L2 L3
B1
F1
F2
1mA 2 345
6
1234
L1L2 L3 N
P1
P2 P3 12 22 32
11 21 31
P4
H2 H1
R1 R1
1234
B1
F1
1234
P1
P2 P3 12 22 32
11 21 31
P4
H2 H1
R1 R1
1234
ABH30007/8
mA B1 F1 H1 H2 R1 F2
Line input terminal board Switch Thermostat Green pilot lamp Orange pilot lamp Resistance 1650 W Safety thermostat
Total power:
6750 W
Wiring diagrams
Page 15
004-03 - Electric fry-top
15
400 V 3N AC
B2
F1
F2
1mA 2 345
6
123456
L1L2 L3 N
P1P2 P3 12 22 32
11 21 31
P4
H2 H1
R1 R1 R1
31 21 11
32 22 12
1234
B2
F1
F2
123456
P1P2 P3 12 22 32
11 21 31
P4
H2 H1
R1 R1 R1
31 21 11
32 22 12
1234
230V 3 AC
1mA2 345
6
L1L2 L3
12
3
12 22 32
456
R1
ACH30004/5/6/7
mA B1 F1 H1 H2 R1 F2
Line input terminal board Switch Thermostat Green pilot lamp Orange pilot lamp Resistance 1650 W Safety thermostat
Total power:
10000 W
Wiring diagrams
Page 16
004-03 - Electric fry-top
16
WARNING
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS BOOKLET DUE TO COPYING OR PRINTING ERRORS.
DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO­VEMENT, THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY.
THE MANUFACTURER CANNOT BE HELD RESPONSI­BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA­NUAL ARE NOT OBSERVED.
Loading...