MASTERVOLT MLI Ultra 1250 12V/100Ah Lithium Pack, ChargeMaster PLUS CZone Charger / 24 V / 20 A / 3 charging outputs, ChargeMaster PLUS CZone Charger / 12 V / 35 A / 3 charging outputs, ChargeMaster PLUS CZone Charger / 24 V / 30 A, ChargeMaster PLUS CZone Charger / 12 V / 50 A / 3 charging outputs Manual

Page 1
CHARGEMASTER PLUS
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3
AUTOMATIC BATTERY CHARGER
10000016594/03
For the latest version of this manual, visit our website:
Ga om deze handleiding in andere talen te downloaden naar onze website:
Um diese Anleitung in anderen Sprachen herunterzuladen, besuchen Sie bitte unsere Website:
Pour télécharger ce manuel dans d'autres langues, consultez notre site Web :
Para descargar este manual en otros idiomas, visite nuestro sitio web:
Per scaricare questo manuale in altre lingue, visitare la pagina del prodotto sul nostro sito Web:
www.mastervolt.com
Page 2
2
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
TABLE OF CONTENTS
1 GENERAL INFORMATION ......................... 3
1.1 Use of this manual .................................... 3
1.2 Liability ....................................................... 3
1.3 Warranty .................................................... 3
1.4 Disclaimer .................................................. 3
1.5 Identification label .................................... 3
1.6 Correct disposal of this product ............. 3
2 SAFETY INSTRUCTIONS ........................... 4
2.1 General ...................................................... 4
2.2 Explosive gases ........................................ 4
2.3 Personal precautions ............................... 5
2.4 Warnings regarding the use of batteries 5
2.5 Charger location ....................................... 5
2.6 DC connection precautions .................... 5
2.7 When battery is installed in vehicle ....... 6
2.8 When battery is outside vehicle ............. 6
2.9 Preparing to charge ................................. 6
2.10 Grounding instructions ............................ 7
2.11 Warning regarding life support
applications ............................................... 7
3 INSTALLATION .......................................... 8
3.1 Unpacking ................................................. 8
3.2 Location ..................................................... 8
3.3 Wiring ......................................................... 8
3.3.1 DC wiring ......................................... 8
3.3.2 AC wiring ......................................... 9
3.3.3 AC safety grounding ...................... 9
3.3.4 Network wiring
(CZone/MasterBus) ................................ 10
3.4 Batteries ................................................... 10
3.5 Things you need ..................................... 10
3.6 Overview of the connection
compartment ........................................... 11
3.7 Connection example .............................. 12
3.8 Installation step-by-step ......................... 13
3.9 Commissioning after installation .......... 15
4 SETTINGS ................................................. 16
4.1 DIP switch settings ................................. 16
4.2 MasterBus configuration ....................... 16
4.2.1 Monitoring ..................................... 17
4.2.2 Alarms ............................................ 17
4.2.3 History ............................................ 18
4.2.4 Configuration settings.................. 18
4.2.5 Events – System automation ...... 19
4.2.6 Current control ............................. 20
4.3 MasterShunt ............................................ 21
4.4 Lithium-ion Battery MLI Ultra ................ 21
4.5 CZone configuration .............................. 21
5 OPERATING INSTRUCTIONS .................. 22
5.1 Introduction ............................................. 22
5.2 Switching on / off .................................... 22
5.3 Status display .......................................... 22
5.4 The 3-step+ charge process ................. 23
5.4.1 Charge voltages ........................... 24
5.4.2 Pre-float ......................................... 24
5.4.3 Temperature compensated
charging ................................................... 24
5.4.4 Flat battery support ...................... 24
5.5 DC OUT ................................................... 24
5.6 Maintenance ............................................ 24
5.7 Storage .................................................... 25
6 TROUBLE SHOOTING .............................. 26
7 TECHNICAL DATA ................................... 28
7.1 Specifications 12V models .................... 28
7.2 Specifications 24V models .................... 29
7.3 Dimensions .............................................. 30
7.4 Characteristics ........................................ 30
Page 3
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
3

1 GENERAL INFORMATION

1.1 Use of this manual

This manual serves as a guideline for the safe and effective operation and maintenance of the following ChargeMaster Plus models:
Part number
Model
44310355
12/35-3
44310505
12/50-3
44320205
24/20-3
44320305
24/30-3
These models are further referred to as ChargeMaster Plus”.

1.2 Liability

Mastervolt can accept no liability for:
Consequential damage resulting from the use
of the ChargeMaster Plus.
Possible errors in the included manual and
the consequences of these.
Use that is inconsistent with the purpose of
the product.

1.3 Warranty

The Mastervolt product warranty covers the ChargeMaster Plus for the first two years after the purchase date, on the condition that the product is installed and used according to the instructions in this manual.
Installation or use that do not comply with these instructions may result in under performance, damage or failure of the product and may void this warranty. The warranty is limited to the cost of repair and/or replacement of the product. Costs of labor or shipping are not covered by this warranty.

1.4 Disclaimer

Our products are subject to continual development and improvement. Therefore, additions or modifications to the products may cause changes to the technical data and functional specifications. No rights can be derived from this document. Please consult our most current Terms & Conditions of Sale.

1.5 Identification label

The following picture is only an example!
Part number Serial number.
Figure 1: Identification label
The identification label is located at the right­hand side of the ChargeMaster Plus. Important technical information required for service, maintenance & secondary delivery of parts can be derived from the identification label.
CAUTION!
Never remove the identification label. This will void the warranty.

1.6 Correct disposal of this product

This product is designed and manufactured with high quality materials and components, which can be recycled and reused.
Please be informed about the local separate collection system for electrical and electronic products.
Please act according to your local rules and do not dispose of your old products with your normal household waste. The correct disposal of your old product will help prevent potential negative consequences to the environment and human health.
Page 4
4
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

2 SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
WARNING!
Read the entire manual before using the ChargeMaster Plus. Keep this manual in a secure place.
This chapter describes important safety and operating instructions for use of a ChargeMaster Plus in residential, recreational vehicle (RV) and marine applications.

2.1 General

1 The appliance is not to be used by children or
persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
2 This appliance can be used by children aged
from 8 years and above and persons with reduced physical, sensory or mental capa­bilities or lack of experience and knowledge, if they have been given supervision or instruc­tion concerning use of the appliance in a safe way and understand the hazards involved.
3 Children shall not play with the appliance. 4 Cleaning and user maintenance shall not be
made by children without supervision.
5 To reduce the risk of electric shock – Do not
expose the ChargeMaster Plus to rain, snow, spray, moisture, excessive pollution and condensing circumstances. To reduce risk of fire hazard, do not cover or obstruct the ventilation openings. Do not install the ChargeMaster Plus in a non-ventilated room, as overheating may result.
6 Use of an attachment or spare part not
recommended or sold by Mastervolt may result in a risk of fire, electric shock, or personal injury.
7 UL 1236 requirements do not cover investiga-
tion of charging Lithium-ion type batteries.
8 The ChargeMaster Plus is designed to be
permanently connected to an AC and DC electrical system. Installation of, and work on the ChargeMaster Plus, may be carried out only by qualified and trained personnel,
consistent with the locally applicable standards and regulations.
9 Make sure that all wiring is properly installed,
in good electrical condition, and correctly sized to match the AC ampere rating of the ChargeMaster Plus. Check the wiring on a regular base, at least once a year. Do not use the ChargeMaster Plus when the wiring is undersized or damaged.
10 Do not operate the ChargeMaster Plus if it has
received a sharp blow, been dropped, or otherwise damaged in any way; take it to a qualified serviceman.
11 Except for the connection compartment, see
chapter 3, the ChargeMaster Plus may not be opened or disassembled. There are no serviceable parts inside the cabinet. Take it to a qualified, authorized and trained serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire.
12 To reduce risk of electric shock, disconnect
the ChargeMaster Plus from both AC and DC electrical system before attempting any maintenance or cleaning. Turning off controls will not reduce this risk. Be sure that third parties cannot reverse the measures taken.
13 The ChargeMaster Plus must be provided
with an equipment-grounding conductor to the AC input ground terminal. Grounding and all other wiring must comply with local codes and ordinances.
14 Short circuiting or reversing polarity will lead
to serious damage to batteries, ChargeMaster Plus, wiring as well as accessories. Fuses cannot prevent damage caused by reversed polarity and the warranty will be void.
15 In case of fire, you must use the fire extin-
guisher which is appropriate for electrical equipment.
16 If applied in a marine application in the United
States, external connections to the ChargeMaster Plus shall comply with the United States Coast Guard Electrical Regulations (33CFR183, Sub part I).

2.2 Explosive gases

1 WARNINGRISK OF EXPLOSIVE
GASES. WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS.
Page 5
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
5
BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING THE ChargeMaster Plus, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY.
2 To reduce risk of battery explosion, follow
these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of the battery. Review cautionary marking on these products and on engine.
3 DANGER: To reduce the risk of
explosion – Never use the ChargeMaster Plus in situations where there is danger of gas or dust explosion or area in which ignition-protected equipment is required.

2.3 Personal precautions

1 Consider having someone close enough by to
come to your aid when you work near a lead­acid battery.
2 Have plenty of fresh water and soap nearby in
case battery acid contacts skin, clothing, or eyes.
3 Wear eye and clothing protection. Avoid
touching eyes while working near battery.
4 If battery acid contacts skin or clothing, wash
immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately.
5 NEVER smoke or allow a spark or flame in
vicinity of battery or engine.
6 Be extra cautious to reduce risk of dropping a
metal tool onto battery. It might spark or short­circuit battery or other electrical part that may cause explosion.
7 Do not wear watches, bracelets, necklaces or
other metal objects when working on batteries.
2.4 Warnings regarding the use of
batteries
1 Only use the ChargeMaster Plus for charging
Lead-Acid or lithium-ion batteries and the
supply of consumers attached to these batteries, in permanent systems. Do not use the ChargeMaster Plus for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to persons and damage to property. Make sure lithium-ion batteries used for this charger are certified to EN standards.
2 NEVER charge non-rechargeable batteries. 3 NEVER charge a frozen battery. 4 Excessive battery discharge and/or high
charging voltages can cause serious damage to batteries. Do not exceed the recommended limits of discharge level of your batteries.
5 If it is necessary to remove a battery, always
remove grounded terminal from battery first. Make sure all accessories are off, so as not to cause an arc.
6 Be sure that the area around battery is well
ventilated while battery is being charged. Refer to the recommendations of the battery manufacturer.
7 Batteries are heavy! It may become a
projectile if it is involved in an accident! Ensure adequate and secure mounting and always use suitable handling equipment for transportation.

2.5 Charger location

1 Never place charger directly above battery
being charged; gases from battery will corrode and damage charger.
2 Never allow battery acid to drip on charger
when reading electrolyte specific gravity or filling battery.
3 Do not operate charger in a closed-in area or
restrict ventilation in any way.
4 Do not set a battery on top of charger.

2.6 DC connection precautions

1 Connect and disconnect DC output clips only
after setting any charger switches to “off” position and removing AC cord from electric outlet. Never allow clips to touch each other.
2 Attach clips to battery and chassis as
indicated in section 2.7, steps 5 and 6, and 2.8 steps 2 through 4.
Page 6
6
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

2.7 When battery is installed in vehicle

A SPARK MAY CAUSE BATTERY EXPLOSION.
To reduce risk of a spark near battery:
1 Position AC and DC cords to reduce risk of
damage by hood, door, or moving engine part.
2 Stay clear of fan blades, belts, pulleys, and
other parts that can cause injury to persons.
3 Check polarity of battery posts. POSITIVE
(POS, P, +) battery post usually has larger diameter than NEGATIVE (NEG, N, –) post.
4 Determine which post of battery is grounded
(connected) to the chassis. If negative post is grounded to chassis (as in most vehicles), see (5). If positive post is grounded to the chassis, see (6).
5 For negative-grounded vehicle, connect
POSITIVE (RED) clip from battery charger to POSITIVE (POS, P, +) ungrounded post of battery. Connect NEGATIVE (BLACK) clip to vehicle chassis or engine block away from battery. Do not connect clip to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gage metal part of the frame or engine block.
6 For positive-grounded vehicle, connect
NEGATIVE (BLACK) clip from battery charger to NEGATIVE (NEG, N, –) ungrounded post of battery. Connect POSITIVE (RED) clip to vehicle chassis or engine block away from battery. Do not connect clip to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gage metal part of the frame or engine block.
7 When disconnecting charger, turn switches to
off, disconnect AC cord, remove clip from vehicle chassis, and then remove clip from battery terminal.
8 See operating instructions for length of
charge information.

2.8 When battery is outside vehicle

A SPARK MAY CAUSE BATTERY EXPLOSION.
To reduce risk of a spark near battery:
1 Check polarity of battery posts. POSITIVE
(POS, P, +) battery post usually has a larger diameter than NEGATIVE (NEG, N, –) post.
2 Attach at least a 24-inch-long 6-gauge (AWG)
insulated battery cable to NEGATIVE (NEG, N, –) battery post.
3 Connect POSITIVE (RED) charger clip to
POSITIVE (POS, P, +) post of battery.
4 Position yourself and free end of cable as far
away from battery as possible – then connect NEGATIVE (BLACK) charger clip to free end of cable.
5 Do not face battery when making final
connection.
6 When disconnecting charger, always do so in
reverse sequence of connecting procedure and break first connection while as far away from battery as practical.

2.9 Preparing to charge

1 If it is necessary to remove battery from
vehicle to charge, always remove grounded terminal from battery first. Make sure all accessories in the vehicle are off, so as not to cause an arc.
2 Be sure area around battery is well ventilated
while battery is being charged.
3 Clean battery terminals. Be careful to keep
corrosion from coming in contact with eyes.
4 Add distilled water in each cell until battery
acid reaches level specified by battery manufacturer. Do not overfill. For a battery without removable cell caps, such as valve regulated lead acid batteries, carefully follow manufacturer’s recharging instructions.
5 Study all battery manufacturer’s specific
precautions while charging and recommended rates of charge. Note that the ChargeMaster Plus charge specifications are based on Mastervolt batteries. Specifications for a given chemistry of a different manufacturer may vary. If connecting batteries of a different manufacturer, make sure the manufacturer's recommendations are met.
6 Determine voltage of battery by referring to
car owner’s manual and make sure that output voltage selector switch is set at correct voltage. If charger has adjustable charge rate, charge battery initially at lowest rate. Exception: For a charger not having an output voltage selector switch, determine voltage of
Page 7
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
7
battery by referring to car owner’s manual and
make sure it matches output rating of battery charger.

2.10 Grounding instructions

This battery charger should be connected to a grounded, metal, permanent wiring system; or an equipment-grounding conductor should be run with circuit conductors and connected to equipment-grounding terminal or lead on battery charger. Connections to battery charger should comply with all local codes and ordinances.
2.11 Warning regarding life support
applications
Mastervolt products are not designed to be used as component of medical equipment, unless negotiated in the form of a written agreement between customer and/or manufacturer and Mastervolt. Such agreement will require the equipment manufacturer either to contract additional reliability testing of the Mastervolt parts and/or to commit to undertake such testing as a part of the manufacturing process. Furthermore, the manufacturer must agree to indemnify and not hold Mastervolt responsible for any claims arising from the use of the Mastervolt parts in the life support equipment.
Page 8
8
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

3 INSTALLATION

During installation and commissioning, the safety instructions are applicable at all times.

3.1 Unpacking

In addition to the ChargeMaster Plus the delivery includes:
Mounting bracket to mount the ChargeMaster
Plus to a wall;
Battery temperature sensor;
Drop cable CZone/MB (1m);
MasterBus Terminator;
User and installation manual.
After unpacking, check the contents for possible damage. Do not use the product if it is damaged. If in doubt, contact your supplier
Check from the identification label (see section
1.5) whether the battery voltage is the same as the nominal output voltage of the ChargeMaster Plus (e.g. 24V battery set for a 24V battery charger).

3.2 Location

The ChargeMaster Plus is designed for indoor
use only.
Ambient temperature: -25°C ... 80°C / -13°F
176°F; (power derating above 40°C / 104°F to decrease the internal heat sink temperature).
Humidity: 0-95% non-condensing
Mount the ChargeMaster Plus vertically, with
the connecting cables downwards.
Do not expose the ChargeMaster Plus to
excessive dust, aggressive environments, ammonia or salt.
Make sure that the hot air that is developed
during operation can be discharged. The ChargeMaster Plus must be mounted in such a way that obstruction of the airflow through the ventilation openings will be prevented.
This device requires a minimum of 100mm
(4") of clearance on every side.
If added to a CZone or MasterBus network,
take the network powering into consideration.
Never place the ChargeMaster Plus directly
above the battery being charged, as gases from battery will corrode and damage the ChargeMaster Plus.
If the ChargeMaster Plus is installed in the
immediate vicinity of living areas, take into account that even though we took the highest care, the fan of the ChargeMaster Plus can produce noise when operating.
Although the ChargeMaster Plus fully
complies with all applicable EMC limits, it may still cause harmful interference to radio communication equipment. If such interfe­rence appears, it is recommended to increase the separation between the ChargeMaster Plus and the equipment, to relocate the receiving antenna or to connect the equipment to a circuit different from that to which the ChargeMaster Plus is connected.

3.3 Wiring

WARNING!
The wire sizes stated in this manual are given as guideline only. Always comply with all local rules and regulations.

3.3.1 DC wiring

Keep in mind that high current will pass through the DC wiring. Keep the cable length as short as possible, this will keep the system efficiency as high as possible. The recommended minimum cross section of the battery cables is:
ChargeMaster Plus model
DC Cable cross section:
<3m 10ft
3-5m/10­16ft
12/35-3
10 mm² 8 AWG
16 mm² 6 AWG
12/50-3
16 mm² 6 AWG
25 mm² 4 AWG
24/20-3
6 mm² 10 AWG
10 mm² 8 AWG
24/30-3
10 mm² 8 AWG
16 mm² 6 AWG
0
20
40
60
80
100
120
-50
-40
-30
-20
-10
0
102030405060708090
100
Output Power (%)
Temperature (°C)
Output Power vs Temperature
Page 9
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
9
Use the following wire colors for DC wiring color or at least different colors to make a clear distinction between the positive and negative wire from the battery:
Wire color
Meaning
Connect to:
Red
Positive
+ (POS)
Black
Negative
– (NEG)
Run the positive and negative cables next to each other to limit the electromagnetic field around the cables. The negative cable should be connected directly to the negative post of the battery bank or the ground side of a current shunt. Do not use the chassis frame as the negative conductor. Tighten securely. The positive battery cable must be fused and connected to the positive post of the battery bank.
The recommended DC fuses for DC 1/2/3 OUT are:
Model
DC fuse
Model
DC fuse
12/35-3
40 A
24/20-3
25 A
12/50-3
60 A
24/30-3
40 A
The fuse with the fuse-holder is available from your local Mastervolt distributor or Customer Service Representative.

3.3.2 AC wiring

WARNING!
On first connecting to power, make sure the ChargeMaster Plus is in a well-ventilated area as it might spark.
For a safe installation the correct wire cross
section must be applied. Don’t use a cross
section that is smaller than indicated. See the following table to select the appropriate cross section for the AC wiring (up to 6m / 20ft length):
Wire size
Max. current
Solid wire (3x)
1.5 – 6 mm
2
14 – 10 AWG
15A
Stranded wire (3x)
1.5 – 6 mm
2
14 – 8 AWG
15A
Ferruled wire (3x)
1.5 – 4 mm
2
14 – 10 AWG
15A
Connection of AC wiring and recommended wire colors:
240VAC, 50/60Hz installations:
Wire color
Meaning
Must be connected to:
Brown or black
Phase
L
Blue
Neutral
N
Green/Yellow
Earth
120VAC, 50/60Hz installations (single phase):
Wire color
Meaning
Must be connected to:
Black
Hot or Line
L
White
Neutral
N
Green
Ground
240VAC, 50/60Hz (split phase 120/240VAC):
Wire color
Meaning
Must be connected to:
Black (L1)
Hot or Line
L
Red (L2)
Hot or Line
N
Green
Ground
Note: An accessible disconnection device
(switch or circuit breaker for example) must be incorporated in the AC wiring, in accordance with wiring rules.

3.3.3 AC safety grounding

WARNING!
The ground wire offers protection only if the enclosure of the ChargeMaster Plus is connected to the safety ground. Connect the ground terminal (PE / GND) to the hull, chassis or Distribution Apparatus.
CAUTION!
According to local regulations an RCD/Breaker (also known as GFCI) must be placed in the AC input circuit of the ChargeMaster Plus.
For Australia and New Zealand, the wiring rules are in accordance with AS/NZS 3000.
Page 10
10
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

3.3.4 Network wiring (CZone/MasterBus)

The ChargeMaster Plus can be connected to a CZone or MasterBus network. Use an RJ45 Drop cable CZone/MB or MasterBus cable and daisy chain the ChargeMaster Plus to the other devices, forming a local data network. Both networks need a terminating device on both ends of the network. Do not make ring networks or T-connections.
CZone network
Points to consider:
˗ Up to 40 devices can be connected together
on a single backbone.
˗ Make sure the CZone network has two
terminating resistors, one at each open end of the backbone.
˗ The electric power for the network comes
from a battery or power supply. Make sure that it delivers enough power and is positioned as close to the middle of the backbone as possible to reduce voltage drop.
MasterBus network
Points to consider:
˗ Connections between the devices are made
by standard MasterBus cables (straight UTP). Mastervolt can supply these cables.
˗ Up to 63 MasterBus devices can be
connected together.
˗ The electric power for the network comes
from the connected devices according to the rule: 1powering / 3 non-powering. Spread the powering devices over the network.
For more details on networks, please contact your Mastervolt supplier.

3.4 Batteries

Always follow the instructions published by the battery manufacturer.
Model
Minimum
battery
capacity
MVG
(Mastervolt Gel
battery)
12/35-3
70 Ah
85
12/50-3
100 Ah
120
24/20-3
40 Ah
55
24/30-3
60 Ah
85

3.5 Things you need

Make sure you have all the parts you need to install the ChargeMaster Plus:
ChargeMaster Plus (included).
Battery temperature sensor with cable and
plug (included).
DC cables to connect the ChargeMaster Plus
to the batteries and common negative; see section 3.3.1 for specifications.
DC fuse holder with a DC fuse, to be
integrated in the positive DC cable; see section 3.3.1 for specifications.
Screws/bolts (Ø 6mm with plugs) to mount
the ChargeMaster Plus to a surface. Use mounting materials which are suitable to carry the weight of the ChargeMaster Plus.
AC cable to connect the AC input to an AC
power source. See section 3.3.2.
Batteries. See section 3.4.
Appropriate and reliable cable terminals,
cable lugs, battery terminals and cord end terminals.
For CZone setup, an RJ45-M12 Drop cable
CZone/MB (included) and a tee connector (not included). When connecting several drop cables in a similar location, use a 2-way or 4-way tee connector
For MasterBus setup, an RJ45 MasterBus
cable (not included).
We recommend as a minimum tool kit:
Socket wrench 10mm to fix the main DC
cables.
Socket wrench 10mm to fix the Safety ground
connection.
Flat blade screwdriver 1.0 × 4.0mm to fix the
screw terminals of the AC wiring.
Tools to fix the screws / bolts (Ø 6mm) with
plugs to mount the ChargeMaster Plus to a surface.
Philips screwdriver number 2 to open the
connection compartment.
Page 11
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
11

3.6 Overview of the connection compartment

1. Spring cage terminal AC input
2. Strain relief for AC wiring
3. Safety ground connection 1*
4. Safety ground connection 2*
5. Positive terminal charge output 1;
DC 1 OUT
6. Positive terminal charge output 2;
DC 2 OUT
7. Positive terminal charge output 3;
DC 3 OUT
8. Common negative output terminal
9. DIP switches
10. Network connection
(CZone/MasterBus)
11. Temperature sensor connection
Figure 2: Connections
* There are two safety ground connections. Use only one of them. For details see section 3.7 Connection
example.
Page 12
12
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

3.7 Connection example

This schematic illustrates the general placement of the ChargeMaster Plus in a circuit. It is not meant to provide detailed wiring instructions for any particular electrical installation.
Figure 3: Installation drawing of the ChargeMaster Plus
* Use only one of the two options.
When installing the AC wires, keep extra length available for the PE, ensuring the PE will be the last wire to get taut if the wire slips through the anchorage.
Notes:
- If the battery temperature remains within 15-25°C (59-77°F), connection of the battery temperature
sensor is optional.
- Lithium-ion batteries require no temperature sensor.
- If creating a parallel system of multiple ChargeMaster Plus units, the units should be excluded from any
isolation measurement system.
CZone/MasterBus
Network
RCD/Breaker
L1
N/L2
PE/GND* option 1
PE/GND* option 2
Battery
fuse
Battery
fuse
Battery
fuse
BATTERY BANK 1
(main battery bank)
BATTERY
BANK 3
BATTERY
BANK 2
Temperature sensor
OPTIONAL
COMMON NEGATIVE (–)
Page 13
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
13
WARNING!
All electrical systems (AC and DC) must be disconnected from any power source during the entire installation!
CAUTION!
Too-thin cables and/or loose connections can cause dangerous overheating of the cables and/or terminals. Therefore, tighten all connections well, in order to limit transition resistance as far as possible. Use cables of the correct size.
CAUTION!
Short circuiting or reversing polarity may lead to serious damage to the batteries, the ChargeMaster Plus, the cabling and/or the terminal connections. Fuses between the batteries and the ChargeMaster Plus cannot prevent damage caused by reversed polarity. The damage as a result of reverse polarity is detectable by the service depart­ment and is not covered by the warranty.

3.8 Installation step-by-step

1
2
3
Open the connection compartment by loosening the two
screws.
4
Fix the enclosure to the wall by fastening two screws at the lower side
of the ChargeMaster Plus as well.
Page 14
14
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
5
Connect the AC wiring to the screw
terminals. Fasten the cable with the strain relief.
6
Integrate a fuse holder in the positive battery wire but do not place the fuse
yet! Fit crimp-on cable lugs to the DC
cables. Connect the DC cabling of
battery bank 1, positive to +, negative
to – .
Repeat steps for output 2 and 3.
7
Attach the battery temperature sensor
to the casing of battery bank 1. Plug the temperature sensor cable
into the “Temp sense” jack.
Option: Connect the ChargeMaster to
the CZone or MasterBus network.
8
Adding to a CZone network
1 Disconnect the backbone at the
closest backbone connection and add in a tee connector.
2 Reconnect the backbone
connection(s) with the new tee connector in place.
3 Connect the RJ45 CZone/MB drop
cable to the black coupler on the tee and then connect to the ChargeMaster Plus.
Adding to a MasterBus network
1 Disconnect a MasterBus cable or
Terminator from the closest
MasterBus device and connect it to the ChargeMaster Plus.
2 Connect the new MasterBus cable to
the other MasterBus device and then connect to the ChargeMaster Plus.
Ensure that the network is properly terminated.
Page 15
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
15

3.9 Commissioning after installation

1 Check the wiring; positive connected to
positive (red cables), negative connected to negative (black cables).
2 When all wiring is OK, place the DC fuse(s) to
connect the batteries to the ChargeMaster Plus.
WARNING!
When placing this fuse, a spark might occur, caused by the capacitors used in the ChargeMaster Plus. This is particularly dangerous in places with insufficient ventilation. Due to the gassing of the batteries, an explosion can occur. Avoid having flammable materials close by.
3 Switch on the AC power supply.
Note: when new, the ChargeMaster Plus will
not start charging batteries before activated with the ON/OFF button. See step 6.
4 Check the DIP switches.
See chapter DIP switch settings on page 16.
5 Check and adjust the settings of the
ChargeMaster Plus with MasterAdjust (MasterBus network) or with the CZone Configuration Tool (CZone network). See chapter SETTINGS on page 16.
6 When the settings meet the power system's
needs, press and hold the ON/OFF button for 3 seconds to switch the charger on and initiate the charging process.
9
If required, use a small screwdriver to change DIP switch settings. See
section 4.1.
10
Check all wiring; see also Figure 3
for wiring details. If all wiring is OK:
Place the DC fuses.
11
Close the connection compartment by fixing the screws.
12
Continue with section 3.9 for
commissioning of the ChargeMaster
Plus.
Page 16
16
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

4 SETTINGS

Adjustment of the settings of the ChargeMaster Plus can be made in two different ways:
By means of DIP switches.
From a laptop or notebook connected to the
ChargeMaster Plus via a USB Interface. Some settings can only be changed in this way.
CAUTION!
Invalid settings of the ChargeMaster Plus can cause serious damage to your batteries and/or the connected load! Only authorized personnel may adjust settings.
When required, the ChargeMaster Plus can be restored to factory settings (see section 4.2).

4.1 DIP switch settings

Use a small screwdriver to carefully set the required settings.
Figure 4: DIP switches (factory settings)
DIP switch 1 = CZone (0) or MasterBus (1) network.
DIP switch 2 = MasterBus powering off (0) or on (1)
DIP switches 3 to 10 are either used as CZone address or for MasterBus battery settings.
In a CZone network: DIP switch 1 must always be set to the OFF
position (0). DIP switch 2 must always be set to the OFF
position (0). DIP switches 3 to 10 must match the unique
address used in the CZone network; the dipswitch. See the CZone Configuration Tool Instructions manual for more information.
In a MasterBus network:
DIP switch 1 must always be set to the ON position (1).
DIP switch 2 is MasterBus Powering ON (1) or OFF (0).
DIP switches 3 to 5 are used for battery type selection:
DIP switch
3 4 5
MasterBus settings (Flooded)1
0 0 0
Flooded (fixed)
0 0 1
AGM (fixed)
0 1 0
Gel (fixed)
0 1 1
Lithium-ion (fixed)
1 0 0
Constant voltage (13,25/26,50V)2
1 1 1
1
If all DIP switches are in the OFF position (0 ), the
settings suit a Flooded battery but can be changed in MasterAdjust.
2
Constant voltage has no temperature compensation
See section 5.4 for more information on charge voltage settings and section 5.5 for DC OUT.

4.2 MasterBus configuration

MasterBus is a CAN based data network for communication between Mastervolt devices. When the ChargeMaster Plus is connected, open MasterAdjust on a Windows laptop or notebook connected to the MasterBus network via a MasterBus USB interface. MasterAdjust software is available as free to download software on the Mastervolt website: www.mastervolt.com. This tool runs on a Windows laptop or notebook.
Page 17
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
17

4.2.1 Monitoring

A remote panel, like the SmartRemote, Touch 5 (CZone) or EasyView 5 (MasterBus), can be used for reading battery information. See applicable user manuals for details. The following table lists the parameters as shown in MasterAdjust.
Parameter
Meaning
Value range
General
Device state
Shows charger state (On / Stand-by / Alarm / Off)
(read only)
Charger state
Actual state of charge process: Off/bulk/absorption/float/suspended
(read only)
'Toggle' button
Button to toggle the charger state. This button does not work when the ChargeMaster Plus is switched
off manually. In that case it can only be switched on with the ON/OFF button.
On / off
Input current
Option to set the maximum AC input current level to prevent a generator or shore fuse from overload. See section 4.2.6 for more information. Default 20.
12/35-3: 0-9A 12/50-3: 0-11A 24/20-3: 0-10A 24/30-3: 0-15A
AC present
Shows the presence of AC input
(read only)
Battery temp.
Temperature of the main battery bank (in °C)
(read only)
DC 1 OUT
Output 1
Output state (pre-float/on)
(read only)
Output 1 V
Voltage of charge output 1
(read only)
Output 1 A
Output current of charge output 1
(read only)
Shunt device
A connected MasterShunt can be chosen for feedback on the charged battery. Default not selected.
(read only) DC 2 OUT
Output 2
Output state (pre-float/on)
(read only)
Output 2 V
Voltage of charge output 2
(read only)
Output 2 A
Output current of charge output 2
(read only)
DC 3 OUT
Output 3
Output state (pre-float/on)
(read only)
Output 3 V
Voltage of charge output 3
(read only)
Output 3 A
Output current of charge output 3
(read only)
Parameters marked with a  are not available in CZone.

4.2.2 Alarms

The following table lists the available alarms in MasterAdjust.
Parameter
Meaning
Alarm status
Bat. temp. error
Battery temperature too high / too low
TS error
Temperature sensor error
AC error
AC input (mains) out of range
Dev. temp. high
ChargeMaster Plus temperature too high
DC 1 OUT
Shunt mismatch
Setting for nominal voltage (12/24V) at the MasterShunt or the nominal voltage of the MLI batteries differs from nominal voltage detected by the ChargeMaster Plus. Check battery voltage and settings of the MasterShunt or voltage of the MLI Ultra battery.
Page 18
18
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
Parameter
Meaning
Reverse polarity
DC + and DC – are connected in reverse (this will damage the charger)
DC 2 / 3 OUT
Reverse polarity
DC + and DC – are connected in reverse (this will damage the charger)

4.2.3 History

The history data shows the absolute maximum readings. The following parameters are only shown in MasterAdjust.
Parameter
Meaning
Charger
Days running
Total run time in charger mode
DC 1 / 2 / 3 OUT
Total Ah’s
Total charged Ah’s

4.2.4 Configuration settings

The configuration can be done in MasterAdjust, from a laptop or notebook connected to the ChargeMaster Plus via a Mastervolt USB Interface. See applicable user manuals for details. The following table lists the parameters as shown in MasterAdjust.
Notes: - DIP switch settings overrule MasterBus settings. If DIP switches are not in their default setting,
the corresponding MasterBus setting is grayed out.
- To be able to make changes to the configuration via MasterBus, DIP switch 1 must be in the
ON position.
Parameter
Meaning
Factory setting
Value range
Device
Language
Menu language of this device
English
EN, NL, DE, FR, ES, IT, NO, SV, FI, DA
Name
Name of this device. This name will be recognized by all devices connected to the network
CHG ChargeMaster
0-12 characters
Powersave mode
If Powersave mode is ON, the charger will switch itself off when no AC power is available. If Powersave mode is OFF, the charger stays ON even when no AC power is available.
On
On, Off
Charger
Method
Charge method
3-Step+
3-Step+, constant voltage
Maximum current
Maximum DC output current
Depending on model, 100%
Depending on model 20­100%
Battery type
The battery type settings are based on Mastervolt batteries. If connecting batteries of a different manufacturer, make sure the manufacturer's recom­mendations are met. Should this not be the case, then "User defined" must be selected to change the settings.
Flooded
User defined, AGM, Gel, Flooded, Lithium-ion (MLI)
Temp. compensate
Temperature depended charge voltage compensation
-0,030V/°C /
-0,060V/°C
-1,000/+1,000V/°C
Page 19
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
19
Parameter
Meaning
Factory setting
Value range
Bulk
Voltage
Bulk voltage (@ 25°C); see section 5.4
14.40/28.80V
8-16/16-32V
Minimum time
Minimum time of the Bulk phase since Start bulk timer
120sec
0-240sec
Start time at
Battery voltage trigger point to start the bulk timer
13.25/26.50V
(read only)
Maximum time
Maximum time of the Bulk phase since Start bulk timer
480 min
0-1440min
Absorption
Voltage
Absorption voltage (@ 25°C); see section 5.4
14.25/28.50V
8-16/16-32V
Maximum time
Maximum absorption timer
240min
0-1440min
Return Amps
Return amps. If the charge current drops below this level, the charger switches from the Absorption to the Float stage (% of I
max
)
6%
0-50%
Minimum time
Minimum absorption timer
15min
0-240min
Float
Voltage
Float voltage (@ 25°C); see section 5.4
13.25/26.50V
8-16/16-32V
Return to bulk V
Return to bulk voltage; If the battery voltage stays below this level for at least the Return to bulk delay time, the charger will start the Bulk stage
12.80/25.60V
8-16/16-32V Return to
bulk sec
Return to bulk delay time, see Return to bulk voltage
30sec
0-240sec
DC 1 OUT
Name
Name of this output
Output 1
0-16 chars
Shunt device
Selection of the MasterShunt to which output 1 of the ChargeMaster Plus is connected
Not selected
Not selected, MSH + Product Name
DC 2 / 3 OUT
Name
Name of this output
Output 2 / 3
0-16 chars
Installer menu
DIP Switch
DIP switch settings
1100000000
0 / 1
Factory settings button
Button to reset the ChargeMaster Plus to default settings (requires installer rights)
Not applicable
Not applicable
Parameters marked with a  are not available in CZone.

4.2.5 Events – System automation

A CZone/MasterBus device can be programmed to initiate an action at another connected device. This is very helpful in automation of your system but is not required.
In MasterBus this is done by means of event-based commands. In the Events tab you can program the ChargeMaster Plus to act as an event source. Events which occur during the operation of the
Page 20
20
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
ChargeMaster Plus will then trigger actions from other products. The following tables list the parameters as shown in MasterAdjust.
Field
Meaning
Value
Event x source
Select an event that triggers an action, for example Battery pre low.
See Event source list
Event x target
Select the device that should take action, for example the generator
Selectable targets are system dependent
Event x command
Select the parameter that must be changed on the target device, for example Activate.
See command list of the selected device
Event x data
Data, for example On, is linked to the command.
Off, On, Copy, Copy Invert, Toggle
Table 1: MasterBus event parameters
The ChargeMaster Plus can be configured as an event source. An event source can be used to initiate an event command and an event action by another device.
Event source
Meaning
Charger state
State of the ChargeMaster Plus serves as an event source
Bulk
Bulk state of charge serves as an event source
Abs
Absorption state of charge serves as an event source
Float
Float state of charge serves as an event source
Failure
Any fault condition of the ChargeMaster Plus serves as an event source
Table 2: ChargeMaster Plus MasterBus Event sources
When the ChargeMaster Plus is configured as an event target by another device, this device can initiate an event command and an event action to be performed by the ChargeMaster Plus.
Event command
Meaning
On
Command to switch on the ChargeMaster Plus
Bulk
Command to start the Bulk state of charge
Abs
Command to start the Absorption state of charge
Float
Command to start the Float state of charge
Suspend charging
When using an MLI Ultra Li-ion battery, this event is obligatory. Refer to the MLI Ultra manual.
Table 3: ChargeMaster Plus MasterBus Event commands

4.2.6 Current control

If the available power at the AC input is limited. The ChargeMaster can be configured to reduce input current. The Current Control level should be set equal to or lower than the value of the external circuit breaker, which protects the incoming AC power. For example, when the external AC power is limited by a 6A fuse, the Current Control level should be set to 6A. The AC input current of the ChargeMaster Plus will be reduced to 6A.
How to set the AC input current in a MasterBus network
1. Open MasterAdjust.
2. Select the ChargeMaster Plus.
3. Go to the Monitoring tab.
4. In the Input Current field, enter the required value.
Page 21
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
21

4.3 MasterShunt

In a MasterBus network, a MasterShunt can be coupled with output 1 (DC 1 OUT) of the ChargeMaster Plus. The actual measurement data of the MasterShunt will be used to charge the batteries. Refer to the manual of the MasterShunt for information on how to configure your system.

4.4 Lithium-ion Battery MLI Ultra

The ChargeMaster Plus can be combined with a Li-ion battery MLI Ultra. Refer to the manual of the Li-ion battery MLI Ultra for information on how to configure your system.
WARNING!
Before using the Li-ion battery, it must be properly installed and commissioned!

4.5 CZone configuration

The CZone® network is an NMEA 2000-compliant CAN-based system. When the ChargeMaster Plus is connected, open the CZone Configuration Tool on a Windows laptop or notebook connected to the CZone network. Either do the configuration while connected to the network or use a prepared configuration file (.zcf). Ensure that a DIP Switch is assigned.
Adding the ChargeMaster Plus to a CZone system configuration Precondition: This section assumes that a CZone system is already configured and the CZone
Configuration Tool is open. In the CZone Configuration Tool, from the Modules tab, press the Add button. From the Module Type drop-down list select Chargers. From the Charge Type drop-down list select the required model and continue with the following steps.
1. Enter an understandable Module Name.
2. Each device on a CZone network has a unique CZone address; the Dipswitch. This number must
match the physical DIP switch settings. When connected to the system: either select one from the drop-down list or edit graphically.
3. Select the Battery Type.
4. Enter the DC Current Limit.
5. Option: press the Advanced Settings button to configure advanced options.
6. Select the required Charge Method from the drop-down list.
7. Enter an understandable Name for DC 1 OUT, DC 2 OUT and DC 3 IN/OUT.
8. From the DC 3 Charge Method drop-down list, select the required charge method for DC 3 OUT.
See section 5.5. Depending on the selected charge method, additional settings will be offered, hidden or grayed out.
9. NMEA2000 Instances are used to differentiate between multiple monitoring sources.
10. Press OK to return to the Module Modification window and press the Alarm/Switch Settings
button.
11. Select the required Alarm Severities.
12. Press OK.
Optionally configure digital switching by adding Circuit Controls in the Circuits tab (e.g. a battery low switch can be used to start a generator). Write the configuration to the network to use the new configuration.
For more information, please refer to the CZone® Configuration Tool Instruction manual. Also see section 4.2 for a description of the same settings in MasterAdjust.
Page 22
22
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

5 OPERATING INSTRUCTIONS

5.1 Introduction

The Mastervolt ChargeMaster Plus is a fully automatic battery charger. This means that under normal circumstances it can be left switched on with AC power and batteries connected. The ChargeMaster Plus is suitable for charging of Li-ion and lead-acid batteries, which may include maintenance-free, low maintenance, AGM, gel or deep-cycle batteries. It operates on both 240V and 120V.
WARNING!
The MLI charging voltages on this charger fit the Mastervolt Li-ion (MLI) batteries but do not necessa­rily fit other Li-ion batteries! Always follow the instructions provided by the battery manufacturer!

5.2 Switching on / off

The ChargeMaster Plus is activated by keeping the ON/OFF button pressed for approximately 3 seconds. The MODE LED will illuminate green. If necessary and if AC power is available, the ChargeMaster Plus will start to charge the batteries.
Note: Once switched on, the ChargeMaster Plus
automatically resumes operation after it was disconnected from an AC source temporarily.
By holding the ON/OFF button pressed again for approx. 3 seconds, the ChargeMaster Plus will switch off: the ChargeMaster Plus stops and the MODE LED illuminates red. When the ChargeMaster Plus was switched off, it can only be activated by pressing the ON/OFF button again.
WARNING!
Switching the ChargeMaster Plus off or “stand-by” does not cut off the connection to the batteries or the AC source. This means that voltages are still present inside the apparatus.

5.3 Status display

The status display at the front side of the ChargeMaster Plus enables you to control the charger and monitor the charging process.
Note: The ChargeMaster Plus can also be
monitored from a remote panel like the Touch 5 (in a CZone network) or the EasyView 5 (in a MasterBus network). See section 4.2 for details.
Figure 5: ChargeMaster Plus status display
ON/OFF button
Hold MODE pressed for 3 seconds to
switch the charger on or off
NETWORK
Blinks when there is
network communication
MODE
Indicates ChargeMaster
Plus status
Battery 1, 2 & 3
Battery charge status
Page 23
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
23
The status display has a 3-level menu. Menu navigation is done by shortly pressing the ON/OFF button. After each press the next menu level is shown. The MODE LED color indicates the level that is being shown.
Menu
MODE LED color
Meaning
Level 1
Green
Status menu
Level 2
Orange
Output power menu
Level 3
Red
Error menu
Status
LED
State
Meaning
MODE
Solid green
ChargeMaster Plus on
Solid red
ChargeMaster Plus stand-by
Blink fast red
Error, navigate to error menu
Battery 1
Blinking fast green
Battery in bulk stage
Blinking slow green
Battery absorption stage
Solid green
Battery in float stage
Battery 2
Blinking fast green
Battery in bulk stage
Blinking slow green
Battery absorption stage
Solid green
Battery in float stage
Battery 3
Blinking fast green
Battery in bulk stage
Blinking slow green
Battery absorption stage
Solid green
Battery in float stage
Network
Blinking green
Network communication
Output power
LED
State
Meaning
MODE
Solid orange
Output power menu
Battery 1
Solid orange
Total output power 0­25%
Battery 2
Solid orange
Total output power 26­50%
Battery 3
Solid orange
Total output power 51­75%
Network
Solid orange
Total output power 76­100%
Error
LED
State
Meaning
What to do
MODE
Blink fast red
Error menu
Battery 1
Blink fast red
Reverse polarity
Check battery connection
Battery 2
Blink fast red
AC error
Check AC voltage/ frequency
Battery 3
Blink fast red
DC error
Check battery voltage
Network
Blink fast red
Tempera­ture sense error
Check temperature sensor

5.4 The 3-step+ charge process

Battery charging is accomplished in three automatic stages: BULK, ABSORPTION and FLOAT.
The first step is the BULK phase, in which the output current of the charger is 100%, and the greater part of the capacity of the battery is rapidly charged. The current charges the batteries and gradually the voltage rises to the
BULK voltage 14.25V respectively 28.5V at
25°C/77°F. The duration of this phase depends on the ratio
of battery to charger capacity, and the battery state of charge.
Figure 6: charge process
The BULK phase is followed by the ABSORPTION phase. Absorption charging starts when the voltage on the batteries has reached the BULK voltage and ends when the battery is completely full. Battery voltage remains constant at
14.25V/28.5V at 25°C/77°F throughout this stage, and the charge current depends on the degree to which the battery was initially
Page 24
24
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
discharged, the battery type, the ambient temperature, etc. With a flooded battery this stage lasts approx. 4h, with gel and AGM around 3h. Once the battery is 100% full, the ChargeMaster Plus automatically switches over to the FLOAT phase. In FLOAT, the ChargeMaster Plus switches to a stabilized 13.25V/26.5V (Flooded), 13.8V/27.6V (Gel/AGM) or 13.5V/27V (MLI) at 25°C/77°F.
Connected DC loads are powered directly by the charger. If the load exceeds the charger capacity, the required additional power comes from the battery, which will be progressively discharged until the charger automatically switches back to the bulk phase. Once consumption decreases, the charger goes back to normal operation of the 3-step charge system.
As the ChargeMaster Plus is equipped with a 3­step+ charge system, the batteries can also remain connected to the ChargeMaster Plus during winter. One hour every 14 days the charger automatically switches to absorption to keep the battery running properly and prolong its life span. The three-step plus charge system is also safe for all the connected equipment. See also Figure 9 on page 31.

5.4.1 Charge voltages

Bulk
Absorption
Float
AGM or GEL
14.25 /
28.5
14.25 /
28.5
13.80 /
27.6
Flooded
14.25 /
28.5
14.25 /
28.5
13.25 /
26.5
Lithium-ion
14.00 /
28.0
14.00 /
28.0
13.50 /
27.0

5.4.2 Pre-float

The ChargeMaster Plus can automatically switch each individual output from absorption to pre­float stage. Pre-float ensures batteries that are
nearly full don’t receive the higher charge
voltage needed in the absorption stage. This prevents over-charging, extending the lifespan of the batteries.

5.4.3 Temperature compensated charging

By installing the battery temperature sensor, the charge voltages are automatically adapted for deviating temperatures.
Charge voltage (V)
Battery temperature (°C)
Figure 7: Temperature compensated charging
When the battery temperature is low, the charge voltage increases. On the other hand, when the battery temperature is high, the charge voltage is decreased. Overcharge and gassing are prevented this way. This will extend the life of your batteries.

5.4.4 Flat battery support

The ChargeMaster Plus automatically detects a flat battery and will initiate the flat battery charge curve described in the following table.
UBat
Voltage
Output power
12V 24V
0.00V – 2.50V
0.00V – 5.00V
15%-30% of I
max
12V 24V
2.50V – 8.00V
5.00V – 16.00V
25% of I
max
12V 24V
8.00V – 10.00V
16.00V – 20.00V
linear from 25% ­100% of I
max
12V 24V
10.00V – 14.25V
20.00V – 28.50V
100% of I
max
12V 24V
>14.25 >28.50
Limited by P
max

5.5 DC OUT

The ChargeMaster Plus is equipped with three full outputs; DC 1 OUT, DC 2 OUT and DC 3 OUT. The total output current is divided over these three outputs. All batteries are charged with the same settings. See section 3.6 for connections.

5.6 Maintenance

No specific maintenance to the ChargeMaster Plus is required. Examine your electrical installation on a regular basis, at least once a year. Defects such as loose connections, dam­aged wiring etc. must be corrected immediately. If necessary, use a soft clean cloth to clean enclosure of the ChargeMaster Plus. Do not use any liquids or corrosive substances, such as solvents, alcohol, petrol or abrasive components.
Page 25
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
25

5.7 Storage

If it is necessary to put the ChargeMaster Plus out of operation, execute the following steps:
1 Turn AC power off. 2 Switch off the ChargeMaster Plus (see
section 5.2).
3 Remove the DC fuse(s) and disconnect the
batteries.
4 Switch the RCD/Breaker of the AC input to
the OFF position and, if required, disconnect the AC mains.
5 Open the connection compartment of the
ChargeMaster Plus.
6 Check with a suitable voltage meter whether
the inputs and the outputs of the ChargeMaster Plus are voltage free.
7 Disconnect all the wiring.
Now the ChargeMaster Plus can be demounted in a safe way. When not installed, store the ChargeMaster Plus in a dry and dust free environment. To return to normal operation, after re-installation, switch on the AC.
Page 26
26
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

6 TROUBLE SHOOTING

The ChargeMaster Plus is protected against overload, short circuit, overheating and under and over voltage. If a fault condition occurs, the LEDs indicate an error code. See section Status display for an explanation.
CAUTION!
The ChargeMaster Plus is not protected against serious over voltage (>275VAC) on the AC input.
If you cannot solve a problem using the fault-finding table, contact your supplier or Mastervolt. Make sure you have the part and serial number at hand.
Malfunction
Possible cause
What to do
No output voltage and/or current
No AC input
Check AC wiring, check remote control panel
AC input voltage too low (< 75VAC)
Check input voltage, check generator
AC input frequency out of range
Check input voltage, check generator
Output voltage too low, charger supplies maximum current
Load connected to the batteries is larger than charger can supply
Reduce load taken from the batteries
Batteries not 100% charged
Measure battery voltage. After some time this will be higher
Wrong setting of the charge voltage
Check settings (see chapter 4)
Charge current too low
Batteries almost fully charged
Nothing, this is normal when the battery is almost fully charged
High ambient temperature
Nothing; if ambient temperature is more than the setting limit, the charge current is automatically reduced
Low AC input voltage. At lower AC input voltages, the charge current is reduced
Check AC input voltage
Batteries not fully charged
Charge current too low
See “Charge current too low” in this
table
Current to load is too high
Reduce load taken from the batteries
Charge time too short
Use a battery charger with higher capacity
Battery temperature too low
Use the battery temperature sensor
Defective or old battery
Check battery and replace if necessary
Wrong setting of the charge voltage
Check settings (see chapter 4)
Batteries are discharged too fast
Battery capacity reduced due to wastage or sulphation, stagnation
Charge and recharge a few times, this might help.
Check battery and replace if necessary
Batteries are too warm, gassing
Defective battery (short circuit in cell)
Check battery and replace if necessary Battery temperature too high
Use the battery temperature sensor
Charge voltage too high
Check settings (see chapter 4)
Page 27
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
27
Malfunction
Possible cause
What to do
Remote panel display shows no ChargeMaster Plus
Display is switched off
Switch on display, refer to display manual
Error in the wiring
Check the network cables
No terminating device placed at the ends of the network
A network needs a terminating device on both ends of the network, check if available
Network is configured as a ring network
Ring networks are not allowed. Check the connections of the network.
ChargeMaster Plus is not configured in CZone configuration file
Open CZone Configuration Tool and check.
ChargeMaster Plus Dipswitch not correct
Open CZone Configuration Tool and check with Force Dipswitch for Address.
Slow or no MasterBus communication.
Error in the MasterBus wiring
Check the network cables
No MasterBus Terminator placed at the ends of the network
MasterBus needs a terminating device on both ends of the network. Check if connected
MasterBus network is configured as a ring network or there are T­connections
Ring networks and T-connections are not allowed. Check the connections of the network
Page 28
28
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

7 TECHNICAL DATA

7.1 Specifications 12V models

Model
12/35-3
12/50-3
Product code
44310355
44310505
Nominal input voltage
120/240V
120/240V
Nominal input frequency
50/60Hz
50/60Hz
Full load consumption
600VA
850VA
Max. AC input current (@ 230VAC)
2.5A
3.5A
Max. AC input current (@ 120VAC)**
5.0A
7.1A
Nominal output voltage
14.25V
14.25V
Total charge current*
35A at 14.25V
50A at 14.25V
Number of battery outlets
3 3 Charge characteristic*
IUoUo, automatic, 3-step+
Charge voltage Bulk*
14.4V
14.4V
Charge voltage Absorption*
14.25V
14.25V
Charge voltage Float*
13.25V
13.25V
Max absorption and max bulk timer*
8 hours (start max. bulk timer at 13.25V)
Minimum absorption time*
15 min.
15 min.
Maximum ripple voltage on DC
180mV pp
180mV pp
Battery type settings*
Flooded (default), GEL, AGM, Lithium-ion (MLI), Constant voltage (13,25 V)
Dimensions (mm)
291×210×105
291×210×105
Dimensions (inch)
11.5×8.3×4.1
11.5×8.3×4.1
Weight
2,5 kg (5.5 lbs)
2,5 kg (5.5 lbs)
Recommended battery capacity
70-300Ah
100-400Ah
Power factor regulations
0,98
0,98
Temperature compensation
Battery temperature sensor and cable included.
Voltage compensation
Yes, by means of automatic compensation or MasterShunt
DC consumption
<2mA (MasterBus off)
<2mA (MasterBus off)
Temperature range
–25°C (–13°F) to 80°C (176°F) Derating 1%/°C (0.5%/°F) from 40°C (104°F) to 60°C (140°F) Derating 8%/°C (4.4%/°F) from 60°C (140°F) to 70°C (158°F) Communication available, 0% output power from 70°C (158°F) to 80°C (176°F)
Cooling
Vario fan and natural cooling to ensure optimized cooling
Sound level
<45dBA / 1m
Protection degree
IP 23
IP 23
CZone connectivity
Yes
Yes
MasterBus connectivity
Yes
Yes
Powering capabilities for MasterBus
Yes
Yes
Yes, when the charger is switched on and AC is available, it can power up to three non-powering devices.
Ignition protected
Yes, conforming to SAE J1171/ISO 8846
* Adjustable, see chapter 4 for settings. ** The input RCD/Fuse rating selection must be greater than 120% of the max input current (@ 120VAC)
or in accordance with the requirements of national electrical regulations.
Specifications are subject to change without prior notice.
Page 29
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
29

7.2 Specifications 24V models

Model
24/20-3
24/30-3
Product code
44320205
44320305
Nominal input voltage
120/240V
120/240V
Nominal input frequency
50/60Hz
50/60Hz
Full load consumption
700VA
1000VA
Max. AC input current (@ 230VAC)
2.8A
4.2A
Max. AC input current (@ 120VAC)**
5.6A
8.6A
Nominal output voltage
28.5V
28.5V
Total charge current*
20A at 28.5V
30A at 28.5V
Number of battery outlets
3
3
Charge characteristic*
IUoUo, automatic, 3-step+
Charge voltage Bulk*
28.8V
28.8V
Charge voltage Absorption*
28.5V
28.5V
Charge voltage Float*
26.5V
26.5V
Max absorption and max. bulk timer*
8 hours (start max. bulk timer at 26.5V) Minimum absorption time*
15 min.
15 min.
Maximum ripple voltage on DC
300mV pp
300mV pp
Battery type settings*
Flooded (default), GEL, AGM, Lithium-ion (MLI), Constant voltage (13,25 V)
Dimensions (mm)
291×210×105
291×210×105
Dimensions (inch)
11.5×8.3×4.1
11.5×8.3×4.1
Weight
2,5 kg (5.5 lbs)
2,5 kg (5.5 lbs)
Recommended battery capacity
160-400Ah
200-500Ah
Power factor regulations
0,98
0,98
Temperature compensation
Battery temperature sensor and cable included.
Voltage compensation
Yes, by means of automatic compensation or MasterShunt
DC consumption
<2mA (MasterBus off)
<2mA (MasterBus off)
Temperature range
–25°C (–13°F) to 80°C (176°F) Derating 1%/°C (0,5%/°F) from 40°C (104°F) to 60°C (140°F) Derating 8%/°C (4,4%/°F) from 60°C (140°F) to 70°C (158°F) Communication available, 0% output power from 70°C (158°F) to 80°C (176°F)
Cooling
Vario fan and natural cooling to ensure optimized cooling
Sound level
<45dBA / 1m
Protection degree
IP 23
IP 23
CZone connectivity
Yes
Yes
MasterBus connectivity
Yes
Yes
Powering capabilities for MasterBus
Yes
Yes
When the charger is switched on and AC is available, it can power up to three non-powering devices.
Ignition protected
Yes, conforming to SAE J1171/ISO 8846
* Adjustable, see chapter 4 for settings ** The input RCD/Fuse rating selection must be greater than 120% of the max input current (@ 120VAC)
or in accordance with the requirements of national electrical regulations.
Specifications are subject to change without prior notice.
Page 30
30
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual

7.3 Dimensions

Dimensions in mm [inches] of the ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3.

7.4 Characteristics

Output power (%)
AC voltage (V)
Figure 8: Output power versus input voltage
Page 31
ChargeMaster Plus 12/35-3, 12/50-3, 24/20-3, 24/30-3 – User and Installation Manual
31
Figure 9: 3-step+ charging characteristics of flooded batteries
Page 32
Europe, Middle East & Africa
Customer Service
T: +31 (0) 20 34 22 100 E: info@mastervolt.com
Technical Support
T: +31 (0) 20 34 22 100 E: ts@mastervolt.com
Location & Shipping
Mastervolt Snijdersbergweg 93 1105 AN Amsterdam The Netherlands
Americas & Caribbean
Customer Service
T: +1 800 307 6702, Option 1 E: orderentry@marinco.com
Technical Support
T: +1 800 307 6702, Option 2 E: tsusa@mastervolt.com
Location & Shipping
Power Products, LLC N85 W12545 Westbrook Crossing Menomonee Falls, Wisconsin 53051 United States
Asia Pacific
Customer Service
T: +64 9 415 7261 Option 1 E: enquiries@bepmarine.com
Technical Support
T: +64 9 415 7261 Option 3 E: technical@bepmarine.com
Location & Shipping
BEP Marine 42 Apollo Drive Rosedale, Auckland 0632 New Zealand
Copyright © 2020 Mastervolt. All rights reserved.