Mastervolt MasterView Easy MkII User Manual

Page 1
USERS MANUAL / GEBRUIKERSHANDLEIDING
BETRIEBSANLEITUNG / MANUEL D’UTILISATION
MANUAL DE UTILIZACION / INSTRUZIONI PER L’USO
Monitoring and control panel for the MasterBus network
MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com
v 1.5 September 2010
ENGLISH: PAGE 1
NEDERLANDS: PAGINA 25 DEUTSCH: SEITE 49 FRANÇAIS: PAGINA 73 CASTELLANO: PÁGINA 97 ITALIANO: PAGINA 121
Page 2
CONTENTS
2 September 2010 / MasterView Easy MkII / EN
CONTENTS: v 1.5 September 2010
1
GENERAL INFORMATION............................................................................................................................. 4
1.1 Product description............................................................................................................................. 4
1.2 Use of this manual.............................................................................................................................. 4
1.3 Guarantee specifications .................................................................................................................... 4
1.4 Liability................................................................................................................................................ 4
1.5 Identification label............................................................................................................................... 4
2 SAFETY........................................................................................................................................................... 5
2.1 Use of symbols ................................................................................................................................... 5
2.2 Use for intended purpose ................................................................................................................... 5
2.3 Safety regulations and measures ....................................................................................................... 5
3 MASTERBUS.................................................................................................................................................. 6
3.1 What is MasterBus?............................................................................................................................ 6
3.2 Event based commands ..................................................................................................................... 6
3.3 How to set up a MasterBus network................................................................................................... 7
4 INSTALLATION .............................................................................................................................................. 8
4.1 Flush mounting and panel mounting .................................................................................................. 8
4.2 Things you need ................................................................................................................................. 8
4.3 Installation step by step ...................................................................................................................... 8
5 OPERATION ................................................................................................................................................... 9
5.1 General ............................................................................................................................................... 9
5.2 Button control...................................................................................................................................... 9
5.2.1 Switching on and off............................................................................................................9
5.2.2 Locking ................................................................................................................................ 9
5.3 Navigation........................................................................................................................................... 9
5.4 Control .............................................................................................................................................. 10
5.5 Maintenance ..................................................................................................................................... 11
6 MONITORING AND CONFIGURATION....................................................................................................... 12
6.1 Monitoring ......................................................................................................................................... 12
6.2 Masterview Easy configuration......................................................................................................... 13
6.2.1 Changing of characters ..................................................................................................... 13
6.3 Masterview Easy Events................................................................................................................... 14
6.4 Event data......................................................................................................................................... 14
6.5 Follow the toggle leader ................................................................................................................... 14
6.6 Favourite + control page................................................................................................................... 14
6.6.1 Name Favourites page...................................................................................................... 15
6.6.2 Areas ................................................................................................................................. 15
6.6.3 Devices.............................................................................................................................. 15
6.6.4 Groups............................................................................................................................... 15
6.6.5 Items.................................................................................................................................. 15
6.6.6 Add .................................................................................................................................... 15
6.6.7 Example ............................................................................................................................ 15
6.6.8 Showing the Favourites page............................................................................................ 16
6.7 Configuring other devices................................................................................................................. 16
6.8 Digital switches ................................................................................................................................. 16
6.8 Digital switches ................................................................................................................................. 16
6.9 Tanklevel Interface ........................................................................................................................... 17
7 ADDITIONAL INFORMATION...................................................................................................................... 18
Page 3
CONTENTS
EN / MasterView Easy MkII / September 2010 3
7.1 MasterAdjust software ...................................................................................................................... 18
7.2 Ordering information......................................................................................................................... 18
8 TROUBLE SHOOTING ................................................................................................................................. 19
9 SPECIFICATIONS ........................................................................................................................................ 21
9.1 Technical specifications.................................................................................................................... 21
9.2 Dimensions ....................................................................................................................................... 22
10 EC DECLARATION OF CONFORMITY ....................................................................................................... 23
Page 4
GENERAL INFORMATION
4 September 2010 / MasterView Easy MkII / EN
1 GENERAL INFORMATION
1.1 PRODUCT DESCRIPTION
The Mastervolt MasterView Easy MkII is a panel to monitor, configure and operate all connected devices in the MasterBus network.
1.2 USE OF THIS MANUAL
This manual serves as a guideline for the safe and effective operation, maintenance and possible correction of minor malfunctions of the MasterView Easy MkII, part number 77010305, called MasterView Easy from this section on. Keep this manual at a secure place! The English version has 24 pages.
1.3 GUARANTEE SPECIFICATIONS
Mastervolt guarantees that this product was built according to the legally applicable standards and stipulations. If you fail to act in accordance with the regulations, instructions and stipulations in this user’s manual, damage can occur and/or the product will not fulfil the specifications. This may mean that the guarantee will become null and void.
1.4 LIABILITY
Mastervolt can accept no liability for:
consequential damage due to use of the MasterView Easy;
possible errors in the manuals and the results thereof.
use that is inconsistent with the purpose of the product
1.5 IDENTIFICATION LABEL
The identification label (see figure 1) is located at the back side of the MasterView Easy. Important technical information required for service, maintenance & secondary delivery of parts can be derived from the identification label.
Never remove the identification label!
Figure 1:
Identification
label
Page 5
SAFETY GUIDELINES AND MEASURES
EN / MasterView Easy MkII / September 2010 5
2 SAFETY
2.1 USE OF SYMBOLS
Safety instructions and warnings are marked in this manual by the following pictogram:
CAREFUL!
Special data, restrictions and rules with regard to preventing damage.
A procedure, circumstance, etc which deserves extra attention.
2.2 USE FOR INTENDED PURPOSE
1 The MasterView Easy is constructed as per the
applicable safety-technical guidelines.
2 Use the MasterView Easy only:
in a technical correct condition;
observing the instructions in the users
manual.
connected to the MasterBus network
3 Use of the MasterView Easy other than
mentioned in point 2 is not considered to be consistent with the intended purpose. Mastervolt is not liable for any damage resulting from the above.
2.3 SAFETY REGULATIONS AND MEASURES
Do not work on an electrical system if it is still connected to a current source. Only allow changes in your electrical system to be carried out by qualified electricians.
Page 6
GENERAL INFORMATION
6 September 2010 / MasterView Easy MkII / EN
3 MASTERBUS
3.1 WHAT IS MASTERBUS?
All devices that are suitable for MasterBus are marked by the MasterBus symbol.
MasterBus is a fully decentralized data network for communication between the different Mastervolt system devices. The communication network is based on CAN-bus which has proven a reliable bus­system in automotive applications. MasterBus is used as power management system for all connected devices, such as the inverter, battery charger, generator and many more. This gives the possibility for communication between the connected devices, for instance to start the generator when the batteries are low.
MasterBus reduces complexity of electrical systems by using MasterBus cables. All system components are simply chained together. Therefore each device is equipped with two MasterBus data ports. When two or more devices are connected to each other through these data ports, they form a local data network, called the MasterBus. The results are a reduction of material costs as only a few electrical cables are needed and less installation time.
For central monitoring and control of the connected devices Mastervolt offers a wide range of panels which show full status information of your electrical system at a glance and a push of a button. Example is the full colour MasterView System panel. All monitoring panels can be used for monitoring,
control and configuration of all connected MasterBus equipment.
New devices can be added to the existing network in a very easy way by just extending the network. This gives the MasterBus network a high degree of flexibility for extended system configuration, not only today, but in the future as well! Mastervolt also offers several interfaces, making even non-MasterBus devices suitable to operate in the MasterBus network. For direct communication between the MasterBus network and a product which is not from Mastervolt, the Modbus interface is recommended.
CAUTION: Never connect a non­MasterBus device to the MasterBus network directly! This will void warranty of all MasterBus devices connected.
3.2 EVENT BASED COMMANDS
With MasterBus each device can be programmed to initiate an action at an other connected device. This is done by means of event based commands.
Example: if the shore power is almost in overload, a generator must be started. As the shore power is measured by the Mass
Systemswitch, this device is considered as the command source. The generator is the device that
should initiate an action (start the generator), and is therefore considered to be the target. This means that the Mass Systemswitch must be programmed as follows:
Event source: Shore pre overload Select from list of events sources
(see manual of the Mass Systemswitch)
Event target: Generator Select from the device list (devices connected to the
MasterBus)
Event command: Status Select event command from the list of event commands of
the target (see manual of the Generator)
Event data: On Select event action from the list of event commands of the
target (see manual of the Generator)
See chapter 6 for the MasterView easy list of event sources and list of event commands.
Page 7
MASTERBUS
EN / MasterView Easy MkII / September 2010 7
3.3 HOW TO SET UP A MASTERBUS NETWORK
Every device that is suitable for the MasterBus network is equipped with two data ports. When two or more devices are connected using these ports, together they form a local data network, called the MasterBus.
Keep the following rules in mind:
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Do not make T-connections in the network.
Do not make ring networks.
The electric power for the network comes from the connected devices. At least one device in the network should have powering capabilities (see specifications). One powering device can power up to three non­powering devices. As all powering devices are galvanically isolated, multiple powering devices are allowed.
OK
As with all high speed data networks, MasterBus needs a terminating device on both ends of the network .
Terminating
device
Terminating
device
OK
Connections between the devices are made by standard straight MasterBus cables. Mastervolt can supply these cables. These cables are also commonl
y
available at computer supply stores.
OK
Page 8
INSTALLATION
8 September 2010 / MasterView Easy MkII / EN
4 INSTALLATION
WARNING
During installation and commissioning of the Masterview Easy, the Safety Guidelines and Measures are applicable at all times. See chapter 2 of this manual.
4.1 FLUSH MOUNTING AND PANEL MOUNTING
The Masterview Easy can be flush mounted or panel mounted on a wall or board. For flush mounting the outer housing can be removed easily. The connections are at the back of the panel and space for the two MasterBus connectors is provided when for panel mounting is opted.
4.2 THINGS YOU NEED
Tools:
A drill for the mounting holes A saw to make a cut-out for flush mounting the
panel
A cross-head screw driver
Materials:
; The MasterView Easy panel (included) ; 4 screws for mounting (included) ; MasterBus connection cable (MasterBus cable)
(6 meter / 20ft included)
; MasterBus terminating devices (1 pc included)
4.3 INSTALLATION STEP BY STEP
Panel mounting the MasterView Easy Display
Remove the outer housing and remove the front.
Drill the holes using the dimensions inside the outer housing and fasten the outer housing (1).
Insert the MasterBus connection cables into the MasterBus data ports and click the panel into the outer housing (2).
Reattach the front (3), see figure 8.
2
Figure 8
1
2
3
Flush mounting the MasterView Display.
Remove the outer housing and remove the front from the panel.
Make a cut out in the mounting wall and drill the holes using the saw template in the box or using the dimensions on the panel.
Insert the MasterBus connection cables into the MasterBus data ports.
Mount the MasterView Easy onto the panel (1) and then reattach the front (2), see figure 7.
1
Figure 7
1
2
Page 9
OPERATION
EN / MasterView Easy MkII / September 2010 9
5 OPERATION
5.1 GENERAL
The Mastervolt MasterView Easy is a central monitoring and control panel for devices that are connected to the MasterBus network. It shows status information of your electrical system by means of a touch screen.
5.2 BUTTON CONTROL
5.2.1 Switching on and off
Press the button shortly to switch on the MasterView Easy panel. See figure 10. After a short time the first
screen is shown, for device selection. Pressing the button shortly again results in switching off the Easy panel.
5.2.2 Locking
Pressing the button for more than two seconds when the Easy panel is switched on, results in locking the panel, see figure 10. In this mode the panel will not react on pressing the screen. The “locked” key is shown in the left lower corner, see figure 10. Unlocking is accomplished by pressing the button for more than two seconds again.
NOTE: As every configuration of the MasterBus network is unique, this user’s manual can not give specific instructions for any particular device connected, except for the MasterView Easy itself. Refer to the user’s manual of the connected device for an overview of all available readouts and settings.
5.3 NAVIGATION
Monitoring and control of the MasterView Easy can be done by scrolling through the menus.
Figure 9 navigation buttons
Press the Up and Down arrow to scroll through a menu vertically (see figure 9, number 1)
Press the Up and Down arrow to increase resp. decrease a value or (see figure 9, number 1)
Press the closed arrow to show a group (see figure 9, number 2)
Press the Right or Left arrow to scroll through a menu horizontally, through the groups (see figure 9, number 3)
Press X to leave a menu or to cancel a setting (see figure 11). You will then return to the main menu.
1
2
3
Page 10
OPERATION
10 September 2010 / MasterView Easy MkII / EN
5.4 CONTROL
The MasterView Easy is a monitoring and control panel for the MasterBus network. The display guides you through the different menus, starting with the selection of device you wish to monitor. See the example on these two pages.
NOTE: The screens shown may differ
from the screens on your own MasterView Easy.
Figure 10: Operation of the MasterView Easy, opening screens
M
ASTERVOLT
M
ASTERVOLT
M
ASTERVOLT
M
ASTERVOLT
M
ASTERVOLT
M
ASTERVOLT
MasterShunt
MV Easy
Mastership
Off
On
Locked
=
=
State of
Charge
100%
Time
remaining
12:34:56
Cap.
consumed
0Ah
Go to Alarm
Go to
Configuration
MSH MasterShunt
MSH MasterShunt
MSH MasterShunt
100%
Distribution
OK
On
MasterShunt
MV Easy
100%
Distribution
OK
On
System level Product level
Exit Product level, Go to system level
Scroll through Product menus
Go to Product Configuration
Go to Product Alarms
Unlock
Press shortly: 0-2 sec.
Press long: longer than 2 sec.
Page 11
OPERATION
EN / MasterView Easy MkII / September 2010 11
Figure 11: Operation of the MasterView Easy, example Configuration
5.5 MAINTENANCE
If you need to clean the touch screen without controlling function, use Keyboard Lock. Press button long to lock keyboard, see figure 10.
Clean touch screen with a soft cloth. Do NOT use acids or scourers! Press button long again to unlock keyboard.
MasterShunt
Configuration
MasterShunt
Configuration
Battery
=
Device name
MasterShunt
}
Press 0-2 seconds
Exit Configuration
Enter Chapter
Scroll through chapters
Exit Chapter
Adjust settings
Scroll within chapter
Page 12
MONITORING AND CONFIGURATION
12 September 2010 / MasterView Easy MkII / EN
6 MONITORING AND CONFIGURATION
6.1 MONITORING
The MasterView Easy start screen shows the Device List, see also figure 10. By selecting the Easy display itself, you will enter the MasterView Easy
monitoring menu, see the table below. The settings are stored in the internal memory of the selected device. As a result of this, switching off the MasterView Easy will not influence the settings.
Variable Meaning Default Range
Language Displayed language of the MasterView Easy.
This display enables changing the language of all connected MasterBus devices in one go.
English See
specifications
Backlight Illumination of the display’s backlight. Auto Auto/On/Off Switch X Configurable switch on the MasterView Easy - X = 1 to 6 Go to configuration Press Enter to continue with the configuration menu.
Page 13
MONITORING AND CONFIGURATION
EN / MasterView Easy MkII / September 2010 13
6.2 MASTERVIEW EASY CONFIGURATION
To change settings of the MasterView Easy display, press Go To Configuration. The MasterView Easy configuration menu is used for read out and adjustment of settings like backlight illumination, displayed language and number of devices.
The MasterView Easy Configuration Lock disables configuration of all connected
devices. After selection of Configuration Enabled the Configuration Lock symbol disappears in all configuration groups. The first configuration group (at Easy panel: General) always remains enabled.
Variable Meaning Default Adjustable. range
General Name yacht Name of the boat, the panel is installed on.
See also section 6.2.1.
Yacht name Maximum 16 characters
Device name Name of this device. This name will be
recognized by all connected devices.
DIS MV Easy
DIS+Maximum 12 characters
Switch X Switches to use for event configuration.
Renaming the switches after their application is recommended. X ranges 1 – 6.
Switch X Maximum 16 characters
Devices in list Devices to show in the device list. At
Selection three selection boxes appear to choose a MasterBus device connected. Excluded means, you can select all devices except maximum three devices.
Selection, All, Excluded
Buzzer Switching of the buzzer.
The buzzer can also be target in the MasterBus events, if activated it sounds for maximum 1 minute. See also section 6.3. This means the buzzer can sound even if you switched it off in the configuration.
On On, Off
Auto Lock after Time after which to lock the panel. Off Off, 2, 5, 10 minutes Backlight Choose the backlight colour. In alarm the
backlight turns red, if not red already.
White White, Red
Power save Backlight time Time the display backlight stays illuminated
since the last button was touched.
2 minutes always off,2 minutes,5
minutes,10minutes,always on
Auto off Time after which the MasterView Easy will
be switched off since the last button touch.
1 day 1 day, 2 days,
always on Backlight Percentage of illuminance 50% 0-100%, in 10% steps Favourites page Name fav. page Name of your Favourites page. - Maximum 16 characters Favourites page Selection of areas to show. Analogue
means, a bar is shown instead of a value.
no No, analogue, 1,2,3,4,6 areas,
1-3 tanklevels Connect to Fav Connect to Area to connect the next item to Area 1 Area 1,2,3,4,5,6 Device Device to add the monitoring item from Select… System dependent Group no. Group number in monitoring page selected 1 1-65535 Item no. Item number in monitoring page selected 1 1-65535 Add Add the item to the Favourites page
In Connected favour., a list of the added monitoring items for the chosen areas is shown. This list is read only in user level.
6.2.1 Changing of characters
Changing of characters, for instance the yacht name, is accelerated by keeping the up/down arrow
pressed. The characters change then in second gear.
Page 14
MONITORING AND CONFIGURATION
14 September 2010 / MasterView Easy MkII / EN
6.3 MASTERVIEW EASY EVENTS
Shown are the events to configure on the MasterView Easy. For instance a light can be switched Off when the
Easy is switched On, the event source is then State These event sources can be used to initiate an event command and an event action by an other device that is connected to the MasterBus.
Variable Meaning Default Adjustable. range Event X Source
Choose an event to serve as Event X Disabled means no event has been configured. The MasterView Easy features 6 Switches to serve as event sources. These switches can be named after their application.
Disabled Disabled,
Switch 1 - 6, Backlight change,
State Event X Target
Selection of the MasterBus connected device to take action due to Event X
Choose… System dependent
Event X Command
Event-based command Action to be taken by the Event X target.
Choose… System dependent
Event X Data
Event 1 data controls the Event X command, see section 6.4 for explanation.
Off Off, On, Copy, Copy
Invert, Toggle
6.4 EVENT DATA
Figure 12 shows an example of Input (pulses) and Output (data) to explain the Event Data. On changes the status to On at the first signal. Off changes the status to Off at the first signal. Copy lets the status follow the input. Copy Invert lets the status follow the opposite of the input. Copy is used for dimming too by holding the pulse switch pressed for a longer time. Toggle changes the status at the first signal and back at the second signal. It is used in combination with a pulse switch.
6.5 FOLLOW THE TOGGLE LEADER
If two or more targets of the MasterView Easy MkII are configured for one toggle switch, the first event for this switch is the leading toggle event. The other events are the following toggle events. They borrow their state from the leading event. Example: Event 4 is the leading event. The states of event 4,5,6 are 0,1,1 respectively. Operating the toggle switch results in state 1 for event 4 (toggled from 0). Event 5 and 6 borrow state 1 from event 4, so the event states are now 1,1,1 respectively.
6.6 FAVOURITE + CONTROL PAGE
The MasterView Easy MkII Favourites page is designed to monitor the other connected MasterBus devices in one overview. This page shows up to 6 monitoring items on one screen. An example of a monitoring item is the Battery State of Charge, measured by the MasterShunt. These items are selectable from the monitoring tabs of connected MasterBus devices.
For configuration, using the MasterAdjust or System Panel software is necessary to recognize the group and item numbers.
Figure 12: Event Data
Page 15
MONITORING AND CONFIGURATION
EN / MasterView Easy MkII / September 2010 15
6.6.1 Name Favourites page
Enter the maximum 16 character name of your Favourites page.
6.6.2 Areas
Select the number of areas on your Favourites page. 1, 2, 3, 4 or 6 areas on the MasterView Easy are selectable to show your monitoring items. Besides that, 1, 2 or 3 tank levels can be displayed, see also section 6.9.
6.6.3 Devices
Up to 63 connected MasterBus devices are selectable to choose your monitoring items from.
6.6.4 Groups
The monitoring items are ordened in groups, for instance figure 13 shows one group with the name General. Choose the group, starting to count at 1.
6.6.5 Items
Choose the item in the monitoring group of the device concerned. Start to count at 1. So item 1 is the first item in that group. The item will be shown in the area you selected.
6.6.6 Add
Add puts the item into the area you selected. This is done by pressing the button Add.
6.6.7 Example
See figure 13. For instance you have a MasterShunt installed and you want the Battery state of charge to be shown in the first of the six areas on your MasterView Easy. Go to Configuration in the Easy menu. Select Favourites page and name this page. Select 6 areas and then touch Connect to fav. Under Connect to select Area 1. Under Device select your MasterShunt. Select Group no. 1 and Item no. 1. Finally press Add and confirm.
Figure 13: Configuration of Area 1
Add
Page 16
MONITORING AND CONFIGURATION
16 September 2010 / MasterView Easy MkII / EN
6.6.8 Showing the Favourites page
The Favourites page is accessed by pressing the button with the same name, see figure 14.
Figure 14: Favourites page button
NOTE: The Favourites page appears automatically after 20 seconds when the MasterView Easy panel is in the start up screen (device list). This only happens when you actually configured the Favourites page.
See figure 15. The item selected is being shown under Connected favor. The Area 1 device is the MSH MasterShunt. The 1 under Area 1 is the Index. It shows the item you added is available and the connection with the device is present. You can check the index by selecting the menu of the according device and mouse over the item (in this example the MSH MasterShunt: group 1 is Monitoring and item 1 is the State of Charge).
NOTE: If you want to change the item to be displayed in an area, reconfiguring that area is possible.
Figure 15: Favourites page configuration
6.7 CONFIGURING OTHER DEVICES
Monitoring and configuring other devices is possible by selecting a device in the MasterView Easy device list, see section 6.1. Refer to the user’s manual of the connected device for an overview of all available settings. Settings are stored in the memory of the selected device. This means that switching off or disconnecting of the MasterView Easy will not affect the settings of the connected devices. See section
6.2 for the Configuration Lock of all connected devices.
6.8 DIGITAL SWITCHES
The MasterView Easy MkII features 6 digital switches to be used in the Favourites page. Their function is based on event configuration of mainly other devices. The switches, named Switch 1 to 6, can be renamed after their application, see figure 16. An example is Switch 1, named Kitchen. The switches are in the Easy Monitoring screen basically to add them to the Favourites page, see figure 13.
NOTE: To have a switch displayed at the Favourites page, you need to add it! Refer to section 6.6.7 for an example.
Add
Mv Easy X
Backlight
Auto
Favourite
page
Page 17
MONITORING AND CONFIGURATION
EN / MasterView Easy MkII / September 2010 17
6.8.1 Switch configuration
To have a switch really control a channel on the Digital DC 10x10A, you need to perform the event configuration. Figure 17 shows how to let the switch called “Kitchen” control channel 6 of the Digital DC. Now, Kitchen on the Favourites page (see figure 19) toggle switches channel 6.
6.8.2 Feedback configuration
Only switches of the MasterView Easy itself can show feedback information on its Favourites page. See figure 18. For instance Kitchen is Event configured to toggle switch channel 6 of the Digital DC 10x10A. The Digital DC can be Event configured to send a feedback signal to Kitchen if it is really switched On. The “LED” in Kitchen then turns black, see figure 19. In case of alarm, it blinks.
NOTE: Only the MasterView Easy MkII switches can be configured for the Easy MkII feedback function!
6.9 TANKLEVEL INTERFACE
The MasterView Easy MkII features three Favourites page display options for the Tanklevel Interface, see figure 20. Select 3 tank levels and after that, add the group and item to the areas (see section 6.6.8).
Figure 20: Tank levels configuration and displays
Figure 16: Configuration, monitoring of switch 1-6
Figure 17: Switch configuration at the MasterView Easy MkII
Figure 18: Feedback configuration at the Digital DC 10x10A
Figure 19: Favourites page with switch. The circle in the switch functions like a feedback
Kitchen
Favourites X
50% 0% 100%
Page 18
ADDITIONAL INFORMATION
18 September 2010 / MasterView Easy MkII / EN
7 ADDITIONAL INFORMATION
7.1 MASTERADJUST SOFTWARE
For Favourites page settings you need the MasterAdjust or System Panel software. To use MasterAdjust, you need a MasterBus-USB interface for communication between your PC and the MasterBus. See ordering information. See the user manual of the MasterBus-USB interface for detailed information.
Mastervolt MasterAjust software is available as free to download software on the Mastervolt website (www.mastervolt.com
). Features:
System configuration: to adjust the entire
MasterBus network and all connected devices in accordance with your personal preferences, including programming of Event-based commands (see section 6.4);
System Monitor: complete actual overview of
your entire electrical installation;
System logger: data logging instrument to retrieve historical data of your electrical installation.
Figure 21: MasterBus-USB interface
7.2 ORDERING INFORMATION
Part number Description
77040000 MasterBus terminating device* 77040020 MasterBus cable, 0,2m 77040050 MasterBus cable, 0,5m 77040100 MasterBus cable, 1,0m 77040300 MasterBus cable, 3,0m 77040600 MasterBus cable, 6,0m* 77041000 MasterBus cable, 10m 77041500 MasterBus cable, 15m 77042500 MasterBus cable, 25m 77050100 100m / 330ft MasterBus cable (UTP cable) 77050200 50 pcs. modular jacks 77050000 Complete set to assemble MasterBus cables. Delivery includes: 100 meter UTP cable, 50 pcs.
modular jacks and crimping tool
77030100 MasterBus-USB interface, required as interface between your PC and the MasterBus when
using MasterAdjust software.
* These parts are standard included with the delivery of the MasterView Easy
Mastervolt can offer a wide range of products for your electrical installation, including an extended program of components for your MasterBus network. Our website www.mastervolt.com shows an overview of all our products and free downloadable software.
Masterbus – USB interface
Standard USB cable
Page 19
TROUBLE SHOOTING
EN / MasterView Easy MkII / September 2010 19
8 TROUBLE SHOOTING
Contact your local Mastervolt Service Centre if you cannot correct a problem with the aid of the
malfunction table below. See www.mastervolt.com for an extended list of Mastervolt Service Centres.
Failure Possible cause What to do
Display is switched off. Press button. Error in the wiring. Check the MasterBus cables.
No display function.
No powering device available on the MasterBus.
The MasterView Easy must be powered by the network. This means that at least one device in the network should have powering capabilities
(see section 3.3). Display shows ALARM.
A MasterBus device connected indicates an alarm situation.
Check the alarm source shown on the display and
press STOP to stop the alarm or SNOOZE to let
the alarm repeat every 9 minutes. Backlight suddenly changes colour from white to red.
An alarm situation triggers the backlight to turn red. See also section 6.2.
Check the alarm source shown on the display and
press STOP to stop the alarm or SNOOZE to let
the alarm repeat every 9 minutes. Back light does not switch on after touching the screen.
Back light has been set to switch off.
Check MasterView Configuration.
See section 6.1, 6.2.
Back light does not switch off.
Back light settings wrong. Back light settings need to be changed.
Check MasterView Configuration.
See section 6.1, 6.2. No backlight. Backlight switches off after default
2 minutes.
Press one of the buttons or refer to section 6.2 to
adjust the settings of the backlight.
Error in the MasterBus wiring. Check the MasterBus cables. No terminating device placed at the ends of the network.
MasterBus needs a terminating device on both
ends of the network.
Check if connected (see section 3.3).
MasterBus network is configured as a ring network.
Ring networks are not allowed. Check the
connections of the network (see section 3.3).
Slow or no communication.
T-connections in the MasterBus network.
Check if T-connections are made in the network.
T-connections are not allowed (see section 3.3). Touch screen does not react.
Keyboard Lock has been activated. Press button long to unlock keyboard,
see figure 10. Functions are controlled without intention while touch screen is cleaned.
A touch screen reacts at every touch.
Press button long to lock keyboard, see figure 10.
Clean touch screen with a soft cloth. Do NOT use
acids or scourers!
Press button long again to unlock keyboard.
Settings error: maximum number of devices is 63.
If you want to monitor more than 63 devices, you
need to have a second MasterView Easy panel.
The display is in “Selection” mode with another device selected.
Change the setting to “All devices”.
Error in the wiring. Check the MasterBus cables.
One of the connected devices can not be found.
Device not suitable for MasterBus or it is excluded in the “Excluded” mode.
Check whether the device is suitable for
MasterBus. Maybe the MasterBus cable is
connected to a non-MasterBus connector. MasterView Easy is switched off after some time.
The MasterView Easy is set up to switch off automatically, when no button is touched for 1 day.
See section 6.2 for settings (Auto off).
The device name is not correct.
Device name has not yet been set. Adjust device name, see section 6.2.
Page 20
TROUBLE SHOOTING
20 September 2010 / MasterView Easy MkII / EN
Failure Possible cause What to do
Wrong setting of the language at the MasterView Easy.
See section 6.2 for adjustment of the language.
Wrong language is displayed.
Wrong setting of the language at one of the connected devices.
Each separate connected device can have its own
language setting. See user’s manual of the
connected devices. Wrong boat name is displayed.
Wrong setting of the yacht name at the MasterView Easy.
See section 6.2 for setting “Name yacht”.
A set value shown in the display is not correct.
Value has not been set yet or it can not be set.
Go to Configuration and change the value using
arrows. If the value is not adjustable, no arrows
are shown. The Favourites page does not pop up automatically.
You are in configuration and you want to check the Favourites page.
Click the X repeatedly to enter the device list. This
is the MasterView Easy starting screen. It
changes to your Favourites page automatically. Your Favourites page does not show the right parameter
Selecting a device’s monitoring group and item number, you chose another parameter than intended.
Check the user’s manual of the device that
features the selected monitoring parameter.
NOTE: Start to count at 1 for group and item
number! You don’t have the slightest idea where in the menu structure you have ended up.
You just discovered some unexpected screens.
Click the X repeatedly to enter the device list. This
is the MasterView Easy starting screen. It
changes to your Favourites page automatically.
Page 21
SPECIFICATIONS
EN / MasterView Easy MkII / September 2010 21
9 SPECIFICATIONS
9.1 TECHNICAL SPECIFICATIONS
Model: MasterView Easy MkII Article number: 77010305 Delivery includes: Panel, outer casing, MasterBus Terminating device, MasterBus connection
cable (6m/20ft), user’s manual / screws / mounting sticker
Function of instrument: Monitoring, configuration and switch control of devices that are connected to the
MasterBus network
Manufacturer: Mastervolt Amsterdam, the Netherlands
Readout: By means of an LCD touch screen Available languages: English, Nederlands, Deutsch, Français, Castellano, Italiano, Norsk, Svenska,
Suomi, Dansk.
Powering capabilities: No, needs to be powered via the MasterBus (at least one of the connected
devices should have powering capabilities) MasterVision compatible: No Power consumption: Off: 16 mW On: 160 mW (backlight off); 900mW (backlight on) Dimensions: See section 9.2 Required depth: 38 mm minimum Weight: 230 g (0.50 lb) Protection degree: IP 21
Page 22
SPECIFICATIONS
22 September 2010 / MasterView Easy MkII / EN
9.2 DIMENSIONS
Fig. 22: Dimensions in mm (inch) of the panel without and with outer casing.
Page 23
EC DECLARATION OF CONFORMITY
EN / MasterView Easy MkII / September 2010 23
10 EC DECLARATION OF CONFORMITY
Manufacturer Mastervolt Address Snijdersbergweg 93
1105 AN Amsterdam The Netherlands
Herewith declares that:
Product: 77010305 MasterView Easy MkII
Is in conformity with the provision of the EC EMC directive 89/336/EEC and amendments 92/31/EEC, 93/68/EEC. Low voltage directive: 2006/95/EC
The following harmonised standards have been applied: