MGH5000DI, MGH5000DIE, MGH6000D, MGH6000DI, MGH7000D, MGH7000DI, and MGH10000A
IMPORTANT: Read and understand this manual before operating or servicing
generator. Improper use of generator can cause serious injury. Keep this
manual for future reference.
R
PORTABLE GASOLINE GENERATORS
SAFETY
INFORMATION
WARNINGS
IMPORTANT: Read this owner’s
manual and the engine owner’s
manual carefully. Become familiar with this generator before trying to operate or service it. Know
its uses, limitations, and any hazards involved. Improper use of
generator can cause severe injury or death from explosion, fire,
burns, electrical shock, or carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Engine exhaust contains poisonous carbon
monoxide gas. Overexposure will cause loss
of consciousness and will lead to death. Use
only in well-vented areas. Make sure area
has plenty of free-moving, fresh, outside
air. Never run generator in an enclosed or
confined area. Never run generator inside
occupied building.
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness,
and nausea. If you have these signs, getfresh air at once! Some people are more
affected by carbon monoxide than others.
These include pregnant women, persons
with heart or lung disease or anemia, those
under the influence of alcohol, and those at
high altitudes. Make certain you read and
understand all warnings. Keep this manual
for reference. It is your guide to safe and
proper operation of this generator.
Safety information appears throughout these
instructions. Pay close attention to them.
Below are definitions for the safety information listed throughout this manual.
DANGER: indicates a hazard which will
cause severe personal injury, death, or substantial property damage if you ignore warning
WARNING: indicates a hazard which can
cause severe personal injury, death, or substantial property damage if you ignore warning.
CAUTION: indicates a hazard which will
or can cause minor personal injury or property damage if you ignore warning.
.
1.Gasoline presents a hazard of fire or explosion. Gasoline is flammable. Its vapor is explosive.
• Keep fuel out of children’s reach.
• Refuel generator in a well-vented
area. Do not fill fuel tank in the dark.
Do not refuel while engine is running. Unhook all electrical loads and
shut off engine before refueling.
• Do not overfill fuel tank. Always al-
low room for fuel to expand. If you
overfill tank, fuel can overflow onto
hot generator. This can cause fire or
explosion. After refueling, tightly
close fuel tank cap.
• Do not spill fuel. Fuel or fuel vapor
may ignite. If fuel spills, make sure
area is dry before starting engine.
• Never smoke in refueling area. Never
allow open flames or sparks in area.
• Store fuel in approved container.
Store fuel in a well-vented area free
of open flames or sparks.
2.Guard against fire hazard. Keep operation area well-vented. Keep generator
at least three feet away from any object. Do not place flammable objects
near generator.
• Do not use generator where flam-
mable vapors are present. Some vapors are heavier than air. These vapors settle in low-lying places.
• Do not use generator in enclosed
spaces. This includes motor home or
RV generator compartments.
3.
Guard against electric shock. Generator
produces high voltage. This high voltage
can cause severe electric shock. Only responsible adults should use generator.
• Properly ground generator before
starting.
• Never let anyone operate or service
generator without proper instructions.
• Avoid contact with live terminals or
bare wires.
• Do not use generator outdoors in rain
or snow.
• Do not use generator near standing
water or snow.
• Do not use if generator is wet or
damp.
• Do not use generator in highly con-
ductive areas. These areas include
metal decking and steelwork.
• Only use grounded extension cords.
• Do not use any worn or damaged
electric cords. Electric shock or damage to generator may result.
• Do not wear damp clothing or wet
shoes when using generator.
4.Guard against burns. Hot engine parts
can cause severe injury. Use caution
and remain alert when using generator.
• Keep children and animals away
from generator while it is running or
hot.
• Keep all covers and shields in place.
Keep them tightly secured.
• The muffler becomes very hot dur-
ing operation. The muffler remains
hot for a while after shutdown. Do
not touch muffler while it is hot. Do
not let muffler touch anything flammable. Let engine cool before transporting or storing.
5.Have standby installation to home or
building performed by a licensed electrician. Do not let anyone else wire into
a utility circuit. Personal injury , equipment damage, or damage to home could
occur.
6.Never connect generator to any existing electrical circuits. The generator
output will back-feed into the utility
power line. This may electrocute a
power company line repair person.
Also, if generator is powering electrical circuits, the chance of an electrical
fire exists.
7.Battery gives off explosive gases. Keep
sparks, flames, and cigarettes away. Do
not remove or install battery cables
when engine is cranking or running.
Only service or use battery in a wellvented area.
8.Battery contains sulfuric acid. Battery
acid is poisonous if swallowed. Contact with skin or eyes may cause severe
burns. Do not tilt generator with battery installed. Tilting could cause battery acid to spill. W ear protective clothing and face shield when servicing.
Keep out of children’s reach.
2
106813
OWNER’S MANUAL
SAFETY
INFORMATION
Continued
9.
Only a qualified electrical service person should service and repair generator.
• Generator produces high voltage.
Use extreme caution when working
on electrical parts.
• Always remove spark plug wire from
spark plug before servicing. This will
prevent accidental starting.
•
When working on generator, avoid hot
muffler, exhaust manifold, and engine
parts. Severe burns may occur.
• Do not work on generator when tired.
• Use only factory approved replacement parts.
10. Store generator in a well-vented area.
Make sure fuel tank is empty. Never
store with fuel in tank. Vapors may
reach an open flame or spark. Fire or
explosion may result.
11. Never operate generator
• if engine speed changes greatly
• if engine misfires often
• if powered items overheat
• if electrical output drops
• if it is sparking
• if it produces smoke or flames
• if it vibrates at high levels
• if it has a damaged receptacle
12. Keep generator and nearby areas clean.
• Keep generator free of oil, mud, and
other foreign matter.
• Remove anything that creates slip-
pery areas around generator.
• Remove oily rags and other items
that create fire hazards.
• Keep a fire extinguisher nearby.
Make sure it is rated ABC by the
NFPA. They are good for all uses.
Consult your local fire department.
• Keep fire extinguisher well main-
tained. Be familiar with its use.
13. Know how to stop engine quickly.
Know how to use all controls.
14. Prolonged exposure to loud noise can
cause hearing loss.
Master portable generators are rugged and
compact. These models provide dependable, trouble-free service. The alternators
are brushless with revolving fields. Honda
gasoline engines provide long life under
heavy use. Honda engines have overhead
valves (OHV). This provides high performance with lower fuel consumption. These
engines are governed to maintain engine
speed of 3600 RPM under load. 3600 RPM
engine speed provides 120/240V, 60 Hz
power.
Additional Features
• Circuit breaker protection
• Spark-arresting muffler (except model
MGH10000A)
• Large fuel tank
• Oil alert system
• Electric starter (models MGH5000DIE,
MGH7000D, MGH7000DI, and
MGH10000A only)
• 15-Amp ground fault circuit interrupter
(GFCI) receptacle (Except HWI3000
Model)
UNPACKING
1.Remove generator from carton.
2.Remove any protective packaging applied to generator for shipment.
3.Check for loose or missing parts. Check
for shipping damage. If any parts are
missing or damaged, promptly inform
dealer where you bought generator.
4.Battery cables are supplied for models
MGH5000DIE, MGH7000D,
MGH7000DI, and MGH10000A only.
These cables are in a separate bag inside generator carton. You must install
these cables to engine. See Battery,
page 8 for installation instructions.
VENTILATION
DANGER: Use only in wellvented areas. Make sure area has
plenty of free-moving, fresh, outside air. Never run generator in
an enclosed or confined area.
Never run generator inside occupied building. Engine exhaust
contains poisonous carbon monoxide gas. Overexposure will
cause loss of consciousness and
will lead to death.
This generator needs cooling air to run properly. Never block free-flowing, cooling air
to generator. Overheating will occur without cooling air. This will damage the generator. Keep generator at least three feet
away from any object.
DUST, DIRT, RAIN,
AND SNOW
WARNING: Do not use generator outdoors in rain or snow.
Do not use generator near standing water or snow. Do not use if
generator is wet or damp. Operating generator in these conditions increases the risk of electrocution. Severe injury or death
can occur.
Do not use generator in extremely dusty or
dirty conditions. This will severely affect its
life. Keep generator clean. Do not allow
dust, dirt, rain, or snow to collect on it.
Protect generator from outdoor elements.
HIGH AND LOW
TEMPERATURE
OPERATION
Air temperature affects generator output.
Output drops 1% for each 10° temperature
rise above 60° F. Very low temperatures may
make the engine hard to start. See engine
owner’s manual for more information.
ratings 3 1/2% for each 1000 feet above sea level and 1% for
each 10° Fahrenheit rise above 60°F.
106813
5
R
PORTABLE GASOLINE GENERATORS
GENERATOR
FEATURES
OIL ALERT SYSTEM
The oil alert system protects the engine from
low oil damage. This system automatically
shuts down the engine and prevents engine
restarting if the oil level falls too low.
Note:
When this happens, the engine switch
remains in the ON position. The oil alert
system is wired into the ON/OFF Switch.
If this system shuts down the engine, the
engine will not start until you add oil. Add
oil to engine (see Engine Oil, page 7).
Note:
Operate generator on a level surface.
If not level, the oil may flow away from the
oil level sensing device. This will cause the
oil alert system to shut down engine.
See engine owner’s manual for more
information.
Model
MGH3000PR
FULL POWER SELECTOR
SWITCH
All models except HWI3000, MGH3000,
MGH3000PR, MGH7000D, MGH7000DI,
and MGH10000A have a full power selector
switch on the control panel. The switch has
two positions: 120 VOLT ONLY, and 120/
240 VOLT.
120 VOLT ONLY: This position sends full
power to the 120V receptacles only. 240V
power is not available. Use this position
when powering 120V items only.
120/240 VOLT: This position sends full power
to the 120/240V receptacle. It also powers the
120V receptacles at reduced wattage capacity.
IMPORTANT:
selector switch while powering electrical
items. Unplug all items before moving switch.
Failure to do so can damage switch. Models
HWI3000, MGH3000, MGH3000PR,
MGH7000D, MGH7000DI, and
MGH10000A do not have this switch. These
models provide full power to all receptacles.
Do not move the full power
ELECTRIC START
(Models MGH5000DIE,
MGH7000D, MGH7000DI, and
MGH10000A)
Models MGH5000DIE, MGH7000D,
MGH7000DI, and MGH10000A have electric starters. A battery is not supplied with
generator. You must provide a 12-volt, 32amp-hour battery. For more battery information, see Battery, page 8.
GROUND FAULT CIRCUIT
INTERRUPTER RECEPTACLE
All models (Except HWI3000) have a 120volt ground fault circuit interrupter (GFCI)
receptacle. The GFCI receptacle is on the
control panel or top cover of alternator (models MGH3000 and MGH3000PR only). The
GFCI protects you against hazardous electrical shock caused when your body becomes a
path through which electricity travels to reach
ground. This could happen when you touch an
appliance or cord that is ‘live’ through faulty
mechanism, damp or worn insulation, etc.
When protected by the GFCI, you may still
feel a shock, but the GFCI should cut it off
quickly. A person in normal health should
not receive serious injury.
very small children may still be affected.
Note:
Infants and
Models HWI3000,
MGH3000, MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH6000D,
and MGH6000DI
Models
MGH5000DIE,
MGH7000D,
MGH7000DI, and
MGH10000A
Figure 2 - Engine Switch Location
ENGINE SW
ON
OFF
HONDA
OFFONSTART
ENGINE SW
CIRCUIT
BREAKER
120 VOLT ONLY
Position
Figure 3 - Full Power Selector Switch
120/240 VOLT
Position
AUTO-IDLE SYSTEM
The Auto-Idle System allows the engine to
idle down or run at a slower speed when the
generator is not being used to supply power.
The Auto-idle system can be turned ON or
OFF by a rocker switch on the control panel.
When the switch is in the OFF position, the
engine runs at full speed all of the time. When
the switch is in the ON position, the engine
slows down to idle speed until an electrical
load is applied. When a load is applied to the
generator (an electrical item is plugged in and
turned on) the engine speeds up to the preset
speed required to produce the correct voltage.
IMPORTANT:
1 Amp is required to disengage the auto idle
solenoid and cause the engine to come up to
speed for correct voltage. Powering items at
reduced engine speed will damage generator and powered items.
A minimum current load of
Test Procedure
Check the GFCI receptacle every month.
This insures it is working right.
1.Push black TEST button. Red RESET
button should pop out. This should trip
GFCI, resulting in no electrical power
at receptacle. Verify this by plugging
test lamp with good bulb into receptacle. If lamp does not work, GFCI receptacle is good.
WARNING: If RESET button
does not pop out, do not use the
GFCI receptacle. Contact a qualified electrician for repairs.
6
106813
OWNER’S MANUAL
GENERATOR
FEATURES
Continued
2.If the GFCI receptacle tests okay, restore power by pushing the RESET
button back in. The test lamp should
work at this time
must press the RESET button firmly
and fully. It should lock into place. If
the GFCI does not lock into place, do
not use receptacle. Contact a qualified
electrician for repairs.
Figure 4 - GFCI Receptacle
ENGINE CIRCUIT BREAKER
(Models MGH5000DIE,
MGH7000D, MGH7000DI, and
MGH10000A)
This circuit breaker, or fuse, protects the
battery charging circuit. A short circuit will
trip the circuit breaker. The circuit breaker
will also trip if you install battery wrong.
Push circuit breaker button to reset. On
Model MGH10000A, the fuse is located
inside of the Keyswitch box.
Engine Circuit
Breaker Button
Figure 5 - Engine Circuit Breaker
. IMPORTANT:
RESET
TEST
OFFONSTART
ENGINE SW
CIRCUIT
BREAKER
ON/push OFF
You
RECEPTACLE CIRCUIT
BREAKER
The circuit breakers protect the receptacles
and alternator. Overloading generator will
trip circuit breaker. A short circuit in item
being powered will also trip breaker. If this
occurs, unplug electrical load from receptacle. Let circuit breaker cool down. Push
circuit breaker button to reset.
Electric motors need higher starting current.
They require up to three-times their rated
wattage to start. The starting current needed
may be too high. This can cause nuisance
circuit breaker tripping. To help prevent
this, start electric motors first. Connect additional items to generator after starting
motors. If this continues to happen, reduce
the total generator load.
Normal
Figure 6 - Receptacle Circuit Breaker
Button
Note:
20
Tripped
20
High ambient temperature will cause
nuisance tripping.
ENGINE OIL
We ship the generator without oil in the
engine crankcase. You must add oil before
starting engine. See engine owner’s manual
for specific oil type.
CHECKING OIL LEVEL AND
ADDING OIL
Follow steps below to check oil level. Make
sure engine is level and stopped.
1.Remove dipstick (see Figure 7). Wipe
dipstick clean.
2.Insert dipstick into oil filler neck. Do
not screw it in. Oil level should be at
top of filler neck. Oil should cover most
of dipstick. For Model MGH10000A
only, the oil should be between the two
dots on dipstick.
3.If level is low, fill to top of oil filler neck
(see Figure 7). For Model MGH10000A
only, fill to top dot on dipstick. Only use
oil recommended in engine owner’s
manual.
Note:
If oil level is too low, oil alert system
will shutdown engine and prevent engine
from restarting.
WARNING: Gasoline presents
a hazard of fire or explosion.
Gasoline is flammable. Its vapor
is explosive.
• Keep fuel out of children’s
reach.
•
Refuel generator in a wellvented area. Do not fill fuel tank
in the dark. Do not refuel while
engine is running. Unhook all
electrical loads and shut off
engine before refueling.
• Do not overfill fuel tank. Al-
ways allow room for fuel to
expand. If you overfill tank, fuel
can overflow onto hot engine.
This can cause fire or explosion. After refueling, tightly
close fuel tank cap.
• Do not spill fuel. Fuel or fuel
vapor may ignite. If fuel spills,
make sure area is dry before
starting engine.
• Never smoke in refueling area.
Never allow open flames or
sparks in area.
• Store fuel in approved con-
tainer. Store fuel in a wellvented area free of open flames
or sparks.
Use clean, fresh, unleaded gasoline. Use
gasoline with octane rating of 86 or higher.
Service station gasoline pumps should display the octane rating. Using gasoline with
lower octane level could damage engine.
Avoid getting dirt, dust, or water in fuel
tank. Do not mix oil with gasoline.
See engine owner’s manual for more
information.
106813
7
R
PORTABLE GASOLINE GENERATORS
HANDLES AND
TOP COVER
(Model MGH10000A)
Follow the steps below to attach the handles
and top cover to Model MGH10000A:
1.Remove the two bolts, lock nuts, and
washers holding side panels to control
panel end of roll cage. Insert bolts with
washers through two holes in the
handle and then back through roll cage
and side screen panels (See Figure 8).
Tighten the lock nuts against the side
screen panels.
2.Place top cover on top of generator roll
cage with notch on control panel side.
Use four #8 sems screws provided to
attach cover to roll cage (See Figure 9).
Roll Cage
FUEL
F
Bolts
Washers
Handle
Lock Nuts
BATTERY
(Models MGH5000DIE,
MGH7000D, MGH7000DI, and
MGH10000A)
WARNING: Battery gives off
explosive gases. Keep sparks,
flames, and cigarettes away. Do
not remove or install battery
cables when engine is cranking
or running. Only service or use
battery in a well-vented area.
WARNING: Battery contains
sulfuric acid. Contact with skin
or eyes may cause severe burns.
Do not tilt generator with battery
installed. Tilting could cause battery acid to spill. Wear protective
clothing and face shield when
servicing. Keep out of children’s
reach.
• If battery acid gets on your
skin, wash with water.
• If battery acid gets in your eyes,
flush with water at least 15
minutes. Call a doctor at once.
Battery acid is poisonous.
• If swallowed, drink large
amounts of water or milk. Follow with milk of magnesia or
vegetable oil. Call a doctor at
once.
Always wear safety glasses when working
with battery. Make sure battery terminals
are clean. Make sure cable connections are
tight.
Always shut down engine before removing
or attaching battery cables. Always remove
the negative (–) cable first. Always attach
negative (–) cable last.
INSTALLING BATTERY
CABLES TO ENGINE
1.Attach the red, positive (+) battery
cable to the starter solenoid on engine
(see Figure 10). The starter solenoid is
located directly above the starter on
Model MGH10000A. This cable is factory installed.
CAUTION: Do not over tighten
positive terminal on starter solenoid. Positive terminal could rotate and cut into negative terminal, causing a short.
2.Attach the black, negative (–) battery cable
to the engine block. Use the bolt, nut, and
two washers provided with the battery
cables. Use long mounting hole on opposite side of engine from starter solenoid.
Attach cable as shown in Figure 11.
Figure 8 – Attaching Handles to Roll Cage
SEMS Screws
Top Cover
FUEL
F
SEMS
Screws
Figure 9 – Attaching Top Cover to Roll
Cage
CAUTION: If you remove battery, insulate the red, positive (+)
battery cable terminal. Insulate
with electrical tape. Exposed terminal may spark when generator
runs.
IMPORTANT:
Make sure battery connections are the correct polarity. Electric start
generators use negative ground, 12-volt DC
starting system.
Models MGH5000DIE, MGH7000D,
MGH7000DI, and MGH10000A have an
electric starter. A battery is not supplied
with generator. You must provide a 12-volt,
32-amp-hour battery. The positive and negative battery cables are supplied with generator. You must install these cables before
mounting battery.
WARNING: You must properly earth-ground generator before starting. This will help guard
against deadly electric shock.
Only use grounded plugs with
generator. Only use grounded extension cords. Only use threewire or double-insulated power
tools.
Grounding generator helps prevent electric
shock from a ground fault condition. Locate
ground lug on end of generator housing (see
Figure 16). Attach a #10 stranded-copper
ground wire to ground lug. Drive grounding
point into ground. Grounding point can be a
stake, grounding rod, or pipe. Grounding
point should be copper or brass. Attach
ground wire to grounding point. You must
supply the ground wire and grounding point.
These do not come with generator. Follow
the National Electrical Code and all state
and local codes. Consult your power company or a licensed electrician.
WARNING: For a grounding
point, do not use metal pipe being used to carry combustible
materials or gases.
WARNING: Have standby installation performed by a skilled,
licensed electrician. Do not let
anyone else wire into a utility
circuit. Personal injury, equipment damage, or damage to home
could occur.
IMPORTANT:
This generator will not
power your entire home. Most home utility
electric service is more than 60 amps. This
will exceed generator output. Only power
needed items during a power outage. Make
sure total wattage of electrical load does not
exceed rated wattage of generator.
You may need to use this generator as a
standby power source. During a power outage, the generator will power selected items
in a building. Have generator and additional
wiring installed by a skilled, licensed electrician. This is not a do-it-yourself job. Follow all local codes.
WARNING: The electrician
must install a double-throw transfer switch. This isolates existing
electrical circuits from the utility
power line. If not isolated, generator output will back-feed into
utility power line. This may electrocute a power company line
repair person.
DETERMINING
ELECTRICAL LOAD
FOR GENERATOR
You must decide what electrical load your
generator can power. Do this before using
generator. Use the following four-step
method. It will help you select a load that is
not too large. Make sure total wattage of all
electrical loads does not exceed rated wattage of generator. For rated wattage of your
generator, see Specifications, page 5. Electric motors present a special problem when
figuring load. Read Step 3 carefully.
1.Make two lists of items you want powered by generator. List all motors and
motor powered appliances in one. List
all lights, small appliances, etc. in the
other. For standby service to home or
building, only include items you must
power.
2.Enter running watts of each item except motors. The light bulb or appliance nameplate lists its wattage. Remember, 1KW = 1000 watts.
Note:
The
nameplate may not list wattage. It may
only list volts and amps. The formula
for finding wattage is: Volts x Amps =
Watts. For example: An appliance
nameplate states 3 amps at 120 volts. 3
amps x 120 volts = 360 watts.
3.Electric motors present a special problem. They require up to three-times
their rated wattage to start. Chart 2,
below, shows starting watts for differ-
ent size motors. For example: an electric motor nameplate states 5 amps at
120 volts. 5 amps x 120 volts = 600
watts running. Multiply this figure by
3. This will show the starting watts
needed. 600 watts x 3 = 1800 watts to
start. When figuring the generator load
for motors, you must use the starting
watts figure. Do not use the running
watts figure.
Note:
Some motors require nearly the same wattage to run as
to start. These items include saws,
drills, hair dryers, and food mixers. See
Chart 1 for typical appliance wattage
examples.
4. Add watts and starting watts of all
items. This total must not be larger than
the rated wattage of your generator. It
is a good idea to have up to 25% extra
capacity for future needs or extra
equipment.
Chart 1 - Typical Electric Appliance Wattages
Running Starting
EquipmentWattsWatts
Light bulb (100W)100100
Radio150150
Fan200600
Television400400
Furnace fan
* – Always use starting watts, not running watts, when figuring correct electrical load.
x – Motors of higher horsepower are not generally used.
10
106813
OWNER’S MANUAL
OPERATION
GENERAL INFORMATION
This generator is not large enough to power
your entire home. Do not connect generator
to any existing electrical circuits. Plug items
directly into generator receptacles. Do not
exceed amperage rating of receptacles. Only
use grounded cords.
DANGER: Use only in wellvented areas. Make sure area has
plenty of free-moving, fresh, outside air. Never run generator in
an enclosed or confined area.
Never run generator inside occupied building. Engine exhaust
contains poisonous carbon monoxide gas. Overexposure will
cause loss of consciousness and
will lead to death.
DANGER: Never connect generator to any existing electrical
circuits. The generator output will
back-feed into the utility power
line. This may electrocute a power
company line repair person. Also,
if generator is powering electrical circuits, the chance of an electrical fire exists.
Note:
We supply the engine owner’s manual
with generator. Refer to that manual for
questions concerning engine operation.
Model MGH10000A also has a 120/240V,
50-amp receptacle (see Figure 17).
Model HWI3000 has only the 120V, 20amp duplex receptacle.
Models MGH3000 and MGH3000PR have
only the 120V, 15-amp GFCI duplex
receptacle.
120V, 15-Amp GFCI Duplex
120V, 15-Amp Duplex
120/240V, 20 or 30Amp Twist-Lock
120 VOLTS
RESET
TEST
120
ONLY
120
240V
ENM
00000005
HOURS 1/10
120V, 30-Amp
Twist-Lock
RESET
240 VOLTS
RESET
RESET
RESET
POWER CORD AND PLUG
REQUIREMENTS
120V, 30-amp twist-lock receptacle
• NEMA L5-30P plug
• Three-wire, 30-amp cord
120/240V, 20 or 30-amp twist-lock
receptacle
• NEMA L14-20P (20-amp) or L14-30P
(30-amp) plug
• Four-wire, 20-amp or 30-amp cord
120/240V, 50-amp receptacle
• NEMA L14-50P
• Four-wire, 50-amp cord
RESET
RESET
USING RECEPTACLE
Note:
Do not exceed amperage rating of
receptacles. Exceeding rating will trip receptacle circuit breaker.
Use receptacles properly. Improper use could
damage generator. Use only grounded extension cords. Power only grounded or doubleinsulated items. Do not overload receptacles.
All generators (except models HWI3000,
MGH3000, and MGH3000PR) have the following receptacles (see Figure 17):
• 120V, 15-amp GFCI duplex receptacle
• 120V, 30-amp twist-lock receptacle
• 120/240V, 20 or 30-amp twist-lock
receptacle
• 120V, 15-amp duplex receptacle
106813
120/240V, 50-Amp
(Model MGH10000A only)
Figure 17 - Receptacle Locations
11
Figure 18 - Cord and Plug Configurations
Continued
R
PORTABLE GASOLINE GENERATORS
OPERATION
Continued
PRESTART
Operate generator on a firm, dry, and clean
surface. The surface must be level. Protect
generator from heavy dust, sand, dirt, rain,
or snow. Do not locate generator near standing water and snow. Make sure area is wellvented.
WARNING: Only responsible
adults should use generator.
Never let anyone operate generator without proper instructions.
Note:
If oil level is too low, oil alert system
will keep engine from starting (see Oil AlertSystem, page 6). Make sure oil level is full
before starting. See Engine Oil, page 7.
Before starting the engine, disconnect all
electric loads from generator.
STARTING
IMPORTANT:
The throttle is locked in preset position. Do
not adjust throttle. Preset position lets engine run at 3600 RPM under load. The
engine must maintain 3600 RPM for generator to create correct voltage. Running
engine at lower speeds will damage generator and powered items.
all models except MGH3000PR or
MGH10000A (see Figure 19). Pull
choke rod out for Model MGH3000PR
(see Figure 20) or choke button out for
Model MGH10000A (see Figure 21).
This closes the choke.
Note:
if engine is warm or air temperature is
high.
The engine speed is preset.
Never start generator with
Y ou may not need to close choke
4.Start the engine.
A. Recoil Starter
Move engine lever or turn engine
switch to the ON position (see Figures
22 and 23). Remove slack from starter
rope by lightly pulling starter grip.
Next, pull starter rope briskly.
IMPORTANT:
Do not let starter grip
snap back against engine. Return it gently. This will prevent damage to starter .
Note:
If engine does not start, check
the oil in the crankcase. Add oil as necessary. Be sure engine is on a level sur face. See Oil Alert System, page 6.
B. Electric Starter (Models
MGH5000DIE, MGH7000D,
MGH7000DI, and MGH10000A Only)
Turn the engine switch to the START
position (see Figure 24, page 13). Hold
it there until engine starts. When engine starts, let switch return to the ON
position.
IMPORTANT:
Do not use electric
starter more than five seconds. Starter
motor damage may occur. If engine
fails to start, release the switch and wait
ten seconds. After ten seconds, try starting again.
Note
: If engine does not start, check
the oil in the crankcase. Add oil as necessary. Be sure engine is on a level sur face. See Oil Alert System, page 6.
5. As engine warms up, slowly move
choke lever fully to the right (see Figure 25, page 13). This opens the choke.
On Model MGH10000A, the choke
will automatically open.
Choke Lever (Closed Position)
Fuel Valve Lever (ON Position)
Figure 19 - Fuel Valve Lever On, Choke
Lever Closed (Model MGH4000C Shown)
Choke Rod
Pulled Out
(Closed
Position)
Figure 20 - Choke Rod Closed (Model
MGH3000PR Only)
Figure 25 - Choke Lever Opened (Model
MGH7000D Shown)
ENGINE SW
CIRCUIT
BREAKER
ON/push OFF
OWNER’S MANUAL
Note:
The 250 Volt/50 Amp receptacle
is not connected through the Auto-Idle
circuit. The Auto-Idle switch must be
turned off to get full power out of this
receptacle (see Figure 26).
6.The Auto-Idle system should be turned
OFF when generator is shut down.
Adjusting the Idle Speed
IMPORTANT:
• If the idle speed becomes too high.
• If the engine idle speed will not regulate (en-
gine idles and speeds up again and again).
1.Turn Auto-Idle switch OFF. Start engine. Allow engine to warm up with no
load for five minutes.
WARNING: Always set the idle
speed before turning on the AutoIdle. If idle speed is not set, the
larger resistor on the control board
may become hot. Heat from the
resistor may damage the protective coating on the control board.
Adjust the idle speed only:
8.Turn Auto-Idle switch ON. Make sure
solenoid is engaged. When engaged, the
punger is pulled back into the solenoid.
9.If the engine speed is too slow , the engine will want to "hunt" or speed up
and slow down repeatedly. When this
occurs, increase engine speed by adjusting throttle stop screw on carburetor
(refer to Carburetor Adjustment in
Honda Engine Manual).
10. Replace the engine linkage cover
(Models MGH4000CI, MGH5000DI,
MGH5000DIE, MGH6000DI, and
MGH7000DI).
Solenoid Mounting
Bracket
ENGINE
OFF
M8 Nut
AUTO-IDLE OPERATION
IMPORTANT:
trical loads connected. Start engine before
adding electrical loads.
1. If engine is cold, turn the Auto-Idle
switch OFF (see Figure 26).
2.Start engine. Allow engine to warm up
with no load for five minutes.
3.Turn Auto-Idle switch ON. Engine will
slow to idle speed. Engine idle speed
is preset. Idle speed adjustment should
not be necessary.
4.Operate generator according to specifications outlined in owner's manual.
5.Engine will automatically increase to
normal operating speed when you plug
load into any generator outlet.
3.Push plunger into solenoid body to manually engage solenoid and set idle speed.
4.Loosen the M8 nut that holds the solenoid mounting bracket to the generator
(Models MGH4000CI, MGH5000DI,
MGH5000DIE, MGH6000DI, and
MGH7000DI. See Figure 27). Do not
loosen bolt that holds the solenoid
mounting bracket to the generator on
Model MGH10000A (see Figure 28).
5.Slowly pull solenoid bracket away from
engine (on Model MGH10000A this will
require bending the bracket slightly).
6.With a volt meter, check the no-load
output voltage at the 120-volt duplex
receptacle. At proper idle speed (2680
minimum RPM) the meter should read
50-60 volts. Lower settings will cause
the Auto-Idle to not operate properly.
7. After reaching proper idle speed,
tighten M8 nut to secure solenoid
mounting bracket (Models
MGH4000CI, MGH5000DI,
MGH5000DIE, MGH6000DI, and
MGH7000DI (see Figure 27).
Figure 27 - Solenoid Bracket Location,
Models MGH4000CI, MGH5000DI,
MGH5000DIE, MGH6000DI, and
MGH7000D Only
Solenoid
Mounting
Bracket
Bolt
Figure 28 - Solenoid Bracket Location,
Model MGH10000A OnlyFigure 26 - Control Panel
106813
13
R
PORTABLE GASOLINE GENERATORS
OPERATION
Continued
HIGH ALTITUDE OPERATION
This generator will not perform well at high
altitudes without proper adjustment. See
engine owner’s manual for details.
ADDING ELECTRICAL
LOADS
IMPORTANT:
Make sure total wattage of all electrical loads
does not exceed rated wattage of generator.
Overloading may shorten generator life. It
could also cause internal damage to generator. Overloading will trip circuit breaker.
IMPORTANT:
MGH3000, MGH3000PR, MGH7000D,
MGH7000DI, and MGH10000A) Keep full
power selector switch in the 120 VOLT ONLY
position if only powering 120V items. Only
move switch to 120/240 VOLT position if
powering 240V items.
1. Check items to be powered. Their
nameplate lists their wattage ratings.
Note:
trical motors are misleading. They may
require up to three-times their rated wattage to start. You must figure total electrical load wattage. Make sure total wattage
of all electrical loads does not exceed rated
wattage of generator. See DeterminingElectrical Load For Generator, page 10.
2. Start engine. Let engine reach full
speed.
3.Connect electrical loads one at a time.
If the load consists of electric motors,
start them first. Always start the largest first. Start each motor individually .
Do not overload generator.
(All models except HWI3000,
The wattage ratings for some elec-
STOPPING ENGINE
IMPORTANT:
The throttle is locked in preset position. Do
not adjust throttle.
Follow the steps below to stop engine.
1.Remove all electrical loads from generator (see Disconnecting ElectricalLoads). Remove electrical loads one at
a time.
2.Let engine run for two or three minutes after removing electrical loads.
This lets engine cool slightly.
3.Turn engine switch to the OFF position (see Figure 29).
4. Turn fuel valve lever off except on
Model MGH3000PR. Do this by moving valve lever fully to the left (see Figure 30).
Model
MGH3000PR
Models HWI3000,
MGH3000, MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH6000D
and MGH6000DI
The engine speed is preset.
ENGINE SW
ON
OFF
Fuel Valve Lever
(Off Position)
Figure 30 - Fuel Valve Lever Off (Model
MGH7000D Shown)
DISCONNECTING ELECTRIC
LOADS
Remove electrical loads one at a time. Remove voltage sensitive items first. Voltage
sensitive items include TVs, VCRs, and
other home electronic items.
HONDA
Models
MGH5000DIE,
MGH7000D,
MGH7000DI, and
MGH10000A
Figure 29 - Engine Switch In OFF Position
14
OFFONSTART
ENGINE SW
CIRCUIT
BREAKER
ON/push OFF
106813
OWNER’S MANUAL
MAINTENANCE
AND REPAIRS
WARNING: Only a qualified
electrical service person should
service and repair the alternator
on this generator. Use only factory approved replacement parts.
CAUTION: The engine speed
is preset. The throttle is locked in
preset position. Do not adjust
throttle. Preset position lets engine run at 3600 RPM under load.
The engine must maintain 3600
RPM for generator to create correct voltage. Running engine at
lower speeds will damage generator and powered items.
CAUTION: Shut off generator
before performing maintenance.
IMPORTANT:
servicing. Never turn generator upside down
or stand it on end to service.
Note:
We supply the engine owner’s manual
with generator. Refer to that manual for
questions concerning engine maintenance
and repairs.
Non-engine parts require little maintenance.
Keep generator clean. Use a damp cloth to
clean outside surfaces. Never use water to
clean generator. Water can cause damage to
internal parts. Use vacuum to clean air inlet
and outlet louvers of alternator.
Keep generator level when
STORAGE
WARNING: Remove all fuel
from fuel tank before storing generator. Store fuel in approved container. Store fuel in a well-vented
area free of open flames or sparks.
WARNING: The muffler becomes very hot during operation.
The muffler remains hot for a
while after shutdown. Let engine
cool before storing.
IMPORTANT:
in storage. Never store generator upside
down or standing on end.
Note:
We supply the engine owner’s manual
with generator. Refer to that manual for
questions concerning engine storage.
Use a fuel additive, such as STA-BIL® or an
equivalent, when storing generator with fuel
in fuel tank. This will minimize fuel gum
deposits from forming in engine.
Cover and store generator in a clean, dry
place. Do not expose generator to extreme
high or low temperatures during storage.
Keep generator level while
TROUBLESHOOTING
Note:
For additional help, visit DESA
International’s technical service web site
at www.desatech.com.
OBSERVED PROBLEM
No voltage when starting generator with no
electrical load
Voltage is less than normal voltage with no
electrical load
Voltmeter reading more than 10% high with
no electrical load
Voltmeter reading correct with no electrical
load, but more than 10% low when electrical load is added
WARNING: Only a qualified electrical service person should service
and repair generator. Use only factory approved replacement parts.
Note:
See engine owner’s manual for engine troubleshooting.
POSSIBLE CAUSE
1. Defective capacitor
2. Winding short circuit or loose
connections
3. Defective rotor diode
4. Loss of residual magnetism
1. Engine speed too low
2. Defective rotor diode
3. Partial short circuit in winding
4. Defective capacitor
1. Engine speed too high
1. Defective rotor diode
2. Electrical load too high
3. Engine not running properly
REMEDY
1. Replace capacitor
2. Check resistance of coils (see Electri-cal Component Specifications, page 15)
3. Replace both diodes on rotor
4. Apply 12-volt battery to capacitor terminals for 2-3 seconds
1. Set engine speed to 3720 RPM (62 Hz)
with no load
2. Replace both diodes on rotor
3. Check resistance of coils (see Electri-cal Component Specifications, page 15)
4. Replace capacitor
1. Set engine speed to 3720 RPM (62 Hz)
with no load
1. Replace both diodes on rotor
2. Do not overload generator
3. Contact an authorized engine service
center
106813
www.desatech.com
15
R
PORTABLE GASOLINE GENERATORS
ELECTRICAL
COMPONENT
SPECIFICATIONS
Resistance in Ohms
StatorStatorRotorRotorCapacitor,
MainAuxiliaryPrimarySecondaryMFDDiodes (2)
ModelWinding * Winding ∆Winding † Winding †450 Volt800 Volt
You may have further questions about installation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-323-5190.
You can also visit DESA International’s
technical service web site at
www.desatech.com.
SERVICING THE
ENGINE
Honda parts and services should be handled
by your nearest authorized engine service
firm. Check the yellow pages of your telephone directory under the listing:
Engines Gasoline, Honda
ACCESSORIES
Heavy-Duty Wheel Kit – PA2020
For Models MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH5000DIE,
MGH6000D, MGH6000DI,
MGH7000D, and MGH7000DI
Wheelbarrow-style wheel kit. Makes generator easy for one person to move.
This kit includes:
• Large 12-inch wheels for easy rolling
• Powder coated tubing and plated hardware for long life
• Long handles with thick grips for greater
comfort and control
Complete installation instructions included.
Automatic Idle Kit – PA2010
For Models MGH4000C,
MGH5000D, MGH6000D, and
MGH7000D
Automatically reduces engine speed when
no power is being used. Reduces fuel consumption and engine noise. Increases engine life.
Complete installation and operation instructions included.
REPLACEMENT
PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If
they cannot supply original replacement
part(s), either contact your nearest Parts
Central or call DESA International’s Technical Service Department at 1-800-323-5190.
When calling DESA International, have
ready
• your name
• your address
• model number of your generator
• how generator is malfunctioning
• purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product.
If they cannot supply original replacement
part(s), either contact your nearest Parts
Central or call DESA International’s Parts
Department at 1-800-972-7879 for referral
information.
When calling DESA International, have
ready
• model number of your generator
• the replacement part number
PARTS CENTRALS
These Parts Centrals are privately owned
businesses. They have agreed to support our
customer’s needs by providing original replacement parts and accessories.
5223 18th Street SW
Lynwood, WA 98037-4506
425-743-9533
1-800-735-1268
Fax: 425-742-0218
www.tucoheat.com
106813
19
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
For Models HWI3000, MGH3000,
and MGH3000PR Alternator
Assembly
This list contains replaceable parts used in
your generator. When ordering parts, follow the instructions listed under Replace-ment Parts on page 19 of this manual.
099866-03Safety Information Decal1
099866-04Safety Information Decal1
099867-02Operation Decal1
† Includes fastening hardware.* Includes reference numbers 1 through 22.
** Parts not available. Included in alternator assembly.
20
106813
OWNER’S MANUAL
ILLUSTRATED
PARTS LIST
For Models MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH5000DIE,
MGH6000D, MGH6000DI,
MGH7000D, and MGH7000DI
Alternator Assembly
This list contains replaceable parts used
in your generator. When ordering parts,
follow the instructions listed under Re-placement Parts on page 19 of this
manual.
* Part not available by itself. Must purchase Alternator Assembly.
**Available at your local hardware store.
106813
10
12
4
17
3
21
9
15
20
19
14
13
16
11
18
23
25
24
22
21
R
PORTABLE GASOLINE GENERATORS
19
ILLUSTRATED
PARTS LIST
For Model MGH10000A
Alternator Assembly
This list contains replaceable parts used in
your generator. When ordering parts, follow
the instructions listed under ReplacementParts on page 19 of this manual.
* Part not available by itself. Must purchase Alternator Assembly.
** Standard hardware item available from local hardware store.
QTY.
22
106813
ILLUSTRATED
OWNER’S MANUAL
PARTS LIST
For Models HWI3000, MGH3000,
and MGH3000PR Roll Cage
This list contains replaceable parts used in
your generator. When ordering parts, follow
the instructions listed under ReplacementParts on page 19 of this manual.
1
3
4
2
5
8
5
4
3
3
4
6
4
3
3
7
4
6
3
3
3
4
5
9
4
7
3
106813
KEYPART
NO.NUMBERDESCRIPTIONQTY.
1105155-01Roll Cage1
2099754-01Engine Spreader1
3NEC-5CLock Nut, 5/16-189
4WP-5CFlat Washer, 5/16"7
5099853-02Shock Mount3
604110002Screw, 5/16-18 x 11/22
714138000Ground Strap1
821834000Washer, 5/16" x 11/2"1
9100406-01Bolt, 5/16-18 x 3/4"1
23
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
For Models MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH5000DIE,
MGH6000D, MGH6000DI,
MGH7000D, and MGH7000DI
Fuel Tank and Roll Cage
11
16
13
16
11
5
15
26
25
11
17
16
16
23
16
17
11
16
13
9
20
18
16
11
19
21
11
13
16
11
10
12
3
2
27
6
7
7
6
8
22
14
23
23
14
10
28
24
29
FUEL
F
24
1
10
4
24
FUEL
F
1
2
10
24
29
24
24
28
9
106813
OWNER’S MANUAL
ILLUSTRATED
This list contains replaceable parts used in your generator. When ordering parts, follow the
instructions listed under Replacement Parts on page 19 of this manual.
PARTS LIST
For Models MGH4000C, MGH4000CI, MGH5000D, MGH5000DI,
MGH5000DIE, MGH6000D, MGH6000DI, MGH7000D, and MGH7000DI
Fuel Tank and Roll Cage
03175000031750000317500003175000Fuel Line Grommet3
* Only on MGH5000DIE electric start models
106813
PARTS AVAILABLE - NOT SHOWN
Safety Information Decal
25
1
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
For Model MGH10000A Fuel
Tank and Roll Cage
33
24
22
10
35
9
9
23
37
10
25
36
10
30
31
32
10
37
9
28
29
26
36
2
37
10
25
20
21
19
20
18
19
21
10
18
10
13
27
37
12
10
9
16
17
15
FUEL
F
14
3
10
9
34
1
10
4
8
12
11
9
6
5
6
7
26
106813
OWNER’S MANUAL
ILLUSTRATED
PARTS LIST
For Model MGH10000A
Fuel Tank and Roll Cage
This list contains replaceable parts used in
your generator. When ordering parts, follow the instructions listed under Replace-ment Parts on page 19 of this manual.
099866-05Safety Information Decal1
100003-04Operation Decal1
099873-01Battery Cable (Positive, Red)1
099873-05Battery Cable (Negative, Black)1
HC4-6CScrew, 1/4-20 x .75"2
DESCRIPTIONQTY.
106813
27
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
For Models MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH5000DIE,
MGH6000D, MGH6000DI,
MGH7000D, and MGH7000DI
Control Panel
This list contains replaceable parts used in
your generator. When ordering parts, follow the instructions listed under Replace-ment Parts on page 19 of this manual.
* Includes fastening hardware
∆ Not shown
† Includes reference numbers 1 through 13
1
1
28
106813
ILLUSTRATED
PARTS LIST
For Model MGH10000A Control
Panel
This list contains replaceable parts used in
your generator. When ordering parts, follow the instructions listed under Replace-ment Parts on page 19 of this manual.
† Includes reference numbers 1 through 16
∆ Not shown
29
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
For Solenoid and Control Board
Assemblies and Mounting
12
10
13
6
14
7
8
10
11
9
8
Solenoid Assembly and Mounting
3
DESA INTERNATIONAL
S2
S1
L1
L2
2
1
Control Board Assembly and Mounting
5
4
30
106813
ILLUSTRATED
PARTS LIST
For Solenoid and Control Board
Assemblies and Mounting
This list contains replaceable parts used in
your generator. When ordering parts, follow the instructions listed under Replace-ment Parts on page 19 of this manual.
KEYPART
NO.
1100105-01Control Board Assembly1
226499000Hex Head Screw, 10-32 x 3/4"4
3100321-01Nylon Spacer4
4WP-C3Flat Washer, #104
526514000Lock Nut, 10-324
6100324-03Solenoid Assembly (Includes
* Model MGH10000A Only
† All Models Except MGH10000A
NUMBER
100755-01Linkage Rod1
100756-01Solenoid Mounting Bracket1
100320-01Yellow Wire1
100322-01White Wire (with 2 Flags)1
100322-02White Wire (with 1 Flag and 1 Spade)1
100366-01Rocker Switch1
100334-01Auto-Idle Decal1
OWNER’S MANUAL
DESCRIPTIONQTY.
Plunger, Nut, and Lock Washer)1
†
†
†
PARTS AVAILABLE NOT SHOWN
1
1
1
106813
31
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard
written warranty. We make no other warranty, expressed or implied.
Note:
The two-year limited warranty below covers all non-engine parts of this generator including the alternator. Honda
warrants the engine. See engine owner’s manual for engine warranty information.
TWO-YEAR LIMITED WARRANTY
GASOLINE PORTABLE GENERATORS
DESA International warrants each alternator, generator, or electric product of its manufacture, to be free from defects
in material and workmanship for two years from the date of first purchase from an authorized dealer, provided that the
product has been properly installed, maintained, and operated in accordance with all applicable instructions. The bill
of sale or proof of purchase must be presented at the time a claim is made under this warranty.
This warranty is extended only to the original retail purchaser. This warranty covers only the parts and labor required
to restore this unit to its proper operating condition. Warranty parts must be obtained through factory authorized
dealers and service centers for this product. These dealers and service centers will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that
fail or become damaged as a result of misuse, abuse, negligence, accident, lack of proper maintenance, alteration,
modification, tampering, contaminated fuels, repair using improper parts, or repair by anyone other than an authorized
dealer or service center. Routine maintenance is the responsibility of the owner. Travel, handling, transportation, and
incidental costs associated with warranty repairs are not reimbursable under this warranty and are the responsibility of
the owner.
DESA International makes no warranty with respect to the engine and engine components not of its manufacture.
They are subject to warranties of their manufacturers.
To the full extent allowed by the law of the jurisdiction that governs the sale of the product, this express warranty
excludes any and all other expressed warranties and limits the duration of any and all implied warranties, including
warranties of merchantability and fitness for a particular purpose to two years from the date of first purchase, and
DESA International’s liability is hereby limited to the purchase price of the product and DESA International shall not
be liable for any other damages whatsoever including indirect, incidental, or consequential damages.
Some states do not allow limitation of how long an implied warranty lasts or an exclusion or limitation of incidental
or consequential damages, so the above limitation of damages may not apply to you.
This warranty provides the original purchaser with specific rights. For information regarding those rights, please
consult the applicable state laws.
106813 01
NOT A UPC
INTERNATIONAL
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com
106813-01
REV. B
03/00
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.