MasterCraft 058-8386-8 Instruction Manual

AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8
INSTRUCTION MANUAL
AIR COMPRESSOR 11-GALLON (41.6 L)
058-8386-8
If any parts are missing or damaged, or if you have any questions, please call our toll-free helpline at 1-800-689-9928.
Read and understand this instruction manual thoroughly before using the product. It contains important information for your safety as well as operating and maintenance advice.
Keep this instruction manual for future use. Should this product be passed on to a third party, this instruction manual must be included.
An English version of this manual is available online at:
www.canadiantire.ca/manuals
中文版說明書請參照:
www.canadiantire.ca/manuals
Quick Start Guide
Version: 03
058-8386-8-Mastercraft-11G-3HP-Air-Compressor-EN-08.indd 1-2 7/4/12 11:26 AM
VY03A1863303
OFF
2
AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8
STEP 1
Set the pressure switch to the
OFF position.
STEP 2
Turn the air pressure regulator knob counter-clockwise until it stops.
STEP 3
Attach hose and accessories (not provided).
Apply plumber's tape on all the threads to prevent air leakage.
STEP 5
Plug in the power cord.
Caution: Connect the power cord only after break-in process has been competed, otherwise motor might get damaged (see Breaking-in the
pump, page 14).
STEP 4
Close the tank drain valve, located on the bottom of the air tank.
TABLE OF CONTENTS
QUICK START GUIDE
TECHNICAL SPECIFICATIONS 3
SAFETY GUIDELINES 4 – 6
KEY PARTS DIAGRAM 7
KEY PARTS LIST 8 – 9
INTENDED USE 10 – 11
ASSEMBLY 12 – 13
OPERATING INSTRUCTIONS 14 – 17
MAINTENANCE 18 – 19
TROUBLESHOOTING 20 – 21
EXPLODED VIEW 22
PARTS LIST 23
WARRANTY 24 – 25
STEP 6
Set the pressure switch to the ON position. Turn the air pressure regulator knob clockwise until desired pressure is reached.
QUICK START GUIDE
CLOSE
CLOSE
OPEN
058-8386-8-Mastercraft-11G-3HP-Air-Compressor-EN-08.indd 3-2 7/4/12 11:26 AM
3 4
AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8
TECHNICAL SPECIFICATIONS
PRODUCT NUMBER 058-8386-8
HORSEPOWER 3
TANK SIZE 11 U.S. GALLONS (41.6 L)
AIR DELIVERY (SCFM*) @ 40 PSI 6.2
AIR DELIVERY (SCFM*) @ 90 PSI 5.2
CUT-IN PRESSURE (PSI) 105
CUT-OUT PRESSURE (PSI) 135
PUMP DESIGN OIL-LESS
MOTOR INDUCTION
POWER 120 V, 60 Hz, 15 A
WEIGHT 66 lb 1 oz (30 kg)
POWER CORD SJT 14 AWG / 72" (1.83 m)
EXTENSION CORD SJT 12 AWG / MAXIMUM 30’ (9.1 m)
* SCFM: Standard Cubic Feet per Minute (= The volumetric flow rate of a gas
corrected to standardized conditions of temperature and pressure.)
This manual contains information that relates to PROTECTING PERSONAL SAFETY and PREVENTING EQUIPMENT PROBLEMS. It
is very important to read this manual carefully and understand it thoroughly before using the product. The symbols listed below are used to indicate this information.
DANGER!
Potential hazard that will result in serious injury or loss of life.
WARNING! Potential hazard that could result in serious injury or loss of life.
CAUTION!
Potential hazard that may result in moderate injury or damage to equipment.
IMPORTANT! Installation, operation or maintenance informa tion that is important but
not hazard related.
Safety Advice
DANGER!
1. RISK OF FIRE OR EXPLOSION. Do not spray a flammable or combustible liquid or
paint near sparks, flames, pilot lights or in a confined area. The spray area must be
well-ventilated. Keep compressor at least 20’ (6 m) away from spray area. Do not carry and operate the compressor or any other electrical device near the spray area. Never smoke when spraying. Use a minimum of 25’ (7.6 m) of hose to connect a spray gun to the compressor.
2.
RISK OF ELECTRIC SHOCK. Do not expose to rain. Store indoors. Hazardous voltage.
Disconnect from power source before servicing. Compressor must be grounded. Do
not use grounding adaptors.
3.
RISK OF BURSTING. Make sure the regulator is adjusted so that the compressor outlet
pressure is set lower than the maximum operating pressure of the spray gun or tool.
Before starting the compressor, pull the ring on the safety valve to make sure the valve
moves freely (see diagram on page 17). Drain water from tank after each use. Do not
weld or repair tank.
SAFETY GUIDELINES
058-8386-8-Mastercraft-11G-3HP-Air-Compressor-EN-08.indd 3-4 7/4/12 11:26 AM
5 6
AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8
SAFETY GUIDELINES
4. RISK OF PERSONAL INJURY. Never spray compressed air or ma terial at self or others.
5. RISK OF BURSTING. Check the maximum pressure rating in the manual or
identification label. The compressor outlet pressure must be regulated so that it does not exceed the maximum pressure rating. Relieve all pressure in the hose before removing or attaching accessories.
6.
RISK OF BURSTING. Do not adjust the pressure switch or safety valve for any reason. They have been preset at the factory for this compressor’s maximum pressure. Tampering with the pressure switch or the safety valve may cause personal injury or property damage.
7.
RISK OF BURNS. The pump and the manifold generate high temperatures. In order to avoid burns or other injuries, do not touch the pump, the manifold or the transfer tube while the compressor is running. Allow the parts to cool down before handling or servicing. Keep children away from the compressor at all times.
8.
RISK TO BREATHING. Be certain to read all labels when you are spraying paints or toxic materials, and follow all safety instructions. Use a respirator mask if there is a chance of inhaling anything you are spraying. Also, NEVER directly inhale the air produced by a compressor.
9. RISK OF EYE INJURY. Wear ANSI Z87.1 approved safety goggles when using an air
compressor. Do not point any nozzle or sprayer toward a person or any part of the body. Serious injury may occur if the spray penetrates the skin.
WARNING!
1. Pull the pressure safety valve ring every day in order to ensure that
the valve is functioning properly.
2. The compressor must be located in a well-ventilated area for cooling, and must be a minimum of 12” (31 cm) away from the nearest wall.
3. Protect the air hose and the power cord from damage and puncture. Inspect them for weak or worn spots every week, and replace them if necessary.
4. Always wear hearing protection when using an air compressor. Failure to do so may result in hearing loss.
5. Do not carry the compressor while it is running.
SAFETY GUIDELINES
6. Do not operate the compressor if it is not in a stable position.
7. Do not operate the compressor on a rooftop or an elevated position that could allow the unit to fall
or be tipped over.
8. Always replace a damaged gauge before operating the unit again.
Extension cords
As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drip in voltage, resulting in loss of power and possible product damage. Refer to the table here to determine the required minimum wire size.
Recommended Minimum Wire Gauge for Extension Cords* (120 V)
AMPERE
RATING
CORD SIZE IN AWG (AMERICAN WIRE GAUGE)
Extension cord length in feet
25' 50' 75' 100' 150' 200'
0 - 5 16 16 16 14 12 12
5.1- 8 16 16 14 12 10 --
8.1 - 12 14 14 12 10 -- --
12.1 - 15 12 12 10 10 -- --
15.1 - 20 10 10 10 -- -- --
* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.
The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14-gauge cord can carry a higher current than a 16-gauge cord. When using more than one extension cord to make up the total length, be sure each cord contains at least the minimum wire size required.
Guidelines for using extension cords
your
are
your
If you using an extension cord outdoors, be sure it is marked with the
"W-A" ("W" in
Canada) to indicate it is acceptable for outdoor use.
Ensure extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified technician before using it.
Protect extension cords from sharp objects, excess heat and damp or wet areas.
058-8386-8-Mastercraft-11G-3HP-Air-Compressor-EN-08.indd 5-6 7/4/12 11:26 AM
7 8
AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8
A. ELECTRIC MOTOR: The motor is used to power the pump. It is equipped with at thermal overload
protector. If the motor overheats for any reason, the thermal overload protector will shut it do wn in order to prevent the motor from being damaged.
B. AIR COMPRESSOR PUMP: The pump compresses the air and discharges it into the tank via the
piston that moves up and down in the cylinder.
C. PRESSURE SWITCH: This switch turns the compressor on and off. It is operated manually and
when it is in the ON position, it allows the motor to start if the pressure in the air tank is below the factory set cut-in pressure, and allows the motor to stop if the pressure in the air tank reaches the factory set cut-out pressure. Be sure to set this switch to the OFF position when the compressor is not being used and before unplugging the compressor.
D. SAFETY VALVE: This valve is used to prevent system failure by draining pressure from the system
when it reaches a preset level if the pressure switch has not shut down the motor. It will pop open automatically, or it can be activated manually by pulling the ring on the valve.
E. AIR PRESSURE REGULATOR: The regulator is used to adjust the pressure inside the line to the
tool that is being used. Turn the knob clockwise to increase the pressure and counter-clockwise to decrease the pressure.
[
WARNING! Do not exceed the tool’s maximum working pressure.
F. T ANK PRESSURE GAUGE: The gauge measures the pressure level of the air that is stored in the
tank. It cannot be adjusted by the operator and it does not indicate the pressure inside the line.
G. OUTLET PRESSURE GAUGE: The gauge measures the regulated outlet pressure.
H. AIR OUTLET: The outlet is connected to the 1/4” (6.4 mm) NPT air hose.
I. AIR TANK DRAIN VALVE: The drain valve is used to remove moisture from the air tank after the
compressor is shut off.
[
WARNING! Do not attempt to open the drain valve when there is more than
10 PSI of air pressure in the tank.
KEY PARTS DIAGRAM
KEY PARTS LIST
AIR TANK DRAIN VALVE (I)
ELECTRIC MOTOR (A)
AIR COM PRESSOR PUMP (B)
PRESSURE SWITCH (C)
AIR PRESSURE REGULATOR (E)
SAFETY VALVE (D)
OUTLET PRESSURE GAUGE (G)
TANK PRESSURE GAUGE (F)
AIR OUTLET (H)
POWER CORD (K)
AIR TANK (J)
058-8386-8-Mastercraft-11G-3HP-Air-Compressor-EN-08.indd 7-8 7/4/12 11:26 AM