2. Electrical connections should be done by a qualifi ed electrician,
so that all electrical wiring will conform to your local codes.
3. Always turn OFF POWER and UNPLUG motor and pump inside
the cooler before installing or performing any maintenance.
4. Your cooler will run on either 120V or 240V A.C., single phase,
60 Hz (cycle) current.
5. Motor and pump have a grounded, molded plug and an automatic
thermal overload switch which will shut motor off when it
overheats. The motor will restart automatically when it cools
down.
WARNING: To reduce the risk of fi re or electric shock, do not use
this fan with any “solid-state fan speed control device.”
ADA51
ASA51
AUA51
Serial Number:
Número de série:
ADA5112
ASA5112
AUA5112
ADA71
ASA71
AUA71
READ AND SAVE THESE INSTRUCTIONS
ADA7112
ASA7112
AUA7112
HOW EVAPORATIVE COOLERS WORK
Evaporative cooling is nature’s way of cooling. When air is
moved over a wet surface, water is evaporated and heat is
absorbed. When stepping out of swimming pool with the
wind blowing, evaporative cooling makes you feel cool, even
though the air may be warm.
This unit works on the same principle. Air is drawn across
wet fi lter pads where the air is cooled by evaporation and then
circulated throughout the building. It is this combination of
cooled air and the movement of air over the skin which makes
it feel cool.
Unlike refrigeration systems which recirculate the air, an
evaporative cooler continually brings in fresh air while
exhausting old air. You are completely replacing the air every
2 to 4 minutes by opening windows or doors, by using Up-
®
ceiling vents, or a combination of both. The air is always
Dux
fresh, not stale, laden with smoke and odors as happens with
refrigerated air conditioning.
PN 110498-2 REV. 3-15
INSTALLATION
CAUTIONS:
Before installing the cooler, note the following items:
• Before installation, ensure your existing electrical system is rated for the additional amperage draw from unit.
• Installation inside attic areas is NOT recommended.
• If installing unit on ground, ensure surface area is level, well packed and will not erode or become unstable with water
erosion.
• If installing on brace, or existing construction, ensure structure will hold the operating weight of the cooler. (See specifi cation
table for operating weight.)
• Ensure entire unit is suffi ciently supported. If supporting the unit with legs at each corner, the middle of the unit where the two
sections join must be supported as well.
• We strongly recommend consulting a professional contractor if installation will require cutting through existing structure such
as walls or roof.
• Do not screw or drill within 5 inches of the bottom of the wet section as you could puncture the reservoir.
• Ensure all electrical work is accomplished to local standards. An electrician may be needed for correct and safe wiring.
WARNING: Disconnect all electrical service that will be used for this unit before beginning the installation
and DO NOT reconnect until installation is complete.
PARTS AND TOOLS NEEDED:
• Motor with Motor Pulley (purchased separately)
• 5/32 Allen Wrench (for pulley installation)
• 7/16 Wrench or Crescent Wrench
• Phillips Screwdriver
• Sill cock or water valve and tubing
• Multimeter (for amp reading)
SEPARATING SECTIONS
Follow the steps below to separate the sections of the unit, if desired for ease of
installation.
1. Remove four bolts (two on each side) from the inside center post of the unit
connecting the wet section to the blower section.
2. On a few models, two bolts on the interior of the unit attaching the bottom
pans of the two sections will need to be removed as well.
MOTOR INSTALLATION
Note: Motor must be purchased separately. See Motor Specifi cation Table for
motors that can be used.
1. For typical 120V installation, install motor cord (provided) to motor
(purchased separately). Follow motor electrical diagram using the following
color code:
BLACK - HIGH; RED - LOW; WHITE- COMMON; GREEN - GROUND
2. When installing a 1 hp motor, reverse the adjustable yolk to accommodate
the larger motor. Adjust the cradle spacing as needed for size of motor.
Mount the blower motor onto the yokes of the motor mount. Fasten with
provided motor clips.
3. Leave motor cord unplugged until electrical portion of installation is
complete.
PULLEY INSTALLATION
1. Open adjustable pulley about 5 full turns to the least diameter.
2. Install the motor pulley onto the motor shaft so that it aligns with the blower
drive pulley and tighten with Allen wrench.
3. Loosen adjustment screw on motor mount.
4. Install belt onto pulleys.
5. Rotate motor mount until belt is tight, then tighten adjustment screw to
secure belt. Check belt tension per instructions on page 5.
Note: Further adjustment to belt and pulley may be required after installation is
complete.
Remove
Two Bolts
(Each Side)
Connecting
Wet And
Blower
Sections
Motor
Pulley
Adjustable
Motor Mount
Adjustment Screw
Remove Two Bolts
Connecting Bottom Pans
Motor
ALIGN PULLEYS
Motor
Motor
Pulley
Belt
Blower
Pulley
Motor
Clips
Adjustable
Yoke
2
110498-2
ELECTRICAL CONNECTION
Blue/Black
White
Brown
Orange
Green
Green
Orange
White
Red
Black
PUMP
HIGH
LOW
COMMON
GROUND
= WIRE NUT
HIGH
LOW
COMMON
GROUND
Black
Green
White
Red
BLOWER MOTOR
PUMP
MOTOR
TO SWITCH
COMMON
PUMP
MOTOR
BLOWER MOTOR
Red
Orange
Green
Black
GROUND
COMMON
LOW
HIGH
= WIRE NUT
GROUND
LOW
HIGH
PUMP
Black
Red
White
Orange
Green
Green
Orange
Brown
White
Blue/Black
TO SWITCH
WARNING: Electrical connections should be accomplished by a qualifi ed electrician to ensure all electrical
wiring conforms to local standards.
WARNING: Follow all safety precautions when working with electrical power.
WARNING: Before proceeding with installation, ensure electrical power is disconnected until installation is
complete.
Note: This unit can be controlled with a manual 6 position switch found at a local hardware store, or with a thermostat such as
Champion’s Masterstat
®
Wall Control Thermostat model #110423-2. For thermostat installation refer to its operating manual.
Follow the steps below for manual switch installation:
1. Determine location on internal wall for 6 position switch.
2. Supply 120V or 240V power to switch, depending on motor and pump
voltages.
3. Remove screws securing junction box to cooler cabinet.
4. Bring four conductors plus a ground from switch to cooler junction box
(such as two 2-wire Romex
CAUTION: Make sure to use correctly sized wire and follow all
®
wire)
Junction Box
Motor And Pump
Receptacles
Remove Screws to Access
Wiring Connections
local electrical codes.
5. Connect the four conductor wires to the leads of the motor and pump
receptacles located in the junction box. Follow the connection diagrams
below for 120V or 240V installations.
6. Reinstall junction box to cooler cabinet.
7. Plug motor and pump plugs into receptacles.
8. Follow switch electrical instructions for connecting the four conductors and
power leads to switch.
Warning: Pump cord must be secured in retaining clip to
prevent contact with water.
120 VOLT
240 VOLT
110498-2
3
NOTE: If single speed
motor is used, do not
use the RED electrical
leads from the motor or
receptacle. Tape off both
RED leads.
CAUTION: Receptacles in junction box are
only for Motor and pump.
Do not plug anything
else into receptacle.
WARNING: Ensure
cooler cabinet is properly grounded to a suitable
ground connection for
maximum safety and
protection of equipment.
WATER CONNECTION
Note: Do not connect the water supply to any soft water applications.
Faucet
Water Shut
Off Valve
SILLCOCK INSTALLATION
A steady water supply is required for the operation of this cooler. If water
source comes from an external water faucet, a sillcock and shutoff valve
will need to be purchased and installed.
1. Install sillcock and water valve on faucet.
2. Run ¼” plastic or copper tubing from the faucet to the unit.
3. Install one end of tubing to water valve by placing nut and ferrule on
Sillcock With Std.
Hose Connection
tubing and tightening the nut until water tight.
FLOAT VALVE INSTALLATION (Refer to illustration)
1. Remove items 1, 2, 3, and 4 from fl oat.
2. Insert fl oat body through hole in media shield and back post panel as
shown.
3. Install washer (1) and nut (2). Tighten to keep fl oat from turning. Place
nut (4) and ferrule (3) on water supply line. Connect to fl oat fi tting and
tighten until water tight.
4. Slide fl oat shield over fl oat body until it snaps into place.
Note: After installation is complete and water is turned on, the fl oat level will
need to be adjusted.
5. Bend rod to adjust fl oat. Water level should be about 1 inch below the
top opening of the overfl ow pipe.
OVERFLOW INSTALLATION
1. Remove nut and place nipple through the hole in the pan with the rubber washer
between the pan and the head of the drain nipple.
2. Screw nut onto nipple and draw up tight against bottom pan.
3. Screw overfl ow pipe into nipple. This overfl ow pipe may be removed to drain pan
when necessary.
Note: A garden hose may be screwed onto the drain nipple to drain water away from the
unit.
SCALE BUILDUP PREVENTION
As water evaporates, minerals that were in the water will remain. Over time this
accumulation of minerals will cause scaling on the pads and in the reservoir. We
recommend the installation of either a bleed-off kit (included in unit) or a purge pump
(purchased separately) to help prevent scale build up and increase the life of the
unit. A purge pump will drain the pan every few hours of pump operation, to keep
fresh water in the unit. A bleed-off kit will continually bleed off a small portion of
water while the pump is running allowing fresh water to continually replace the old
stagnate water. Follow the instructions below for installing the bleed-off kit.
1. Cut the pump hose and insert the barbed ends of the bleeder tee into each cut
end.
2. Insert one end of the bleeder tubing onto the bleeder tee and run the other end
out of the cooler through the overfl ow pipe.
Note: A restrictor clamp is provided which, if desired, may be installed onto the
bleeder tubing to restrict the amount of water being bleed off. The amount of water
to bleed off depends on the quality of the water in your area. Start with 1-2 gal/hr
and increase if needed.
Float
Pump Hose
Ferrule
Nut
Float
Shield
Overfl ow Pipe
Nipple
Rubber Washer
Reservoir
Nut
BLEED-OFF KIT
Bleeder Tee
Copper Or
Plastic Line
To Cooler
Back Post
Panel
2
1
Bleed Tube
Restrictor
Overfl ow Pipe
4
3
AMPERAGE DRAW AND BELT TENSION
CAUTION: No attempt should be made to completely install this unit without the aid of an electrician or
someone familiar with testing amperage draw. Failure to comply with these instructions may void your
warranty.
This unit is equipped with an adjustable motor drive pulley for adjusting the blower wheel speed to the proper loading for different
duct systems. It is important that the motor drive pulley is adjusted to correct size to ensure maximum air delivery without damage
to the motor. Be sure to follow these instructions carefully.
4
110498-2
AMPERAGE DRAW AND BELT TENSION (CONT)
1. Ensure electrical connection of unit is complete and in accordance with
all safety standards and local requirements.
2. Reinstall inspection panels. Apply power, turn water and pump on and
allow cooler to run for a few minutes to wet pads.
3. Check amperage and verify it conforms to amperage listed on the
specifi cation label on motor.
• If amperage draw is less than motor rating, turn off electrical power
and remove inspection panels. Unplug motor inside cooler, this will
protect you from someone turning on unit while you are working
inside. This should be done for your safety. Adjust pulley to a larger
diameter and readjust belt tension. Plug motor in,
install inspection panels, and retest amperage draw.
Repeat this process until correct amperage draw is
attained.
Note: Increasing motor pulley diameter increases
amperage draw. Decreasing motor pulley diameter
decreases amperage draw.
CAUTION: DO NOT operate cooler with larger
amperage draw than specifi ed on motor plate. Motor
damage will occur.
4. Check belt tension after adjusting pulley. A 3 lb. force
should defl ect the belt 3/4 inches. Readjust belt if
needed by loosening adjustment screw, rotate motor
until you have the correct belt tension, then re-tighten
screw.
Motor
BELT TENSION
3 Lb. Pressure
3/4 Inches
Motor
Pulley
Belt
Blower
Pulley
Decrease
Amperage
Adjustment
Screw
OPERATION
NOTES: These coolers may be used without water for ventilation purposes. When outside air is cool (for example, at night)
or when humidity is high the water pump can be turned off.
To eliminate the delivery of hot air when starting the cooler, start the pump only for the fi rst few minutes, then turn on the
blower motor.
For an evaporative cooler to be effective, there needs to be adequate exhaust. If there is not adequate exhaust, pressure and
humidity will build up in the building. You exhaust by opening doors or windows to allow the old stale air in the building to escape.
Attic exhaust dampers may also be installed to exhaust the air into the attic. The combination of attic exhaust dampers and a
thermostat can provide a completely automatic operation.
An often misunderstood concept of evaporative cooling is the amount of air that should be exhausted. How much should you open
your windows? The following two methods will help you determine the amount to open your windows.
WINDOW AREA/CFM METHOD
For proper air fl ow, allow an opening of at least 2 square feet (288 square inches) for each 1000 CFM rating of your unit. Example: At 3320 CFM, model ADA 51 (1/2 hp) requires 6.6 square feet (950 square inches) of opening (3320/1000 * 2 =
6.6).
Multiply the number of windows by window width in inches and divide this into the number of square inches required for your size
unit. This will give you the height to open windows. In this example, four 36 inch wide windows should be opened 6.6 inches each.
TISSUE SUCTION METHOD
1. Take a piece of tissue paper and cut it lengthwise into 3 equal strips.
2. Turn your cooler on high cool.
3. Open one window at least six inches wide in each room that you want to cool.
4. Take the piece of tissue paper and put it up against the screen of the open window furthest from the cooler discharge
opening. Let go of it. It will do one of three things.
IF: It falls down. THEN: CLOSE all of the windows one inch and try step 4 again.
IF: It plasters itself to the screen. THEN: OPEN all of the windows one inch and try step 4 again.
IF: It stays on the screen lightly. THEN: PERFECT. You are done. Enjoy your cooler.
Notes:
• When switching to low cool, you must re-balance your home. Repeat step 4.
• Once you balance your home you can cool some areas more than others by opening those windows
more and closing the others by the same amount. Repeat step 4 to make sure your home is still air balanced.
110498-2
5
MAINTENANCE
Regular maintenance on your cooler will increase performance and extend the life of your cooler.
WARNING: Before accomplishing any maintenance ensure power is turned off and the motor and pump are
unplugged.
START OF SEASON MAINTENANCE
Accomplish these basic steps before the temperatures require cooling in case you have to acquire replacement parts.
CLEAN MEDIA
1. With power OFF, remove inspection panels, top panels and inlet grille to access
interior of unit. Place panels in a fl at, secure place to protect them from being
bent or damaged.
2. Disconnect water tube and lift off water distribution tray, accessing the media.
Remove fi lter pad on top.
3. Remove and inspect media pads. Using a garden hose sprayer, wash the media
pad ensuring openings are clear of obstruction and dirt. Some light scrubbing
may be required to remove mineral deposits. Do not use harsh detergents or
pressure washers in cleaning. Make every effort to keep the media intact.
4. The original media has a standard life of 5 years, but in areas with very high
mineral content the media may have to be replaced sooner.
5. When reinstalling existing or installing new replacement pads, ensure pads are installed in the correct confi guration:
• Place the media into the unit with the steeper fl ute angle sloping down towards the air inlet side. This provides the most effective
water fl ow to the pads, allowing higher cooling effi ciencies.
• We recommend using original equipment, MasterCool® media replacement pads for highest cooling capabilites.
NOTE: If competitor pads with equal angles are installed, disregard directional placement of media.
OIL BEARINGS
1. The blower bearings should be oiled each year with non-detergent 20/30 weight oil.
2. Locate and open the oil cup on each of the blower bearings and add a few drops of oil.
3. Add oil to motor bearings if motor has oil lines. Note: Many motors are sealed and do not
require addition of oil.
CAUTION: Do not over oil the motor, as this can cause the motor to burn out due to
excessive oil on windings.
Air Enters
Air Exits
15°
Blower Bearing
Oil Cup
45°
CLEAN PUMP
1. Pump should be cleaned at least once a year or more often if debris accumulates.
2. Unplug motor and pump from junction box, and disconnect water tube, if not already accomplished.
3. Using a screw driver, pry plastic retaining fastners straight up out of the pump-mounting bracket.
4. Slide the pump off the mounting bracket.
5. Extract pump from straining basket or netting and remove base of pump.
6. Clean pump, turn impeller to ensure free movement.
7. Remove pump spout and check for blockage.
8. Reinstall pump base and verify it is secure.
9. Before reinstalling pump, check water hose, bleeder line and water distributor tube to
ensure there is no blockage in any lines.
10. Reinstall the pump by sliding pump onto mounting bracket and reinserting the plastic
retainers to ensure pump stays in upright postion.
11. Reinstall water tube to the pump outlet spout.
CHECK BELT
1. Before unit is turned on, check that belt condition is good. If belt must be replaced, install
same sized belt.
2. Verify belt tension is correct: 3/4” defl ection with 3 lbs of force.
Remove
Base
Impeller
END OF SEASON SHUTDOWN
The cooler should be prepared before any extended period of non use, and especially before winter shutdown.
1. Drain all water from unit, supply line and pump to ensure no damage occurs from freezing. Keep water line disconnected from both
unit and supply line.
2. Unplug motor and pump from junction box.
3. Clean unit.
4. Cover unit to protect fi nish for long periods of non use.
Musty or unpleasant odor1. Stale or stagnate water in cooler1. Drain pan and clean pads
1. Low voltage1. Check voltage
2. Excessive belt tension2. Adjust belt tension
Motor cycles on and off
Blower shaft and tight or locked
3.
3. Unplug unit and oil or replace bearings
4. Bearings dry4. Oil bearings
5.
Motor pulley diameter too large ,
causing motor overload
5. Adjust pulley so full load ampere
rating of motor is not exceeded.
1. Bearings dry1. Oil bearings
Noisy
2. Wheel rubbing blower housing2. Unplug unit, inspect and realign
3. Loose parts3. Tighten loose parts
1. Inadequate exhaust in house
1. Open windows or doors to increase air fl ow
2. Pads not wet2. Check water distribution system
Inadequate cooling
• Pads clogged
• Distribution tube holes clogged
• Pump not working properly
• Clean pads
• Clean tube holes
• Unplug and replace or clean pump
Excessive humidity in house1. Insuffi cent air exhaust1. Open doors or windows
110498-2
7
MASTERCOOL SINGLE INLET
LIMITED WARRANTY POLICY
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS.
This warranty is extended only to the original purchaser of this evaporative cooler when the unit is installed and used under
normal conditions against defects in workmanship and materials as follows:
• One (1) year from date of sale on the cabinet components
• Five (5) years on the evaporative media, which is considered a disposable component
and should be replaced periodically.
• Two (2) years on the motor, if furnished by Champion Cooler
The manufacturer will replace the defective part/product, at its discretion. It is agreed that such replacement is the
exclusive remedy available from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW,
THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND
CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
Exclusions from this warranty
We are not responsible for any incidental or consequential damage from any malfunction, accident, misuse, alterations,
unauthorized repairs, abuse, including failure to perform reasonable maintenance, normal wear and tear.
Alterations include the substitution of name brand components including, but not limited to media pads.
We are not responsible for any damage from the use of water softeners or treatments, chemicals or descaling materials.
We are not responsible for the cost of service calls to diagnose the cause of trouble, or labor charge to repair and/or replace
parts.
No employee, agent, dealer or other person is authorized to give any warranties or conditions on behalf of the manufacturer.
The customer shall be responsible for all labor costs incurred.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or
exclusions may not apply to you.
How to obtain service under this warranty
Within the limitations of this warranty, purchaser with inoperative units should contact the dealer where you purchased the
cooler. If for any reason you are not satisfi ed with the response from the dealer, contact Customer Service at 800-643-8341
for instructions on how to obtain service within warranty as listed above.
This warranty gives the customer specifi c legal rights, and you may also have other rights which vary from province to
province, or state to state.
Register your product at www.championcooler.com.
8
110498-2
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.