MasterCool 53100-C, 53518-UV, 53312, 53515 User Manual

User Guide and Parts List
UV LEAK LOCATOR KITS
53312
53100-C
53518-UV
53515
3
DYE INJECTION INSTRUCTIONS
(1)
(2)
(3)
(4)
(4)
(1)
(2)
(3)
(4A)
Disposable
Cartridge Type
Injector (2 oz)
53223
Mini Disposable
Cartridge Type
Injector (1 oz)
53809
(1)
(2B)
Refillable
Cartridge Type
Injector (2 oz)
53123
PLEASE USE CAUTION!!
• When injecting dye into a pressurized system, ALWAYS wear safety glasses and gloves!
• Never breathe refrigerant vapor!
• Never use the UV light without wearing the UV glasses!
• Lamp surfaces will get hot very quickly. DO NOT TOUCH THE LENS!
A. PURGING AIR FROM THE HOSE ASSEMBLY
It is important to eliminate any air in the hose before injecting dye into the A/C system. (This process is necessary only once for the setup).
Purging Disposable Cartridge Type Injector
• Hold the cartridge (2) upward while unscrewing the cap. Snap the hose assembly (3) onto the cartridge, and coupler (4) or (4A) to the hose assembly.
• While holding the assembly upward, attach the handle (1) to
the bottom of the cartridge by turning it clockwise. Continue turning while dye enters the hose and pushes the air up. Use a pen to press the depressor of the coupler (4) to release the air if necessary. Repeat this process as needed until dye appears at the coupler’s end.
Purging Refillable Cartridge Type Injector
• Hold the dye injector (upward while unscrewing the cap/hose assembly (2B). Turn the handle of dye injector (1) counter clockwise all the way before filling. Fill the injector with dye.
Replace cap/hose (2B), tightening securely and attach coupler
(4) to the hose assembly.
• While holding the assembly upward, start turning the handle
(1) clockwise. Continue turning as dye enters the hose and pushes the air up. Use a pen to press the depressor of the coupler (4) to release the air, if necessary. Repeat this process as needed until dye appears at the coupler’s end.
B. INJECTION
1. Turn the A/C system and engine off!!
2. Connect injector to the low side service port of A/C system.
Hold body of injector. Use (I) starting line on handle end as a guide. Turn handle clockwise to inject 1 application of dye. (Approximately 1 to 1 1/4 turn(s) for Concentrated Dye)
Loading...