TECHNICAL
TECHNICAL
GUIDE
GUIDE
95.0% AFUE STANDARD PSC SINGLE
STAGE MULTI-POSITION RESIDENTIAL
GAS FURNACES
MODELS: RGF19*P
NATURAL GAS
40 - 130 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
Additional rating information can be found at
www.ahridirectory.org
A 20-year limited warranty on heat exchangers in residential applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online
within 90 days of purchase for replacement or closing
for new home construction.
See Limited Warranty certificate in Users Information Manual for details.
www.upgnet.com
WARRANTY SUMMARY
810762-UTG-E-1016
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV, National Fuel Gas Code and may
be vented either through side wall or roof applications using
approved plastic combustion air and vent piping. Approved
plastic combustion air and vent piping include Selkirk Polyflue,
Duravent Polypro, & Centrotherm Innoflue polypropylene venting systems.
FEATURES
• Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
• Compact, easy to install, ideal height 33" tall cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy access to controls to connect power/control wiring.
• Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
• Low unit amp requirement for easy replacement application.
• Single wire twinning or staging feature available.
• All models are convertible to use propane (LP) gas.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• 100% shut off main gas valve for extra safety.
• 4 speed, direct drive PSC motor.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary heat exchanger made of corrosion resistant
stainless steel materials.
• Timed on, adjustable off blower capability for maximum
comfort.
• Blower door safety switch.
• Solid removable bottom panel allows easy conversion.
• Airflow leakage less than 1% of nominal airflow at duct performance testing conditions.
• No knockouts to deal with, making installation easier.
• Movable duct connector flanges for application flexibility.
• Quiet inducer operation.
• Inducer rotates for easy conversion of venting options.
• Fully supported blower assembly for easy access and
removal of blower.
• External air filters used for maximum flexibility in meeting
customers IAQ needs.
• Protection included from air intake, exhaust vent, or condensate blockage.
• No special vent termination required.
• 1/4 turn knobs provided for easy door removal.
• Internal condensate trap design (patent pending) provides
condensate management options and is self-priming to
prevent nuisance problems.
• Venting applications - may be installed as either 2-pipe
(sealed combustion) or single-pipe vent (using indoor combustion air).
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

810762-UTG-E-1016
RIGHT SIDE
Combustion Air Inlet
Condensate Drain
(Downflow)
Vent Outlet
23”
Optional Return Air
Cutout (Either side)
24.25”
RETURN END
1.5”
.56”
.56”
Combustion Air Inlet
Condensate Drain
(Downflow)
B
.56”
SUPPLY END
LEFT SIDE
Vent Outlet
28.5”
29.5”
23.8”
Combustion
Air Inlet
20”
FRONT
Gas Pipe
Entry
Electrical
Entry
Condensate
Drain
Thermostat
Wiring
A
3”
Vent
Outlet
C
33
Gas Pipe
Entry
Electrical
Entry
Condensate
Drain
Thermostat
Wiring
CABINET AND DUCT DIMENSIONS
Models
Nominal
CFM (m
3
/min)
Cabinet
Size
RGF19040AP08MP11 800 A 14 1/2 13 3/8 11 3/4 113
RGF19060BP12MP11 1200 B 17 1/2 16 3/8 13 1/4 122
RGF19080BP12MP11 1200 B 17 1/2 16 3/8 14 3/4 126
RGF19080CP16MP11 1600 C 21 19 7/8 16 1/2 136
RGF19100CP16MP11 1600 C 21 19 7/8 18 1/4 142
RGF19100CP20MP11 2000 C 21 19 7/8 18 1/4 145
RGF19120DP20MP11 2000 D 24 1/2 23 3/8 21 3/4 156
Cabinet Dimensions (Inches)
Operating Weights
A B C Lbs
14”
1”
B
Approximate
RATINGS & PHYSICAL / ELECTRICAL DATA
Models
Input Output
MBH MBH °F °F HP Amps
AFUE
%
Air Temp.
Rise
RGF19040AP08MP11 40 38 95.5 30-60 190 1/3 4.8 11x8 15 8.0 14
RGF19060BP12MP11 60 57 95.5 30-60 190 1/2 7.1 11x8 15 10.0 14
RGF19080BP12MP11 80 76 95.5 35-65 190 1/2 7.1 11x8 15 10.0 14
RGF19080CP16MP11 80 76 95.5 35-65 190 3/4 8.8 11x10 15 11.5 14
RGF19100CP16MP11 100 95 95.5 35-65 190 3/4 8.8 11x10 15 11.5 14
RGF19100CP20MP11 100 95 95.5 35-65 190 1 14.5 11x11 20 17.0 12
RGF19120DP20MP11 120 114 95.5 35-65 190 1 14.5 11x11 20 17.0 12
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
2 Johnson Controls Unitary Products
Max. Outlet
Air Temp
Blower
Blower
Size
Max
Over-Current
Protect
Total Unit
Amps
Min. wire Size
(awg) @ 75 ft
one way