Master MHS5011UR User Guide

MEDIUM DUTY LOGIC
USER'S GUIDE
MH 5011U
MGJ 5011U
MT 5011U BMT 5011U
MJ 5011U
CONTACT INFORMATION
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov
Installation Date
www.liftmaster.com
Radio Receiver
Built on Board
315 MHz

INTRODUCTION

Congratulations on purchasing a quality, LiftMaster Medium Duty Commercial Door Operator. Your new operator is capable of operating up to 12 cycles per hour or 50 cycles per day. It is equipped with a built in radio receiver that is compatible with our existing 315 MHz product line as well as a Timer-to-Close (TTC) feature that can be enabled when LiftMaster Commercial Protector System and aligned properly.
®
is installed

BASIC PROGRAMMING

DETERMINE THE WIRING TYPE

The functionality of this operator is based on the wiring type. The operator is shipped from the factory in standard C2 wiring type (factory default). LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) DEVICE IS RECOMMENDED.
NOTES:
• The LED on the logic board will blink once when in C2 and twice when in B2.
• The operator will automatically convert to B2 wiring when Monitored Entrapment Protection Device is installed. If the Monitored Entrapment Protection Device is blocked or removed, the operator will go into a Restricted Close mode**.
** Restricted close mode requires a constant pressure close command. The operator will begin closing after a 5 second delay and will
continue to close to the close limit switch. The operator will stop if the pressure to close is released before reaching the close limit.
RECOMMENDED INSTALLATION: B2 WIRING TYPE WITH MONITORED ENTRAPMENT PROTECTION DEVICE
• Momentary contact to open, close and stop.
• Open override that reverses when closing by any opening device.
• Wiring for entrapment protection device to reverse.
NOTE: The operator will automatically convert to B2 wiring when Monitored Entrapment Protection Device is installed. (See accessories page for Monitored Entrapment Protection Devices.)
• Timer-to-Close (TTC) feature available.
No Programming Required
MONITORED ENTRAPMENT PROTECTION DEVICE
Photoelectric Sensor
2
BASIC PROGRAMMING

DETERMINE THE WIRING TYPE

ALTERNATE INSTALLATION: C2 WIRING TYPE WITH MONITORED ENTRAPMENT PROTECTION DEVICE
• Momentary contact to open and stop with constant pressure to close.
• Open override that reverses when closing by any opening device.
• Wiring for entrapment protection device to reverse.
NOTE: The operator will automatically convert to B2 wiring when Monitored Entrapment Protection Device is installed. (See accessories page for Monitored Entrapment Protection Devices.)
• Timer-to-Close (TTC) feature not available.
MONITORED ENTRAPMENT PROTECTION DEVICE
ALTERNATE INSTALLATION: C2 WIRING TYPE WITHOUT MONITORED ENTRAPMENT PROTECTION DEVICE
(FACTORY DEFAULT)
• Momentary contact to open and stop with constant pressure to close.
• Open override that reverses when closing by any opening device.
• Wiring for entrapment protection device to reverse.
NOTE: The operator will automatically convert to B2 wiring when Monitored Entrapment Protection Device is installed. (See accessories page for Monitored Entrapment Protection Devices.)
• Timer-to-Close (TTC) feature not available.
NON-MONITORED ENTRAPMENT PROTECTION DEVICE
Photoelectric Sensor
To Program:
Press and hold the LEARN and CLOSE buttons until the LED
1
goes out (approximately 3 seconds).
Electrical Box
C9
L5
^^^^
AUX ANT
AUXANT
R27
J2
TTC
1234567
LMEP1 LMEP2
D9
Logic Board
D7
D5
U4
D6
D4
J4
014A1030
C32
C20
TP1
R25
U1
C21
C31
C18
D14
K2 LT
LEARN
STOPCLOSE OPEN
C29
LED
R24 P1
STOP CLOSE OPEN
INTRLKCOM
1 23 4567
LED
D14
LEARN
STOP CLOSE OPEN
To Reset to B2 with Monitored Entrapment Protection Device:
Press and hold the LEARN and STOP buttons until the LED
1
goes out (approximately 3 seconds).
Sensing Edge
Reset to FACTORY DEFAULT (C2) when the Monitored Entrapment Protection Device has been learned and then removed:
Remove any monitored entrapment protection devices.
1
Turn the main power OFF and then ON to restore the operator
2
to the FACTORY DEFAULT setting.
3
BASIC PROGRAMMING
AUXANT
^^^^
AUXANT
AUX ANT
D14
COMINTRLKSTOP
LED
OPENCLOSE
AUXANT
^^^^
AUXANT
AUX ANT
D14
COMINTRLKSTOP
LED
OPENCLOSE
AUXANT
^^^^
AUXANT
AUX ANT
D14
COMINTRLKSTOP
LED
OPENCLOSE
To prevent possible SEVERE INJURY or DEATH:
• Install a LiftMaster Monitored Entrapment Protection (LMEP) device.
• NEVER permit children to operate or play with door control push buttons or remote controls.

RADIO OPERATION

MODE OPEN CLOSE STOP REVERSE WHILE
B2XXXX
B2 with TTC X X (3-button remote) X X X when open
C2 X X X

REMOTE CONTROLS

Built in 315 MHz radio receiver permits as many as 20 Security® remote controls or dip switch remote controls in any combination.
• Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel.
• ALWAYS keep door in sight until completely closed. NEVER permit anyone to cross the path of closing door.
TTC RESET
CLOSING
SINGLE BUTTON REMOTE CONTROL
Press and hold the button on the remote control until the LED
2
fl ashes rapidly, then release to complete programming (LED will go out).
1
LMEP1 LMEP2
TTC
COM INTRLK STOP
LMEP1LMEP2
1
234567
LEARN
STOPCLOSE OPEN
OPENCLOSE
1
234567
TTC
R27
LED
D14
LEARN
STOP CLOSE OPEN
Press and release the LEARN button (LED will light).
Repeat steps 1 and 2 for additional remote controls.
3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION
NOTE: The feature will use 3 of the 20 memory channels in the operator.
1
LMEP1 LMEP2
TTC
COM INTRLK STOP
LMEP1LMEP2
1
234567
LEARN
STOPCLOSE OPEN
OPENCLOSE
1
234567
TTC
R27
LED
D14
LEARN
STOP CLOSE OPEN
Press and hold the LEARN button (LED will light).
Repeat steps 1 through 3 to program additional buttons.
23
LMEP1 LMEP2
COM INTRLK STOP
OPENCLOSE
1
234567
TTC
R27
LED
D14
LEARN
STOP CLOSE OPEN
Press the desired button on the logic board (OPEN, CLOSE or STOP). Release both buttons.
TO ERASE ALL REMOTE CONTROLS
1
LMEP1 LMEP2
TTC
COM INTRLK STOP
LMEP1LMEP2
1
234567
LEARN
STOPCLOSE OPEN
OPENCLOSE
1
234567
TTC
R27
LED
D14
LEARN
STOP CLOSE OPEN
Press and hold the LEARN button (over 5 seconds) until the LED goes out. All programmed remote controls will be erased.
Press and hold the desired button of the remote control until LED fl ashes rapidly, then release.
4
AUXANT
^^^^
AUXANT
AUX ANT
D14
COMINTRLKSTOP
LED
OPENCLOSE
BASIC PROGRAMMING
AUXANT
^^^^
AUXANT
AUX ANT
D14
COMINTRLKSTOP
LED
OPENCLOSE
AUXANT
^^^^
AUXANT
AUX ANT
D14
COMINTRLKSTOP
LED
OPENCLOSE

TIMER-TO-CLOSE (TTC)

Timer-to-Close feature enables the operator to close from the open limit after a preset time, adjustable from 5 to 60 seconds. Requires LiftMaster Monitored Entrapment Protection (LMEP) device.
TO PROGRAM
Begin with door in fully closed position.
12 4
LMEP1 LMEP2
TTC
COM INTRLK STOP
LMEP1LMEP2
1
234567
LEARN
STOPCLOSE OPEN
OPENCLOSE
1
234567
TTC
R27
LED
D14
LEARN
STOP CLOSE OPEN
Press and release the LEARN button (LED will light).
LMEP1 LMEP2
1
234567
COM INTRLK STOP
OPENCLOSE
Press and
TTC
release the
R27
TTC button.
LED
D14
LEARN
STOP CLOSE OPEN
3
Every press and release
TTC
LMEP1 LMEP2
1
234567
COM INTRLK STOP
OPENCLOSE
of the STOP button
R27
will add 5 seconds to
LED
the Timer-to-Close.
D14
LEARN
Example: 30 second TTC = 6 presses of the
STOP CLOSE OPEN
STOP button.
LMEP1 LMEP2
1
234567
COM INTRLK STOP
OPENCLOSE
TTC
R27
LED
D14
LEARN
STOP CLOSE OPEN
Press and release the TTC button to exit programming mode. The LED will fl ash once per 5 seconds of timer setting.
The TTC will become active after completion of the next open cycle. NOTE: The LED does not indicate that timer is running.
TO VERIFY TIMER-TO-CLOSE (TTC) SETTING
1
1
234567
TTC
R27
LED
D14
LEARN
STOP CLOSE OPEN
Press and hold the LEARN button (LED will light).
LMEP1 LMEP2
TTC
COM INTRLK STOP
LMEP1LMEP2
1
234567
LEARN
STOPCLOSE OPEN
OPENCLOSE
23
LMEP1 LMEP2
1
234567
COM INTRLK STOP
OPENCLOSE
LED
D14
TTC
R27
LEARN
STOP CLOSE OPEN
Press and release the TTC button.
Press and release the TTC button a
TTC
LMEP1 LMEP2
1
234567
COM INTRLK STOP
OPENCLOSE
second time. The LED will fl ash once
R27
per 5 seconds of timer setting.
LED
D14
LEARN
STOP CLOSE OPEN
CLEAR THE TIMER-TO-CLOSE (TTC)
1
1
234567
TTC
R27
LED
D14
LEARN
STOP CLOSE OPEN
Press and release the LEARN button (LED will light).
LMEP1 LMEP2
TTC
COM INTRLK STOP
LMEP1LMEP2
1
234567
LEARN
STOPCLOSE OPEN
OPENCLOSE
23
LMEP1 LMEP2
1
234567
COM INTRLK STOP
OPENCLOSE
TTC
R27
LED
D14
LEARN
STOP CLOSE OPEN
Press and hold the TTC button for 6 seconds.
LMEP1 LMEP2
1
234567
COM INTRLK STOP
OPENCLOSE
TTC
LED
D14
LEARN
STOP CLOSE OPEN
R27
Release the TTC button (LED will go out). The TCC will no longer be active.
TIMER DEFEAT
The TTC can be temporarily disabled by pressing a STOP button. TTC will become enabled after the next open command.
5

TESTING

To avoid SERIOUS personal INJURY or DEATH:
• Disconnect electric power BEFORE performing ANY adjustments or maintenance.
Turn on power, LED will fl ash 4 times on power up. Test all controls and entrapment protection devices to make sure they are working properly. It may be necessary to refer back to the installation manual for adjustment of the limits.
IMPORTANT NOTES:
• Do not leave power to the operator on unless all entrapment protection devices have been tested and are working properly.
• Be sure you have read and understand all safety instructions included in this manual.
• Be sure the owner or person(s) responsible for operation of the door have read and understand the safety instructions, know how to electrically operate the door in a safe manner and how to manually disconnect the door from the operator.
• ALL maintenance MUST be performed by a trained door systems technician.
TEST 3-BUTTON CONTROL STATION
Press OPEN button. (The door should move in the open
1
direction.)
2
Press STOP button. (The door should stop.)
Press CLOSE button. (The door should move in the close
3
direction.)
Release CLOSE button. Door should stop if in C2 mode.
4
(The door should continue closing if in B2 mode.)
Press STOP button. (The door should stop.)
5
TEST LIMIT ADJUSTMENT
Press OPEN button. (The door should open.)
1
Allow the door to fully open.
2
Press CLOSE button. (The door should close.)
3
TEST THE ENTRAPMENT PROTECTION DEVICES
Open the door.
1
Place an obstruction in the path of the photoelectric sensors
2
or sensing edge.
Press the CLOSE button. The door should not close if
3
photoelectric sensors are installed. The door should close to obstruction and reverse if sensing edge is installed.
Remove the obstruction.
4
Press CLOSE button. Door should close.
5
If door did not reverse from obstruction, check entrapment protection devices.
TEST REMOTE CONTROL
Requires B2 wiring type and compatible LiftMaster remote control. In C2 wiring the remote control will open the door only.
Press remote control button.
1
4
Allow the door to fully close.
If the limits are not set properly, remove power and adjust limits (refer to installation manual).
Door should open. Allow the door to fully open.
2
Press remote control button.
3
Door should close. Allow door to fully close.
4
6

EMERGENCY DISCONNECT

The operators have provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions for your model operator.
To prevent possible SERIOUS INJURY or DEATH from a falling door or arm:
• DO NOT stand under the door arm when pulling the emergency release.
• If possible, use emergency release handle to disengage trolley ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.

MODEL MT/BMT

TO DISCONNECT DOOR FROM OPERATOR
Pull emergency release handle straight down. Emergency
1
disconnect will open.
Emergency Disconnect
• NEVER use emergency release handle unless doorway is clear of persons and obstructions.
Emergency Disconnect
Door Arm
TO RECONNECT DOOR ARM TO TROLLEY
Lift free end of door arm to trolley.
1
Pull emergency release handle to allow arm to engage roll
2
pin.
Let go of the emergency release handle. Emergency
3
disconnect will close.
Emergency Disconnect
Door Arm
Door
NO ECIT
Emergency Release Handle
7
EMERGENCY DISCONNECT
To prevent possible SERIOUS INJURY from a moving chain:
• DISCONNECT electric power to the operator BEFORE manually operating your door.
• If possible, use emergency disconnect ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
• NEVER use emergency disconnect unless doorway is clear of persons and obstructions.

MODEL MH

These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used.
Pull the disconnect chain (sash chain) to engage the hoist
1
mechanism. The disconnect chain may be locked in position by slipping the end through the keyhole of the chain keeper mounted on the wall.
Operate the door in the desired direction by pulling on one
2
side or the other of the continuous loop hoist chain.
The disconnect chain must be released from the chain keeper
3
before the door will operate again electrically.

MODEL MHS

The MHS operator includes both a fl oor level disconnect sash chain to disconnect the door from the door operator that allows manual push up operation and an additional sash chain to engage the manual chain hoist that also electrically disables the operator controls.
Refer to Model MH instructions for hoist operation.
1

MODELS MJ AND MGJ

This operator has a fl oor level disconnect chain to disconnect the door from the door operator.
To disengage, pull the chain and secure in the disengaged
1
position by slipping the end through the keyhole bracket mounted on the wall. Or if emergency egress device is used, pull handle to disengage operator from door.
The door may now be pushed up or pulled down manually.
2
Release the disconnect chain or reset the emergency egress
3
device to operate the door again electrically.
EMERGENCY DISCONNECT FOR MODELS MJ
Keyhole Bracket
2
Refer to Model MJ instructions for emergency operation.
When the manual chain hoist sash chain is engaged, electrical operation will not function.
ELECTRICAL INTERLOCK WITH HOIST FOR MODELS MH AND MHS
Chain Keeper (with pad locking provisions)
8

TROUBLESHOOTING

To locate a dealer in your area visit us online at www.liftmaster.com.
CONDITION POSSIBLE CAUSE FIX
OPERATOR WILL NOT RESPOND TO ANY COMMANDS
OPERATOR MAKES NOISE BUT DOOR DOES NOT MOVE
DOOR DRIFTS AFTER OPERATOR STOPS
DOOR OPENS/CLOSES TOO FAR
DOOR REVERSES UNEXPECTEDLY
RADIO FUNCTIONALITY
NO RESPONSE
REMOTE CANNOT BE PROGRAMMED
POOR RANGE
No power Check circuit breaker.
Accessory failure Verify photoelectric sensors are aligned.
Possible component failure Contact your installing dealer.
Operator requires adjustment Contact your installing dealer.
Operator or door requires adjustment
Operator requires adjustment Contact your installing dealer.
Entrapment protection device activated
Remote control is not programmed
Low battery Replace battery.
Low battery Replace battery.
Low battery in remote Replace battery.
Possible radio interference Contact your installing dealer.
Contact your installing dealer.
Verify photoelectric sensors are aligned. If photoelectric sensors are
aligned and operator still does not operate properly, contact your installing dealer.
See PROGRAMMING REMOTE CONTROLS section.

MAINTENANCE SCHEDULE

To avoid SERIOUS personal INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing
Every 3 months or 5,000 cycles repeat all tests in the Testing section. Call qualifi ed service contractor for maintenance. To locate a dealer in your area visit us online at www.liftmaster.com.
The operator should be serviced at the following intervals:
• Every 3 months or 5,000 cycles
• Every 6 months or 10,000 cycles
• Every 12 months or 20,000 cycles
ANY maintenance.
9

OPERATOR NOTES

10
^
^
OPEN
CL
OSE
O
ST
OP

ACCESSORIES

REMOTE CONTROLS 315 MHZ
LiftMaster offers a variety of SECURITY Remote Controls for your application needs. Single to 4-Button, visor or key chain. Contact your authorized dealer.
371LM
1-Button SECURITY® Remote Control:
Includes visor clip.
373LM
3-Button SECURITY® Remote Control:
Includes visor clip.
333LM
3-Button Tri-Colored Dip Switch Remote Control:
Open/Close/Stop functionality. Includes visor clip.
WPB1LM3
Wireless Single Push Button Control SECURITY®:
Rugged composite housing. (Wireless controls cannot be used in place of hard wired controls.)
WPB3LM3
®
ENTRAPMENT PROTECTION DEVICES
CPS-UN4
Commercial Protector System:
LiftMaster Monitored Entrapment Protection (LMEP) provides protection on doors up to 45' wide. NEMA-4 rated.
CPS-U
Commercial Protector System:
LiftMaster Monitored Entrapment Protection (LMEP) provides protection on doors up to 30' wide.
CPS-EI
Monitored Sensing Edge Interface:
Requires 4-wire monitored sensing edge.
65ME1234
Miller ME123 4-Wire Monitored Safety Edge:
For sectional or rolling doors.
65ME110
Miller ME110 4-Wire Monitored Safety Edge:
For rolling grilles and counter shutters.
Wireless 3 Button Control Station SECURITY®:
Rugged composite housing. (Wireless controls cannot be used in place of hard wired controls.)
WKP5LM3 (5 4-digit entry codes) WKP250LM3 (250 4-digit entry codes)
Wireless Access Control Keypads SECURITY®:
Rugged composite housing. (Wireless controls cannot be used in place of hard wired controls.)
CONTROL STATIONS
02-102
2-Button Control Station:
Steel enclosure.
02-103
3-Button Control Station:
Steel enclosure.
MOUNTING BRACKETS
10-12360
Mounting Brackets:
Angle mounting bracket, Painted steel, for MJ,
1
2
3
4
5
6
7
8
9
0
*
#
OPEN
CLOSE
STOP
MH, and MHS.
10-9095
Medium Duty Angle Mounting Bracket:
Heavy-gauge steel bracket. May be welded. For use with MJ, MGJ, and MH operators.
CHAIN TENSIONERS
71-6023
Chain Tensioner:
For 1" shafts
For Jackshaft Type
Operators
02-109
Key Control Station:
Indoor fl ush mount, NEMA 1.
71-6125
Chain Tensioner:
For 1-1/2" shafts
11
ACCESSORIES
FIELD MODIFICATION KITS
71MLSBC
Single Button Control:
Provides additional input for Single Button Control functionality. Input functions as Close input when the operator is stopped at the Open limit. Input functions as Open input at all other times. Also used with external radio controls.
71 MLMOTION
Door-In-Motion:
Provides dry contact and a terminal block with contacts switched to power an auxiliary device while the door is in motion.
ANTENNA
EXT-ANT
Antenna:
External kit for medium duty.
86LM (15') 86LMT (25')
Antenna Extension Kit:
The antenna extension kit can be used with EXT-ANT for maximum radio receiver range.
01-34006F
© 2011, The Chamberlain Group, Inc.
All Rights Reserved
Loading...