Master MH-45-KFA, MH-75T-KFA, MH-190T-KFA, MH-215T-KFA, MH-135T-KFA User Manual

DANGER
WARNING
DANGER
WARNING
KEROSENE FORCED AIR
HEATER
User’s Manual &
Operating Instructions
Model Numbers
MH-45-KFA / MH-75T-KFA / MH-135T-KFA / MH-190T-KFA / MH-215T-KFA
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
Safety Information
GENERAL HAZARD WARNING: READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER.
Be sure to comply with the instructions and warnings provided with this heater. Failure to comply can result in fire or explosion that can cause property loss, bodily injury, or loss of life. Only persons who can follow and understand these instructions should operate or service this heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle Climate Technologies at 800-779-3267.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY
FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is an
unvented portable heater that uses air (Oxygen) from within the area in which it is used. Failure to provide adequate combustion and ventilation air will result in asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to “Ventilation” on Page 5.
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep combustibles such as; building materials, paper or cardboard a
safe distance away from the heater as recommended by these instructions. Never use the heater in spaces which contain products such as; gasoline, solvents, paint thinners, dust particles, volatile or airborne combustibles or any unknown chemicals. This is an unvented portable heater. It uses air (Oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to “Ventilation” on page 5. Bulk fuel storage should be a minimum of 25 feet (7.6 m) from heater.
DO NOT OPERATE THIS HEATER UNTIL
YOU HAVE READ AND THOROUGHLY
UNDERSTAND THESE SAFETY AND OPERATING INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury, property loss or damage from the hazards of fire, soot production, explosions, burns, asphyxiation or carbon monoxide poisoning. Only persons who can read and understand these instructions should use or service this heater.
FACTORY ID: 001
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 779-3267
© 2017 Pinnacle Climate Technologies, Inc. MAKB-400
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
WARNING
WARNING
WARNING
WARNING
DANGER
OR WHILE CONNECTED TO A POWER SOURCE
DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED.
DO NOT START THE HEATER WHEN THE CHAMBER IS HOT.
CALIFORNIA RESIDENTS: This product contains chemicals,
including lead, known to the State of California to cause birth defects or other reproductive harm. Wash hands after handling.
MASSACHUSETTS RESIDENTS: Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part for human habitation. Use of this heating device in Massachusetts requires local fire department permit (M.G.L.C. 148, Section 10A).
NEW YORK CITY RESIDENTS: The New York City Fire Code prohibits the storage, handling and use of kerosene fueled heaters for space heating. Any person violating that provision may be punished by a fine up to $10,000 and a term of imprisonment of up to 6 months.
THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION.
Look for this icon throughout the manual for helpful tips on how to assemble, use and clean your KFA Heater.
RISK OF INDOOR
AIR POLLUTION!
The products described in this manual are
kerosene direct-red, forced air heaters. Kerosene
forced air heaters are primarily intended for use for temporary heating of buildings under construction,
alteration or repair. Direct-red means that all of
the combustion products of the heater enter the heated space. This appliance is rated at 98%
combustion efciency, but does produce small
amounts of carbon monoxide.
CARBON MONOXIDE POISONING MAY
LEAD TO DEATH!
Carbon monoxide is toxic. Humans can tolerate only small amounts of carbon monoxide and so precautions should be taken to provide proper ventilation. Failure to provide proper ventilation in accordance with the instructions in this manual can result in death.
People with breathing problems should consult a physician before using this heater.
Early signs of carbon monoxide poisoning
resemble the u. Symptoms of improper ventilation
/ carbon monoxide poisoning are:
Headache • Dizziness • Nausea Dry Mouth
Sore Throat Burning of Nose and Eyes
If you experience any of these symptoms: GET FRESH AIR AT ONCE! Have your heater serviced and check for proper ventilation. Some people are more affected by carbon monoxide than others. These include: pregnant women, those with heart or lung problems, anemia or those under the influence of alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY FOR: The temporary heating of adequately ventilated buildings or structures under construction, alteration or repair! Provide at least a three square foot (2,800 sq cm) opening of outside air for every 100,000 Btu/Hr (29 kW) heater rating. Refer to “Ventilation” on page 5 for further instructions.
© 2017, Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
1
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
WARNING
WARNING
WARNING
OR WHILE CONNECTED TO A POWER SOURCE
Safety Information
RISK OF
ELECTRIC
SHOCK!
ALWAYS use only the electrical power (voltage and frequency) specified on the model plate of the heater. ALWAYS use only three-prong, grounded outlet and extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly exposed to water spray, rain, dripping water, or wind.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank. Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
45-190T-KFA 215T-KFA
Top
Sides
Front
ALWAYS locate heater on a stable and level surface.
4 ft. (125 cm) 4 ft. (125 cm)
4 ft. (125 cm) 4 ft. (125 cm)
8 ft. (250 cm) 10 ft. (305 cm)
NEVER use fuels such as gasoline, benzine, paint thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the heater is operating or still hot. This heater is EXTREMELY HOT while in operation.
NEVER block air inlet (rear) or air outlet (front).
If your heater is equipped with a thermostat, once it is plugged in, it can start at anytime in accordance with the thermostat setting.
CAUTION!
NEVER use duct work in front or rear of heater.
HOT WHILE IN OPERATION.
RISK OF BURNS,
FIRE AND
EXPLOSION!
DO NOT TOUCH. KEEP CHILDREN, ANIMALS, CLOTHING AND COMBUSTIBLES AWAY FROM HEATER.
Specications
Model # 45-KFA 75T-KFA
Rating: Btu/Hr / kW 45,000 / 13.19 75,000 / 21.98 135,000 / 39.56 190,000 / 55.68 215,000 / 63.01 Fuel Consumption: Gal/Hr / L/Hr 0.35 / 1.32 0.56 / 2.12 1.00 / 3.79 1.42 / 5.38 1.63 / 6.17 Fuel Tank Capacity: Gallons / Liters Pump Pressure: psi / BAR 3.0 / 0.21 4.2 / 0.29 5.5 / 0.38 8.5 / 0.59 9.0 / 0.62
Volts: AC/Hz
Amps 1.4 1.5 2.3 2.7 2.8
Phase Single Single Single Single Single
5 / 19 5 / 19 10 / 38 13 / 49 13 / 49
120VAC / 60Hz 120VAC / 60Hz 120VAC / 60Hz 120VAC / 60Hz 120VAC / 60Hz
Specications subject to change without notice.
135T-KFA 190T-KFA 215T-KFA
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Example:
150812779. Have your Serial Number ready before calling customer service at 800-779-3267.
© 2017, Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
2
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
Wiring Diagrams
45-KFA
75T - 215T-
Assembly Instructions
- Remove the heater and all packaging materials from the shipping carton
What’s In The Box Models: 45-KFA / 75T-KFA
KFA
Note: Save the box and packaging materials for future storage.
Figure 3
Cord Wraps (Optional) Carry Handle (1)
Figure 4
10 mm Screws (2) 13 mm Screws (2)
© 2017, Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
3
Shown With Optional Cord Wraps
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
What’s In The Box Models: 135T-KFA / 190T-KFA / 215T-KFA
Tip: Be sure to remove the axle from the side of the Styrofoam packaging.
Tip: Use a power screwdriver and locking wrench for easier assembly.
50 mm Screws (4)
Axle Nuts (2)
30 mm Screws (4)
Spacers (2)
8 mm Nuts (8)
Front Handle
Tools Needed:
- Phillips Head Screw Driver
- 8 mm open end wrench
- 19 mm open end wrench
Wheels (2)
Wheel Support Frame
Spare Drain Plug (1)
Rear Handle
Axle
Assembly Instructions
Models: 135T-KFA / 175T-KFA / 190T-KFA / 215T-KFA
1. Insert axle through holes in wheel support.
2. Slide spacer onto axle.
3. Slide wheel onto axle and hold in place with the axle nuts. (See Figure 1).
Wheel Support Frame
Tire
Axle
Axle Nut
Spacer
Figure 1
4. Place heater on wheel support and line up holes on the fuel tank lip.
5. Attach front handle with (2) long screws (50 mm) and (2) nuts through the second hole from the front on both sides of the tank lip and wheel support frame and tighten firmly.
6. Insert (2) short screws (30 mm) through the first hole from the front in the tank lip and tighten firmly. Make certain all (4) screws are secure.
7. Attach rear handle with (2) long screws (50 mm) and (2) nuts through the second hole from the rear
© 2017, Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
of the heater on either side. (See Figure 2)
8. Tilt the heater up gently so it is resting on the front handle.
NOTE: DO NOT do this if there is fuel in the tank.
9. Remove the wheels to secure the second set of screws through the rear handle.
10. Secure the rear handle with (2) short screws (30 mm) and (2) nuts and tighten firmly
11. Replace wheels and tighten with the wheel nuts.
12. Tilt heater back down onto wheels and check all screws and nuts to make sure they are secure.
Figure 2
4
Loading...
+ 9 hidden pages