Master MAC-12F, MAC-20FOMNI, MAC-24P, MAC-24POSC, MAC-24W User's Manual & Operating Instructions

...
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
HIGH VELOCITY
WARNING
FAN
User’s Manual &
Operating Instructions
MAC-12F, MAC-20F, MAC-20FOMNI, MAC-24DCT, MAC-24P, MAC-24POSC, MAC-24W,
MAC-24WOSC, MAC-30W, MAC-30WOSC, MAC-30BCT, MAC-30P, MAC-30POSC, MAC-36DCT-BDF
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
IMPORTANT: Read and understand all of the instructions in this manual before assembling, starting, or servicing the fan. Improper use of this fan can cause serious injury. Keep this manual for future reference.
For general ventilating use only. Do not use to exhaust hazardous
CAUTION
or explosive materials and vapors. Never use the fan in spaces which contain products such as gasoline, solvents, paint thinners, dust particles, volatile or airborne combustibles, or any unknown chemicals.
Safety Information
This product can expose you to chemicals, including lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
THIS IS A FAN - NOT A TOY! TO REDUCE THE RISK OF PERSONAL INJURY AND ELECTRIC SHOCK, FANS SHOULD NOT BE PLAYED WITH OR PLACED WHERE SMALL CHILDREN CAN REACH IT.
To guard against electric shock while operating, do not allow fan to come in contact with other grounded objects such as pipes, radiators, etc.
Risk of fire, electric shock, or personal injury when performing ser­vice or maintenance. Unplug or disconnect the fan from the power supply before servicing.
CAUTION: Automatically operated device - to reduce the risk of injury disconnect from power source before servicing
To reduce the risk of fire or electric shock, do not use this fan with any solid- state speed control device.
To Reduce The Risk Of Electric Shock And Injury To Persons, Do Not Use In a Window.
Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized
service facility for examination and/or repair. Do not run cord under carpeting. Do not cover cord with throw rugs , run­ner, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic areas and where it will not be tripped over.
&0
/
,
6
86&
'
(
7
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 779-3267
© 2018 Pinnacle Climate Technologies, Inc. MAVB-406
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING
WARNING
WARNING
WARNING
WARNING
OR WHILE CONNECTED TO A POWER SOURCE
To Reduce The Risk Of Electric Shock, Do Not Expose To Water
Or Rain. This unit is designed for indoor use only.
Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and regulations.
When servicing or replacing a component requires the removal or
disconnection of a safety device, the safety device is to be
reinstalled or remounted as previously installed before operating
this fan.
Use this fan only in the manner intended by the manufacturer. If
you have any questions, contact Customer Service at 800-779-
3267.
- Before operating always check fan for loose or damaged parts. Inspect power cord for any damage. Never use fan if any parts are damaged or missing. Never use fan without safety guards attached.
- Operate only on 120 volt 60 Hz (cycle) current with a minimum of a 15 amp circuit.
12"/20" Floor Fan
MAC-12F
MAC-20FOMNI
20" Omni Floor Fan
MAC-20F
&0
86&
/
'
,
(
6
7
36" Cradle Fan
MAC-36DCT-BDF
&0
86&
/
'
,
(
6
7
MAC-30BCT
&0
/
'
,
(
6
7
30" Floor Fan
&0
86&
/
'
,
(
6
7
- When used with an extension cord, use only cord of proper size (Amp rating), UL listed, and with receptacle to accept three prong grounded plug furnished on the fan’s power cord. Always keep power cord and extension cords away from heat, oil, and sharp edges. Inspect cords periodically and replace if damaged.
24" Barrel Fan
MAC-24DCT
86&
&0
86&
/
'
,
(
6
7
24"/30" Wall Fan
MAC-24W MAC-24WOSC
MAC-30W MAC-30WOSC
&0
86&
/
'
,
(
6
7
© 2018, Pinnacle Climate Technologies, Inc. High Velocity Fan User’s Manual
24"/30" Pedestal Fan
MAC-24P MAC-24POSC
MAC-30P MAC-30POSC
&0
86&
/
'
,
(
6
7
2
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING
WARNING
OR WHILE CONNECTED TO A POWER SOURCE
24" and 30" Wall Fans: MAC-24W / MAC-24WOSC / MAC-30W / MAC-30WOSC
Wall Mount Installation
Tools Needed:
Phillips screwdriver Hex wrench (included in accessory bag)
1. Fix the wall mount to the desired location.
2. Attach the bend pipe to the wall mount with the provided screws. Ensure the screws are tight.
3. Loosen the Phillips head set screw on the lower supporter. Attach the motor to the bend pipe by using the M12x40 screw, nut, and washer to connect the lower supporter to the upper supporter. Tighten the M12x50 screw and the Phillips head set screw. Ensure the screws are tight.
The installer MUST be
certain that the support bracket is mounted to a minimum of a 2x4" stud, and that it is able to support 50 pounds continuously.
4. Remove the four (4) M6x10 Phillips head
ange screws from the motor.
5. Attach the rear guard to the motor with the
four (4) M6x10 Phillips head ange screws.
6. Attach the blade to the motor shaft by using
the hex wrench (in accessory bag). Make sure the hex set screw is facing toward the motor (hub down) when attaching.
7. Attach the front guard to the rear guard, using
the snap joint to tighten.
Exploded View
NOTE: The bolts and screws are mix of metric and standard.
© 2018, Pinnacle Climate Technologies, Inc. High Velocity Fan User’s Manual
3
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING
OR WHILE CONNECTED TO A POWER SOURCE
12" & 20" FLOOR FANS / 24" BARREL FANS / 36 CRADEL FAN:
MAC-12F / MAC-20F / MAC-20FOMNI / MAC-24DCT / MAC-36DCT-BDF
Installation and Assembly
1. Place the fan on level ground in a safe,
desired position then connect to an approved power source.
24" BARREL FAN
Exploded View (MAC-24DCT Only)
30" FLOOR FAN: MAC-30BCT
NOTE: This model CAN NOT be wall mounted.
Installation and Assembly
1. Slide wheel axle through wheel support frame.
2. Slide one (1) wheel onto either side of axle.
This 30" Floor Fan (MAC­30BCT) is approved for use with California’s BAR­97 Emissions Inspection System and meets all BAR-97(EIS) required
specications and standards
3. Secure wheel with one (1) cotter pin.
4. Place the fan on level ground in a safe, desired position
and connect to an approved power source.
Exploded View (MAC-30BCT Only)
© 2018, Pinnacle Climate Technologies, Inc. High Velocity Fan User’s Manual
4
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING
CAUTION
OR WHILE CONNECTED TO A POWER SOURCE
24" & 30" PEDESTAL FANS: MAC-24P / MAC-24POSC / MAC-30POSC / MAC-30P
Installation and Assembly
Tools Needed: Pliers Phillips head screwdriver Flat head screwdriver 10 mm / adjustable wrench
Parts Included In Box: (1) Base (1) Front Guard (1) Rear Guard (1) Motor Assembly (1) Fan Blade Assembly (1) Locking Collar
(1) Upper Support Pole (1) Support Pole Plug (1) Support Pole Spring Bag of Hardware
1. Remove the base from rear guard. Keep the (2) screws holding the base to the rear guard. They will be used to connect the base and lower support pole.
2. Place the base on level ground.
3. Loosen the locking collar on support pole by using the provided Allen wrench (hex wrench). Extract the upper support pole slowly to adjust the height of the fan. The support pole will need to be fully extended before spring is placed inside.
Place spring into bottom of the upper support pole.
4. Place the support pole plug into the bottom of the upper support pole to secure spring in the upper support pole.
5. Mount entire support pole to base. Align holes and use (3) screws from hardware bag and the (2) screws from step 1 to secure entire support pole to the base.
6. Push down the base cover over the base support bolts.
7. Mount the motor assembly to the connector on the upper support pole. Make sure the holes line up
Nut
Figure 1: Attaching Motor to Motor Support Assembly
Figure 2: Attaching Rear Guard to Motor
Motor Assembly
Pivot Bolt
Upper Support Pole
Rear Guard
Motor
8. Secure motor assembly with Bolt (M12*40) and Nut (M12). Tighten the bolt firmly using the wrench.
9. Slide the rear guard onto the motor assembly and secure it with the (4) flange screws (screws from the motor). Tighten the screws firmly using an adjustable wrench.
10. Loosen the screw on the back of the fan blade assembly using the Allen wrench provided (Hex Wrench). Slide the fan blade assembly onto the motor shaft.
11. Tighten the screw on the back of the fan blade assembly using the Allen wrench provided onto the flat part of the fan shaft.
12. Attach the front guard to the back guard and secure with the clips on the front guard
Do NOT slide fan blade screw beyond
the groove on the shaft! This will cause the fan blade to not spin prop­erly and can cause damage to your fan! Be sure that fan shaft is flush with front of fan blade assembly.
NOTE: This model CAN NOT be wall mounted
© 2018, Pinnacle Climate Technologies, Inc. High Velocity Fan User’s Manual
5
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING
OR WHILE CONNECTED TO A POWER SOURCE
24" & 30" PEDESTAL FANS
Exploded View
rear guard
front guard
blades
motor
pivot bolt and nut
upper support pole
motor screws
lower support pole and base screws
support pole spring
base
© 2018, Pinnacle Climate Technologies, Inc. High Velocity Fan User’s Manual
7
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING
OR WHILE CONNECTED TO A POWER SOURCE
1 YEAR LIMITED WARRANTY
PINNACLE CLIMATE TECHNOLOGIES, INC. WARRANTS THIS
PRODUCT TO THE ORIGINAL RETAIL PURCHASER ONLY, TO BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF INITIAL PURCHASE. THIS PRODUCT MUST BE PROPERLY INSTALLED, MAINTAINED AND OPERATED IN ACCORDANCE WITH THE INSTRUCTIONS PRO­VIDED.
PINNACLE CLIMATE TECHNOLOGIES, INC. REQUIRES REASON­ABLE PROOF OF YOUR DATE OF PURCHASE FROM AN AUTHO­RIZED RETAILER OR DISTRIBUTOR. THEREFORE, YOU SHOULD KEEP YOUR SALES SLIP, INVOICE, OR CANCELLED CHECK FROM THE ORIGINAL PURCHASE. THIS LIMITED WARRANTY SHALL BE LIMITED TO THE REPAIR OR REPLACEMENT OF PARTS, WHICH PROVE DEFECTIVE UNDER NORMAL USE AND SERVICE WITHIN THE WARRANTY PERIOD, AND WHICH PINNACLE CLIMATE TECHNOLOGIES, INC. SHALL DETERMINE AT ITS REASONABLE DISCRETION.
THIS WARRANTY DOES NOT APPLY TO PRODUCTS PURCHASED FOR RENTAL USE.
THIS LIMITED WARRANTY DOES NOT COVER REPLACEMENT OF BELTS OR TIGHTENING OF BELTS, OR ANY FAILURES OR OPER­ATING DIFFICULTIES DUE TO NORMAL WEAR AND TEAR, ACCI­DENT, ABUSE, MISUSE, ALTERATION, MISAPPLICATION, IMPROP­ER INSTALLATION OR IMPROPER MAINTENANCE AND SERVICE BY YOU OR ANY THIRD PARTY. FAILURE TO PERFORM NORMAL AND ROUTINE MAINTENANCE ON THE FAN, SHIPPING DAMAGE, DAMAGE RELATED TO INSECTS, BIRDS, OR ANIMALS OF ANY KIND, AND DAMAGE DUE TO WEATHER CONDITIONS ARE ALSO NOT COVERED. IN ADDITION, THE LIMITED WARRANTY DOES NOT COVER DAMAGE TO THE FINISH, SUCH AS SCRATCHES, DENTS, DISCOLORATION, RUST OR OTHER WEATHER DAMAGE, AFTER PURCHASE.
PINNACLE CLIMATE TECHNOLOGIES, INC. WILL REPAIR OR REPLACE AND RETURN THE ITEM, FREIGHT PRE-PAID. IF PINNACLE CLIMATE TECHNOLOGIES, INC. FINDS THE ITEM TO BE IN NORMAL OPERATING CONDITION, OR NOT DEFECTIVE, THE ITEM WILL BE RETURNED FREIGHT COLLECT.
THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. PINNACLE CLIMATE TECHNOLOGIES, INC. DIS­CLAIMS ALL WARRANTIES FOR PRODUCTS THAT ARE PUR­CHASED FROM SELLERS OTHER THAN AUTHORIZED RETAILERS OR DISTRIBUTORS.
AFTER THE PERIOD OF THE ONE (1) YEAR LIMITED WARRANTY EXPIRES, PINNACLE CLIMATE TECHNOLOGIES, INC. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, PINNACLE CLIMATE TECHNOLOGIES, INC. SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. PINNACLE CLIMATE TECHNOLOGIES, INC. ASSUMES NO RESPONSIBILITY FOR ANY DEFECTS CAUSED BY THIRD PARTIES. THIS LIMITED WARRANTY GIVES THE PURCHASER SPECIFIC LEGAL RIGHTS; A PURCHASER MAY HAVE OTHER RIGHTS DEPENDING UPON WHERE HE OR SHE LIVES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITA­TION OF SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON HOW LONG A WARRANTY LASTS, SO THE ABOVE EXCLUSION AND LIMITATIONS MAY NOT APPLY TO YOU.
PINNACLE CLIMATE TECHNOLOGIES, INC. DOES NOT AUTHORIZE ANY PERSON OR COMPANY TO ASSUME FOR IT ANY OTHER OBLI­GATION OR LIABILITY IN CONNECTION WITH THE SALE, INSTAL­LATION, USE, REMOVAL, RETURN, OR REPLACEMENT OF ITS EQUIPMENT, AND NO SUCH REPRESENTATIONS ARE BINDING ON
PINNACLE CLIMATE TECHNOLOGIES, INC.
ALL TRANSPORTATION COSTS FOR THE RETURN OF THE DAM­AGED PRODUCT OR PARTS WILL BE THE RESPONSIBILITY OF THE PURCHASER. UPON RECEIPT OF DAMAGED ITEM, PINNACLE CLIMATE TECHNOLOGIES, INC. WILL EXAMINE THE ITEM AND DETERMINE IF DEFECTIVE.
ALWAYS BE SURE TO SPECIFY MODEL NUMBER AND SERIAL NUMBER WHEN MAKING ANY CLAIM WITH PINNACLE CLIMATE TECHNOLOGIES, INC. FOR YOUR CONVENIENCE USE THE SPACE PRO­VIDED BELOW TO LIST THIS INFORMATION:
Model #: ____________________ Serial #: ______________________
Date of Purchase: _________________
© 2018, Pinnacle Climate Technologies, Inc. High Velocity Fan User’s Manual
Loading...
+ 14 hidden pages