DSH1011 PB Emissione 2012-09-19 MCZ Rev. F 2015-04-16

FUNCTIONING PRINCIPLES
The device works on the principle of forced convection. The air flow is forced by a fan. Cold air is sucked
from the back of the unit. The resistances heat the air. The heated air is expelled from the front of the
heater. The unit is equipped with thermal protection with reset and a cooling thermostat. Switch
positions: ventilation, heating with half power, heating at full power.
Max capacity
Power source
Net weight
Gross weight
Noise level
Air displacement
Packaging dimensions
Device dimensions
TECHNICAL DATA
kW
Kcal/h
Btu/h
Electrical energy
kg 53
kg 63
dB(A) 71
m³/h 3500
mm
mm
30
25813
102364
Power supply
Rated current
PACKAGING
Frequency
1050x585x820
1030x580x680
V 400V
Hz 50
A 43,5
Pieces for pallet
Pieces per truck 80m
DSH1011 PB Emissione 2012-09-19 MCZ
3
n°
n°
1
132
Rev. F 2015-04-16

COMPONENTS
Heating elements
Temperature limiter
Fan
Thermal protection
Cooling thermostat
Thermostat connector
Contactor
Motor
Supply conductor
Room thermostat
Hot air hoses
3000W
With capillary
∅
∅400mm
∅∅
110oC
40oC
TH5
4kW
Asynchronous, threephase, with thermal protection,
clockwise rotation, 1380 rpm
ACCESSORIES
5m i 10m
Thermostat TH5
Hose ∅∅∅∅405mm
WIRING DIAGRAM
L1 Phase
L2 Phase
L3 Phase
N
PE
WR Thermal cut-out
WZ Owerheat sensor
R1 Heating element
R2 Heating element
R3
R5 Heating element
R6 Heating element
R7
R8
R9
R10
R11
R12
TA
TR
C1
C2
S
M Motor
:
:
Neutral
:
Ground
:
Heating element
Heating elementR4
Heating element
Heating element
Heating element
Heating element
Heating element
Heating element
Thermostat
Thermostat
Contactor
Contactor
Switch