Mastech MS6252B Operation Manual

Page 1
MS6252B
Digital Anemometer
Operation Manual
MS6252B
Digital Anemometer
FUNC
HOLE MODE
MAX
MIN
USB
DP WB
MAX MIN
VEL FLOW AREA
USB
°C °F
%RH
m
2
ft
2
x10
ft/m ml/h
ft/s km/h
knots
m/s
FPM CMM CFM CMS
Page 2
1. Safety Information................... ... .....1
1.1 Preparation........................................1
1.2 Usage................................................1
1.3 Marking.............................................1
1.4 Maintenance......................................2
CONTENTS CONTENTS
2. Description..........................................3
2.1 Part name..........................................3
2.2 Button description..............................6
2.3 Sign definition....................................7
3. Specification......................................8
3.1 General.............................................8
3.2 Technique data.................................9
4. Operating Guidance.........................11
4.1 Power On/Off...................................11
4.2 Reading hold ...................................11
4.3 Backlight function.............................12
4.4 Wind speed measurement................12
4.5 Wind speed unit selection.................13
4.6 Area setting......................................13
4.7 Air volume measurement..................13
4.8 Air volume unit selection...................14
4.9 Temperature unit selection................14
4.10 Temperature mode selection...........14
4.11 USB real time data uploading..........14
4.12 Use tripod connection receptacle.....15
4.13 Replace battery...............................16
5. Attachments............................................16
Page 3
Page 4
03 04
2. DESCRIPTION
-Thi s meter is a di gital ane mometer for measurin g the am bient tem peratur e, humidity, dew p oint temp erature , wet bulb te mperature, wind spee d, and ai r volume.
-Thi s meter is a po rtable, p rofessional measur ing inst rument wi th large- screen LC D and backlig ht, mult i-unit sw itching f unctions.
-Thi s meter can b e used for ha nd-held o r fixed meas urement .
-Thi s meter has t he functi ons of reading hold, maxi mum, mini mum, etc.
-It ha s a low batte ry indica tor and USB real time data u ploadin g functio ns.
2.1 Part name
(1) Fa n (2) LC D (3) “F UN” — Funct ion switc hing button (4) “ ”— P ower swit ch (5) “U NIT” — Unit s witchin g button (6) Ma ximum/M inimum bu tton (7) “HOLD/MODE” hold display, switch temperature mode (8) “ /U SB” — Backl ight/US B real time data uplo ading fun ctions (9) Fa n retaini ng bolt hol e (10) C onnecti on hole for f ixing mea surement bracket (11) Batt ery housing cover reta ining bol t hole (12) B attery co ver
FRONT PA N E L
1
2
3 4
5 6
7
8
MS6252B
Digital Anemometer
FUNC
HOLE MODE
UNIT
MAX
MIN
USB
DP WB
MAX MIN
VEL FLOW AREA
USB
°C °F
%RH
m
2
ft
2
x10
ft/m ml/h
ft/s km/h
knots
m/s
FPM CMM CFM CMS
Page 5
Page 6
07 08
3. SPECIFICATION
The me ter shoul d be recali brated un der the condition of 18° C~28°C, r elative h umidity <75% every yea r.
3.1 General
3.1. 1 Wo rk height: Maximum 200 0m
3.1. 2 Wo rk mode: Freq uency of wi nd speed co nversion
3.1. 3 Display : LCD
3.1. 4 Maximum s how value : 9999
3.1. 5 Samplin g time: Abou t 0.4s/time.
3.1. 6 Low batte ry indica tor: sign displays on LC D.
3.1. 7 Wo rk power: 1×9V 6F22 batt ery.
3.1. 8 Operati on enviro nment: Rela tive humi dity–0~ 85%RH, no moi sture con densati on Temperat ure–0°C ~40°C, no moi sture con densati on
3.1. 9 Detecto r (fan) ope ration environment : Rela tive humi dity– 0~9 5%RH, no moi sture con densati on. Temperat ure–-20 °C~80°C , no moi sture con densati on.
3.1. 10 Storag e environ ment: Rela tive humi dity– 0~8 0%RH, no moi sture con densati on Temperat ure–-10 °C~50°C , no moi sture con densati on
3.1. 11 Di mension : Meter –165L X85 WX38H mm.
3.1. 12 Weight: Abo ut 200g
2.3 Sign defin ition
Indi cates Auto P ower-Off status
H Read ing hold st ate VEL Wi nd speed me asureme nt state FLOW Ai r volume me asureme nt state AREA Ar ea settin g require d by air volu me DP Indic ates that the c urrent mo de is dew poi nt
temp erature m ode WB Ind icates th at the curr ent mode is wet b ulb temp erature m ode
°C, °F Tem peratur e unit %RH Re lative hu midity si gn USB In dicates t hat USB rea l time data uploading
is ena bled MAX Di splays ma ximum aft er entering maxi mum/min imum mode MIN Di splays mi nimum aft er entering maxi mum/min imum mode Ind icates th at the current area sett ing unit is squ are meter ft² In dicates t hat the current area set ting unit is squ are foot
CMM Cu bic meter s per minut e CMS Cu bic meter s per secon d CFM Cu bic meter s per minut e knot s Nautica l miles per h our, 1850 me ters per hour ft/s F eet per sec ond ft/m F eet per min ute m/s Me ters per se cond Km/h K ilomete rs per hour mil/ h Nautica l miles per h our
Low ba ttery ind icator
Page 7
Page 8
Page 9
Page 10
(1) Ba ttery 9V, NEDA 1604, 6F 22
(2) De tector Br acket
(3) Pa ckaging B ag
(4) Op eration M anual
(5) CD
4.13 Replacing battery
4.13 .1 If the “ ”si gn appear s, this indicates that
the ba ttery sho uld be repl aced.
4.13 .2 Power off the meter and rem ove the bat tery cove r.
4.13 .3 Replac e the old bat tery.
4.13 .4 Instal l the batte ry cover properly.
5. ATTACHMENTS
1pc
Opti onal
1pc
1pc
1pc
15
enab le the USB fu nction of t he meter.
5.Th e PC softwa re displa ys data and d iagrams.
6. Sav e or print da ta.
4.12 Using tri pod connection receptacle
4.12 .1 When nec essary, the mete r can be fixe d on a trip od.
4.12 .2 When nec essary, the mete r can be used b y hang .
16
ONL INE
HYS006709
Loading...