Marvel Refrigeration ML15CR Installation Manual

Installation Operation and Maintenance Instructions
Ice Machine
ML15CRS1XS
ML15CRS1XB ML15CRP1XP
Installation Operation and Maintenance Instructions
Intro
Safety
Safety and Warning
Disposal and Recycling
Installation
Environmental Requirements
Electrical
Cutout Dimensions
Product Dimensions
Side by Side Installation Water
Hookup
Anti-Tip Bracket
General Installation
Service
Troubleshooting
Warranty
Obtaining Service
Overlay Door Panel Dimensions
Overlay Door Panel Installation
Grille Installation
Door Swing
Door Adjust
Operating Instructions
First Use
Ice
Airflow and Product Loading
Maintenance
Cleaning
Cleaning Condenser
Extended Non-Use
2
Installation Operation and Maintenance Instructions
Welcome to the Marvel Experience
Congratulations on adding a new Marvel crescent ice maker to your home and thank you for choosing our quality American-built product. You’ll enjoy years of crescent ice in the comfort and convenience of your home, backed by our full worry-free warranty. We are thrilled to welcome you to our growing community of Marvel owners, who trust in our products and our support.
The information in this guide is intended to help you install and maintain your new Marvel crescent ice maker to protect and prolong the lifetime of your unit. We encourage you to contact our Technical Support team at (800) 223-3900 with any questions.
Cheers!
3
Installation Operation and Maintenance Instructions
DANGER
!
WARNING
!
CAUTION
!
WARNING
!
DANGER
!
CAUTION
!
Safety and Warning
NOTICE
Please read all instructions before installing, operating, or
servicing the appliance.
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a Danger,
Warning or Caution based on the risk type:
Danger means that failure to follow this safety statement
will result in severe personal injury or death.
Disposal and Recycling
RISK OF CHILD ENTRAPMENT. Before you throw away
your old refrigerator or freezer, take off the doors and leave
shelves in place so children may not easily climb inside.
If the unit is being removed from service for disposal, check and
obey all federal, state and local regulations regarding the
disposal and recycling of refrigeration appliances, and follow
these steps completely:
1. Remove all consumable contents from the unit.
2. Unplug the electrical cord from its socket.
3. Remove the door(s)/drawer(s).
Warning means that failure to follow this safety statement
could result in serious personal injury or death.
Caution means that failure to follow this safety statement
may result in minor or moderate personal injury, property
or equipment damage.
CALIFORNIA PROPOSITION 65
This product contains chemicals known to the state of
California to cause cancer and birth defects or other
reproductive harm.
www.P65warnings.CA.gov
Environmental Requirements
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce the
unit’s ability to reach low temperatures and/or reduce ice
production on applicable models.
For best performance, keep the unit out of direct sunlight and
away from heat generating equipment.
In climates where high humidity and dew points are present,
condensation may appear on outside surfaces. This is
considered normal. The condensation will evaporate when the
humidity drops.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
4
Installation Operation and Maintenance Instructions
WARNING
!
Electrical
SHOCK HAZARD — Electrical Grounding Required. Never
attempt to repair or perform maintenance on the unit until
the electricity has been disconnected.
Never remove the round grounding prong from the plug
and never use a two-prong grounding adapter.
Altering, cutting or removing power cord, removing power
plug, or direct wiring can cause serious injury, fire, loss of
property and/or life, and will void the warranty.
Never use an extension cord to connect power to the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded
(three-prong), polarized receptacle that has been placed
by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz,
15A power supply (normal household current). An individual,
properly grounded branch circuit or circuit breaker is
recommended. A GFCI (ground fault circuit interrupter) is
usually not required for fixed location appliances and is not
recommended for your unit because it could be prone to
nuisance tripping. However, be sure to consult your local codes.
Cutout Dimensions
PREPARE SITE
Your Marvel product has been designed for either free-
standing or built-in installation. When built-in, your unit does
not require additional air space for top, sides, or rear.
However, the front grille must NOT be obstructed, and
clearance is required for an electrical connection in the rear.
CAUTION
!
Unit can NOT be installed behind a closed cabinet door.
CUTOUT DIMENSIONS
Preferred location for water line and
electrical outlet is in
34-1/4"
(870 mm)
to 35"
(889 mm)
adjacent cabinet.
7"
(178 mm)
4"
(102 mm)
15-1/4"
(387 mm)
24"
(610 mm)
5/8"
(16 mm)
See CUTOUT DIMENSIONS for recommended receptacle
location.
5
Product Dimensions - ML15CRS1XS & ML15CRS1XB
Installation Operation and Maintenance Instructions
Not Including Handle
*Add 3/4" To Depth For Water Line Clearance
6
Installation Operation and Maintenance Instructions
Product Dimensions - ML15CRP1XP
Includes 3/4" (20 mm) Overlay Panel
*Add 3/4" To Depth For Water Line Clearance
7
Installation Operation and Maintenance Instructions
Side-by-Side Installation
Two units may be installed side-by-side.
Cutout width for a side-by-side installation is the cutout
dimension of a single unit times two.
No trim kit is required. However, 1/4" (6 mm) of space needs to
be maintained between the units to ensure unobstructed door
swing.
Units must operate from separate, properly grounded electrical
receptacles placed according to each unit’s electrical
specifications requirements.
Side-by-Side Installation with Bracket
1. Slide both units out so screws on top of units are easily
accessible.
3. Place bracket over holes and attach to unit with two screws
removed in step 2 using a T-25 Torx driver. Tighten screws
fully.
4. Gently push units into position. Be careful not to entangle
the electrical cord or water line, if applicable.
5. Re-check the leveling, from front to back and side to side.
Make any necessary adjustments. The unit’s top surface
should be approximately 1/8" (3 mm) below the countertop.
2. Remove screws as shown below.
8
Loading...
+ 18 hidden pages