Remove Packaging
Your drawer refrigerator has been packed for ship­ment with all parts that could be damaged by movement securely fastened. Before installing the drawer refrigerator, be sure all packing materials and tape have been removed.
Important
Save the carton packaging until your drawer refrigerator has been thoroughly inspected and found to be in good condition. If there is damage, the packaging will be needed as proof of damage sustained in transit.
Note to Customer
This unit was carefully packed and thoroughly inspected before leaving our plant. Responsibility for its safe delivery was assumed by the carrier upon acceptance of the shipment. As directed on the side of the packaging carton, claims for loss or damage sustained in transit must be made on the carrier as follows:
Exterior Damage
Make a thorough damage notation on the delivery receipt and have the driver acknowledge by sign­ing and dating. Send a written request asking for an inspection report from the carrier representa­tive and the date the inspection was requested. Retain the inspection report and receipt for filing of a claim.
Concealed Damage
This must be reported to the carrier within fifteen days. Obtain an inspection report from the carrier. Retain the inspection report for filing of the claim. DO NOT RETURN DAMAGED MERCHANDISE TO THE MANUFACTURER - FILE THE CLAIM WITH THE CARRIER.
STARTING OUT
2
Select Location
The proper location will ensure peak perform­ance of your drawer refrigerator. Choose a loca­tion away from heat and out of direct sunlight. Best performance will be maintained when installed within the following parameters:
Cabinet Clearance
Ventilation is required for the bottom front section of the unit where the grille is located. Keep this area open and clear of any obstructions. Adjacent cabi­nets and countertop can be installed on top, back and sides of the unit as long as grille and drawer access remain unobstructed. An opening of 30” is required between cabinets with a depth of 24”.
Adjacent cabinets and countertop can be installed on top, back and sides of the unit as long as the grille and drawer access remain unobstructed. Ventilation is required for the bottom front section of the unit where the grille is located. Keep this area open and clear of any obstructions.
Make certain that the leveling legs supplied with the drawer refrigerator are installed according to the instructions. Leveling adjustments can be made by raising or lowering the glides on the bot­tom of the unit.
Important Safety Issue
A cabinet “anti-tip” device is mounted to the back of your drawer refrigerator. If your installation is a built-in undercounter application, you do not need to apply this feature.If your installation is a free­standing application with no counter top directly above the top of the drawer refrigerator, you must apply this feature to prevent the unit from tipping forward when the drawers are pulled out. The “anti-tip” device is attached at the back of each cabinet. Please see installation instructions sup­plied with the “anti-tip” device.
Electrical Connection
Check the serial nameplate for the correct power supply. Use only the electrical power supply spec­ified on the serial nameplate. Do not use an exten­sion cord.
Grounding Method
This drawer refrigerator is equipped with a power supply cord with ground. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. It is the customer’s responsibility to provide the proper grounding type receptacle. Do not alter the plug in any way.
INSTALLATION
21.81
23.88
15.13
15.13
3.50
29.88
25.82
34.00
Ideal Ambient Temperature Range
*
built-in freestanding
55-80°F 55-90°F
* Drawer Refrigerator will not perform correctly in ambient temperatures less than 55°F.
THIS UNIT SHOULD NOT, UNDER ANY
CIRCUMSTANCES, BE UNGROUNDED.
DISCONNECT POWER SOURCE BEFORE
ADJUSTING LEVELING LEGS
3
Control Panel
The temperature of your drawer unit ranges from 32°F to 47°F (0°C to 8°C). The temperature can be adjusted using the control panel located on the inside of the top drawer. To change the tempera­ture setting, press the warmer or cooler pads until the display shows the desired temperature. After a few seconds the display will return to the actual temperature of the unit. An empty unit will stabilize in six to eight hours.
Your drawer refrigerator’s control leaves the facto­ry preset to display its temperature in degrees Fahrenheit. To change the display to show Celsius temperatures, simply press the warmer and cold­er key pads simultaneously. The display will change within a few seconds.
The on/off key pad stops and starts the cooling of the unit. This can be used when your drawer refrigerator will not be used for extended periods of time. The LED light will continue to operate when the drawers are opened as long as the unit is connected to a power source.
At time of initial start up the control panel display will show “OR” or “Out of Range” until the unit reaches the desired temperature. At any time the unit’s interior temperature reaches 9 degrees below or above its setpoint this code will also be displayed.
FEATURES
ON
OFF
Gastronorm Container Systems
For additional convenience, optional Gastronorm food storage containers can be purchased from your dealer. These stainless steel containers can be used to easily access smaller food items and are dishwasher safe. For further information visit Marvel’s website at: www
.marvelindustries.com.
Drawer Organizer
The Drawer Organizer is designed to be fully adjustable to compensate for bottles and other items of different sizes. The drawer Organizer can be adjusted left and right, up and down by turning the knob counter clockwise.
4
TEMPERATURE CONTROL
COOLER
WARMER