MARVEL OUTDOOR REFRIGERATED DRAWERS
Installation
Operation
and
Maintenance
Instructions
Outdoor
24” Refrigerated Drawers
6ORDE
UNPACKING YOUR OUTDOOR REFRIGERATED DRAWERS
Remove Packaging
Your outdoor refrigerated drawers have been packed for
shipment with all parts that could be damaged by movement
securely fastened. Before using, be sure all packing materials
and tape have been removed.
Important
Keep your carton packaging until your refrigerated drawers
have been thoroughly inspected and found to be in good
condition. If there is damage, the packaging will be needed
as proof of damage in transit.
Note to Customer
This merchandise was carefully packed and thoroughly
inspected before leaving our plant. Responsibility for its safe
delivery was assumed by the retailer upon acceptance of the
shipment. Claims for loss or damage sustained in transit
must be made on the retailer as follows:
Exterior and Concealed Damage •
Any damage must be reported immediately to your retailer.
DO NOT RETURN DAMAGED MERCHANDISE TO THE
MANUFACTURER - FILE THE CLAIM WITH THE RETAILER.
REMINDER
IT IS IMPORTANT THAT YOU SEND
IN YOUR WARRANTY RECORD CARD
IMMEDIATELY AFTER TAKING DELIVERY
OF YOUR REFRIGERATED DRAWERS.
Outdoor 6ORDE Refrigerated Drawer Specifications
Exterior Cabinet Dimensions
HxWxD (in.)
Finished Cut-Out Opening
Dimensions
HxWxD (in.)
Weight 170 lbs.
Capacity 5.8 cubic feet
Temperature 33-47
Power Supply
supplied with a 15 amp plug
1
34 x 23 7/8 x 24 1/4
34 1/2 x 24 x 24
°F
115V
INSTALLING YOUR OUTDOOR REFRIGERATED DRAWERS
Select Location
The proper location will ensure peak performance of your
appliance. Choose a location where the unit will be out of
direct sunlight and away from heat sources. Best performance will be maintained when installed within the following parameters:
Unit should be operated in a properly ventilated area with
ambient temperatures above 40 degrees and below 100
degrees Fahrenheit.
Cabinet Clearance
Ventilation is required from the bottom front section of the
unit. Keep this area open and clear of any obstructions.
Adjacent cabinets and countertop can be installed on top,
back and sides of the unit as long as the grille and door
access remain unobstructed. An opening of 24 inches is
required between cabinets and a depth of 24 inches.
Leveling Legs
Adjustable legs at the front corners of the unit should be
set so the unit is firmly positioned on the floor and the front
is raised just enough so that the door closes easily when
opened about halfway.
Turn leveling legs clockwise to raise unit, counterclockwise
to lower it.
WARNING
Do not splash or spray water from a hose on the re-•
frigerator! Doing so may cause an electrical shock,
which may result in severe injury or death.
This unit should not, under any circumstances, be •
ungrounded.
Grounding Method
This product is factory equipped with a power supply cord
that has a three-pronged, grounded plug. It must be
plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable
local codes and ordinances (see Figure 1). If the circuit
does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange the
existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The
third ground prong should not, under any circumstances,
be cut or removed. All U.L. listed refrigerated products are
equipped with this type of plug.
A ground fault circuit interrupter electrical receptacle is
to be used to supply electrical power to the refrigerator
for outdoor applications. Contact an electrician if you
need to install one to supply electrical power to your
outdoor refrigerator.
“Anti-Tip” Device
A cabinet “anti-tip” device is mounted to the back of your
refrigerated drawers. If your installation is a built-in undercounter application, you do not need to apply this feature.
If your installation is a free-standing application with no
countertop directly above the top of the unit, you must
apply this feature to prevent the unit from tipping forward
when the drawers are pulled out. The “anti-tip” device is
attached to the back of the cabinet. Please see installation
instructions supplied with the “anti-tip” device.
Electrical Connection
Check the serial nameplate for the correct power supply.
Use only the electrical power supply specified on the serial
nameplate. DO NOT USE AN EXTENSION CORD.
Figure 1
2
SENTRY SYSTEM™ REFRIGERATION MONITOR
38
Start Your Appliance
Your appliance will start upon initial plug-in. The LED will
flash amber upon initial plug-in due to your unit being
powered-on at the factory to verify performance and then
powered-off. The Sentry System™ refrigeration monitor
senses a power outage has occurred and relays this information to you when you initially power-up your appliance.
This is normal and pressing the “ON/OFF” button will reset
this alarm function.
If your appliance’s control has been shut-off (i.e., unit
plugged in, interior lights operate, display blank), unit must
be turned on. To turn on your appliance, push and hold
for five (5) seconds, the “ON/OFF” button located on the
display panel (see Figure 2).
Once products are loaded, allow at least 48 hours for
the unit to stabilize before making any adjustments to the
initial setting.
Set Your Temperature Mode
This product can display either Fahrenheit or Celsius. To
do so, press the “°F/C” button on the display panel.
Set the Controls
The available temperature range of the unit is from 33 to
47 degrees F. The temperature set point is initially set in
the factory at 38 degrees F. The temperature set point can
be lowered or raised by first pushing the “SET” button on
the display pad. A “SET” icon will be displayed. Pushing
either the “WARMER” or “COLDER” buttons located on the
display pad will raise or lower the set temperature by one
(1) degree F or C (depending on your setting). As with any
refrigeration product, there is a slight temperature variance
at different locations within the cabinet.
Figure 2
Interior Light
The upper and lower interior lights make it easy to view
your food and beverages. The light will always come on
when either drawer is opened.
Warning Alarms
Your refrigerated drawers have been fitted with a Sentry
System™ refrigeration monitor. This monitor will let you
know if your drawers are not functioning properly for optimum food and beverage storage.
Door Ajar Alarm
If the door has been left open for over five (5) minutes, the
alarm will sound and the LED will flash green. This will
stop as soon as the door is closed.
High and Low Temperature
If your unit reaches temperatures outside normal operating
temperatures for your set point for more than one (1) hour,
an alarm will sound and the LED will flash red. This will
warn you that your contents have seen temperatures that
may not be conducive for long-term storage.
Power Failure
If your unit experiences a power failure, the LED will flash
amber until the alarm is reset.
Reset Alarms
Press the “ON/OFF” button for approximately one (1) second. This will reset all audible and display alarms.
Sabbath Mode
Your refrigerated drawers are equipped with a Sabbath
Mode feature. By activating this mode, you will be disabling all displays, audible alarms and lights.
Adjustable Temperature Control
The temperature control is fully adjustable from the low
thirties to the high forties. The range allows flexibility of
temperature preferences.
3
To activate the Sabbath Mode, press and hold the “SET”
button while pressing the “
seven (7) seconds. To disable Sabbath Mode, repeat the
process. Sabbath Mode will automatically deactivate after
72 hours.
°F/C” button four (4) times within