Martin Professional CYCLO 02, CYCLO 04, CYCLO 03 User Manual

Page 1
martinarchitectural
l
Cyclo
user manua
Page 2
Measurements are in millimeters
Cyclo 03
Cyclo 02
Cyclo 04
63
Cyclo 02
88
Cyclo 03
81
1000
88
Cyclo 04
All rights reserved. No part of this manual may be reproduced, in any form or by an y means , with-
out permission in writing from Martin Professional A/S, Denmark.
98
88
© 2002 Martin Professional A/S, Denmark.
Printed in Denmark.
P/N 35000124, Rev C
Page 3
I
NTRODUCTION
Thank you for selecting the Martin Cyclo. The Cyclo Series is a range of controllable, fluorescent color changers. These fixtures are designed to be used for cove lighting, perimeter lighting, light walls, behind semi­transparent materials, or any place where room is restricted.
Cyclo is a family of fixtures based on dimmable fluorescent T5 tubes. The T5 tubes have achiev ed widespread popularity due to their sleek design and high efficacy combined with their long lamp life.
In order to be DMX controlled, the Cyclo fixtures require the Martin 516 DMX to 0-10 V Converter. The 516 Conver ter converts DMX to 0-10 V analog output. Additional Cyclos can be daisy-chained for synchronous dimming. A single 516 Controller can control 4-8 Cyclo groups individually, each group consisting of one to ten of the same Cyclo model wired in series (the number of groups depends on the model of Cyclo that is installed). The member fixtures in each group will react similarly when controlled.
Cyclo control and power-cables are through-wired for easy installation. The Cyclo series offers:
Controllable RGB color-mixing and/or color temperature
Bright output
Long lamp life of 20,000 hours
Note: It is important to read this manual through before you attempt
to install this product.
Cyclo fixtures
CYCLO 02
Cyclo 02 contains a single warm white tube and a single cold white tube. It is designed as a functional lighting fixture for applications where dimmable
color temperature control ranging from 2700K up to 6000K are desirable.
CYCLO 03
Cyclo 03 contains dimmable red, green and blue tubes and is a cost efficient RGB solution.
Cyclo user manual
3
Page 4
CYCLO 04
Cyclo 04 contains dimmable red, green, blue and white tubes, and provides a wider color range.
SAFETY INFORMATION
Warning! This product is for professi onal use only. It is not for household
use.
These products present risks of lethal or severe injury due to fire and heat, electric shock and falls. Read this manual before powering or installing these fixtures, follow the safety precautions listed below and observe all warnings in this manual and on the fixtures. If you have questions about how to operate these fixtures safely, please contact your Martin dealer or call the Martin 24-hour service hotline at +45 70 200 201.
Protection from electric shock
• Disconnect the fixtures from AC power before removing or installing a lamp, fuses, or any part, and when not in use.
• Always ground (earth) the fixtures electrically.
• Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protection.
• Do not expose the fixtures to rain or moisture.
• Refer all service to a Martin service technician.
Protection from burns and fire
• Provide a minimum clearance of 0.1 meters (4 inches) around the fixture.
• Do not modify the fixture or install other than genuine Martin parts.
• Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
Protection from injury due to falls
• Verify that all external covers and rigging hardware are securely fastened
• Block access below the work area wheneve r installing or removing the fixture.
4
Cyclo user manual
Page 5
I
NSTALLATION
This section describes in general terms how to install the fixture and connect it to AC and dimmer power. These procedures shall be performed by qualified professionals.
Mains
200-250V AC
50/60 Hz
516
DMX control device
Open the fixture:
1 Remove the fixture’s clear plastic
cover using a 2.5 mm Allen wrench.
2 Carefully remove each of the tubes by
rotating them (at the ends) until you are able to pull one end out, and then remove the entire tube.
DMX-to-analog (10V) converter
3 Using a Phillips screwdriver, loosen the two screws holding the cover of the
wiring housing in place; remove the cover.
Cyclo user manual
5
Page 6
To ensure adequate ventilation, we recommend that the Cyclo be installed with a minimum of 25 mm (1 inch) of free space on each side. Screw the fixture into place using, either:
2 x 10 mm hardware together with the supplied washers, separated by 1 metre (3.3 feet), or
4 x 8 mm hardware, in a matrix 1 metre by
6.5 cm square Connect the AC power and dimmer control wiring (as described in the
following sections) before replacing the wiring-housing cover, the tubes, and the clear plastic cover.
Ø8
Ø10
Ø8
AC POWER
Maximum power usage data for the three Cyclo models in supplied in “Specifications - Cyclo 02” on page 11.
You can power Cyclo fixtures by wiring them in series. The internal wiring of the fixtures carries AC power through the fixture. Holes are supplied at both ends for input and output cables.
Warning: In the Cyclo series fixtures incorporate a single electronic
ballast per tube. Each of these “leaks” around 0,2 til 1 mA of power. Because of this we recommend connecting a maximum of 30 electronic ballasts (or tubes) per phase on a 30mA HPFI circuit breaker.
A normal 30 mA HPFI circuit breaker normally trips because of a current fault or leakage of approximately 20mA. It is important that the installation is carried out correctly in order to avoid unintentional tripping of the circuit breaker.
Many installations use common neutral leads in branch circuit distribution boxes. It i s important that the neutral lead in the cable is connected to the same HPFI circuit breaker, that it is not connected to the neutral leads from other HPFI circuit breakers. The neutral lead must be only associated with that specific circuit breaker. Additionally it is important that the fixtures are connected correctly to the ground (earth) to ensure that the power leakage is able to run off.
6
Cyclo user manual
Page 7
The cable for AC power is passed through one of the two 5 mm holes at the end of the fixture. These are sealed with plastic an d you will need to break a hole in one of the them.
A clamp connector can be found at each end of the fixture. One is used to supply power and dimmer control to the fixture and the other is used to send power and dimmer control onwards to other fixtures in a series. The number of terminals present on each clamp connector is dependent on the Cyclo model.
Use the three terminals not shaded in grey to connect A C power - L live, or positive), N (neutral) and ground (or earth).
1
2
L
N
4
3
AC power
connections
Be sure to refer and comply with local standards. Some common AC cable configuratio ns are:
Wire (EU) Wire (US) Pin Marking
brown black live “L”
blue white neutral “N”
yellow/green green ground
If the fixture is being wired in series with other Cyclo fixtures of the same type, perform these steps at the other end of the fixture to connect it to the next fixture.
Cyclo user manual
7
Page 8
DIMMER CONTROL FROM A 516-II DMX
TO 0-10 V CONVERTER
Note: If you apply power to a Cyclo fixture that is not connected to a
dimmer then it will operate at full power.
The 516-II DMX to 0-10 V Converter has 16 analog outputs for connecting 0-10 V analog devices. For independent control, a Cyclo 02 requires two of these outputs (one per ballast), a Cyclo 03 requires three outputs, and a Cyclo 04 requires four outputs.
A maximum of 10 Cyclos (ballasts) of the same model can be wired in series to the same analog output/s on the 516-II DMX to 0-10 V Conver ter. Each Cyclo in the series will mimic the behavior of the others. Do not wire different Cyclo models in series to the same analog outputs.
This means that a single 516-II DMX to 0-10 V Converter can provide independent control of up to 8 groups of 10 Cyclo 02s (80 fixtures), 5 groups of 10 Cyclo 03s (50 fixtures), 4 groups of 10 Cyclo 04s (40 fixtures), or a combination of groups of up to 10 of each model.
Each output on the 516-II DMX to 0-10 V Converter is connected to both a 5-pin DIN socket and the 25-pin D-SUB socket. For the purposes of wiring, the pin configuration can be found on the rear panel of the 516 controller.
Wiring the 5-pin DIN connector
Use a 5-pin DIN connector to connect the controller to a series of one of more Cyclos of the same type. (The controller has 4 5-pin DIN outputs enabling control of up to four parallel series of Cyclo fixtures.)
Always connect the ground wire to pin 2, and control leads to the other pins (between 2-4 depending on the number of tubes in the Cyclo that is being connected). The pin number of each output is shown on the rear panel. Make a note of which colored leads are connected to which channels as well as which colored wire is the ground wire.
Note: Connections can be tested without a controller by setting all
pins on the converter’s DIP-switch to the off position and then applying power to the conver ter and the devices.
3
5
4
2
1
8
Cyclo user manual
Page 9
Connecting the dimmer control cable to a Cyclo fixture
The cable for dimmer control is passed through one of the two 5 mm holes at the end of the fixture. These are sealed with pla stic and you will need to break a hole in one of the them.
A clamp connector can be found at each end of the fixture. One is used to supply power and dimmer control to the fixture and the other is used to send power and dimmer control onwards to other fixtures in a series. The number of terminals present on each clamp connector is dependent on the Cyclo model.
2
Use the numbered terminals to connect dimmer control. (Note that there are fewer connectors on Cyclo models with fewer than four tubes.) Connect the ground (earth) lead to the - terminal. Connect the other leads to the appropriate connectors. Notes that there are two connectors at each position and that you can use either one of these.
1
4
3
Dimmer
connectors
L
N
The internal wir ing in the fixture carries the di mmer control through the fixture. Holes are supplied at both ends for input and output cables. If the fixture is being wired in ser ies with other Cyclo fixtures of th e same type, perform these steps at the other end of the fixture to connect dimmer control to the next fixture.
Note: You can simultaneously control dimming on multiple Cyclo
fixtures of the same type by wiring them in series. However, each analog output from the 516 Converter supplies 20mA. This means that a maximum of 10 Cyclos (ballasts) in series can be controlled from each 516 Converter channel. Each ballast requires 1.5-2 mA.
If you are connecting multiple Cyclo fixtures in series that the length and diameter of the control (dimmer) cabling must be dimensioned so that the voltage drop over the cabling is less than 0.5 volts.
Cyclo user manual
9
Page 10
FLUORESCENT TUBES
Burning in new tubes
In order to obtain the full 200 00 hour life time, new fluorescent tubes must be burned in for 100 hundred hours at full power (10 volts).
Identifying tube positions
Tube positions are identified in the Cyclo 03 and Cyclo 04 as follows:
Marking in fixture Marking on tube Color Reference illustration
R OSRAM 28/60 Red G OSRAM 28/66 Green B OSRAM 28/67 Blue
2700K white 4000K white 6000K white
None
OSRAM 28/827 OSRAM 28/840 OSRAM 28/860
CLEANING
We recommend that you clean the dust cover with a damp cloth.
B
G
R
Page 11
S
PECIFICATIONS
PHYSICAL
L x W x H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1190 x 63 x 88 mm (50.1 x 2.7 x 3.7 in)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.8 kg (8.4 lbs)
Shipping dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 1210 x 115 x 95 mm, (51 x 4.8 x 4 in)
Shipping weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.1 kg (9.1 lbs)
Fixture color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . white (NCS 0402-G06-Y)
INSTALLATION
Orientation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .any
Minimum free space around fixture when installed . . . . . . . . . . . . . . . . . . . 25 mm (1 inch)
SOURCE
Approved lamp type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OSRAM T5 FH 28 watt tubes
Light source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T5 tubes (2x28W)
Expected lamp life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20000 hours
POWER
AC power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198V-254V,50/60hz
Dimmer control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , 1-10V control
Maximum power and current @ 230 V / 50 Hz . . . . . . . . . . . . . . . . . . . . . 0.28 A / 64 watts
- C
YCLO
02
THERMAL
Maximum ambient temperature (Ta). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40° C (104° F)
DYNAMIC EFFECTS
Color temperature control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2700K up to 6000K
Independent dimming of each tube via 516 Converter
CONTROL (VIA 516 CONVERTER)
Number of independently controllable dimming channels . . . . . . . . . . . . . . . . . . . . . . . . .16
Channels required per independently controlled Cyclo 02 group . . . . . . . . . . . . . . . . . . . . .2
Channels required per independently controlled Cyclo 03 group . . . . . . . . . . . . . . . . . . . . .3
Channels required per independently controlled Cyclo 04 group . . . . . . . . . . . . . . . . . . . . .4
Number of Cyclos per group (fixtures wired in series). . . . . . . . . .1-10 (of the same model)
ORDERING INFORMATION
Cyclo 02. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90550020
INCLUDED ITEMS
Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OSRAM T5 FH28W/827 (2700K) (white)
Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OSRAM T5 FH28W/860 (6000K) (white)
User manual
ACCESSORIES
Martin 516 II DMX to 0-10V Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90758225
Page 12
S
PECIFICATIONS
PHYSICAL
L x W x H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1190 x 81 x 88 mm (50.1 x 3.4 x 3.7 in)
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7 kg (10.4 lbs)
Shipping dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 1210 x 115 x 95 mm, (51 x 4.8 x 4 in)
Shipping weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 kg (11 lbs)
Fixture color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . white (NCS 0402-G06-Y)
INSTALLATION
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . any
Minimum free space around fixture when installed. . . . . . . . . . . . . . . . . . . . 25 mm (1 inch)
SOURCE
Approved lamp type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OSRAM T5 FH 28 watt tubes
Light source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T5 tubes (3x28W)
Expected lamp life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20000 hours
POWER
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198 V - 254 V, 50 / 60 Hz
Dimmer control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , 1-10V control
Maximum power and current @ 230 V / 50 Hz. . . . . . . . . . . . . . . . . . . . . .0.42 A / 96 watts
- C
YCLO
03
THERMAL
Maximum ambient temperature (Ta) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40° C (104° F)
DYNAMIC EFFECTS
Dimmable tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Red, green and blue
Independent dimming of each tube via 516 Converter
CONTROL (VIA 516 CONVERTER)
Number of independently controllable dimming channels . . . . . . . . . . . . . . . . . . . . . . . . 16
Channels required per independently controlled Cyclo 02 group . . . . . . . . . . . . . . . . . . . . 2
Channels required per independently controlled Cyclo 03 group . . . . . . . . . . . . . . . . . . . . 3
Channels required per independently controlled Cyclo 04 group . . . . . . . . . . . . . . . . . . . . 4
Number of Cyclos per group (fixtures wired in series) . . . . . . . . . 1-10 (of the same model)
ORDERING INFORMATION
Cyclo 03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P/N 90550010
INCLUDED ITEMS
Lamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OSRAM T5 FH28W/60 (red)
Lamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OSRAM T5 FH 28W/66 (green)
Lamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OSRAM T5 FH28W/67 (blue)
User manual
Page 13
ACCESSORIES
Martin 516 II DMX to 0-10V Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90758225
Page 14
S
PECIFICATIONS
PHYSICAL
L x W x H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1190 x 98 x 88 mm (50 x 4 x 3.7 in)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.5 kg (12.1 lbs)
Shipping dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 1210 x 115 x 95 mm, (51 x 4.8 x 4 in)
Shipping weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9 kg (13 lbs)
Fixture color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . white (NCS 0402-G06-Y)
INSTALLATION
Orientation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .any
Minimum free space around fixture when installed . . . . . . . . . . . . . . . . . . . 25 mm (1 inch)
SOURCE
Approved lamp type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OSRAM T5 FH 28 watt tubes
Light source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T5 tubes (3x28W)
Expected lamp life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20000 hours
POWER
AC power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 V - 254 V, 50 / 60 Hz
Dimmer control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , 1-10V control
Maximum power and current @ 230 V / 50 Hz . . . . . . . . . . . . . . . . . . . . 0.56 A / 128 watts
- C
YCLO
04
THERMAL
Maximum ambient temperature (Ta). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40° C (104° F)
DYNAMIC EFFECTS
Dimmable tubes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Red, green, blue and white
Independent dimming of each tube via 516 Converter
CONTROL (VIA 516 CONVERTER)
Number of independently controllable dimming channels . . . . . . . . . . . . . . . . . . . . . . . . .16
Channels required per independently controlled Cyclo 02 group . . . . . . . . . . . . . . . . . . . . .2
Channels required per independently controlled Cyclo 03 group . . . . . . . . . . . . . . . . . . . . .3
Channels required per independently controlled Cyclo 04 group . . . . . . . . . . . . . . . . . . . . .4
Number of Cyclos per group (fixtures wired in series). . . . . . . . . .1-10 (of the same model)
ORDERING INFORMATION
Cyclo 04. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90550000
INCLUDED ITEMS
Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OSRAM T5 FH28W/60 (red)
Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OSRAM T5 FH 28W/66 (green)
Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OSRAM T5 FH28W/67 (blue)
Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OSRAM T5 FH28W/840 (white)
User manual
Page 15
ACCESSORIES
Martin 516 II DMX to 0-10V Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P/N 90758225
Page 16
www.martin-architectural.com Olof Palmes Allé 18 8200 Aarhus N Denmark
Tel: +45 8740 0000
Fax +45 8740 0010
Loading...