Martin VDO Atomic Dot User Manual [EN]

Page 1
VDO Atomic Dot
User Guide
Page 2
Table of contents
Dimensions ...................................................................................................3
Before using the product for the first time..............................................10
Fixture location ......................................................................................13
Ways of mounting the fixture .................................................................13
Mounting the fixture on a truss using the hanging bracket....................14
Mounting the fixture on a truss using direct clamp ................................15
Interlocking multiple fixtures ..................................................................15
Safety bonds..........................................................................................18
Mounting the junction box......................................................................18
Safety limits for connecting devices ......................................................19
AC power connection to Junction Box...................................................19
Data connection to Junction Box ...........................................................19
PDE connections between fixtures........................................................22
Setting options by RDM .........................................................................23
Scanning for RDM devices on the data link...........................................23
Getting status and setting options by RDM ...........................................23
RDM.......................................................................................................24
Thermal regulation.................................................................................25
Video display using P3 ..........................................................................25
DMX control ...........................................................................................25
Status LED.............................................................................................26
Pushbutton functions .............................................................................26
Installing optical accessories .................................................................27
Cleaning.................................................................................................28
LED performance...................................................................................28
Installing new software ..........................................................................28
DMX mode 1 channel ............................................................................29
DMX mode 3 channel ............................................................................29
DMX mode 4 channel ............................................................................30
DMX mode Basic ...................................................................................30
DMX mode Extended.............................................................................34
FX Table ................................................................................................41
Page 3

Dimensions

Fixture dimensions
241.6
175.2
All dimensions are given in millimeters.
146
Page 4
Junction Box dimensions
129.1
106.5
All dimensions are given in millimeters.
50.5
Page 5
Coupler (for interlocking two fixtures)
44
37
33
21
Half Coupler (for attaching to truss)
50.8
41
49
90
140
85
33
41
18
49
All dimensions are given in millimeters.
Page 6
Interlock Adapter (for attaching to microphone stand)
41 33
48
49
28
Pivot coupler (for interlocking two fixtures at an angle)
44
53
41
4
23
15.0M8x1.25-6H
3/8-16UNC
15.0
7.5
18.5
187
90
All dimensions are given in millimeters.
© 2012-2019 HARMAN PROFESSIONAL DENMARK ApS. All rights reserved. Features, specifications and appearance are subject to change without notice. HARMAN PROFESSIONAL DENMARK ApS and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. Martin is a registered trademark of HARMAN PROFESSIONAL DENMARK ApS registered in the United States and/or other countries.
HARMAN PROFESSIONAL DENMARK ApS • Olof Palmes Alle 44 • 8200 Aarhus N • Denmark
HARMAN PROFESSIONAL SOLUTIONS U.S. • 8500 Balboa Blvd. • Northridge • CA 91329 • USA
www.martin.com
VDO Atomic Dot User Guide Revision A
Page 7

Safety information

WARNING!
Read the safety precautions in this manual before installing, operating or
The following symbols are used to identify important safety information on the product and in this manual:
Warning!
Safety
hazard. Risk
of severe
injury or
death.
VDO Atomic Dot CLD only: Warning! Risk Group 2 product according to EN 62471 and IEC/TR 62778. Possibly hazardous radiation emitted from this product. May be harmful to the eyes. Do not stare at operating lamp and do not view the light output with optical instruments or any device that may concentrate the beam.
This lighting fixture is for professional use only and must be installed by a qualified technician. It is not for household use. It presents risks of severe injury or death due to fire hazards, electric shock and falls. It can create a fire hazard or a risk of eye injury if the safety precautions below are not followed.
Warning!
Powerful
light
emission.
Risk of eye
injury.
Warning!
See user
manual for
important
information.
servicing this product.
Warning!
Hazardous
voltage. Risk
of lethal or
safety
severe
electric
shock.
Warning!
Fire hazard.
Warning!
Hot surfaces.
Install, operate and service Martin® products only as directed in their user manuals, or you may create a safety hazard or cause damage that is not covered by product warranties. Follow the safety precautions listed below and observe all warnings in this manual and printed on the product. Keep this user manual for future use.
For the latest user documentation and other information about this and all Martin® products, please visit the Martin® website at http://www.martin.com
If you have a please contact your Martin® distributor (see www.martin.com/distributors for details) or in the USA on 1-844-776-4899.
Respect all locally applicable laws, codes and regulations when installing, operating or servicing the fixture.
Protection from electric shock
Ensure that the fixture is electrically connected to ground (earth).
Disconnect the fixture from AC power when not in use.
Do not open the fixture or remove any cover. Refer any service operation not described in this manual to an authorized Martin Service partner.
Shut down power to the entire installation at the main power distribution board and lock out power before carrying out any installation or maintenance work.
ny questions about how to install, operate or service the fixture safely,