Martin VDO Atomic Dot User Manual

VDO Atomic Dot
User Guide
Table of contents
Safety information .........................................................................................7
Introduction .................................................................................................10
Before using the product for the first time..............................................10
Fixture overview..........................................................................................11
Junction box overview.................................................................................12
Physical installation.....................................................................................13
Fixture location ......................................................................................13
Ways of mounting the fixture .................................................................13
Mounting the fixture on a truss using the hanging bracket....................14
Mounting the fixture on a truss using direct clamp ................................15
Interlocking multiple fixtures ..................................................................15
Safety bonds..........................................................................................18
Mounting the junction box......................................................................18
AC power and data connection...................................................................19
Safety limits for connecting devices ......................................................19
AC power connection to Junction Box...................................................19
Data connection to Junction Box ...........................................................19
PDE connections between fixtures........................................................22
System Setup..............................................................................................23
Setting options by RDM .........................................................................23
Scanning for RDM devices on the data link...........................................23
Getting status and setting options by RDM ...........................................23
RDM.......................................................................................................24
Using the VDO Atomic Dot .........................................................................25
Thermal regulation.................................................................................25
Video display using P3 ..........................................................................25
DMX control ...........................................................................................25
Status LED.............................................................................................26
Pushbutton functions .............................................................................26
Maintenance ...............................................................................................27
Installing optical accessories .................................................................27
Cleaning.................................................................................................28
LED performance...................................................................................28
Installing new software ..........................................................................28
DMX protocol ..............................................................................................29
DMX mode 1 channel ............................................................................29
DMX mode 3 channel ............................................................................29
DMX mode 4 channel ............................................................................30
DMX mode Basic ...................................................................................30
DMX mode Extended.............................................................................34
FX Table ................................................................................................41
Troubleshooting ..........................................................................................44
Specifications..............................................................................................45
Dimensions
Fixture dimensions
175.2 146
241.6
All dimensions are given in millimeters.
Junction Box dimensions
129.1
50.5
106.5
All dimensions are given in millimeters.
Coupler (for interlocking two fixtures)
21
41
49
44
37
33
Half Coupler (for attaching to truss)
33
50.8
41
49
18
90
140
85
All dimensions are given in millimeters.
Interlock Adapter (for attaching to microphone stand)
41 33
28
18.5
15.0M8x1.25-6H
3/8-16UNC
15.0
7.5
49
48
23
Pivot coupler (for interlocking two fixtures at an angle)
44
90
187
53
41
4
© 2012-2019 HARMAN PROFESSIONAL DENMARK ApS. All rights reserved. Features, specifications and appearance are subject to change without notice. HARMAN PROFESSIONAL DENMARK ApS and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. Martin is a registered trademark of HARMAN PROFESSIONAL DENMARK ApS registered in the United States and/or other countries.
HARMAN PROFESSIONAL DENMARK ApS • Olof Palmes Alle 44 • 8200 Aarhus N • Denmark
HARMAN PROFESSIONAL SOLUTIONS U.S. • 8500 Balboa Blvd. • Northridge • CA 91329 • USA
www.martin.com
VDO Atomic Dot User Guide Revision A
All dimensions are given in millimeters.
Martin VDO Atomic Dot user guide 7
Safety information
WARNING!
Read the safety precautions in this manual before installing, operating or
servicing this product.
The following symbols are used to identify important safety information on the product and in this manual:
Warning!
Safety
hazard. Risk
of severe
injury or
death.
Warning!
Powerful
light
emission.
Risk of eye
injury.
Warning!
See user
manual for
important
safety
information.
Warning!
Hazardous
voltage. Risk
of lethal or
severe
electric
shock.
Warning!
Fire hazard.
Warning!
Hot surfaces.
VDO Atomic Dot CLD only: Warning! Risk Group 2 product according to EN 62471 and IEC/TR 62778. Possibly hazardous radiation emitted from this product. May be harmful to the eyes. Do not stare at operating lamp and do not view the light output with optical instruments or any device that may concentrate the beam.
This lighting fixture is for professional use only and must be installed by a qualified technician. It is not for household use. It presents risks of severe injury or death due to fire hazards, electric shock and falls. It can create a fire hazard or a risk of eye injury if the safety precautions below are not followed.
Install, operate and service Martin® products only as directed in their user manuals, or you may create a safety hazard or cause damage that is not covered by product warranties. Follow the safety precautions listed below and observe all warnings in this manual and printed on the product. Keep this user manual for future use.
For the latest user documentation and other information about this and all Martin® products, please visit the Martin® website at http://www.martin.com
If you have a
ny questions about how to install, operate or service the fixture safely, please contact your Martin® distributor (see www.martin.com/distributors for details) or in the USA on 1-844-776-4899.
Respect all locally applicable laws, codes and regulations when installing, operating or servicing the fixture.
Protection from electric shock
Ensure that the fixture is electrically connected to ground (earth).
Disconnect the fixture from AC power when not in use.
Do not open the fixture or remove any cover. Refer any service operation not described in this manual to an authorized Martin Service partner.
Shut down power to the entire installation at the main power distribution board and lock out power before carrying out any installation or maintenance work.
8 Martin VDO Atomic Dot user guide
Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault (earth-fault) protection.
Isolate the fixture from power immediately if any seal, cover, cable, or other component is damaged, defective, deformed or showing signs of overheating. Do not reapply power until repairs have been completed
Before using the fixture, check that all power distribution equipment and cables are in perfect condition and are of suitable type for the location (including water, pollution, temperature and UV resistance).
Do not immerse the fixture in water or any other fluid, or install it in a location where flooding may occur.
The light source contained in this luminaire shall only be replaced by the manufacturer or their service agent or a similar qualified person.
When connecting multiple fixtures in a daisy chain, observe the safety limits in section “Safety limits for connecting devices” on page 19.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
The surface of the fixture can reach up to 55° C (131° F) if the fixture is operated at the maximum permitted ambient temperature. Allow the fixture to cool for at least 5 minutes before handling.
Install the fixture on a non-combustible surface (brick, concrete, plaster etc.) only.
Do not aim the fixture towards combustible materials (fabric, wood, paper etc.) that are within 50 cm (19 in.) of the fixture.
Keep the fixture well away from flammable materials (volatile liquids etc.).
Ensure that there is free and unobstructed airflow around the fixture.
Allow at least 0.1 m (4 in.) free space around the fixture.
Do not attempt to bypass thermostatic switches or fuses.
Do not modify the fixture in any way not described in this manual or install other than genuine Martin® parts. Do not stick filters, masks or other materials onto any lens or other optical component. Use only accessories approved by Martin® to modify the light beam.
Protection from eye injury
VDO Atomic Dot CLD only: Warning! Risk Group 2 product according to EN 62471 and IEC/TR 62778.
Do not look directly into the product’s light output.
Do not look at operating lamp. Eye injury may result.
Do not look at the light output with magnifiers, telescopes, binoculars or similar optical instruments that may concentrate the light output.
Ensure that persons are not looking directly into the front of the fixture when the product lights up suddenly. This can happen when power is applied, when the product receives a DMX signal, or when certain control menu items are selected.
To minimize the risk of eye irritation or injury, disconnect the fixture from power at all times when the fixture is not in use and provide well-lit conditions to reduce the pupil diameter of anyone working on or near the fixture.
The VDO Atomic Dot CLD fixture fixtures fall into the following risk groups according to EN 62471 and IEC/TR 62778 at the distances indicated below.
Martin VDO Atomic Dot user guide 9
RISK GROUP
DO NOT
USE
2
RISK GROUP
1
1.0 m
0.2 m
(39.4 in.)
(7.9 in.)
9.6 m
(31.5 ft.)
RISK GROUP
EXEMPT
The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 1 m is not expected.
Protection from injury
Fasten the fixture securely to a fixed surface or structure when in use. The fixture is not portable when installed.
Ensure that all supporting structures, surfaces, fasteners and lifting equipment can bear the weight of all the devices they are intended to support plus an adequate safety margin, and that they conform to local building and safety regulations.
Ensure that any accessory such as gel frames, gobo holders are securely fastened.
Block access below the work area and work from a stable platform whenever installing, setting, adjusting, or cleaning the fixture.
Do not operate the fixture with missing or damaged covers, shields or any optical component.
If an operating problem occurs, stop using the fixture immediately and disconnect it from power. Do not attempt to use a fixture that is obviously damaged.
10 Martin VDO Atomic Dot user guide
Introduction
Thank you for selecting the Martin VDO Atomic Dot product. This versatile product can be used for a wide variety of effects:
x Compact strobe fixture x Compact blinder fixture x Compact beam fixture x Compact video pixel with 16 LEDs of individual control
The VDO Atomic Dot is available in two variants:
x A WRM variant featuring a primary white LED with a color temperature of 2700K x A CLD variant featuring a primary white LED with a color temperature of 5700K
Both variants also contain 16 individually controllable RGB LEDs for additional Aura effects behind the front-lens.
As the fixture is fully IP65-rated, it is suitable for both indoor and outdoor applications.
Multiple VDO Atomic Dots can be combined together into battens and arrays to create large visual effects, by using the integrated interconnecting mechanics.
The VDO Atomic Dot is compatible with a large variety of lighting and video control protocols, allowing the fixture to be controlled in the most suitable way:
x DMX/RDM x Art-Net x sACN x P3
Power and data is supplied to the fixture via a hybrid cable with hybrid connector that carries power, DMX and Ethernet. This allows many fixtures to be daisy-chained very easily, without requiring multiple cables between them.
The start of a daisy-chain is made at a Junction Box that takes standard Power, DMX and Ethernet inputs and merges them into the PDE hybrid connector.
The front of the VDO Atomic Dot features an industry-standard PAR30-sized holder, allowing installation of standard accessories such as diffusers, color filters and barndoors.
Before using the product for the first time
1. Read ‘Safety information’ on page 7 before installing, operating or servicing the fixture.
2. Unpack and ensure that there is no transportation damage before using the fixture. Do not attempt to operate a damaged fixture.
3. Before operating, ensure that the voltage and frequency of the power supply match the power requirements of the fixture.
4. Obtain a power cable fitted with Neutrik powerCON TRUE1 connector. Cables are available from Martin (see Accessories list on page 45).
5.
Check the support pages on the Martin® website at www.martin.com for the most recent user documentation and technical information about the fixture. Martin® user manual revisions are identified by the revision letter at the bottom of the inside cover.
Martin VDO Atomic Dot user guide 11
Fixture overview
1
2
6
7
5
8
9
3
4
5
1 – Hanging bracket (can be taken off)
2 – PAR30 sized holder
3 – Status LED
4 – Test / Reset button
5 – Interlock slots for interlock accessories (4 slots, one on each side of fixture)
6 – Thru connector (chassis mount, with sealing cap)
7 – Safety cable attachment point
8 – Input cable with connector
9 – M8 holes for hanging bracket attachment, maximum bolt length 15 mm (4 holes, one on
each side of fixture). May also be used for mounting fixture if standard interlock accessories are not suitable.
12 Martin VDO Atomic Dot user guide
Junction box overview
5
3
4
1
2
Underside view
6
1 – Neutrik PowerCON TRUE1 input
2 – Hybrid PDE output connector
3 – Neutrik etherCON input
4 – Neutrik XLR5 DMX input
5 – Holes for mounting to wall / surface
6 – M10 hole for adding clamp (on underside of box)
Martin VDO Atomic Dot user guide 13
Physical installation
Warning! Read ‘Safety information’ on page 7 before installing the fixture.
Wa
rning! The safety and suitability of lifting equipment, installation location, anchoring method, mounting hardware and electrical installation are the responsibility of the installer. All local safety regulations and legal requirements must be observed when installing and connecting the VDO Atomic Dot fixture and Junction Box. Installation must be carried out by qualified professionals only.
Contact your Martin supplier for assistance if you have any questions about how to install this product safely.
Fixture location
The VDO Atomic Dot fixture and Junction Box is fully IP65 rated and may be used indoors or in a temporary outdoor location.
Observe the following limitations in selecting a location:
x Respect the limitations listed under Safety information’ on page 7. x Do not lo
cate the fixture in an unventilated space.
Ways of mounting the fixture
Warning! All fasteners used to mount VDO Atomic Dot fixtures or arrays of
fixtures must be strong enough to hold the fixtures safely. Install a washer directly under the head of each fastener when anchoring the mounting bracket to the installation surface.
The fixture has a number of mounting options:
x Via the hanging bracket to a truss or surface x A VDO Atomic Dot Half Coupler may be attached directly to one of the interlock slots on
the fixture (without the hanging bracket)
x Multiple fixtures may be interlocked together using the slide-in Interlock Coupler. A
maximum of 16 fixtures may be interlocked in a column. When interlocking fixtures horizontally, a rigging clamp must be used every 3
rd
fixture to support the array (so a
maximum of 2 unsupported fixtures between each supported one)
x A Pivot Interlock Coupler is available which couples fixtures at any multiple of 15 degrees.
This allows circles or other shapes of fixtures to be created.
x An Interlock Adaptor is available which attaches to one of the interlock slots enabling you
to mount a single VDO Atomic Dot on a microphone stand with standard 5/8 in. thread.
x Safety bonds must be fitted to each fixture, even when fixtures are interlocked, using the
safety bond attachment point on the rear.
14 Martin VDO Atomic Dot user guide
Mounting the fixture on a truss using the hanging bracket
The fixture or array of fixtures can be clamped to a truss or similar rigging structure using the hanging bracket which allows adjustment of the fixture angle. Use a suitable rigging clamps such as a G-clamp or a half-coupler clamp fastened to the hanging bracket.
To clamp the fixture to a truss:
1. Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it.
2. Block access under the work area.
3. Bolt a rigging clamp securely to the hanging bracket. The bolts used must be M12, grade 8.8 steel minimum, and fastened with a self-locking nut.
4. Working from a stable platform, mount the fixture on the truss and fasten the rigging clamp onto the truss.
5. Attach a safety bond to the fixture and loop around a fixed point.
Martin VDO Atomic Dot user guide 15
Mounting the fixture on a truss using direct clamp
The VDO Atomic Dot Half Coupler may be directly mounted to the fixture or array of fixtures using one of the interlock slots on any side.
To rig using a directly attached clamp:
1. Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it.
2. Block access under the work area.
3. Slide VDO Atomic Dot Half Couplers into the fixture interlock slot on one or more fixtures as required.
4. Working from a stable platform, lift the fixture(s) to the truss and fasten the half coupler clamp onto the truss.
5. Attach a safety bond to the fixture and loop around a fixed point. Each fixture must have an individual safety bond even when interlocked into an array.
Interlocking multiple fixtures
Multiple fixtures may be interlocked on any side using the slide-in interlock coupler to form arrays of any shape.
Loading...
+ 35 hidden pages