52 TripixTM Series user manual
Construction
Tripix 300, 1200 and Wash Fixtures
Housing ........................................................................................ Aluminum
Finish .................................................................................... Clear anodized
Front cover ........................................................................................ PMMA
IP rating ............................................................................................... IP 66
Tripix Power
Housing ................................................................................................ Steel
Finish ........................................................................... Grey powder-coated
IP rating ............................................................................................... IP 20
Tripix Power IP66
Housing ........................................................................................ Aluminum
Finish ................................................................................... Clear Anodized
IP rating ............................................................................................... IP 66
Installation
Orientation .............................................................................................. Any
Vertical aiming ................................................................................... +/- 95°
Mounting points ...................... mounting brackets or 35 mm DIN top-hat rail
Maximum number of fixtures connected per Tripix Power
Tripix 300 .................................................................................................. 24
Tripix 1200 .................................................................................................. 6
Tripix Wash ................................................................................................ 6
Mixture of Tripix 300, 1200 and Wash
(Wash counts as 1200) ....................... 7.2 m (23.6 ft.)
Maximum number of fixtures connected per Tripix Power IP66
Tripix 300 .................................................................................................. 12
Tripix 1200 .................................................................................................. 3
Tripix Wash ................................................................................................ 3
Mixture of Tripix 300, 1200 and Wash
(Wash counts as 1200) ....................... 3.6 m (11.8 ft.)
Connections
AC power input, Tripix Power ................................... Male (C14) IEC socket
AC power input, Tripix Power IP66 ................... Hard-wired, screw terminals
Tripix fixtures interconnection, power and data .................. 13 pin DIN, IP66