Martin RUSH MH 6 Wash CT User Manual

Page 1
RUSH™ MH 6 Wash CT
User Manual
Page 2
© 2016 Martin Professional™ ApS. Information subject to change without notice. Martin Professional™ and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual. Martin™, Harman™, RUSH™ and all other trademarks in this document pertaining to services or products by Martin Professional™ or its affiliates and subsidiaries are registered as the property of Harman International Industries.
Martin Professional • Olof Palmes Allé 18 • 8200 Aarhus N • Denmark • www.martin.com
Manual: Revision B
Page 3
Table of contents
Safety information .............................................................................................. 4
Introduction ........................................................................................................ 9
Before using the product for the first time ...................................................... 9
Physical installation ......................................................................................... 10
Fastening the fixture to a flat surface ........................................................... 10
Mounting the fixture on a truss ..................................................................... 10
AC power ......................................................................................................... 12
Linking fixtures to power in a chain .............................................................. 13
Fixture overview ............................................................................................... 14
Control data link ............................................................................................... 15
Tips for reliable data transmission ............................................................... 15
Connecting the data link ............................................................................... 15
Fixture setup .................................................................................................... 16
Using the control menus .............................................................................. 16
DMX addressing ........................................................................................... 16
Blackout or hold if DMX signal stops............................................................ 16
Dimming curves ............................................................................................ 17
Dimmer speed .............................................................................................. 17
Pan/tilt inversion ........................................................................................... 18
Backlight ....................................................................................................... 18
Temperature ................................................................................................. 18
Fixture time ................................................................................................... 18
Auto test ....................................................................................................... 18
Manual test ................................................................................................... 19
Reset ............................................................................................................ 19
Home position (offsets) adjustment.............................................................. 19
Effects .............................................................................................................. 20
Pan and tilt ................................................................................................... 20
Strobe effects ............................................................................................... 20
Electronic dimming ....................................................................................... 20
Color temperature ........................................................................................ 20
Zoom ............................................................................................................ 20
Maintenance .................................................................................................... 21
Cleaning ....................................................................................................... 21
Replacing the primary fuse .......................................................................... 22
Service and repairs ...................................................................................... 22
DMX protocol ................................................................................................... 23
Control menus .................................................................................................. 25
Troubleshooting ............................................................................................... 27
Specifications ................................................................................................... 28
Page 4
4 RUSH™ MH 6 Wash CT User Manual
Safety information
WARNING!
Read the safety precautions in this manual before installing,
operating or servicing this product.
The following symbols are used to identify important safety information on the product and in this manual:
Warning!
Safety hazard. Risk of severe
injury or death.
Warning!
Powerful light
emission. Risk
of eye injury.
Warning!
See user
manual for
important
safety
information.
Warning!
Hazardous
voltage. Risk
of lethal or
severe electric
shock.
Warning!
Hot surfaces
and fire
hazard.
Warning! Risk Group 2 product according to EN 62471. Possibly hazardous radiation emitted from this product. May be harmful to the eyes. Do not stare at operating lamp and do not view the light output with optical instruments or any device that may concentrate the beam.
This lighting fixture is for professional use only and must be installed by a qualified technician. It is not for household use. It presents risks of severe injury or death due to fire hazards, electric shock and falls. It produces a powerful, concentrated beam of light that can create a fire hazard or a risk of eye injury if the safety precautions below are not followed.
Install, operate and service Martin™ products only as directed in their user manuals, or you may create a safety hazard or cause damage that is not covered by product warranties.
Follow the safety precautions listed below and observe all warnings in this manual and printed on the product. Keep this user manual for future use.
For the latest user documentation and other information for this and all Martin™ products, please visit the Martin website at http://www.martin.com
Page 5
RUSH™ MH 6 Wash CT User Manual 5
If you have any questions about how to install, operate or service the fixture safely, please contact your Martin™ distributor (see www.martin.com/distributors for details) or call the Martin™ 24-hour service hotline on +45 8740 0000, or in the USA on 1-888-tech-180.
Respect all locally applicable laws, codes and regulations when installing, operating or servicing the fixture.
Protection from electric shock
Do not expose the fixture to rain or moisture. Disconnect the fixture from AC power before carrying out any
installation or maintenance work and when the fixture is not in use.
Ensure that the fixture is electrically connected to ground (earth).
Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixture can easily be disconnected from power.
Replace defective fuses with ones of the specified type and rating only.
Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or other component is damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power until repairs have been completed
Before using the fixture, check that all power distribution equipment and cables are in perfect condition and rated for the electrical requirements of all connected devices.
Use only Neutrik PowerCon cable connectors to connect to the fixture’s power sockets.
Do not connect devices to power in a chain that will exceed the electrical ratings of any cable or connector used in the chain.
The supplied power input cable is rated 6 A and can safely supply only one fixture with mains power. Do not connect any device to the fixture’s MAINS OUT connector when using this
Page 6
6 RUSH™ MH 6 Wash CT User Manual
cable. If you replace this cable and also use the replacement cable to supply only one fixture with mains power, the replacement cable must also be rated 6 A minimum, have three conductors 18 AWG or 0.75 mm² minimum conductor size, have an outer cable diameter of 6 - 15 mm (0.2 - 0.6 in.) and be temperature-rated to suit the application. In the USA and Canada the cable must be UL listed, type SJT or equivalent. In the EU the cable must be type H05VV-F or equivalent.
To connect fixtures to mains power in a chain, you must first obtain 14 AWG or 1.5 mm
2
power input and throughput cables that are 16 A rated and temperature-rated to suit the application. In the USA and Canada the cables must be UL­listed, type SJT or equivalent. In the EU the cables must be type H05VV-F or equivalent. Suitable cables with Neutrik PowerCon connectors are available from Martin™ (see ‘Accessories’ on page 30). If you use these cables, you can connect fixtures to power in a linked chain, MAINS OUT throughput socket to MAINS IN input socket, but do not link more than:
eight (8) RUSH™ MH 6 Wash CT fixtures in total at 100-
120 V, or
fourteen (14) RUSH™ MH 6 Wash CT fixtures in total at
200-240 V.
The voltage and frequency at the MAINS OUT socket are the same as the voltage and frequency applied to the MAINS IN socket. Only connect devices to the MAINS OUT socket that accept this voltage and frequency.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (T
a
)
exceeds 40° C (104° F). The surface of the product casing can reach up to 50° C
(122° F) during operation. Avoid contact by persons and materials. Allow the fixture to cool for at least 10 minutes before handling.
Keep flammable materials well away from the fixture. Keep all combustible materials (e.g. fabric, wood, paper) at least 100 mm (4 in.) away from the fixture head.
Ensure that there is free and unobstructed airflow around the fixture. Provide a minimum clearance of 100 mm (4 in.) around fans and air vents.
Page 7
RUSH™ MH 6 Wash CT User Manual 7
Do not illuminate surfaces within 200 mm (8 in.) of the fixture. Do not attempt to bypass thermostatic switches or fuses. Connect only other fixtures of the same type to the power
throughput sockets. Do not connect any other type of device to these sockets.
Do not stick filters, masks or other materials onto any optical component.
The fixture’s lenses can focus the sun’s rays inside the fixture, creating a risk of fire and damage. Do not expose the front of the fixture to sunlight or any other bright light source.
Protection from eye injury
The light from the LED lamp is possibly hazardous and may be harmful to the eyes. Do not stare directly into the product’s light output.
Do not look at the light output with magnifiers, telescopes, binoculars or similar optical instruments that may concentrate the light output.
Ensure that persons are not looking directly into the LEDs when the product lights up suddenly. This can happen when power is applied, when the product receives a DMX signal, or when certain control menu items are selected.
To minimize the risk of eye irritation or injury, disconnect the fixture from power at all times when the fixture is not in use, and provide well-lit conditions to reduce the pupil diameter of anyone working on or near the fixture.
Protection from injury
Fasten the fixture securely to a fixed surface or structure when in use. The fixture is not portable when installed.
Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the devices they support.
If suspending from a rigging structure, fasten the fixture to a rigging clamp. Do not use safety cables as the primary means of support.
If the fixture is installed in a location where it may cause injury or damage if it falls, install as directed in this manual a secondary attachment such as a safety cable that will hold the fixture if a primary attachment fails. The secondary attachment
Page 8
8 RUSH™ MH 6 Wash CT User Manual
must be approved by an official body such as TÜV as a safety attachment for the weight that it secures, must comply with EN 60598-2-17 Section 17.6.6 and must be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories.
Allow enough clearance around the head to ensure that it cannot collide with an object or another fixture when it moves.
Check that all external covers and rigging hardware are securely fastened.
Block access below the work area and work from a stable platform whenever installing, servicing or moving the fixture.
Do not operate the fixture with missing or damaged covers, shields or any optical component.
Do not lift or carry the fixture by its head. Support the fixture by its base only.
In the event of an operating problem, stop using the fixture immediately and disconnect it from power. Do not attempt to use a fixture that is obviously damaged.
Do not modify the fixture in any way not described in this manual or install other than genuine Martin™ parts.
Refer any service operation not described in this manual to a qualified technician.
Page 9
RUSH™ MH 6 Wash CT User Manual 9
Introduction
The RUSH™ MH 6 Wash CT is a fast, powerful, white-light moving head wash effect. It incorporates twelve long-life LEDs with two warm-white and two cold­white chips that enable mixing of white tones from 2700 K (warm white) to 7800 K (cold white). The fixture provides smooth electronic dimming, strobe effects, 540° of pan and 220° of tilt, and a one-tenth peak beam angle that can be varied from 10° to 60°. It can be controlled by any DMX-compliant controller. The rugged, lightweight and compact fixture is suitable for both touring and fixed installations.
The RUSH™ MH 6 Wash CT is supplied with this user manual, a 1.5 m (5 ft.) power cable (local power plug not included) and an omega-type mounting bracket for rigging clamp attachment.
Before using the product for the first time
1. Read ‘Safety information’ on page 4 before installing, operating or servicing the fixture.
2. Unpack and ensure that there is no transportation damage before using the fixture. Do not attempt to operate a damaged fixture.
3. If the fixture is not going to be hard-wired to a mains supply, install a local power plug (not supplied) to the end of the supplied power cable.
4. Before operating, ensure that the voltage and frequency of the power supply match the power requirements of the fixture.
5. Check the support pages on the Martin Professional website at www.martin.com for the most recent user documentation and technical information about the fixture. Martin™ user manual revisions are identified by the revision letter at the bottom of the inside cover.
Note that whenever AC power is applied to the fixture, it will reset all effects and functions to their home positions. Be prepared for the fixture head to move. A reset usually takes around 20 seconds.
Page 10
10 RUSH™ MH 6 Wash CT User Manual
Physical installation
Warning! Read ‘Safety information’ on page 4 before installing the fixture.
The fixture is designed for indoor use only and must be used in a dry location with adequate ventilation. Ensure that none of the fixture’s ventilation slots are blocked.
Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it where it can be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails.
Martin™ can supply safety cables and rigging clamps that are suitable for use with the fixture (see ‘Accessories’ on page 30).
Fastening the fixture to a flat surface
The fixture can be fastened to a hard, fixed, flat surface. Ensure that the surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment they will support.
Fasten the fixture securely to the surface. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.
Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging structure in any orientation. You must use a half-coupler clamp (see illustration on right) that completely encircles the truss chord.
To clamp the fixture to a truss:
1. Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it.
2. Block access under the work area.
3. The fixture is supplied with an omega-type bracket to which a rigging clamp can be attached. Bolt a rigging clamp securely to the bracket. The bolt used must be M12, grade 8.8 steel minimum, and fastened with a self-locking nut.
Page 11
RUSH™ MH 6 Wash CT User Manual 11
4. Fasten the omega bracket to the base of the fixture using the bracket’s quarter-turn fasteners. Turn quarter-turn fasteners a full 90° to lock them (see illustration on right).
5. Working from a stable platform, hang the fixture on the truss and fasten the rigging clamp onto the truss.
6. Secure the fixture with a safety cable as directed below.
7. Check that the head will not collide with other fixtures or objects.
Securing with a safety cable
Secure the fixture with a safety cable (or other secondary attachment) that is approved for the weight of the fixture so that the safety cable will hold the fixture if the primary attachment fails. See illustration on right. Loop the safety cable through the cutout in the fixture’s baseplate (arrowed) and around a secure anchoring point.
Martin™ can supply suitable safety cables and rigging clamps (see ‘Accessories’ on page
30).
Page 12
12 RUSH™ MH 6 Wash CT User Manual
AC power
Warning! Read ‘Safety information’ on page 4 before connecting the fixture to AC mains power.
Warning! The mains power input cable supplied with the fixture is rated 6 A and can supply only one fixture with mains power. Do not connect any device to the fixture’s MAINS OUT power throughput socket when using this input cable. If you want to connect other fixtures to the MAINS OUT socket, see ‘Linking fixtures to power in a chain’ on page 13.
For protection from electric shock, the fixture must be grounded (earthed). The power distribution circuit must be equipped with a fuse or circuit breaker and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power.
Do not insert or remove live Neutrik PowerCon connectors to apply or cut power, as this may cause arcing at the terminals that will damage the connectors.
Do not use an external dimming system to supply power to the fixture, as this may cause damage to the fixture that is not covered by the product warranty.
The fixture can be hard-wired to a building electrical installation if you want to install it permanently, or a power plug (not supplied) that is suitable for the local power outlets can be installed on the power cable.
If you install a power plug on the power cable, install a grounding type (earthed) plug with integral cable grip that is rated minimum 250 V, 6 A. Follow the plug manufacturer’s instructions and connect the wires in the power cable as shown in this table:
Live or L Neutral or N
Earth, Ground or
US system
Black White Green
EU system
Brown Blue Yellow/green
The fixture has an auto-ranging power supply that accepts AC mains power at 100-240 V at 50/60 Hz. Do not apply AC mains power at any other voltage or frequency to the fixture.
Page 13
RUSH™ MH 6 Wash CT User Manual 13
Linking fixtures to power in a chain
If you obtain a 14 AWG / 1.5 mm2 power input cable and 14 AWG / 1.5 mm2 throughput cables from Martin™ (see ‘Accessories’ on page 30), you can relay mains power from one fixture to another by connecting fixtures to power in a linked daisy-chain, MAINS OUT throughput socket to MAINS IN input socket, Using 14 AWG or 1.5 mm
2
cables from Martin™, you can link:
Maximum eight (8) RUSH™ MH 6 Wash CT fixtures in total at 100-120 V, or
Maximum fourteen (14) RUSH™ MH 6 Wash CT fixtures in total at 200- 240 V.
If you install a power plug on the 14 AWG / 1.5 mm
2
power cable, install a grounding type (earthed) plug with integral cable grip that is rated minimum 250 V, 16 A.
Page 14
14 RUSH™ MH 6 Wash CT User Manual
Fixture overview
1 – LEDs
The LEDs on the front of the base give the following indications:
POWER
Power on
DMX Valid DMX signal present
2 – Control buttons
MENU
Activate the menu mode functions, or
Return to the previous level of the menu
structure, or
Press and hold to exit the menus
DOWN Go down a menu branch
UP Go up a menu branch
ENTER Confirm the selected function
3 – Display
4, 5 – AC mains power input / output
Use the blue Neutrik PowerCon socket to connect the fixture to mains power. Warning! The white Neutrik PowerCon socket can be used to supply power to other fixtures only if you respect the safety precautions given in this manual (see ‘Safety information’ on page 4).
6 – Primary (mains power) fuse
The T 3.15 A primary fuse (F1) is located inside the fuse holder.
7-10 – DMX input/output
3 and 5-pin XLR sockets are provided for DMX input and output (throughput).
Page 15
RUSH™ MH 6 Wash CT User Manual 15
Control data link
A DMX 512 data link is required in order to control the fixture via DMX. The fixture has 3-pin and 5-pin XLR connectors for DMX data input and output.
Up to 32 devices can be linked together on a single daisy chain. The total number of fixtures in one 512-channel DMX universe is limited by the number of DMX channels required by the fixtures. Note that if independent control of a fixture is required, it must have its own DMX channels. Fixtures that are required to behave identically can share the same DMX address and channels. To add more fixtures or groups of fixtures when the above limits are reached, add a DMX universe and/or split the daisy-chained link into branches.
Tips for reliable data transmission
Use shielded twisted-pair cable designed for RS-485 devices: standard microphone cable cannot transmit control data reliably over long runs. 24 AWG cable is suitable for runs up to 300 meters (1000 ft.). Heavier gauge cable and/or an amplifier is recommended for longer runs. The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+). Pins 4 and 5 in the 5-pin XLR connectors are not used in the fixture but are available for possible additional data signals as required by the DMX512-A standard. Standard pin-out is pin 4 = data 2 cold (-) and pin 5 = data 2 hot (+).
To split the link into branches, use an opto-isolated splitter such as the Martin™ DMX 5.3 Splitter. Terminate the link by installing a termination plug in the output socket of the last fixture. The termination plug, which is a male XLR plug with a 120-Ohm, 0.25-Watt resistor soldered between pins 2 and 3, “soaks up” the control signal so it does not reflect and cause interference. If a splitter is used, terminate each branch of the link.
Connecting the data link
To connect the fixture to data:
1. Connect the DMX data output from the controller to the closest fixture’s
male XLR DMX input connector.
2. Connect the first fixture’s DMX output to the DMX input of the next fixture
and continue connecting fixtures output to input. Terminate the last fixture on the link with a DMX termination plug.
Page 16
16 RUSH™ MH 6 Wash CT User Manual
Fixture setup
This section explains the fixture characteristics that can be set that determine how it can be controlled and will behave. These settings are made using the menus available from the control panel and are retained even when the fixture is powered off.
Only the most commonly used menu options for fixture setup are described in this section. A complete map of the control menu structure and brief explanations of their purposes can be found on page 25.
Using the control menus
To access the control menus, press the MENU button. Navigate the menu structure using the ENTER, DOWN and UP buttons. To select a menu option or to confirm a selection, press the ENTER button. To return to a higher level in the menu structure without making a change, press the MENU button.
To exit the control menus completely, press and hold the MENU button.
DMX addressing
The DMX address, also known as the start channel, is the first channel used to receive instructions from a DMX controller. The fixture is controlled using twelve (12) DMX channels. Each DMX controlled fixture must have a DMX address set. For example, if a fixture has a DMX address of 13, then it uses channels 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23 and 24. The following fixture in the DMX chain could then be set to a DMX address of 25.
For independent control, each fixture must be assigned its own control channels. Two fixtures of the same type may share the same address if identical behavior is desired. Address sharing can be useful for diagnostic purposes and symmetric control, particularly when combined with the inverse pan and tilt options.
To set the fixture’s DMX address:
1. In the control menu, select DMX ADDRESS and press ENTER to confirm. The present address will blink in the display.
2. Use the UP and DOWN buttons to select the address (1 to 501).
3. Press ENTER to confirm your selection.
Blackout or hold if DMX signal stops
To decide how the fixture behaves if the DMX signal is lost:
1. Select DMX STATE and press ENTER. The currently set mode will blink in the display.
Page 17
RUSH™ MH 6 Wash CT User Manual 17
2. Use the DOWN and UP buttons to select the behavior:
- Select BLACKOUT if you want the fixture to black out if the DMX signal is lost.
- Select HOLD if you want the fixture to continue showing the effect that it is displaying when the DMX signal is lost.
3. Press ENTER to save your selection.
Dimming curves
Four dimming modes are available: MODE 1 LINEAR: the increase in light intensity appears to be linear as
DMX value is increased.
MODE 2 SQUARE LAW: light intensity control is finer at low levels and
coarser at high levels.
MODE 3 INVERSE SQUARE LAW: light intensity control is coarser at low
levels and finer at high levels.
MODE 4 S-CURVE: light intensity control is finer at low levels and high
levels and coarser at medium levels.
To set the fixture’s dimmer curve:
1. Select DIMMER CURVE and press ENTER to confirm. The mode that is currently active will blink in the display.
2. Use the DOWN and UP buttons to select MODE1, MODE2, MODE3 or MODE4.
3. Press ENTER to save your selection.
Dimmer speed
There are two dimmer speed options:
SNAP is the default setting. It sets the dimmer to exactly follow changes in dimming level sent from the controller. This gives the fastest dimmer response.
FADE adds a two-second (approx.) smooth fade to changes in dimming level sent from the controller. This gives the smoothest dimmer fading.
Page 18
18 RUSH™ MH 6 Wash CT User Manual
To set the dimmer speed:
1. Select DIMMER SPEED and press ENTER to confirm.
2. Use the DOWN and UP buttons to select SNAP or FADE. Press ENTER to confirm.
Pan/tilt inversion
The PAN INVERSE and TILT INVERSE menus can be used to reverse the direction of pan and tilt. These settings are useful for symmetrical effects with multiple fixtures, or when coordinating the movement of fixtures that are floor mounted and rigged upside down.
To adjust the pan or tilt inversion settings:
1. Select PAN INVERSE or TILT INVERSE and press ENTER.
2. Use the DOWN and UP buttons to select YES to reverse direction or NO for normal control. Press ENTER to save your selection.
Backlight
To turn the control panel display backlight on or off:
1. Select BACK LIGHT and press ENTER to confirm. The present mode will blink in the display.
2. Use the DOWN and UP buttons to select ON or OFF.
3. Press ENTER to save your selection.
Temperature
To check the onboard temperature of the fixture:
1. Select TEMP and press ENTER. The display will show the temperature of the unit.
2. Press MENU to exit.
Fixture time
To display the fixture’s operating hours counter:
1. Select FIXTURE TIME and press ENTER. The display will show the number of hours the fixture has been in operation since manufacture.
2. Press MENU to exit.
Auto test
To perform a complete test of all fixture functions, select AUTO TEST and press ENTER. Press MENU to exit the test.
Page 19
RUSH™ MH 6 Wash CT User Manual 19
Manual test
Fixture functions can be controlled manually to test them or set up a static scene. To operate the fixture effects manually:
1. Select MANUAL TEST and press ENTER.
2. Select PAN, TILT, WARM, COLD, ZOOM, DIMMER or STROBE and press ENTER.
3. Use the DOWN and UP buttons to set the value (0-255).
4. Press MENU to exit.
Reset
The fixture resets each time you power it on, but you can also reset the fixture manually from the control panel and by DMX. To carry out a manual reset, scroll to RESET and press ENTER.
Home position (offsets) adjustment
If the fixture head or zoom angle do not return to their home positions, even after a reset, you can adjust their home positions by defining offsets.
To make the adjustment from the control menu:
1. In the menu structure, press and hold ENTER for at least 3 seconds to enter Offset mode.
2. Use the DOWN and UP buttons up to choose PAN OFFSET, TILT OFFSET, or ZOOM OFFSET. Press ENTER and the display will blink.
3. Use the DOWN and UP buttons to adjust the effect’s home position.
4. Press ENTER to save your selection.
To make adjustments via DMX:
1. Select the fixture on the controller.
2. For each effect that requires calibration, enable calibration (DMX value 55-
59) on the fixture’s DMX channel 12, Fixture Control Settings.
3. Adjust zoom position on channel 7, pan position on channel 8, or tilt position on channel 10.
4. Store the effect’s calibration value on DMX channel 12. Store zoom calibration with DMX value 230-234, pan calibration with DMX value 235­249, or tilt calibration with DMX value 240-244.
5. Repeat steps 2 – 4 as necessary.
6. When finished calibrating effects, set channel 12 to “No function” to resume normal DMX control.
Page 20
20 RUSH™ MH 6 Wash CT User Manual
Effects
See ‘DMX protocol’ on page 23 for a full list of the DMX channels and values required to control the different effects.
Pan and tilt
The fixture’s head can be panned through 540° and tilted through 220° with fine, 16-bit control. Using the control menus it is possible to invert pan or tilt movement and enable or disable blackout during movement of the fixture head.
Strobe effects
The strobe effects provide instant open and blackout, variable speed regular and random strobe.
Electronic dimming
Overall intensity can be adjusted 0-100% using 16-bit electronic dimming. Four different dimming curves are available (see ‘Dimming curves’ on page
17).
Color temperature
DMX channels 4 and 5 provide full range warm-white/cold-white color mixing from 2700 K to 7800 K.
The RUSH™ MH 6 Wash CT also provides premixed white tones in approximately 100 K steps on channel 6.
Note that premixed white tones (on channel 6) override warm-white/cold-white mixing (on channels 4 and 5). To control color temperature with channels 4 and 5, disable the premixed white tones by setting channel 6 to a DMX value from 0 to 26.
Zoom
The beam can be zoomed from a wide angle of 60° to a narrow angle of 10°.
Page 21
RUSH™ MH 6 Wash CT User Manual 21
Maintenance
Warning! Read ‘Safety information’ on page 4 before servicing the fixture.
Refer any service operation not described in this user manual to a qualified service technician.
Disconnect the fixture from mains power before cleaning or servicing.
Service fixtures in an area where there is no risk of injury from failing parts, tools or other materials.
The user may carry out the service operations described in this manual. All other service operations must be carried out by an authorized Martin™ service technician. Do not try to repair the fixture yourself, as you may create a safety risk or cause damage that is not covered by the product warranty.
Installation, on-site service and maintenance can be provided worldwide by the Martin Professional Global Service organization and its approved agents, giving owners access to Martin’s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product’s lifetime. Please contact Martin™ for details.
Cleaning
Excessive dust, smoke fluid, and particle buildup degrades performance, causes overheating and will damage the fixture. Damage caused by inadequate cleaning or maintenance is not covered by the product warranty.
The cleaning of external optical lenses must be carried out periodically to optimize light output. Cleaning schedules for lighting fixtures vary greatly depending on the operating environment. It is therefore impossible to specify precise cleaning intervals for the fixture. Environmental factors that may result in a need for frequent cleaning include:
Use of smoke or fog machines.
High airflow rates (near air conditioning vents, for example).
Presence of cigarette smoke.
Airborne dust (from stage effects, building structures and fittings or the
natural environment at outdoor events, for example).
If one or more of these factors is present, inspect fixtures within their first 100 hours of operation to see whether cleaning is necessary. Check again at frequent intervals. This procedure will allow you to assess cleaning requirements in your particular situation. If in doubt, consult your Martin dealer about a suitable maintenance schedule.
Page 22
22 RUSH™ MH 6 Wash CT User Manual
Use gentle pressure only when cleaning, and work in a clean, well-lit area. Do not use any product that contains solvents or abrasives, as these can cause surface damage.
To clean the fixture:
1. Disconnect the fixture from power and allow it to cool for at least 10 minutes.
2. Vacuum or gently blow away dust and loose particles from the outside of the fixture and the air vents at the back and sides of the head and in the base with low-pressure compressed air.
3. Clean surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water.
4. Check that the fixture is dry before reapplying power.
Replacing the primary fuse
If the fixture is completely dead, the fixture’s primary fuse F1 may have blown and it may be necessary to install a new fuse. This fuse is located in a fuseholder next to the MAINS IN and OUT sockets on the connections panel. See ‘Fixture overview’ on page 14.
If you need to replace a fuse:
1. Disconnect the fixture from power and allow it to cool for at least 10 minutes.
2. Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and specified rating only.
3. Reinstall the fuseholder cap before reapplying power.
Service and repairs
There are no user serviceable parts inside the fixture. Do not open the housing.
Never try to repair the fixture by yourself as this may result in damage or malfunction and it may potentially void your product warranty. The equipment must only be serviced or repaired by an authorized Martin service technician.
Page 23
RUSH™ MH 6 Wash CT User Manual 23
DMX protocol
DMX Value Function
Fade
type
Default
1
Strobe and Pulse effects
Snap 12
0–7 Off
8–15 Open
16–131 Strobe, slow to fast 132–139 Open 140–181 Pulse, fast close & slow open 182–189 Open 190–231 Pulse, fast open & slow close 232–239 Open 240–247 Strobe random 248–255 Open
2 0–255 Dimming Coarse 0 100% Fade 0 3 0–255
Dimming Fine
Fade 0 4 0–255 Warm White 0 → 100% Fade 0 5 0–255 Cold White 0 → 100% Fade 0
6
Color Temperature Presets
Fade 60
0-26 Presets disabled
27-72
Preset tones, 2700 7800 K in ~100 K steps (overrides channels 4 & 5)
73-255 7800 K 7 0–255 Zoom wide narrow Fade 128 8 0–255 Pan 540° Fade 128 9 0–255 Pan (fine control) Fade 128
10 0–255 Tilt 220° Fade 128 11 0–255 Tilt (fine control) Fade 128
Page 24
24 RUSH™ MH 6 Wash CT User Manual
12
Fixture Control Settings
Snap 0
0–9 No function (disables calibration) 10–14 Reset fixture 15–54 No function 55–59 Enable calibration 60–74 No function 75–79 Pan & Tilt Speed = Normal 80–89 Pan & Tilt Speed = Fast (default) 90–94 Pan & Tilt Speed = Slow
95–144 No function 145–149 Pan/tilt blackout = ON 150–154 Pan/tilt blackout = OFF 155–159 Illuminate display 160–164 Display illumination off 165–229 No function 230–234 Store zoom calibration 235–239 Store pan calibration 240–244 Store tilt calibration 245–249 Reset all calibrations to factory default 250–255 No function
Page 25
RUSH™ MH 6 Wash CT User Manual 25
Control menus
To access the control menus, press the MENU button. Use the UP and DOWN buttons to navigate the menus. Select a menu option with the ENTER button. For more information, see ‘Using the control menus’ on page 16.
Default fixture settings are shown in bold.
Menu Sub-menu Explanation
DMX Address 001–512 Fixture DMX address setting
Dimmer Curve
Mode 1
Optically linear Mode 2 Square law Mode 3 Inverse square law Mode 4 S-curve
Pan Inverse
Yes Invert pan control
No
Normal pan control
Tilt Inverse
Yes Invert tilt control
No
Normal tilt control
Back light
On Control panel display backlight on
Off
Display backlight off
Dimmer Speed
Fade Optimize dimmer for smoothness
Snap
Optimize dimmer for speed
DMX State
Blackout
If no DMX signal, fixture blacks out
Hold
If no DMX signal, fixture remains in the
state it was last in when receiving DMX
Manual Test
Pan (0…255)
Set parameter level
Tilt (0…255) Warm (0…255) Cold (0…255) Zoom (0…255) Dimmer (0…255) Strobe (0…255)
Auto test Automatic test of all functions Temp. Temperature of onboard sensor Fixture Time Fixture operating hours counter Firmware
Version
Currently installed firmware version
PRO Defaults
No
Keep user settings Yes Restore factory default settings
Reset Reset fixture
Page 26
26 RUSH™ MH 6 Wash CT User Manual
To access the Offset menu, press MENU to enter the menu structure and then press and hold ENTER for three seconds.
Menu Sub-menu Explanation
Offset
Pan offset (-127...127) Adjust home pan position Tilt offset (-127...127) Adjust home tilt position Zoom offset (0…255) Adjust home zoom position
Page 27
RUSH™ MH 6 Wash CT User Manual 27
Troubleshooting
This section describes a few common problems that may occur during operation and provides some suggestions for easy troubleshooting:
Symptom Potential Causes Remedies
No light from fixture, or fans not working.
Power supply issue such as blown fuse, faulty connector or damaged cable.
Ensure that the mains supply is connected and supplying power to the fixture.
Check all power connections and cables.
Check and if necessary replace the fixture fuse.
One of the control channels is unresponsive or only responds intermittently.
DMX setup or DMX link fault.
Damaged step motor or cable connection between head and body.
See next section.
Contact your Martin authorized distributor or service center for assistance.
Fixture does not respond to DMX control.
Fault in the DMX network due to connector or cable damage, incorrect DMX addressing, or potential interference from proximity to a high voltage installation.
Ensure that fixture’s DMX address matches address set on DMX control device.
Check that fixture DMX LED is on, and if not, check all DMX cables and connections.
Ensure that DMX link is terminated.
Check that all components on DMX link use standard DMX polarity.
Attempt to control the fixture with another DMX control device.
Move or shield link if it is close to an unshielded high-voltage installation.
Page 28
28 RUSH™ MH 6 Wash CT User Manual
Specifications
Physical
Dimensions( LxWxH) ..................... 290 x 189 x 360 mm (11.4 x 7.4 x 14.2 in.)
Weight .................................................................................... 7.1 kg (15.7 lbs.)
Dynamic Effects
Color temperature .................................................................. 2700 K - 7800 K
Color temperature presets ........................... 2700 K to 7800 K in ~100 K steps
Electronic dimming ....................... 16-bit, 0-100%, four dimming curve options
Strobe and pulse effects ................ Variable speed and action, random strobe
Electronic 'shutter' effect ......................................... Instant open and blackout
Zoom .................................................................................. Motorized, 10 - 60°
Pan ..................................................................................... 540°, 16-bit control
Tilt ....................................................................................... 220°, 16-bit control
Optics
Light source ............................................................... 12 x 10 W CWUW LEDs
Minimum LED lifetime ..................... 50 000 hours (to >70% luminous output)*
One-tenth peak beam angle ............................................................... 10° - 60°
*Figure obtained under manufacturer´s test conditions
Control and Programming
Control system .......................................................................................... DMX
DMX channels ............................................................................................... 12
16-bit fine control ............................................................. Dimming, pan and tilt
DMX address setting ....................................... Control panel with LCD display
DMX compliance ............................................................ USITT DMX512/1990
Construction
Housing ......................................... High-impact flame-retardant thermoplastic
Color ......................................................................................................... Black
Ingress protection rating ........................................................................... IP 20
Page 29
RUSH™ MH 6 Wash CT User Manual 29
Installation
Mounting points ............................. One quarterturn bracket for rigging clamp
Location .................. Indoor use only, must be fastened to surface or structure
Orientation ...................................................................................................Any
Minimum distance to illuminated surfaces ................................ 200 mm (8 in.)
Minimum distance to combustible materials ............................. 100 mm (4 in.)
Minimum clearance around fans and vents .............................. 100 mm (4 in.)
Connections
AC power input .................................................................... Neutrik PowerCon
AC power throughput .......................................................... Neutrik PowerCon
DMX data in/out ........................................................ 3-pin & 5-pin locking XLR
Electrical
AC power ............................................................ 100-240 V nominal, 50/60 Hz
Power supply unit ................................... Auto-ranging electronic switch mode
Fuse .................................................................................................... T 3.15 A
Recommended Miniature Circuit Breaker* ............................................ Type D
*Per IEC 60898/UL489/CSA C22.2 No. 5
Typical power and current
120 V, 60 Hz .................................................................. 1.3 A, 150 W, PF 0.99
230 V, 50 Hz .................................................................. 0.7 A, 150 W, PF 0.94
Typical half-cycle RMS inrush current at 240 VAC ................................ 11.3 A
Measurements made at nominal voltage with all LEDs at full intensity. Allow for a deviation of +/- 10%.
Thermal
Cooling ..................................... Forced air (temperature regulated, low noise)
Maximum ambient temperature (T
a
max.) ................................. 40° C (104° F)
Minimum ambient temperature (T
a
min) ......................................... 0° C (32° F)
Approvals
EU safety ...................... EN 60598-2-17 (EN605989-1), EN 62471, EN 62493
EU EMC ........................... EN 55015, EN 55032, EN 55103-2, EN 61000-3-2,
EN 61000-3-3, EN 61547
US safety ............................................................................. UL 1573, UL 8750
US EMC ........................................................................... CFR Title 47 Part 15
Canadian safety ................................................................ CSA C22.2 No. 166
Australia/NZ ..................................................... C-Tick N4241 / RCM (pending)
Page 30
30 RUSH™ MH 6 Wash CT User Manual
Included Items
Power input cable, 6 A, 18 AWG, UL, 0.75 mm
2
, H05VV-F, 1.5 m (4.9 ft.),
without mains plug, for connecting one fixture only to power Omega bracket for rigging clamp attachment
Accessories
Cables, 16 A, for connecting fixtures to power in chains
Power input cable, 14 AWG, UL, SJT, 1.5 mm
2
, H05VV-F,
with PowerCon input connector, 3 m (9.8 ft.) .......................... P/N 11541508
Power relay cable, 14 AWG, UL, SJT, 1.5 mm
2
, H05VV-F,
with PowerCon connectors, 1.4 m (4.6 ft.) .............................. P/N 11541509
Power relay cable, 14 AWG, UL, SJT, 1.5 mm
2
, H05VV-F,
with PowerCon connectors, 2.25 m (7.4 ft.) ............................ P/N 11541510
Power relay cable, 14 AWG, UL, SJT, 1.5 mm
2
, H05VV-F,
with PowerCon connectors, 3.25 m (10.7 ft.) .......................... P/N 11541511
Power connectors
Neutrik PowerCon NAC3FCA
power input connector, cable mount, blue .............................. P/N 05342804
Neutrik PowerCon NAC3FCB
power output connector, cable mount, light grey .................... P/N 05342805
DMX link
DMX termination plug, 3-pin male XLR ..................................... P/N 91613017
Installation hardware
Half-coupler clamp .................................................................... P/N 91602005
G-clamp ..................................................................................... P/N 91602003
Quick-trigger clamp ................................................................... P/N 91602007
Safety cable, safe working load 50 kg ....................................... P/N 91604003
Related Items
RUSH™ Software Uploader 1 ................................................... P/N 91611399
Ordering Information
RUSH™ MH 6 Wash CT in cardboard box ............................... P/N 90280090
Specifications subject to change without notice. For latest product specifications, see www.martin.com
Page 31
Disposing of this product
Martin™ products are supplied in compliance with Directive 2012/19/EC of the European Parliament and of the Council of the European Union on WEEE (Waste Electrical and Electronic Equipment), where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of Martin products
Photobiological Safety Warning
The label shown below is displayed on this product. If it becomes difficult or impossible to read, it must be replaced using the illustration below to reproduce a new label sized 45 x 18 mm, in black on a yellow background.
RISK GROUP 2
CAUTION. Possibly hazardous optical
radiation emitted from this product.
Do not stare at operating lamp. May be harmful to the eyes.
Page 32
Loading...