Martin Roboscan Pro 1220 Operator's Manual

© 1995-1996 Martin Professional A/S
Roboscan Pro 1220
operator’s manual
Part# 510061
© 1995-1996 Martin Professional A/S, Denmark.
All ri
hts reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writin
g
from Martin Professional A/S,
Denmark.
Printed in Denmark.
Revision #961029-PS. P/N 510061.
Roboscan Pro 1220 - operator’s ma nual 3
© 1995-1996 Martin Professional A/S
section 1
INTRODUCTION
The Roboscan Pro 1220 features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
section 2
INSTALLING THE PRO 1220
Installing the Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Fitting the Mains Plug. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Checking the Voltage and Frequency Setting . . . . . . . . . . . . . . . . . . . . . . . . 10
Fitting the Mounting Bracket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Removing the Transport Fixture from the Pan/tilt Assembly . . . . . . . . . . . . . 11
section 3
OPERATING VIA A LIGHTING CONTROLLER
Connecting the Data Link. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Addressing the Pro 1220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Controlling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
section 4
REMOTELY CONTROLLABLE FUNCTIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
section 5
THE PRO 1220 CONTROL MODULE
dAdr - DMX 512 Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Adr - Martin Link Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
PSEt - Protocol Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
SPEC - Special Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Po H - Total Power-On Time (Fixture) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
LA H - Total Lamp-On Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
r Po - Resetable Power-On Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
r LA - Resetable Lamp-On Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Error and Information Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4 Roboscan Pro 1220 - operator’s manual
section 6
HARDWARE SETTINGS AND ADJUSTMENTS
Removing and Replacing Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Voltage and Frequency Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Lamp Replacement and Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Adjusting the Pan/Tilt Stops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Adjusting the Pan/Tilt Dampers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Regenerating Malfunctioning Lamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
section 7
MAINTENANCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
appendix a
DMX PROTOCOL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
appendix b
SPECIAL SEQUENCES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
appendix c
TECHNICAL SPECIFICATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Roboscan Pro 1220 - operator’s ma nual 5
© 1995-1996 Martin Professional A/S
section 1
INTRODUCTION
Congratulations on your choice of the
Roboscan Pro 1220
, designed and manufactured by Martin Professional. The Roboscan Pro 1220 is a high performance, intelligent lighting projector meeting the demands of tomorrow's light ing designers. The rugged co nstruction combined with the us e of high quality components ensures that your Roboscan Pro 1220 will perform reliably for many years to come.
The Roboscan Pro 1220 features
LIGHT SOURCE
1200 Watt HMI or MSR lamp de pending on model.
Remote ON / OF F vi a co ntr olle r.
MOVEMENT
Smooth and accurate movement at all speeds.
176 degree pan in 0.028 degree steps (6,240 p ositions).
85 degree tilt in 0.056 degree steps (1,504 positions).
8 and 16-bit tracking available via D MX 512.
Straight diagonal movements via vector protocol.
COLOR WHEELS
Two separate and overlapping color wheels each with 9 dichroic co lors plus white (only one wheel on Pro 1220 XR).
Dual-direction, continuous rotation on both whe els.
Micro-stepping resolution (12,800 steps/360°).
Color mixing/splitting.
Hot and cold Color Temperature Correction (CT C) on second color whee l (Pro 1220 CMYR and RPR only).
CMY - INFINITE COLOR MIXING SYSTEM (PRO 1220 CMYR)
Infinite color selection via CMY color mixing system.
Instant color change or smoo th colo r fades.
GOBO WHEELS
4 rotating and indexable gobos, plus open.
9 fixed gobos plus open, with smooth gobo scrolling.
Micro-stepping resolution (12,800 steps/360°).
6 Roboscan Pro 1220 - operator’s manual
Fixed and rotating gobos can be c ombined.
DIMMER / SHUTTER
High-speed shutter (2 to 16 Hz) for instant black-out and fast strobe.
0 to 100% smooth dimming with micro-stepping resolution.
FOCUS
Motorized focus with precision coated optics.
IRIS
Motorized iris for different beam diameters.
EFFECT WHEEL (PRO 1220 CMYR / XR)
3 and 5 facet prism for multiplying images.
Frost filter for soft-e dged imag es.
Hot Color Temperature Correction (Pro 1220 XR only).
ROTATING PRISMS (PRO 1220 RPR)
3 rotating and indexable prisms, plus o ne fre e position for a n optional rotating prism.
MECHANICAL CONSTRUCTION
Modular design for ease of servic ing and flexibility.
Cover with snap-lock and safety wire provides instant a ccess to serviceable parts.
Adjustable mounting bracket.
Four carrying handles.
The modular design enables future up grades.
CONTROL, SETTING AND MONITORING
Can be controlled by D MX 512 o r Martin RS-48 5.
Simple digital addressing via control module with 4-digit display.
Simple setting for pan/tilt invert and swap.
Digital read-out of lamp and fixture usage.
COOLING AND SECURITY.
Efficient fan cooling.
Fan speed can be reduced via controller when silent perfor mance is required.
Overheating protection.
Access, safety cut-off.
Power Factor Correction for low curren t consumption.
Roboscan Pro 1220 - operator’s ma nual 7
© 1995-1996 Martin Professional A/S
About this Manual
This user's manual covers Pro 1220 CMYR / XR fixtures fitted with the following software:
Device Version(s) Part#
Pro 1220
CMYR
CPU A Section 2.0 219806 CPU B Section 2.0 219806 CPU Control Module 3.3 , 3.4 219810 EPROM A Section 2.6 , 2.7 , 2.8 219025 EPROM B Section 2.6 , 2.7 219026
Pro 1220
XR
CPU A Section 2.0 219806 CPU Control Module 3.3 , 3.4 219812 EPROM A Section 1.4 , 1.5 , 1.6 219030
Pro 1220
RPR
CPU A Section 2.0 219806 CPU B Section 2.0 219806 CPU Control Module 1.1 219814 EPROM A Section 1.0 219027 EPROM B Section 1.1 219028
8 Roboscan Pro 1220 - operator’s manu al
section 2
INSTALLING THE PRO 1220
The Roboscan Pro 1220 is delivered fully prepared from the factory so only a few basic procedures are necessary, and you will be ready to operate your new lighting equipment.
Your Roboscan Pro 1220 package comes complete with the following items:
Roboscan Pro 1220 CMYR / Pro 1220 XR / Pro 1 220 RPR.
Mounting bracket including fittings.
5 metres XLR-XLR cabl e for con trol.
User's manual.
15 metres power multi-cable (Pro 1220 Studio Version only).
WARNING!
Before attemptin g any of the fo llowin g you must en sure that the fi xture is dis-
connected from the mains supply.
Installing the Lamp
Pro 1220 HMI fixtures uses the double end ed HMI 12 00 lam p from Osr am and Pro 12 20 MSR fix­tures the single ended MSR 1200 from Philips. Please follow the procedure below in order to install the lamp in a safe and proper way.
HMI 1200 LAMP
1.
Place the Pro 1220 on a table so that the mirror is up.
2.
Locate the snap-lock on the fan-end of the fixture and press the small section on the left hand side of this lock, thus releasing the main cover. Now, slide the whole main-cover approxi­mately 3 cm towards the mirror and then remove it upwards, being careful not to damage the mirror while revealing the inside of the fixture.
3.
Locate the lamp module at the fan-end of the fixture and release the two finger screws which secure the module to the chassis.
4.
Pull the module straight out of the fixture being careful as you lift and then place it on a sur­face with the bright side of the reflector upwards.
5.
Hold the lamp with a clean cloth, avoiding touching the glass envelope with your fingers, and
Roboscan Pro 1220 - operator’s ma nual 9
© 1995-1996 Martin Professional A/S
carefully insert it into the lamp socket.
6. Again, without touching the glass envelope with your fingers, turn the lamp around its centre­axis until the small nipple on the bulb is straight up and thus facing the chassis plate when the lamp module is replaced in the fixture. Then tighten the finger nuts on the lamp, thus securing it to the holder.
7. Carefully clean the lamp using the cleaning cloth provided with the lamp.
8. Replace the lamp module and tighten the two finger screws.
9. Replace the main-cover by locating it back onto the fixture and then slide it towards the fan-
end of the fixture. It is necessary to replace the cover in this way as there are some securing points along the side of the case which have to slide into one another to secure the cover cor­rectly. When the cover is in place, simply press the large section of the lock until it clicks and latches into position.
MSR 1200 LAMP
1. Place the Pro 1220 on a table so that the mirror is up.
2. Locate the snap-lock on the fan-end of the fixture and press the small section on the left hand
side of this lock, thus releasing the main cover. Now, slide the whole main-cover approxi­mately 3 cm towards the mirror and then remove it upwards, being careful not to damage the mirror while revealing the inside of the fixture.
3. Locate the lamp holder assembly at the fan end of the fixture and turn the two finger screws a quarter turn counter clockwise, thus releasing the assembly from the reflector and lens-mod­ules.
4. Withdraw the lamp socket assembly.
5. Hold the lamp in a clean cloth or by the ceramic base, avoiding touching the glass envelope
with your fingers, and then press it firmly into the lamp socket.
6. Carefully clean the lamp using the cleaning cloth provided with the lamp.
7. Replace the lamp holder assembly and tighten the two finger screws.
8. Replace the main-cover by locating it back onto the fixture and then slide it towards the fan-
end of the fixture. It's necessary to replace the cover in this way as there are some securing points along the side of the case which have to slide into one another to secure the cover cor­rectly. When the cover is in place, simply press the large section of the lock until it clicks and latches into position.
NOTE:
The lamp position has already been adjusted at the factory, however, re-adjustment may be necessary to optimize the light output and the color uniformity from the CMY (Cyan, Magenta, Yellow) system in the Pro 1220 CMYR. Please refer to section 6 - 'HARDWARE SETTINGS AND ADJUSTMENTS'.
10 Roboscan Pro 1220 - operator’s manual
Fitting the Mains Plug
The Roboscan Pro 1220 is delivered from the factory without a plug on the mains cable. You will have to fit a suitable plug (one that fits your local mains outlet) before you can connect the fixture to the mains. The double insulated mains cable contains three wires.
1.
Connect the BROWN wire to the LIVE pin.
2.
Connect the BLUE wire to the NEUTRAL pin.
3.
Connect the YELLOW/GREEN wire to the EARTH pin.
NOTE: If you have purchased a Pro 1220 Studio Version (Pro 1220 CMYRST / Pro 1220 XRST) you will find the mains cable attached to the remote ballast box. Use the supplied power multi-cable to connect the ballast box to the Pro 1220 fixture.
Checking the Voltage and Frequency Setting
It is vital that the voltage and frequen cy sett i ng on your P ro 122 0 mat ches your local power s upp ly . If this is not the case, you will have to rewire the fixture as desc ribed in th e se ction call ed 'HA RD­WARE SETTINGS AND ADJUSTMENT'. To check whether the factory setting is correct or not, please do as follows:
1.
Locate on the front of the fixture the serial number label onto which the factory setting for volt­age and frequency is printed.
2.
Now, check the factory setting against your local mains voltage, using the following table.
3.
Then, check the factory setting against you local mains frequency. If you have a Pro 1220 Stu­dio Version you will find the frequency setting on the serial number label located on the remote ballast box.
Correct Voltage Setting Local Mains Voltage
Correct Voltage Setting Local Mains Voltage
100 V 95 - 110 V 210 V 200 - 220 V 120 V 110 - 130 V 230 V 220 - 240 V
250 V 240 - 260 V
Roboscan Pro 1220 - operator’s ma nual 11
© 1995-1996 Martin Professional A/S
Fitting the Mounting Bracket
The mounting bracket is already fitted onto the Pro 1220, however, you will have to secure it before rigging the fixture.
1.
Locate the four studs that come out through the bracket on the sides of the Pro 1220.
2.
Secure the bracket by first fitting the four metal washers and then the four lever handles that came with the Pro 1220.
Removing the Transport Fixture from the Pan/tilt Assembly
In order to protect the mirror and stepper motors from becoming damaged during shipment they have been secured by two black plastic straps.
1.
First, carefully remove the surface protection foil and warning notice from the mirror.
2.
Then, remove the black plastic straps.
12 Roboscan Pro 1220 - operator’s manual
section 3
OPERATING VIA A LIGHTING CONTROLLER
All effects in the Roboscan Pro 1220 are fully DMX 512 and Martin RS-485 implemented, i.e you can use any DMX board or the Martin 3032 controller to operate it. All control data are transm itted from the controller’s output, via XLR data link cables, to the data inpu t on the Roboscan Pro 1220 (that is the 3 pin XLR male on the front). The data output (3 p in XLR female) on the Roboscan Pro 1220 allows the serial data link to be continued to further fi xtures, and this way up to 16 Robos cans Pro 1220s can be connected on the same data link.
Connecting the Data Link
You should follow this instruction carefully in order to ma ke a proper serial data link:
1.
Connect the data output on your lighting controller to the data input on the Roboscan Pro
1220. If you are using a Martin lighting controller then use the XLR-XLR / DSUB-XLR cable supplied with the controller. Otherwise, use a cable that fits your DMX lighting controller and the Roboscan Pro 1220. This would normally be a cable that adapts from 5 pin XLR to 3 pin XLR and reverses the (+) and (-) signal wires. The following figure shows the proper connec­tions in such a cable (P/N 309162). Please note that the (+) and (-) signal wires swap from the DMX output to the input on the Roboscan Pro 1220.
2.
If you are using one Roboscan Pro 1220 only, then insert a XLR terminating plug into the unused data output socket on the Pro 1220. If a Martin lighting controller is being used then insert the termination plug that came with the controller (120 Ohm XLR-male). Otherwise, use a termination plug as specified by the DMX controller's manual.
3.
If you are using more than one lighting fixture with the controller then connect the data output on each fixture to the data input on the following fixture using XLR-XLR cables. The order, in which you connect the fixtures, is not important and has no influence on the channels as far as the controller is concerned - use an order which gives the easiest and shortest cable routing. To ensure proper transmission on the data link it is
very important
to insert the XLR terminat-
ing plug in the last fixture in the link.
NOTE: It is possible to insert other DMX fix tures in the link with 5 pin XLR in and out. In that case you will need a cable that adapts from the 3 pin female output on the Martin fixture to the 5 pin input on the following DMX fixture. The cable should reverse the (+) and (-) signal wires This cable is shown in number two of the following figures (P/N 309163).