Martin MAC 2000 Profile II User Manual

MAC 2000 Profile II
user manual
743
613
488
171
408
10° 28°
133½°133½°
271
759
270°270°
490
530
545
min c/c
© 2000-2005 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any
means, without permission in writing from Martin Professional A/S, Denmark. Printed in Denmark.
P/N 35000090 Rev. M
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
TRANSPORTATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Included items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Transport locks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cardboard box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Single flight case. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Double flight case. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
LAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Lamp replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
AC POWER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Power supply adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Power connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Reduced power function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Connecting fixtures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
RIGGING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Clamping the fixture to a truss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CONTROL PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DMX address and protocol setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Tailoring performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Readouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Service messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Service utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
OPTICAL CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Gobos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Rotating gobo wheels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Color/gobo wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Effect wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
EFFECTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Dimming and strobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Color mixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Color temperature correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Random color mixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Fixed colors and gobos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Gobos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Effect wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Iris. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Focus and zoom. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Pan and tilt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Speed control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
ROUTINE MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Software installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DMX PROTOCOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
CONTROL MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
ADJUSTMENT SUBMENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
DISPLAY MESSAGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
CIRCUIT BOARD CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
SPECIFICATIONS
MAC 2000 PROFILE II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
4 MAC 2000 Profile II
I
NTRODUCTION
Thank you for selecting the MAC 2000 Profile II. This extraordinary 1200 watt luminaire from Martin Professional provides CMY color mixing, continuous 0 - 178 mireds color correction, a color/gobo wheel with 4 dichroic color filters and 3 fixed glass gobos, 10 indexed-rotation gobos on 2 wheels, a 2-position rotating-effect wheel with 3-facet prism, beam shaper, and variable frost; combined full-range dimmer and shutter, iris, zoom, focus, 540° of pan, and 267° of tilt. It is available with a magnetic or electronic ballast.
For the latest firmware updates, documentation, and other information about this and all Martin Professional products, please visit the Martin web site at http://www.martin.dk.
Safety information
Warning! This product is for professional use only. It is not for household use.
This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radiation, lamp explosion, and falls. Read this manual before powering or installing the fixture, follow the safety precautions listed below and observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the fixture safely, please contact your Martin dealer or call the Martin 24-hour service hot line at +45 70 200 201.
Protecting against electric shock
• Disconnect the fixture from AC power before removing or installing the lamp, fuses, or any part, and when not in use.
• Always ground (earth) the fixture electrically.
• Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protection.
• Do not expose the fixture to rain or moisture.
• Refer any service operation not described in this manual to a qualified technician.
Protecting against UV radiation and lamp explosion
• Never operate the fixture with missing or damaged lenses and/or cover s.
• When replacing the lamp, allow the fixture to cool for at least 15 minutes before opening the fixture or removing the lamp. Protect your hands and eyes with gloves and safety glasses.
• Do not stare directly into the light. Never look at an exposed lamp while it is lit.
• Replace the lamp if it becomes defective or worn out, or before usage exceeds the maximum service life.
Protecting against burns and fire
• Never attempt to bypass the thermostatic switch or fuses. Always replace defective fuses with ones of the specified type and rating.
• Keep all combustible materials (for example f abr ic, wood, paper) at least 1 meter (39 inches) away from the fixture. Keep flammable materials well away from the fixture.
• Do not illuminate surfaces within 3 meter (10 inches) of the fixture.
• Provide a minimum clearance of 0.1 meters (4 inches) around fans and air vents.
• Never place filters or other materials over the lens.
• The exterior of the fixture can get very hot. Allow the fixture to cool for at least 5 minutes before handling.
• Do not modify the fixture or install other than genuine Martin parts.
• Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
Protecting against injury due to falls
• Do not lift or carry the fixture alone.
• When suspending the fixture, verify that the structure can hold at least 10 times the weight of all installed de vic es.
• Verify that all external covers and rigging hardware are securely fastened and use an approved means of secondary attachment such as a safety cable.
• Block access below the work area whenever installing or removing the fixture.
Transportation 5
T
RANSPORTATION
Important! Release the transport locks before operating the fixture.
Included items
The MAC 2000 Profile II is shipped in a cardboard box or in a 1 or 2 unit flight case that contains the following items.
• User manual
• 2 clamp attachment brackets
• 2 x 20 A main fuses (for use with 100-130 V local power supply)
• 2 x 15 A main fuses (for use with 200-250 V local power supply)
• XLR cable
Transport locks
The head and yoke may be locked for transportation and service. The locks are shown in Figure 1. The fixture must be unlocked before operation.
Cardboard box
Instructions for removing models that have been shipped in a cardboard box are printed on the outside of the box. The cardboard box is not designed for repeated use and for transportation of the fixture we strongly recommend the use of one of our flight cases.
Single flight case
Unpacking the fixture
1 Remove the top of the flight case. 2 With one person on each sid e, lift the fi xture out of the bottom
of the flight case.
3 Release the pan and tilt locks before operating.
Packing the fixture
1 Disconnect the fixture from power and allow it to cool. 2 Lock the head and yoke in the position shown in Figure 2. 3 Place the fixture in the bottom of the flight case. Place the
top section over the fixture without forcing.
Figure 1: Pan and tilt locks
Figure 2: Single unit transport position
6 MAC 2000 Profile II
Double flight case
Unpacking
1 Open the flight case and pull the drawer all the way out. 2 Release the head (tilt) transport lock. 3 Install rigging hardware as described on page 12. 4 With one person on each side, lift the fixture out of the flight
case.
Packing
1 Disconnect the fixture from power and allow it to cool. 2 Turn the yoke parallel to the sides of the base with the tilt
lock closest to the back.
3 Pull the transpor t drawer all the way out. With one person
on each side, place the fixture on the drawer with the arrow pointing in.
4 Remove and stow rigging hardware. Coil and stow the
power cord in the door.
5 Tilt the hea d so that the lens points away from the door as
shown in Figure 3. Lock the head in the horizontal position. Do not lock the yoke.
6 Slide the drawer all the way in without forcing. Close the flight case.
Setup for flight case testing
The double flight case has two slide-out arms from which the fixture can hang for testing and setting. Though unnecessary, the pan and tilt reset can be cancelled by pressing [Menu] and [Enter] at the same time.
1 Open the flight ca se and pull the drawer all the way out. Release the transport locks. 2 Pull the test arms all out. Tilt the fixture up and over the slide arms so that the handle cross-braces that are
second from the back rest on the arms. The fixture should rest at an angle.
3 Push the transport drawer into the flight case.
Figure 3: Double unit transport position
FRONT
Lamp 7
L
AMP
The MAC 2000 Profile II is supplied with a Philips MSR 1200 SA/DE GOLD 1200 W discharge lamp installed. This source has a color temperature of 6000 K, a color rendering index greater than 85, and an average life of 750 hours.
The lamp is capable of hot restrike. This feature, howev er, is only supported by the MAC 2000 Profile II with electronic ballast.
The ends of the lamp are profiled with special keys, as shown in Figure 6, to ensure proper installation. Do not use lamps with keys in a non-keyed SFc 10-4 socket.
Warning! Install only an approved lamp (see Source on
page 38). Installing any other lamp may create a safety hazard or damage the fixture!
The lamp should be replaced when it has reached the limit of its 750 hour average life. To reduce the risk of explosion, never exceed 125% of the lamp’s average life, i.e. 940 hours. To read lamp hours from the control panel, please refer to Readouts on page 14.
For optimum performance, avoid turning off the lamp before it has warmed up fully.
Lamp replacement
Important! Do not touch the quartz bulb with bare fingers.
The lamp can be replaced with either a:
• Philips MSR 1200 SA/DE GOLD (Martin P/N 97010310), or an
• OSRAM HMI 1200 W/S (Martin P/N 97010304). Both lamps are available from your Martin dealer.
The clear quartz bulb must be clean and free of any oils from your fingers. Clean the lamp with an alcohol wipe and polish it with a dry cloth, particularly if you accidentally touch the bulb.
Replacing the lamp
1 Disconnect the fixture from power and allow it to cool. Lock
the head horizontally with the top up.
2 See Figure 4. Release the 4 quarter-turn fasteners marked
with arrows on the rear plate. Pull the lamp assembly straight back as far as it goes and let it rest in place.
3 See Figure 5. Pull the reten tion spring on the left-hand end
of the lamp socket up and then swing the end of the lamp out. Pull the other end out of the socket.
4 Inspect the socket for corrosion (see Replacing the lamp socket on page 8) and replace if necessary.
TOP
TOP
Figure 4: Lamp access
Figure 5: Lamp removal
8 MAC 2000 Profile II
5 See Figure 6. With th e nipple on the bulb facing the back,
insert the right end of the new lamp in the socket. Pull up on the left spring and snap the other end into place.
6 Lift the lamp assembly so that lamp is level with the center
of the reflector. Push the assembly straight in until it seats, making sure the lamp passes through the reflector opening. Lock the 4 quarter-turn fasteners.
7 When installing a new lamp, reset the lamp hour and lamp
strike counters as described on page 14.
Aligning the lamp
1 Switch on the MAC 2000 Profile II and allow it to reset.
Using either a controller or the control module, turn on the lamp and project an open white beam on a flat surface.
2 Center the hot spot vertically using the top Allen-head
adjustment screw in the center of the rear plate.
3 If there is significant hot sp ot, turn the bottom adjustment
screw counterclockwise until the light is evenly distributed. If the light is brighter around the edge than it is in the center, or if light output is low, turn the bottom adjustment screw clockwise until the light is bright and evenly distributed.
4 Repeat step 2.
Replacing the lamp socket
A corroded lamp socket can lead to a bad contact, causing damage to the lamp. Damage caused by lack of maintenance of the lamp socket is not covered under warranty.
Inspect the lamp socket each time the lamp is changed, and replace it if its gold coating has corroded (turned a deep black color). We recommend routine replacement of the socket after maximum 4000 hours of use (replace one socket for every five lamps).
Figure 6: Lamp insertion
Figure 7: Lamp adjustment
AC power 9
AC
POWER
WARNING! For protection from electric shock, the fixture must be grounded (earthed). The AC mains
supply shall be fitted with a fuse or circuit breaker and ground-fault protection.
Important! Verify the power supply settings before applying power.
The chapter describes:
• Installing fuses
• Power supply adjustments for the various MAC 2000 Profile II models
• Connection to a power supply (see page 10)
• The reduced power function (see page 10)
Fuses
The MAC 2000 Profile II comes with two:
• 20 AT (time delay) main fuses for use with AC supplies of 100 - 120 volts.
• 15 A main fuses for use with AC supplies of 200 - 250 volts. Install the appropriate fuses in the holders near the power switch.
Power supply adjustments
The MAC 2000 Profile II (identified as such by the label on the base of the product) comes with an electronic or magnetic ballast and an auto-sensing, auto-ranging switch-mode power supply. Manual adjustments are not necessary unless you have the magnetic ballast version.
Magnetic ballast configuration
In magnetic ballast models the ballast must be tapped correctly for the local AC voltage and frequency. The wrong setting can cause overheating, damage, and poor performance. The factory settings are printed on the serial number label.
C
HANGING THE MAGNETIC BALLAST SETTINGS
1 Disconnect th e fixture from AC power. Remove the rear
base cover as shown in Figure 8.
2 To e xpose the ballast connection block, remo v e the scre ws
from each end of the side plate and tilt it down (Figure 8).
3 Find the ballast setting in Table 1.
AC frequency AC voltage Setting
50 Hz
200 - 218 V 208 V / 50 Hz 219 - 238 V 230 V / 50 Hz 239 - 250 V 245 V / 50Hz
60 Hz
200 - 218 V 208 V / 60 Hz 219 - 241 V 230 V / 60 Hz
Table 1: Magnetic ballast settings
ballast
Figure 8: Power supply access
10 MAC 2000 Profile II
4 Move the brown wire on the ballast connection block to
the position shown Figure 9.
5 Close the base before applying power.
Note: Magnetic ballast models only run on power supplies over 200 volts and in this operating
range the 15 amp main fuses must be installed.
Power connection
Important! Connect the MAC 2000 Profile II directly to AC power. Do not connect it to a dimmer
system; doing so may damage the fixture.
You may need to install a cord cap that fits your supply on the power cable. A 3-prong grounding-type plug must be installed following the manufacturer’s instructions. The table shows some possible pin identification schemes; if the pins are not clearly identified, or if you have any doubts about proper installation, consult a qualified electrician.
To apply power, set the power switch on the base to the “I” position.
Reduced power function
The MAC 2000 Profile II has an automatic power reduction function, which reduces the consumption to 700W if the shutter/dimmer is closed for more than 10 seconds. This not only increases the lamp life, but also further decreases the overall noise emission of the fixture.
Wire Color Pin Symbol Screw (US)
brown live L yellow or brass blue neutral N silver yellow/green ground green
Table 2: Cord cap connections
Figure 9: Magnetic ballast connections
230V/60Hz
230 V / 60 Hz
230V/50Hz
230 V / 50 Hz
245V/50Hz
245 V / 50 Hz
208V/60Hz
208 V / 60 Hz
208V/50Hz
208 V / 50 Hz
Brown
Black
Data 11
D
ATA
Important! Never connect more than 1 data input and 1 data output.
The MAC 2000 Profile II has both 3-pin and 5-pin XLR sockets for DMX input and output. The pin-out on all sockets is pin 1 to shield, pin 2 to cold (-), and pin 3 to hot (+). There is no connection to pins 4 and 5.
The sockets are wired in parallel: both inputs connect to both outputs. For reliable data transmission and to avoid
damage to the fixture, however, use one input and one output!
Connecting fixtures
• Use shielded twisted-pa ir cable designed for RS-485 devices: standard microphone cable cannot transmit control data reliably over long runs. 24 AWG cable is suitable for runs up to 300 meters (1000 ft). Heavier gauge cable and/or an amplifier is recommended for longer runs.
• Never use both outputs to split the link. To split the serial link into branches use a splitter such as the Martin 4-Channel Opto-Isolated RS-485 Splitter/Amplifier.
• Do not overload the link. Up to 32 devices may be connected on a serial link.
• Terminate the link by installing a termination plug in the output socket of the last fixture. The termination plug, which is a male XLR plug with a 120 ohm, 0.25 watt resistor soldered between pins 2 and 3, “soaks up” the control signal so it does not reflect and cause interference. If a splitter is used, terminate each branch of the link.
• Martin fixtures introduced before 1997 have reversed polarity data sockets (pin 2 hot and pin 3 cold). The socket polarity is labelled. Use a phase-reversing cable between the MAC 2000 Profile II and any Martin
device with reversed polarity.
C
ONNECTING THE DATA LINK
1 Connect the DMX data input from the controller to the MAC 2000 Profile II’s 3-pin or 5-pin input (male)
socket.
2 Using the sockets that match your data cable, connect the output of the fixture closest to the controller to the
input of the next fixture.
3 Insert a male 120 XLR termination plug in the 3-pin or 5-pin output of the last fixture on the link.
12 MAC 2000 Profile II
R
IGGING
The MAC 2000 Profile II can be placed on stage or clamped to a truss in any orientation. The Fast-Lock system enables quick and easy fastening of the clamp brackets in 4 positions as shown Figure 10.
Warning! Always use 2 clamps to rig the fixture. Lock each clamp with both 1/4-turn fasteners. The
fasteners are locked only when turned fully clockwise. Attach an approved safety cable to the attachment hole in the base. Never use the carrying handles for secondary attachment.
Clamping the fixture to a truss
1 V erify that the rigging clamps (not included) are undamaged and can bear at least 10 times the weight of the
fixture. Verify that the structure can bear at least 10 times the weight of all installed fixtures, clamps, cables, auxiliary equipment, etc.
2 Bolt each clamp securely to a clamp bracket with an M12 bolt (grade 8.8 or better) and lock nut. 3 Align a clamp with 2 mounting points in the base. Insert the fasteners into the base and tur n both levers a
full 1/4-turn clockwise to lock. Install the second clamp.
4 If the truss can be lowered, fixtures can be clamped on directly from the double flight case. If the fixture must
be lifted, block access under the work area. Working safely from a stable platform, hang the fixture on the truss with the arrow towards the area to be illuminated. Tighten the rigging clamps.
5 Install a safety wire that can bear at least 10 times the weight of the fixture. The attachment point is
designed to fit a caribiner clamp.
6 Verify that the pan and tilt locks are released. Verify that there are no combustible materials or surfaces to
be illuminated within 1 meter of the fixture, and that there are no flammable materials nearby.
256
256
256
256
Figure 10: Clamp bracket positions
FRONT
Figure 11: Rigging hardware installation
Loading...
+ 27 hidden pages