Martin Imager Operator's Manual

Page 1
martinarchitectural
Imager Series
user manual
Page 2
Measurements are in millimeters
205
200
242
108
432
607
656
482
497
227
432
294
138
261
© 2003-2004 Martin Professional A/S, Denmark.
All rights reserved. No part of this manual may be reproduced, in any form or by any means , with-
out permission in writing from Martin Professional A/S, Denmark.
P/N 35000127, Rev B
Page 3
SECTION 1. GETTING STARTED........................................5
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Task checklist. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Configuration overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Mounting orientation and location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Data linking multiple fixtures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Replacing the Imager J-Box cover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Adjusting the projection angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
GENERAL OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
External control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Stand-Alone programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
SECTION 2. STAND-ALONE OPERATION .........................25
STAND-ALONE PROGRAMMING OVERVIEW . . . . . . . . . . . . . . . . . . 26
About scene timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Synchronizing scene changes for multiple Imagers. . . . . . . . . . . . . . . . . .27
Programming methods. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
PROGRAMMING USING THE OPTIONAL INFRARED REMOTE CONTROL29
Before you begin programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Remote control commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
STAND-ALONE SHOW PLAYBACK . . . . . . . . . . . . . . . . . . . . . . . . . 33
Starting show playback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Show Execution with the IR remote control . . . . . . . . . . . . . . . . . . . . . . . . 33
Scene execution Using the optional MC-X. . . . . . . . . . . . . . . . . . . . . . . . . 34
DMX controller override during Stand-Alone show playback. . . . . . . . . . . 34
SYNCHRONOUS TRIGGERING DURING STAND-ALONE OPERATION . 35
SECTION 3. DMX CONTROL .......................................... 37
DMX CONTROLLER OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . 38
3
Page 4
Connecting a DMX control device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Set the appropriate DMX mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Control address selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Disable Stand-Alone operation (if required). . . . . . . . . . . . . . . . . . . . . . . .39
Lamp control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Effects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
SECTION 4. OPTICS AND PROJECTION ACCESSORIES......43
GOBOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Image projection size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Custom gobos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Replacing a gobo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Imager 04 DMX Gobo Wheel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
LENS OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Changing the lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
MOVING MIRROR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
SECTION 5. SERVICE AND TROUBLESHOOTING ...............55
SERVICE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Lamp replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Firmware updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
PRINTED CIRCUIT BOARD LAYOUT . . . . . . . . . . . . . . . . . . . . . . . . .61
ROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
T
Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
SECTION 6. REFERENCE................................................65
CONTROL MENU STRUCTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
DMX
PROTOCOLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Imager 04 DMX-Gobo Wheel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Imager 04 DMX-Gobo Wheel with moving-mirror fitted . . . . . . . . . . . . . . . 72
Imager 01 DMX-Gobo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Imager 01 DMX-Gobo with moving-mirror fitted. . . . . . . . . . . . . . . . . . . . .76
SPECIFICATIONS - IMAGER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
4
Page 5
S
ECTION
1. G
ETTING STARTED
5
Page 6

Introduction

Thank you for selecting the Martin Imager. The Imager is a series of luminaires designed for high resolution projection of patterns, images, logos and messages. Imager luminaires are dedicated projectors suited to l ow­maintenance installations.
The Imager product range is made up of a number of luminaires and accessories:
• Imager 04 DMX Gobo Wheel - a DMX controlled four-gobo projector
• Imager 01 DMX Gobo - a DMX controlled single gobo projector
• Imager Base - provides power to a single Imager luminaire
• Moving mirror for Imager Imager luminaires use a 250W discharge lamp. Three available lens options
offer the choice of narrow, medium and wide beam angles. DMX control enables remote focus and control of effects. For colored projections there is a simple slot for easy-to-replace color filters.The Imager is also equipped with a dimming system designed to create gentle fades and transitions.
The optional moving mirror provides programmable movement, useful for roving logos or gliding messages. This attachment creates the possibility of precise, smooth movement in a range of 235° of pan by 65° of tilt. Fixture settings are controlled via a 3-digit control panel or with an optional infra red remote control.

Safety information

Warning! This product is for professional use only. It is not intended for
use in a dwelling.
This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radiation, lamp explosion, and falls. Read this manual before powering or installing the fixture, follow the safety precautions listed below and observe all warnings in this manual and on the fixture. If you have questions about how to operate the fixture safely, please contact your Martin dealer or call the Martin 24-hour service hotline at +45 70 200 201.
6Introduction
Page 7
Protection from electric shock
• Disconnect the fixture from AC power before removing or installing the lamp, fuses, or any part, and when not in use.
• Always ground (earth) the fixture electrically.
• Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protection.
• Do not expose the fixture to rain or moisture.
• Refer all service to a Martin service technician.
Protection from UV radiation and lamp explosion
• Never operate the fixture with missing or damaged lenses and/or covers.
• When replacing the lamp, allow the fixture to cool for at least 30 minutes before opening the fixture or removing the lamp. Protect your hands and eyes with gloves and safety glasses.
• Do not stare directly into the light. Never look at an exposed lamp while it is lit.
• Replace the lamp if it becomes defective or worn out.
• Replace any cracked protective shields.
Protection from burns and fire
Warning The exterior of the fixture can reach temperatures up to 100° C
(212° F) at room temperature (25° C / 77° F). Allow the fixture to cool for 30 minutes before handling.
• Never attempt to bypass the thermostatic switch or fuses. Always replace defective fuses with ones of the specified type and rating.
• Keep all combustible materials (for example fabric, wood, paper) at least 1 meters (39 inches) away from the Imager luminaire.
• Do not illuminate surfaces within 0.5 meters (20 inches) of the fixture.
• Provide a minimum clearance of 0.1 meters (4 inches) around fans and air vents.
• Never place filters or other materials over the lens.
• Do not modify the fixture or install other than genuine Martin parts.
• Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
Protection from injury due to falls
• When suspending the fixture above ground level, verify that the structure can hold at least 10 times the weight of all installed devices.
• Verify that all external covers and rigging hardware are securely fastened
• Block access below the work area whenever servicing, installing or removing the fixture.
Introduction 7
Page 8

Task checklist

Task See
Install Imager Base Imager Base user
Unpack and check all parts are included page 9 Install any optical options such as gobos, lens, filters, or a
moving mirror. Install Imager J-Box and connect it to Imager Base page 12 Choose a location and connect Imager to J-Box page 13 Create data link if using multiple fixtures page 16 Set Imager personalities using the control menus page 20
When DMX control device is used
Connect DMX control device (if used) page 38 Using the control menus, set Imager profile option to “d1”
or “d2” and set the DMX address Program show, or use live control, with DMX control device page 40
When stand-alone program is used (not available in software Version 1)
If optional IR is used:
• Ensure data link not terminated page 29
• If this is the first fixture in the data link, install the optional IR receiver
• Set fixture IR address page 20
If synchronous triggering of multiple fixtures is to be used, set triggering options (is the fixture receiving or sending scene change triggers?)
Create stand-alone program, using:
• MP-2 Upload device, or the page 29
• Optional IR remote control page 29
Run stand alone program page 33
manual (P/N
35000128)
page 43
page 20 and page 39
page 30
page 27
8Introduction
Page 9

Installation

This section describes in general terms how to mount the fixture and connect it to data and power. These procedures shall be performed by qualified professionals.
Note This product must be installed in accordance with the
applicable installation code by a person familiar with the construction and operation of this product and the hazards involved.

Unpacking

The Imager comes with the following items:
• OSRAM HSD 250/80 lamp (installed)
• User manual
• Beacon gobo (pre-installed)
• Four cable glands
• Imager J-box (with terminator pre-installed)
• 2.5 mm Allen key/hex wrench
• 4 rubber cable-glands
•J-Box
Installation 9
Page 10

Configuration overview

The Imager is designed to be attached to a ceiling mounted Imager J-Box.
The J-Box is connected to a controlling device and po wer. An Imager Base supplies power to the Imager (via the J-Box).
The Imager is controlled via one of the following methods:
• DMX control device (such as a DMX controller or DMX recorder) which sends control signals in real-time
• Martin MC-X remote control to trigger a pre-programmed stand-alone show
• Martin Infrared receiver and remote control transmitter (to program and run stand-alone shows)
Via a CA T5 data network, a single Imager running a pre-programmed stand­alone show can trigger scene changes in other Imager luminaires (or in Martin Alien 02 or Martin MiniMac Maestro luminaires).

Prerequisites

Tasks
The procedures described here assume the that Imager Base has been installed and power cables have been run from it to the position where the Imager luminaire will be installed. This is recommended, but not required. If you perform the procedures in a different order, then keep thi s in mi nd w hen reading the instructions supplied here.
10 Installation
Page 11
Required tools
To install the Imager luminaire you will need the following items which are not supplied with the product:
• Four units of 6 mm mounting hardware appropriate to the mounting surface and appropriate to the approximately 11.6 kg (25.6 lbs) combined weight of the Imager J-Box and the Imager luminaire.
• Associated tools to install the mounting hardware
• Small flat head screwdriver
• 2.5 mm Allen key/hex wrench
• Box-cutter/razor knife
• CAT5 data cable (see “Creating a data link” on page 16)
Installation 11
Page 12

Power

Power is supplied from an Imager Base via the Imager J-Box. They are connected using the following two cables (not supplied):
• Lamp power out cable - 5 x 1 mm2 (AWG 18)
• Low voltage output cable - 4 x 0.75 mm2 (AWG 18) This product must be mounted or supported independently of an outl et bo x.
During installation of this equipment consult a qualified electrician to ensure correct branch circuit conductor.

Mounting orientation and location

Do not locate the Imager luminaire in an unventilated space. Install the fixture in a location where it is:
• at least 0.5 meters (20 inches) away from the surface to be illuminated,
• at least 1 meter (40 inches) away from any combustible materials, and
• away from accidental public contact.
Installing the J-Box
All Imager luminaires must be mounted using an Imager J-Box. Securely fasten the J-Box to a ceiling surface using 4 units of 6 mm (1/4 in.) mounting hardware appropriate to the mounting surface and appropriate to the combined weight of the J-Box and the Imager.
12 Installation
Page 13
The following is an overview of the inside of the J-Box.
Power cables for lamp and motor functions
Imager Base
(supplying power to one Imager)
Other luminaires on the data netw o rk
Attaching the Imager to a J-Box
To attach the Imager to a J-Box:
1 Remove the J-Box cover by loosing the 3 Allen screws around the rim with a
2.5 mm Allen wrench.
2 Using the 2.5 mm Allen wrench to loose the two locking screws, remove the
slotted section of the J-Box (indicated in grey).
RJ-45 connectors for data
DMX controller, MC-X,
or IR-receiver
Installation 13
Page 14
3 Pass the cables and mounting flange of the Imager though the center of the
J-Box cover.
4 Slide the flange of the Imager into the slot on the J-Box. Replace the slotted
section.
5 Move the Imager to the correct pan position and screw the locking screws in
place using the 3 mm Allen wrench.
6 Connect the power cables running from the Imager Base to the clamp
terminals in the Imager.
14 Installation
Page 15
The following illustration shows the correlation between the clamp terminals
10.5
Volt
24 Volt
Lamp
N.
Rel.
PCB
Lamp
L.
in the Imager Base and those in the Imager luminaire’s J-Box.
Clamp terminals on Imager Base
10.5 Volt
2
3
1
Clamp terminals in Imager J-Box
24 Volt
Lamp L.
Ground
7
6
2
1
8
Rel. PCB
9
Lamp
Mains
Neutral
9
8
Ground
Live
7
6
5
Lamp N.
4
5
4
3
Installation 15
Page 16
7 Clamp the ground wire running from the luminaire to the green terminal (at
position 6) to the J-Box using the screw provided (illustrated here).
8 Push the clamp terminals in the J-Box into the holes that are provided so
that they click into place.
9 Connect the data cable from the Imager
luminaire to the data connector in the J-Box. This can be found just behind the RJ-45 connectors.
10 Perform any necessary steps in “Data linking
multiple fixtures”.

Data linking multiple fixtures

You need to create a data link if you are going to be:
• Operating multiple Imagers in a synchronous way
• Controlling more than one fixture via a DMX control device
• Programming multiple fixtures via the IR receiver and IR remote control
Creating a data link
The data transmission rate (250 kbits/s) used by DMX512 requires the selection of a cable which does not significantly distort the signal or give rise to spurious signal reflections. Cables intended for use with audio systems (microphone cables), while having the convenience of flexibility, availability and relative low cost, are NOT suitable for use with DMX512 because of their high capacitance and incorrect characteristic impedance; at DMX512 data rates this will give rise to bit time distortion and signal reflections/overshoot.
16 Installation
Page 17
Cabling systems shall provide a balanced, nominal 120 ohm terminated transmission line, and be made of cables with a cha ra c teristic impedance in the range 100-120 ohms.
Note: Mixing cables of different impedances and other characteristics
not isolated by buffers or other processing devices may affect system reliability.
Always use solid or stranded shielded-twisted pair/foiled twisted pair (STP/FTP), 100 or 120 ohm cables that conform to ISO IEC 11801 category 5 or higher with RJ-45 connectors wired as follows
Pair Wire # Color Function DMX512 Pin
Pair 2 1 white /
data 1 + DMX512 Pin 3
orange
2 orange data 1 - DMX512 Pin 2
Pair 3 3 white / green data 2 + DMX512 Pin 5
4 green data 2 - DMX512 Pin 4
Pair 1 5 blue Not assigned
6 white / blue Not assigned
Pair 4 7 white / brown Signal Common (0 v) DMX512 Pin 1
8 brown Signal Common (0 v) DMX512 Pin 1
Shield drain
The minimum wire size is 0.2 mm (24 AWG) for runs up to 300 meters (1000 ft.) and 0.322 mm (26 AWG) for runs up 500 meters (1640 ft.). Your Martin dealer can supply the right cable in various lengths.
The: RJ-45 sockets in the Imager J-Box are wired as follows - pins 7 & 8 to ground, pin 2 to signal - (cold), and pin 1 to signal + (hot).
Creating the data link
1 Connect one of the RJ-45 connectors in
the J-Box to a DMX control device, or one of the RJ-45 connectors in the next J-Box.
2 Continue connecting fixtures output to
input. Up to 32 devices may be connected on a serial link. A termination plug is pre-installed and may need to be removed if you are connecting the fixture to a subsequent fixture on a network.
Installation 17
Page 18
3 If you are not using the infrared remote control and receiver, ensure that the
the link is terminated with an RJ-45 termination plug (one is supplied and pre-installed in the J-Box) into the DMX data output of the last J-Box.
Warning If you are using Stand-Alone programs (see “Stand-Alone
programming overview” on page 26) on multiple fixtures on a data link and you experience random “flicker” or other unexplained control problems, insert a female termination plug (P/N 91613018) into the last fixture on the data link.

Replacing the Imager J-Box cover

1 Four holes, for cabling, are semi-
stamped in the side of the J-Box cover. If these are needed, take a pair of needle-nose pliers and break the metal stamps out of the cover. Place the supplied cable glands over the cables and push them into the holes in the junction-box cover.
2 Before closing the J-Box ensure that the power and data network cables
(“Data linking multiple fixtures” on page 16) are attached to the terminals.
3 Push the Imager J-Box cover into place. 4 Using the 2.5 mm Allen wrench, tighten the three Allen screws that hold the
cover in position.

Adjusting the projection angle

You can adjust the angle of the luminaire by making adjustments at the joints. To adjust a joint, use the 6 mm Allen wrench to loosen th e joints on either side of the fixture. Adjust to the desired angle and re-tighten.
18 Installation
Page 19

General operation

When the Imager is connected to power it will reset. After a few seconds the following text appear in the control panel display:
1 IM, followed by 2 VER, followed by 3 the version number of the installed software, followed by 4rst
When the reset is completed the fixture DMX address will appear in the control panel display.

External control

The Imager can be controlled with DMX signals from a DMX control device such as a DMX recorder or DMX controller. This is described in “Section 3. DMX control” on page 37.

Stand-Alone programming

Using stand-alone programming, there are two ways of programming and storing a show in the fixture itself:
• Via an MP-2 Uploader, or
• Using the optional IR remote control (that communicates with the optional IR receiver mounted on the first fixture in a data link). This method is popular for installations of up to 10 fixtures because access to the various functions is faster, and because multiple fixtures can be simultaneously selected and programmed from a single IR remote control unit (this potentially time­saving method is known as IR Stand-Alone). If you have any MiniMac Maestro or Alien 02 luminaires installed on the data link you can also use this method to program them.
Stand-Alone programming is described in “Section 2. Stand-Alone operation” on page 25.
General operation 19
Page 20

Control panel

The control panel is used to set the fixture address and other settings. It can also be used to operate the fixture in a limited way manually for testing and service purposes.
The control panel will (by default in the personality settings) be deactivated and switch off after 2 minutes if no buttons are pressed. When inactive error messages will still be displayed (provided that this has not been deactivated in the fixture personality settings). To reactivate the display press one of the buttons for two seconds and release it.
Navigating the control menu
The control panel displays the fixture address at the top of the menu. If there are any error messages these are displayed as well. To get to the top of the menu, press [menu] repeatedly. From the top, press [menu] to enter the main menu. Press [up] or [down] to scroll through menus and press [enter] to view submenus. To activate a setting or function, press [enter]. To return to the previous menu or to escape without making a selection, press [menu].
Inverting the display
Press [up] and [down] at the same time.

Menus

The control panel menu is detailed in “Control menu structure” on page 66. They are described at a high level here.
Address menu (Adr)
Depending on the setting in the Profile menu (see “Profile menu (Pro)” on page 21) the Address menu is used to set either a:
• DMX control address (1-512), where a fixture will be controlled by DMX signals from a DMX control device.
• IR fixture ID number (0-9), where a fixture will be programmed using an IR remote control.
20 General operation
Page 21
Profile menu (Pro)
The Profile menu contains options where you can specify if the fixture is:
• Using the IR remote control system and has the IR received installed (option rCS), or
• Using the IR remote control system and does not have the IR receiver installed (option rCr), or
• Not using the IR remote system (options d1 or d2). Always specify one of these when the optional IR remote control system is not in use:
DMX mode 1 uses 9 channels and does not allow fine adjustment of movement and effects.
DMX mode 2, which is the default, uses 12 channels and allows fine adjustment of movement and effects.
Stand-alone menu (SA)
The Stand-Alone menu commands can be used to execute scenes in S t and­Alone mode. See “Programming using the optional infrared remote control” on page 29 for further information.
Adjustment menu (Adj)
The Adjustment menu (AdJ) provides manual control for service use.
Personality menu (Per)
The Personality menu sets some basic characteristics, or the personality, that the fixture has.
Lamp-off and reset
These options enable you to disable the lamp-off and reset commands that are used on DMX channel 1. This might be useful if you are using a DMX control device with your Imager, because it reduces the chance of accidently selecting lamp-off on channel 1 during a show. The default is that these commands are enabled.
Note that the lamp must be allowed to cool for at least 6 minutes after turning it off before it can be re-struck. A 6-minute hot-restrike delay is programmed into the Imager software from the time that the light is extinguished, or the power is switched off, to ensure that this occurs. If you attempt to strike the lamp and do not succeed the fixture will reattempt to strike itself after 6 minutes (and a hot lamp warning/error will appear in the display), unless you issue the lamp off command. If the fixture fails these two attempts to strike, the lamp will be assumed to be defective and the L E (lamp error) message will appear.
General operation 21
Page 22
Automatic lamp-on
When enabled, this will strike the lamp automatically within 90 seconds of applying power to the fixture. By default this is set to
Off.
Display
Turn off the display 2 minutes after the last key press or leave it on. This setting will be overridden by error and warning messages. By default this option is on.
Store remote status (SrS)
This SRS option is only relevant when you are using the optional infrared remote control and receiver. If SRS is:
• On (default), and you start or stop the programmed show using the IR remote control, the fixture will additionally be set to automatically start or stop the show next time it is powered on.
• Off, the IR remote control has no influence over the automatic starting of a programmed show at power-on. This is controlled by the menu (see “Starting show playback” on page 33).
SA / Run
Enable lamp off control from an MC-X
When using an MC-X control device to select and run scenes, button 7 can be used to turn the lamp off. By default this option is off.
The lamp must be allowed to cool for at least 6 minutes after turning it off before it can be re-struck. A 6-minute hot-restrike delay is programmed into the Imager software from the time that the light is extinguished, or the power is switched off, to ensure that this occurs. If you attempt to strike the lamp and do not succeed the fixture will reattempt to strike itself after 6 minutes (and a hot lamp warning/error will appear in the display), unless you issue the lamp off command. If the fixture fails these two attempts to strike, the lamp will be assumed to be defective and the L E (lamp error) messag e will appear.
Errors and warnings message toggle
This enables error and warning messages to be supp ressed. This enables , for example, the continued programming of a fixture that has a non-critical error. The default setting is On, which means that errors messages will not be suppressed and can be seen, when active, at the top level of the control menu structure.
22 General operation
Page 23
Lamp Temperature fan regulation
Allows the lamp fan in a Imager to be automatically adjusted based on the temperature. This is on by default.
Gobo Temperature fan regulation
Allows the gobo fan in a Imager to be automatically adjusted based on the temperature. This is on by default.
Temperature warnings enabled
Enables temperature warnings to appear in the display and shut down the lamp.
Lamp hour warning
Using this menu you can enable or disable lamp life warnings and set the number of hours of expected life that apply to the lamp type installed. A counter operates that can be read and reset in the resettable lamp hour counter reaches:
• 100 hours less than the predefined lamp hour warning level, the display will start blinking ‘Lhu’ in the display. At this point you should change the lamp to avoid the risk of lamp explosion.
• The predefined lamp hour warning level, the lamp shuts off and can not be turned on again before the counter is reset, or the predefined lamp hour warning level has been redefined.
This is option is off by default. We recommend that you activate the Lamp Hour Warning function on the Imager and that you set the expected number of hours of life the lamp has. Remember to also reset the lamp hour counter using the Information menu.
Inf menu. When the
Note that because the display is limited to 3 digits, and many lamps have a life that is measured in thousands of hours, the counters are set to 1/100ths of their actual value. For example for a lamp that has a life of 3000 hours, the lamp hour warning level would be set to 30.
Restore factory defaults
Restores factory default settings in the Personality menu.
Reset all counters
Resets all resettable counters (these are found under the Information menu).
General operation 23
Page 24
Information menu (INF)
The Imager provides reado uts to track usage, tem perature, mainten ance intervals, lamp life, and software version. Values from 1000 to 9999 are automatically scrolled and counters roll over to 0 after 9,999.
Displaying or resetting a counter
Scroll to Inf in the main menu, press [enter] and scroll to the desired readout. Press [enter] and scroll to the desired option. Press [enter] to display the information.
Note that the resettable counters ( zero by pressing and holding [up] for ap proximately 5 seconds, until th e readout displays
Utility menu (UtI)
The Utility Menu is used to set the fixture into Boot Upload Mode. See “Firmware updates” on page 58.
Test menu (tSt)
This is used by Martin service personal to test the printed circuit board.
rES) in the Inf menu can be set to
0.
24 General operation
Page 25
S
ECTION
2. S
TAND
OPERATION
-A
LONE
General operation 25
Page 26
Stand-Alone
S
c
e
n
e
1
S
c
e
n
e
3
S
c
e
n
e
2
programming overview
In stand-alone mode, individual Imagers can be programmed to run a show of up to 20 scenes without an external controller. This can be done using the control panel or the optional IR remote control system.
The Imager will run its show in a continuous loop. Multiple Imagers on a data link all have their own shows individually
programmed, but can have scenes synchronously triggered by a one fixture on the data link.

About scene timing

Each scene has a dynamic part - the fade - during which effects move to the scene’s programmed positions, and a static part - the wait - where effects do not change.
The duration of the fade and wait is programmed individually for each scene. The fade time may be 0 - 120 seconds; the wait time may be 0 - 12 hours. The total time it

26 Stand-Alone programming overview

takes a scene to execute is the sum of the fade and wait times.
When operating multiple fixtures synchronously, the wait time is determined by the fixture that issues scene change commands. It does this when it reaches the end of each scene wait time. Every other fixture fades and waits at the its own rate and then remains in the “wait state” until receiving a start scene xx command. When programming in synchronous triggering situations, keep in mind that in order to keep things as simple as possible
c
S
3
e
n
e
Wait
Fade
Wait
S
c
e
Fade
n
e
1
Wait
Fade
S
c
e
n
e
2
Page 27
there are two rules of thumb that will make life much easier; try to ensure that:
1 Every fixture has the same number of scenes. 2 Respective scene times are a few seconds longer on the fixture that issues
triggering commands. The rules used in the algorithm are detailed in “Synchro nous triggering
during Stand-Alone operation” on page 35.

Synchronizing scene changes for multiple Imagers

In situations where you are running multiple Imagers on a data link it is possible to synchronize scene changes. Read this section if this applies in your case.
It is important to note that each individual fixture must be programmed with a show and that the only commands that are passed are scene change commands. No data about the look of the scene is passed between fixtures.
Setting synchronized triggering options
1 Scroll to SA in the top level of the menus on the control panel and press
[enter].
2 Scroll to
SAE and press [enter].
3 Select:
Sin If the fixture will operate in isolation (with no
Snd If the fixture will send scene triggering signals to the
Syn If the fixture should “listen” for scene trigger signals on
4 Press [enter].
synchronous triggering). This is the factory default setting.
other Imagers on the data link.
the data link.

Programming methods

The Imager provides two stand-alone programming methods; using the:
Stand-Alone programming overview 27
Page 28
• MP-2 Upload device. See the MP-2 user manual for further information, or an
• Optional infrared remote control and infrared receiver. Using this method you can simultaneously select and program up to ten Imager fixtures on a single data link using a handheld remote. This method can save time programming individual fixtures. See “Programming using the optional infrared remote control” on page 29 for further information.
28 Stand-Alone programming overview
Page 29

Programming using the optional infrared remote control

Programming can be performed using an optional infrared transmitter and receiver system that are orderable from your Martin dealer. Infrared programming can be performed for a single fixture, or up to 10 fixtures on a data link.
The optional IR remote control device can be used to program 20 scenes that make up a show. Note that:
• Every fixture can have up to 20 on-board scenes with individual fade & wait times.
• Scenes are numbered from 0 to 19.
• A scene contains a fade-section where the fixture shifts to the scene, followed by a wait-section where the scene effect is shown.
• Programming using the IR remote control is easiest when the display on the Imager control panel can be seen.
You can also program any Alien 02 or MiniMAC Maestro fixtures on the same data link. Refer to the respective user manuals for further information.
Note that it is always possible to perform stand-alone programming using an MP-2 uploading device (refer to the MP-2 user manual for more information).

Before you begin programming

If you are running multiple fixtures, ensure that:
• Y ou have established a data link (see “Data linking multiple fixtures” on page
16) and that the IR-receiver is connected to the data link (you may need an XLR-RJ-45 converter to do this) and installed in a line-of-site location.
•There is no termination plug in the last fixture in the data link.
Ensure the stand-alone program is not running
To stop the current stand-alone program running:
Programming using the optional infrared remote control 29
Page 30
1 Press [menu] to return to the top level of the menu. 2 Scroll to
[enter].
3 Scroll to
SA in the top level of the menus on the control panel and press
run and press [enter].
4 Scroll to 5 Press [menu] to return to the top level of the menu.
Off and press [enter].
Enabling infrared programming
Perform the following steps in this order:
1 Only the first fixture on the data link can have an IR receiver. Insert the
receiver module into the serial data In socket. Position the sensor arm as
desired but avoid turning it more than necessary. 2 From the top level of the menu, scroll to 3 If this fixture:
• Does not have the IR receiver installed, scroll to rCr. Press [enter].
• Has the IR receiver installed, scroll to
4 Press [menu] to return to the top level of the menu. 5 Select Adr and press [enter]. Select an IR fixture ad dress from 0 to 9 and
press [enter]. Note that if you have multiple fixtures that will run the same
stand-alone scenes it might be a good idea for them to share the same IR
fixture address. This will save time when programming, as they will all
receive and process the scene programming instructions simultaneously. 6 Press [menu] to return to the top level of the menu. 7 Stand 2 meters (6 ft.) away from the fixture, point the remote control at the
receiver, and press the lamp power button. If there is no response, try the ID
button. If there is still no response, reverse the sensor head by rotating the
sensor arm 180° and folding it over.
rCS. Press [enter].
Pro, press [enter].

Remote control commands

Important! The luminaire will acknowledge the receipt each valid IR
command with a slight change in intensity.
30 Programming using the optional infrared remote control
Page 31
Fixture selection
Each fixture must be assigned an address from 0 - 9 during setup so that it can be individually controlled with the remote control. Note that fixtures can share an address if they are to have the same program.
To select a fixture, press ID and enter its address using the number keys. Multiple fixtures may be selected by entering more than one address. For example, pressing [ID] [1] [2] [3] selects fixtures 1, 2, and 3.
Lamp power
The lamp power button toggles lamp power on and off on selected fixtures. The button must be held for 5 seconds to turn lamp power off. Note: Lamps cannot be turned off during scene execution and a discharge lamp must cool for several minutes after being turned off before it can be turned back on.
The lamp must be allowed to cool for at least 6 minutes after it is switched off before it can be re-struck. A 6-minute hot-restrike delay is programmed into the Imager software from the time that the light is extinguished, or the power is switched off, to ensure that this occurs. If you attempt to strike the lamp and do not succeed the fixture will reattempt to strike itself after 6 minutes (and a hot lamp warning/error will appear in the display), unless you issue the lamp off command. If the fixture fails these two attempts to strike, the lamp will be assumed to be defective and the LE (lamp error) message will appear.
Scene timing
Fade and wait times are set by pressing the scene timing buttons and entering the desired time in seconds using the number keys.
Scene Selection
Scenes are created, selected, saved, and deleted using the six scene keys. The current scene is displayed on the fixture display after the letter “ during editing and after the letter “P” or “S” (slave) during execution.
Programming using the optional infrared remote control 31
r
Page 32
Lamp power
Scene timing
Fixture selection
Position adjustment
Execution
Effects selection
Prev (previous scene) scrolls backwards through scenes on selected fixtures.
Next (next scene) scrolls forwards through scenes on selected fixtures.
Store (store scene) saves effect and timing settings to the current scene.
Delete (delete scene) removes the current scene from memory. Scenes above the deleted scene are renumbered.
INS (insert scene) creates and saves a new scene before the current scene, which moves up a number.
ADD (add scene) creates a new scene at the end of the sequence with the settings that are active when the scene is created.
Effects Adjustment
Scene selection
00 01 02
Store saves settings in the current scene.
00 01 02 03
Add saves settings in a new scene at the end of the sequence.
00 01 02 03
Insert saves settings in a new scene before the current scene.
The look of a scene is programmed by first selecting an option with the effect selection buttons and then adjusting the option with the position adjustment buttons. When two effects are assigned to a selection button, the up/down arrows control one effect and the left/right arrows control the other effect. If there is only one effect, the up/down arrows usually provide course adjustment and the left/right arrows usually provide fine adjustment. The middle button returns effects to a default position.
32 Programming using the optional infrared remote control
Page 33

Stand-Alone show playback

Starting show playback

1 From the top level of the control menu, scroll to SA and press [enter]. 2 Scroll to
[enter]. 3 Scroll to 4 Scroll to
When the show starts to run the current scene number will appear in the
control panel display (unless the PEr/dIS menu has been set to OFF, in
which case the display will switch off two minutes after the last key is
pressed).
Important! Execution of the pre-programmed scenes in a loop will
automatically resume when the fixture is powered-on if stand-
alone is enabled and the automatic lamp-on (PEr/ALO) function
is enabled (see “Automatic lamp-on” on page 22).
SA in the top level of the menus on the control panel and press
run and press [enter]. On and press [enter].
Show Execution with the IR remote
control
The Run/Stop button on the IR remote control toggles scene execution
on/off on fixtures that are selected (see“Fixture s election” on page 31).
Scenes execute in a continuous ascending loop.
All remote control functions except Run/Stop are disabled during show
execution.
If the Store Remote Status option (see “Store remote status (SrS)” on page
22) is enabled, then the Run/Stop button will also toggle the
option to OFF or On, so that next time the fixture is powered on it will
automatically start (or not start) the Stand-Alone show.
Stand-Alone show playback 33
SA / run
Page 34

Scene execution Using the optional MC-X

The MC-X is an optional remote control unit that is avai lable from Martin. Once the remote controller is connected, 7 scenes can be conveniently called up on the MC-X's buttons.
To enable control:
1 Connect the MC-X controller to the Imager’s data network via an XLR-to-RJ-
45 adaptor. If multiple Imagers are connected, plug the controller into the first fixture in the link.
2 On each fixture, select
exit the
3 On each fixture, select
the 4 To trigger scenes 00-06, press the numbered preset buttons on the MC-X. 5 To have each fixture run its own routine, press [Auto].
SA menu.
Pro menu.
SA / run / OFF and press [enter]. Press [menu] to
Pro / d1 and press [enter]. Press [menu] to exit
Using the
control the lamp off function. See “Control menu structure ” on page 66.
PEr / nnO menu it is possible to set button 7 on the MC-X to
DMX controller override during
Stand-Alone show playback
If an Imager is connected to a DMX controller and receives DMX signals
during show playback, the Stand-Alone show will stop running and the
fixture will respond to the DMX controller. DMX signals always have priority
over the running of a Stand-Alone show.
34 Stand-Alone show playback
Page 35

Synchronous triggering during Stand-Alone operation

Note This chapter details the rules that are used in Stand-Alone
synchronous triggering. It is not necessary to read this chapter unless you require help with problem diagnosis or unless you otherwise need a detailed understanding of the algorithm used for synchronous triggering.
The rules are as follows:
1 Every fixture can have up to 20 on-board scenes with i ndividual fade and
wait times. 2 Scenes are numbered from 0 to 19. 3 A scene contains a fade-section, followed by a wait-section. 4 When running "synchronous triggering" one Imager issues commands to
the other Imagers to "go to scene xx", where xx is the scene number that
master will execute next. 5 If a slave has fewer scenes than the master, it will derive which scene to go
to by dividing the number of the scene it has been commanded to go to
(scene 5, for example) by the total number of scenes that the slave fixture
has (4, for example) in whole numbers (no decimal places). In this example
5 divided by 4 results in 1, with 1 remainder. This remainder will be the
number of the scene that the slave fixture starts - scene 1. Generall y
though, when a Slave fixture reaches its own last scene before the Master
fixture, a "go to scene x" message will result in the first scene being played.
Synchronous triggering during Stand-Alone operation 35
Page 36
6 If a slave has more scenes than the master calls, the last scenes in the
slave will never be executed, as is the case with scene S4 in the following example.
F=fade, W=wait Timeline =>
M0 M1 M2 M3
Programmed in Master F W F W F W F W
S0 S1 S2 S3 S4
Programmed in Slave F W F W F W F W F W
Result M0 M1 M2 M3
FW FWF WFW S0 S1 S2 S3 FW FW FW ----F W
7 A slave fixture will not listen for the next message from the master fixture
before it has finished its current scene. This may result in a slave skipping a scene if slave has a longer scene time than master. Note that in the following example the scenes in the Sl ave run out of their programme d sequence because scenes 0 and 2 on the Slave are longer than the corresponding scenes on the Master.
M=master, S=slave F=fade, W=wait Time >
Programmed M0 M1 M2 Master F W F W F W
Slave F W F W F W
S0 S1 S2
Result M0 M1 M2 M0 M1 Master F W F W F W F W F W
Slave F W F W .. .. FW .. ..
S0 S2 S1
36 Synchronous triggering during Stand-Alone operation
Page 37
S
ECTION
3. DMX
CONTROL
Synchronous triggering during Stand-Alone operation 37
Page 38

DMX Controller operation

The Imager may be programmed and operated with any lighting control device that is compatible with the USITT DMX standard. This section describes how to operate the system with a controller.
See the appropriate section for specific control values for your Imager model:
• “Imager 04 DMX-Gobo Wheel” on page 71.
• “Imager 04 DMX-Gobo Wheel with moving-mirror fitted” on page 72.
• “Imager 01 DMX-Gobo” on page 74.
• “Imager 01 DMX-Gobo with moving-mirror fitted” on page 76.

Connecting a DMX control device

Connect a data cable from the Imager J-Box to the control device’s data output. If the control device does not have an RJ-45 socket then you may need to purchase or wire an XLR-to-RJ45 converter. For wiring information see “Creating a data link” on page 16.

Set the appropriate DMX mode

There are two DMX modes:
DMX mode 1 uses 9 channels and does not allow fine adjustment of movement and effects.
DMX mode 2, which is the default, uses 12 channels and allows fine adjustment of movement and effects.
The mode that is used is specified using the Profile menu in the control panel (see “Control menu structure” on page 66.
38 DMX Controller operation
Page 39

Control address selection

The Imager requires 9-12 DMX control channels (depe nding on the DMX mode that is selected). The DMX address, also known as the start channel, is the first control channel used. It is a logical address to which control instructions are sent. In this way a controller, can send instructions to a fixture, or fixtures, at a particular address. For example when using nine channels of control data (DMX mode 1), the Imager reads the data on the start channel (DMX address) and the next eight channels. If the DMX address is set to 100, the Imager uses channels 100, 101, 102, 103, 104, 105, 106, 107 and 108.
Be sure to allow adequate channels when setting the control address. If control channels for one fixture overlap control channels for another fixture, then one of the fixtures will receive the wrong commands. Two Imagers may share the same address if they are to respond identically. They will receive the same commands and individual control will be impossible.
The default factory set control address is ‘1’.
Setting the control address
1 Scroll to Pro in the top level of the menus on the control panel and press
[enter]. 2 Select d1 or d2 to enable DMX control. Press [enter]. 3 Press [menu] to return to the top level of the menu. 4 Scroll to
[enter]. The current address is displayed. 5 Scroll to the address that is assigned to the fixture on the controller. Press
[enter] to activate the address setting.
Adr in the top level of the menus on the control panel and press
Disable Stand-Alone operation (if
required)
DMX control always overrides any Stand-Alone show that is running, but if
Stand-Alone mode is enabled and no DMX signal is received, the Imager
will attempt to run any show in its memory. To prevent this: 1 Press [menu] to return to the top level of the menu.
2 Scroll to
[enter].
SA in the top level of the menus on the control panel and press
DMX Controller operation 39
Page 40
3 Scroll to run and press [enter]. 4 Scroll to
Off and press [enter].

Lamp control

Important Avoid striking several lamps at once!
The lamp can be turned on and off from the controller using the lamp-on and lamp-off commands on channel 1. To prevent accidental lamp-off commands, lamp off can be partially disabled from the using the
LOF
menu on the control panel (see “Control menu structure” on page 66). If the DMX Lamp-off personality is off, the lamp-off command on channel 1 executes only on an:
• Imager DMX Gobo Wheel, if gobo position 4 is selected (either in indexed or continuous rotation) and the focus is set to the near position.
• Imager DMX Gobo, if DMX-channel 3 is set to a value of 60-79 or 140-159, and the focus is set to the near position.
Strike lamps one at a time at 5 second intervals. Striking many lamps at once may cause a voltage drop large enough to prevent lamps from striking, damage electronics, and trip circuit breakers. To have the lamp strike automatically at power-up, set the Automatic Lamp-on personality to on (see “Personality menu (Per)” on page 21).
PEr /
The lamp must be allowed to cool for at least 6 minutes after turning it off before it can be re-struck. A 6-minute hot-restrike delay is programmed into the Imager software from the time that the light is extinguished, or the power is switched off, to ensure that this occurs. If you attempt to strike the lamp and do not succeed the fixture will reattempt to strike itself after 6 minutes (and a hot lamp warning/error will appear in the display), unless you issue the lamp off command. If the fixture fails these two attempts to strike, the lamp will be assumed to be defective and the L E (lamp error) messag e will appear.

Effects

The mechanical effects reset to their home positions when the fixture is powered on. Effects can also be reset from the controller on channel 1. If the DMX Reset personality is off, the reset command on channel 1 will only execute on an
40 DMX Controller operation
Page 41
• Imager DMX Gobo Wheel only if gobo position 4 is selected (either in indexed or continuous rotation) and the focus is set to the near position.
• Imager DMX Gobo only if DMX-channel 3 is set to a value of 60-79 or 140­159, and the focus is set to the near position.
Note that use of DMX mode 2 provides for fine positioning control of effects. See “Set the appropriate DMX mode” on page 38.
Intensity
The fixture provides smooth, high resolution, full-range intensity control on channel 2.
Focus
The fixture provides focus control from 2 meters to infinity on channel 5 (DMX mode 1) or 6 (DMX mode 2).
Gobo effects
Gobo selection (for the Imager DMX Gobo Wheel), rotation and indexing control are available on channels 3 and 4 (DMX mode 1) or 3 to 5 (DMX mode 2).
Moving mirror control
Pan, tilt, and speed control of the optional moving mirror is available on channels 6 to 8 (DMX mode 1) or 7 to 11 (DMX mode 2).
The speed at which the mirror moves from one position to another, can be controlled in two ways known as tracking control and vector control. You may switch between tracking and vector control, but you cannot use both at the same time.
Tracking control is enabled by setting channel 8 (in DMX mode 1) or 11 (in DMX mode 2), to a decimal value from 0 to 2. Fades are then programmed using the controller’s cross-faders. The Imager has a digital filter algorithm that averages several updates to ensure smooth movement.
Vector control provides a way to program fades on controllers without cross­faders and may provide smoother fades than tracking control with some controllers, particularly on very slow fades. A vector speed is programmed by setting channel 8 (in DMX mode 1) or 11 (in DMX mode 2) to a decimal value from 3 (fastest) to 251 (slowest). When using vector control, the controller cross-fade time, if available, must be 0.
DMX Controller operation 41
Page 42
Blackout while moving
Image projection can be blacked out while effects or the mirror moves at maximum speed from one position to the other by setting channel 8 (in DMX mode 1) or 11 (in DMX mode 2) to a decimal value from 252 to 255.
42 DMX Controller operation
Page 43
S
ECTION
4. O
PTICS AND
PROJECTION ACCESSORIES
DMX Controller operation 43
Page 44

Gobos

The:
• Imager DMX Gobo Wheel accepts up to four metal or glass gobos
• Imager DMX Gobo accepts a single metal or glass gobo The gobos must be size D with an outside diameter of 53.3 mm 2.10 in.) and
a maximum image diameter of 40 mm (1.57 in.). The images can be rotated in both directions or set in an indexed position. A single Imager promotion gobo is factory installed.

Image projection size

To calculate the size of a projected image using a gobo of a given size, the formula is
projected image size
To calculate the gobo image size required to achieve a projected image size, the formula is
gobo image size
The focal length of the Imager will be one of the following:
• 150 mm (5.9 in.) for the optional 15° lens
• 100 mm (3.9 in.) for the standard 23° lens
• 70 mm (2.75 in.) for the optional 32° lens
gobo image size projected distance×
----------------------------------------------------------------------------------------=
projected size focal length×
------------------------------------------------------------------- -=
focal length
projected distance

Custom gobos

For optimum performance, custom glass gobos for the Imager should be made with the text, logo, and similar artwork reversed on the coated side (unless the moving mirror accessory is fitted as this will invert the gobo image that is projected).
44 Gobos
Page 45
Gobo orientation
The following illustrations show the correct orientation for different gobo types. When in doubt, install gobos with the more reflective side towards the lamp.
Uncoated side towards surfaceCoated side towards lamp
When an object is held up to the coated side there is no space between the object and its
Coated Glass Gobos
reflection. The back edge of the gobo cannot be seen when looking through the coated side.
Smooth side towards lamp
Textured Glass Gobos
Reflective side towards lamp Black side towards surface
Metal Gobos
Reversed image towards lamp
When an object is held up to the uncoated side there is a space between the object and its reflection. The back edge of the gobo can be seen when looking through the uncoated side.
T extured side towards surface
True image towards surface
Image/text Gobos
Gobos 45
Page 46

Replacing a gobo

Imager 01 DMX Gobo
1 Disconnect the fixture from AC power and allow it to cool for 15 minutes. 2 Remove the top cover of the fixture using a 2.5 mm Allen wrench.
3 Unscrew the thumb screw holding the gobo plate in place.
46 Gobos
Page 47
4 Remove the gobo plate from the fixture.
5 Squeeze the ends of the retention spring (inside the gobo holder) together
and remove. Push the existing gobo (if installed) out from the back and remove.
6 Orient the gobo as shown in “Custom gobos” on page 44 and insert the
replacement gobo into the holder. Secure the gobo with the retention spring. 7 Replace the gobo plate, screw it into place, an d replace the fixture cover. 8 Applying power.

Imager 04 DMX Gobo Wheel

1 Disconnect the fixture from AC power and allow it to cool for 5 minutes. 2 Rotate the gobo wheel to a position that allows you to access the gobo.
Gobos 47
Page 48
3 Using a small screwdriver if necessary, squeeze the ends of the retention
spring (inside the gobo holder) together and remove the existing gobo (if installed) and spring.
4 Orient the gobo as shown in “Custom gobos” on page 44 and insert the
replacement gobo into the holder. Secure the gobo with the retention spring.
5 Apply power.
48 Gobos
Page 49

Filters

A Slide Projection Kit (P/N 91611076), or hexagonal color filter can be
installed in the Imager. The holder slides out of the side of the fixture and is
held in place by a magnet.
The following filters are available (at the time of printing) from your Martin
dealer:
Lilac 503 P/N 46402000 Light Blue 102 P/N 46402001 Green 208 IAD P/N 46402002 Green 204 P/N 46402003 Orange 306M P/N 46402004 Red 308 P/N 46402005 Green 203 P/N 46402006 Blue 108 P/N 46402007 UV-transmitter P/N 46402008 Half Minus Green P/N 46402009 Heat filter (included in Slide
Projection Kit)
P/N 41102060
The number next to each color filter is an OCLI (Optical Coating Laboratory,
Inc.) reference number.
Filters 49
Page 50

Lens options

The following lenses are available for the Imager luminaire:
• 23° lens (fitted as standard)
• 15° lens (a screw on attachment) - P/N 91611074
• 32° lens (a screw on attachment) - P/N 91611075

Changing the lens

To change the lens:
1 Disconnect the fixture from AC power and allow it to cool for 30 minutes. 2 Remove the cover of the fixture using a 2.5 mm Allen wrench.
3 Rotate the spindle to move the standard lens as far away from the lamp as
possible.
4 Slide the optional lens in under the standard lens, and screw it to the thread
on the standard lens.
50 Lens options
Page 51
5 Adjust the position of the pin that functions as the mechanical stop to the
appropriate position.
o
23
15o lens position
standard position 32o lens position
Note that for the 32 degree lens the pin is removed and inserted from the
other side of the plate. 6 Replace the fixture cover and apply power.
Lens options 51
Page 52

Moving mirror

The optional moving mirror, enables programmable movement, useful for roving logos or gliding messages. It pr ovides smooth movement in a range of 235° of pan by 65° of tilt.
To install the moving mirror:
1 Disconnect the fixture from AC power and allow it to cool for 30 minutes. 2 Remove the cover of the fixture using a 2.5 mm Allen wrench.
3 Using a 2mm Allen wrench, loosen the 4 recessed Allen screws on the
spine of the fixture and remove the cover plate.
52 Moving mirror
Page 53
4 Slide the struts on the moving mirror into the
Imager. 5 Once in position lock the mirror into place by
tightening the 4 recessed Allen screws on the
spine of the fixture. 6 Attached the cable to the connector in the
Imager.
7 Place the cable so that it stays out of the optical path.
8 Replace the fixture cover and apply power.
Moving mirror 53
Page 54
54 Moving mirror
Page 55
S
ECTION
5. S
ERVICE AND
TROUBLESHOOTING
Moving mirror 55
Page 56

Service

This section describes service proced ures that can be performed by the user. Refer all service not described here to a qualified Martin technician.
CAUTION! R ISK OF SHOCK
Disconnect power before servicing. Replace all parts after servicing.
The exterior of the fixture can reach temperatures up to 80° C (176° F) when operating at room temperature (25° C / 77° F). Always allow the fixture to cool for 30 minutes before handling.

Lamp replacement

To ensure optimum lamp life:
• Turn off lamp power whenever illumination is not required for extended periods of an hour or more. Fixture power may remain on when not in use.
• Always allow the lamp to warm up fully before turning it off.
• Avoid turning on several lamps at once. The Imager can use the following discharge lamps. Installing any other lamp
type may damage the fixture.
Lamp CRI Color Temp. Average Life
Philips MSD 250 75 6700 K 3000 hours Philips MSD 250/2 65 8500 K 3000 hours Osram HSD 250/78 85 7800 K 3000 ho urs Osram HSD 250/60 85 6000 K 2000 hours Osram HSD 250/80 75-80 8000 K 3000 hours
To replace the lamp:
1 Disconnect the fixture from power and allow it to cool for 30 minutes before
removing the lamp cover.
56 Service
Page 57
2 Remove the two thumb screws that hold the lamp holder in place at the
back of the fixture.
3 Gently remove the lamp holder and guide it out of the housing. 4 Remove the old lamp from the socket. 5 Holding the new lamp by its ceramic base - do not touch the glass bulb -
insert it firmly and squarely into the lamp socket.
6 Clean the glass bulb with an alcohol wipe or a clean, lint-free cloth wetted
with alcohol. 7 Gently insert the lamp and screw the holder into place. 8 We recommend that you activate the Lamp Hour Warning function on the
Imager and that you set the expected number of hours of life the lamp has.
This is done using the Personality menu on the Imager (see the Imager user
manual). Remember to also reset the lamp hour counter using the
Information menu on the Imager. When the lamp hour counter reaches:
• 100 hours less than the expected life time of the lamp, the display on the Imager will start blinking LHr in the display. At this point you should change the lamp to avoid the risk of lamp explosion.
• The expected life of the lamp, the lamp shuts off and can not be turned on again before the counter in the Imager is reset, or the predefined lamp hour warning level has been redefined.

Cleaning

Wash the aluminum housing of the Imager with a soft brush or sponge and a mild, non-abrasive car washing detergent. Rinse.
Service 57
Page 58
Cleaning the air filter in the Imager luminaire
The air filters can be found on the spine of the Imager and should be replaced regularly. You can order extra filters from your Martin Dealer (part number 91611079).

Firmware updates

Firmware updates are released when features are added. The latest version is available from the Support Area of the Martin Professional web site at http://www.martin.dk.
The installed firmware version number is displayed in the control panel under the InF/Uer menu.
Requirements
Firmware is installed using one of the following hardware de vices, here after referred to as the “Uploader”:
• Martin MP-2 Uploader
• PC using any DMX interface that supports the Software Uploader program (for example a Martin LightJockey or DABS 1 interface)
The following are required in order to install software:
• The Imager update file, available for download from the User Support Area of the Martin web site (http://www.martin.com).
58 Service
Page 59
• The Software Uploader program, version 5.3 or later - supplied with the Martin MP-2, LightJockey, or available for download from the support pages for these products in the User Support Area of the Martin web site.
Important In DMX or SA-mode (Stand Alone mode) the data link must be
terminated. In IR-mode press the ID button for approximately 5 sec. then the
fixtures will go into DMX-mode and the fixtures can be uploaded. Remove the IR-Remote receiver and terminate the link. After fixture power off the fixtures will be in IR-mode again.
For guidance on preparing a LightJockey, MP-2 or Software Uploader refer to the user documentation and online help for these prod ucts. Follow these instructions before proceeding to the next section.
Updating fixture firmware with the MP-2 Uploader
1 Connect a prepared MP-2 Uploader to the DMX link on the Imager. Apply
power to the fixtures and the MP-2. Wait a few moments for the fixtures to reset.
2 Select Read Memory Card from the MP-2 main menu. 3 Use the buttons on the right to scroll through the card slots. Select the slot
that holds the desired version of the Imager firmware.
4 Select 5 Select
6 After a successful upload the fixtures reset with the new software. If an error
Update Software. Select Yes to confirm.
Update in DMX mode to start the upload. The MP-2 initializes all
connected Imagers.
occurs and the fixtures do not reset, data was interrupted or corrupted during transmission. Perform a boot mode upload as described in the following section.
Boot sector upload
If the normal upload procedure does not work, or if the software update notes call for a boot sector update. Boot sector update mode needs to be set either in the control menu, or by moving a jumper on the PCB in the Imager.
Performing a boot sector update by moving a PCB jumper
1 Make sure the Imager is isolated from AC power.
Service 59
Page 60
2 Open the cover behind the control panel using a 2 mm Allen wrench to
remove the 4 screws.
3 Referring to “Printed circuit board layout” on page 61, locate the jumper at
position PL12. Move the jumper to the “ENABLE” position (the two pins
closest to the fuses on the printed circuit board). 4 Perform a boot mode upload as described in the uploader manual. 5 When the upload is complete, disconnect the fixture from power and move
the jumper at PL12 back to the “DISABLE” position (the two pins fa rthest
away from the fuses on the printed circuit board). 6 Replace the cover and reapply power.
Performing a boot sector update via the control
menu
1 Select the Utility (UtL) menu from the control menu. 2 Select Upload (UPL) and then select yES to place the fixture in Boot Upload
Mode. 3 Perform a boot mode upload as described in the uploader manual. 4 When the upload is complete, use the control menu to disable Boot Upload
Mode.
60 Service
Page 61

Printed circuit board layout

The PCB can be found behind the control panel.
Printed circuit board layout 61
Page 62

Troubleshooting

Problem Probable cause(s) Remedy
No response from fixture when power is applied.
Fixture resets but does not respond correctly to controller (DMX mode operation).
Fixture does not reset correctly.
No light, lamp cuts out intermittently, or burns out too quickly.
No power to fixture. Check power and data
Primary fuse blown in Base.
Controller not connected. Connect controll er. Incorrect addressing of the
fixtures. Bad data link connection. Inspect cab les and correct
Data link not terminated. Insert termination plug in
Defective fixture or 2 devices transmitting on link.
Electronic or mechanical failure.
Lamp missing or blown. Disconnect fixture and
Fixture or lamp is too hot. Allow fixture to cool. If
Incorrect power supply setting.
cables. Replace fuse.
Check address setting on fixture and controller.
poor connections and/or broken cables.
output of last fixture. Bypass fixtures one at a
time until normal operation is regained: unplug both connectors and connect them directly together.
Contact service technician.
replace lamp.
problem persists, contact service technician.
Check setting.

Error messages

Message in display Error Remedy
EEE EPROM error Contact your Martin dealer for
rAE
62 Troubleshooting
Memory error Contact your Martin dealer for
service.
service.
Page 63
Message in display Error Remedy
FPE
FPGA error Contact your Martin dealer for
service.
drE
Driver error Contact your Martin dealer for
service.
LHE
Lamp hour expected
Replace the lamp. life has been reached and the lamp shuts off.
rtE
Real time clock error.
The battery on the mother board
needs to be replaced. Contact
your Martin dealer for service.
LE
Lamp error. After attempting to strike a lamp once and failing, the Imager will wait approximately 6 minutes (for the lamp to cool) and re­attempt to strike the lamp. If this fails the Lamp Error message will appear.
Replace the lamp if necessary
Check and replace fuses if
necessary
Check that the fan is functioning
and that there is enough space
around the air vent.
Issue a Lamp off command and
wait 6 minutes before attempting
to strike the lamp again
manually.
Contact your Martin dealer for
service.
LtE
Temperature error (lamp sensor)
The lamp cannot be struck
Check that there is enough
space around the air vent.
Check that the ambient
temperature does not exceed
40° C (104° F).
Contact your Martin dealer for
service.
gtE
Temperature error (gobo sensor)
The lamp cannot be struck
Check that there is enough
space around the air vent.
Check that the ambient
temperature does not exceed
40° C (104° F).
Contact your Martin dealer for
service.
FoE
Focus error Contact your Martin dealer for
service.
rgE
Gobo rotation error Contact your Martin dealer for
service.
goE
Gobo error Contact your Martin dealer for
service.
SHE
Lamp short error The lamp cannot be turned off.
Contact your Martin dealer.
Troubleshooting 63
Page 64
Message in display Error Remedy
LSE
Light sensor error The light sensor is not working.
Contact your Martin dealer for service.
LFE
Lamp fan error The lamp fan speed is too low or
too high. Contact your Martin dealer for service.
gFE
Gobo fan error The gobo fan speed is too low or
too high. Contact your Martin dealer for service.
Lhu Ltu
Lamp hour warning Replace the lamp if necessary Temperature
warning (lamp sensor). Temperature around the lamp is too high.
Check that there is enough space around the air vent.
Check that the ambient temperature does not exceed 40° C (104° F).
Contact your Martin dealer for service.
gtu
Temperature warning (gobo sensor) T emperature around the gobo is too high.
Check that there is enough space around the air vent.
Check that the ambient temperature does not exceed 40° C (104° F).
Contact your Martin dealer for service.
Hot
Hot lamp warning The lamp is too hot to be turned
on. Wait for the lamp to cool before attempting to re-strike it.
64 Troubleshooting
Page 65
S
ECTION
6. R
EFERENCE
Troubleshooting 65
Page 66

Control menu structure

Default settings appear in bold.
Level 1 Level 2 Level 3 Effect (default = bold)
Fixture address (Adr)
Profile (Pro) DMX-mode (d1) Set DMX mode (8-bit, tracking)
Stand alone (SA)
Adjust (AdJ) Reset (rSt) Reset effects to home position
DMX: 1-512 & IR: 0-9
DMX-mode (d2) Set DMX mode (16-bit, tracking)
IR-remote "send" (rCS)
IR-remote "recieve" (rCr)
Enable SA (run) Off (OFF) Disable stand alone operation
On (On) Enable stand alone operation
SA Execution (SAE)
Lamp on (LOn) Turn lamp on Lamp off (LOF) Turn lamp off Intensity (Int) Open (OPn) Intensity 100%
Focus (Foc) Reset focus
Gobo wheel (gob)
Single fixture (Sin)
Master (Snd) Fixture is set master for program
Synchronized (Syn)
Closed (CLO) Intensity 0%
(rF) Near (nEA) Far (FAr) Reset gobo
(rg) Gobo 1 (g 1) Gobo 4 (g 4)
Select control address for both DMX and IR profile
Set IR-remote control "send" mode
Set IR-remote control "recieve" mode
Fixture operates in isolation
operation Fixture is set to synchronized
program operation
66 Control menu structure
Page 67
Personality (PEr)
Rotating gobo (rgo)
Reset Gobo (rg)
Gobo 1 no rotation (g 1)
Gobo 1 slow (1rS)
Gobo 1 fast (1rF)
Gobo 2 no rotation (g 2)
Gobo 2 slow (2rS)
Gobo 2 fast (2rF)
Gobo 3 no rotation (g 3)
Gobo 3 slow (3rS)
Gobo 3 fast (3rF)
Gobo 4 no rotation (g 4)
Gobo 4 slow (4rS)
Gobo 4 fast (4rF)
Pan/tilt (P-t) Position 1 (P1)
Position 1 (P2) Position 1 (P3) Position 1 (P4) Position 1 (P5) Position 1 (P6) Position 1 (P7)
DMX lamp off
Off (OFF) Disable lamp off without confirmation
(LOF)
On (On) Enable lamp off without
confirmation
DMX reset (rES) Off (OFF) Disable reset without confirmation
On (On) Enable reset without confirmation
Control menu structure 67
Page 68
Personality (PEr) continued
Auto lamp on (ALO)
Display (dIS) Off (OFF) Turn display off 2 minutes after key
Store remote status (SrS)
MC-X lamp off (nnO)
Error messages (Err)
Lamp Fan Temp. regulation (tFL)
Gobo Fan Temp. regulation (tFg)
Lamp hour warning (LHr)
Off (OFF) Strike lamp from controller or
display
On (On) Automatically strike lamp within
90sec from power on.
press
On (On) Keep display lit Off (OFF) Disable the store remote status
feature.
On (On) Enable the store remote status
feature.
Off (OFF) Disable MC-X lamp off
On (On) Enable MC -X button 7 lamp off Off (OFF) Error warnings disabled
On (On) Error an warning messages enabled Off (OFF) Lamp fan Temperature fan regulation
disabled
On (On) Lamp Fan Temperature regulation
enabled
Off (OFF) Gobo Fan Temperature regulation
disabled
On (On) Gobo Fan Temperature regulation
enabled
Off (OFF) Lamp hour warning disabled
On (On) Enable power on warnin g and set
Swap pan/tilt (Pt) Off (OFF) Do not map pan to tilt and vice
On (On) Map pan to tilt and vice versa
Pan invert Off (OFF) Do not invert pan movement
On (On) Invert pan movement
Tilt invert Off (OFF) Do not invert tilt movement
On (On) Invert tilt movement
Restore default (FAC)
Yes (yES) Restore default personality settings No (no)
value [1.000h] If time exceeds +10% over the set value, it will not only give warning but also prevent lamp strike.
versa
Page 69
Info (InF) only display
not MP2
Reset counters (rEC)
(UEr) Read firmware version number (tLA) (CUr) Read current lamp temperature [×C]
Yes (yES) Reset all counters. No (no)
(tOt) Read maximum lamp temperature
since fabrication [×C]
(rES) Read maximum lamp temperature
since reset [×C]
(tgo) (CUr) Read current gobo temperature [×C]
(tOt) Read maximum gobo temperature
since fabrication [×C]
(rES) Read maximum gobo temperature
since reset [×C]
(Hr) (tOt) Read power-on hours since
fabrication
(rES) Read power-on hours since counter
was reset
(LHr) (tOt) Read lamp hours since fabrication
(rES) Read lamp hours since counter was
reset
(UAL) Read set value fo r warning
(LSt) (tOt) Read lamp strikes since fabrication
(rES) Read lamp strikes since counter was
reset
Utility (UtL) (UPL) Yes (yES) Set fixture to Boot Upload mode.
No (no)
Test (tSt) (Pcb) Yes (yES) Test PCB. For service use only
No (no)
Control menu structure 69
Page 70

DMX protocols

The DMX protocols each have two modes:
DMX mode 1 uses 9 channels and does not allow fine adjustment of movement and effects.
DMX mode 2, which is the default, uses 12 channels and allows fine adjustment of movement and effects.
The DMX mode that is used is spe cified using the Profile menu in the control panel (see “Control menu structure” on page 66.
Choose the protocol appropriate to the your Imager model:
• “Imager 04 DMX-Gobo Wheel” on page 71.
• “Imager 04 DMX-Gobo Wheel with moving-mirror fitted” on page 72.
• “Imager 01 DMX-Gobo” on page 74.
• “Imager 01 DMX-Gobo with moving-mirror fitted” on page 76.
Page 71

Imager 04 DMX-Gobo Wheel

DMX2 DMX 2 Value Percent Function
1
0 - 208 208 - 217 218 - 227 228 - 237 238 - 247 248 - 255
2
0 - 255 0 - 100
3
0 - 19 20 - 39 40 - 59 60 - 79 80 - 99
100 -119 120 - 139 140 - 159 160 - 198 199 - 237 238 - 255
4
0 - 255
0 - 81 81 - 85 85 - 87 89 - 93 93 - 97
97 - 100
0 - 7
7 - 15 15 - 23 23 - 31 31 - 39 39 - 46 47 - 54 55 - 62 63 - 78 78 - 93
93 - 100
0 - 100
Reset, Lamp On/Off
Reserved (no change) Reset fixture Reserved (no change) Lamp power on Reserved (no change) Lamp power off: T>= for 5 seconds. If reset or power off are disabled,
confirm on channel 3, by selecting image 4, either in indexed or continuous rotation, and focus in near position (channel 5 or 6).
Intensity
Intensity 0→100%
Image Selection
Image 1, indexed rotation Image 2, indexed rotation Image 3, indexed rotation Image 4, indexed rotation Image 1, continuous rotation Image 2, continuous rotation Image 3, continuous rotation Image 4, continuous rotation CW (Clockwise) wheel rot.,
slowfast CCW wheel rot. fastslow Reserved (no change)
Image Rotation (selec t indexed image rotation, on channel 3)
Coarse position index (MSB), MinMax
Start code = 0
3 - 127 128 - 252 253 - 255
5
0-255 0-100
56
0-255 0-100
0 - 2
Rotation Velocity (select cont. image rotation, on channel 3)
0
1 - 50
50 - 99
99 - 100
DMX protocols 71
No rotation CW rotation, slow→fast CCW rotation, fast→slow No rotation
Image Rotation, Fine Position
Fine position index (LSB), Min→Max
Focus
Infinitynear
Page 72
DMX2 DMX 2 Value Percent Function
6 7 0-255 0-100 Reserved (no change)
8 0-255 0-100 Reserved (no change)
7 9 0-255 0-100 Reserved (no change)
10 0-255 0-100 Reserved (no change) 8 11 0-255 0-100 Reserved (no change) 912
3 - 251
252 - 255
0 - 2
0
1 - 96
97 - 100
Image and Focus Speed
Tracking mode Fastslow Blackout while moving

Imager 04 DMX-Gobo Wheel with moving-mirror fitted

DMX 1 DMX 2 Value Percent Function
1
0 - 208 208 - 217 218 - 227 228 - 237 238 - 247 248 - 255
2
0 - 255 0 - 100
0 - 81 81 - 85 85 - 87 89 - 93 93 - 97
97 - 100
Reset, Lamp On/Off
Reserved (no change) Reset fixture Reserved (no change) Lamp power on Reserved (no change) Lamp power off: T >= for 5 seconds If reset or power off are disabled,
confirm on channel 3, by selecting image 4, either in indexed or continuous rotation, and focus in near position (channel 5 or 6).
Intensity
Intensity 0→100%
Start code = 0
Start code = 0
72 DMX protocols
Page 73
DMX 1 DMX 2 Value Percent Function
3
0 - 19 20 - 39 40 - 59 60 - 79 80 - 99
100 -119 120 - 139 140 - 159 160 - 198 199 - 237
0 - 7
7 - 15 15 - 23 23 - 31 31 - 39 39 - 46 47 - 54 55 - 62 63 - 78 78 - 93
Image Selection
Image 1, indexed rotation Image 2, indexed rotation Image 3, indexed rotation Image 4, indexed rotation Image 1, continuous rotation Image 2, continuous rotation Image 3, continuous rotation Image 4, continuous rotation CCW wheel rotation, slow→fast CW (Clockwise) wheel rot.,
fastslow
238 - 255
4
93 - 100
Reserved (no change)
Image Rotation (selec t indexed image rotation, on channel 3)
0 - 255
0 - 100
Coarse position index (MSB), MinMax
Rotation Velocity (select cont. image rotation, on channel 3)
0 - 2
3 - 127 128 - 252 253 - 255
5
0-255 0-100
56
0-255 0-100
67
0-255 0-100
8
0-255 0-100
79
0-255 0-100
10
0-255 0-100
811
0 - 2
3 - 251 252 - 255
912
0 - 2
3 - 251 252 - 255
0
1 - 50
50 - 99
99 - 100
0
1 - 98
99 - 100
0
1 - 96
97 - 100
No rotation CCW rotation, slow→fast CW rotation, fast→slow No rotation
Image Rotation, Fine Position
Fine position index (LSB), Min→Max
Focus
Infinitynear
Pan
Leftright (128 = neutral)
Pan fine (LSB)
Leftright
Tilt
Updown (128 = neutral)
Tilt fine (LSB)
Updown
Pan/Tilt Speed
Tracking mode Fastslow Blackout while moving
Image and Focus Speed
Tracking mode Fastslow Blackout while moving
Start code = 0
DMX protocols 73
Page 74

Imager 01 DMX-Gobo

DMX2 DMX 2 Value Percent Function
1
0 - 208
208 - 217 218 - 227 228 - 237 238 - 247 248 - 255
2
0 - 255 0 - 100
3
0 - 79
80 - 159
160 - 255
4
0 - 255
0 - 81 81 - 85 85 - 87 89 - 93 93 - 97
97 - 100
0 - 31 31 - 62
63 - 100
0 - 100
Reset, Lamp On/Off
Reserved (no change) Reset fixture Reserved (no change) Lamp power on Reserved (no change) Lamp power off: T>= for 5 seconds. If reset or power off are disabled,
confirm by setting DMX-channel 3 to any value in the ranges 60-79 or 140­159, and focus in near position. (channel 5 or 6).
Intensity
Intensity 0→100%
Image Selection
Image, indexed rotation Image, continuous rotation Reserved (no change)
Image Rotation (select indexed image rotation, on channel 3)
Coarse position index (MSB), MinMax
Start code = 0
Rotation Velocity (select cont. image rotation, on channel 3)
0 - 2
3 - 127 128 - 252 253 - 255
5
0-255 0-100
56
0-255 0-100
6 7 0-255 0-100 Reserved (no change)
8 0-255 0-100 Reserved (no change)
7 9 0-255 0-100 Reserved (no change)
10 0-255 0-100 Reserved (no change)
8 11 0-255 0-100 Reserved (no change)
74 DMX protocols
0
1 - 50
50 - 99
99 - 100
No rotation CW rotation, slow→fast CCW rotation, fastslow No rotation
Image Rotation, Fine Position
Fine position index (LSB), Min→Max
Focus
Infinitynear
Page 75
DMX2 DMX 2 Value Percent Function
912
3 - 251
252 - 255
0 - 2
0
1 - 96
97 - 100
Image and Focus Speed
Tracking mode Fastslow Blackout while moving
Start code = 0
DMX protocols 75
Page 76
Imager 01 DMX-Gobo with moving­mirror fitted
DMX 1DMX 2Value PercentFunction
1
0 - 208 208 - 217 218 - 227 228 - 237 238 - 247 248 - 255
2
0 - 255 0 - 100
3
0 - 79
80 - 159
160 - 255
4
0 - 255
0 - 81 81 - 85 85 - 87 89 - 93 93 - 97
97 - 100
0 - 31 31 - 62
63 - 100
0 - 100
Reset, Lamp On/Off
Reserved (no change) Reset fixture Reserved (no change) Lamp power on Reserved (no change) Lamp power off: T >= for 5 seconds If reset or power off are disabled,
confirm by setting DMX-channel 3 to any value in the ranges 60-79 or 140­159, and focus in near position. (channel 5 or 6).
Intensity
Intensity 0→100%
Image Selection
Image, indexed rotation Image, continuous rotation Reserved (no change)
Image Rotation (select indexed image rotation, on channel 3)
Coarse position index (MSB), MinMax
Start code = 0
Rotation Velocity (select cont. image rotation, on channel 3)
0 - 2
3 - 127 128 - 252 253 - 255
5
0-255 0-100
56
0-255 0-100
67
0-255 0-100
8
0-255 0-100
79
0-255 0-100
76 DMX protocols
0
1 - 50
50 - 99
99 - 100
No rotation CCW rotation, slowfast CW rotation, fast→slow No rotation
Image Rotation, Fine Position
Fine position index (LSB), Min→Max
Focus
Infinitynear
Pan
Leftright (128 = neutral)
Pan fine (LSB)
Leftright
Tilt
Updown (128 = neutral)
Page 77
DMX 1 DMX 2 Value Percent Function
10
0-255 0-100
811
3 - 251
252 - 255
912
3 - 251
252 - 255
0 - 2
0 - 2
0
1 - 98
99 - 100
0
1 - 96
97 - 100
Tilt fine (LSB)
Updown
Pan/Tilt Speed
Tracking mode Fastslow Blackout while moving
Image and Focus Speed
Tracking mode Fastslow Blackout while moving
Start code = 0
DMX protocols 77
Page 78

Specifications - Imager

Physical
Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726 mm (28.6 in.)
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 mm (9.5 in.)
Weight (Imager 04 DMX Gobo Wheel). . . . . . . . . . . . . . . . . . . . . . 9.9 kg (21.8 lbs)
Weight (Imager 01 DMX Gobo) . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.7 kg (21.4 lbs)
Installation
Mounting device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Imager J-Box
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ceiling mount
Minimum distance to combustible materials . . . . . . . . . . . . . . . . . . . . . . .1 m (39 in)
Minimum distance to illuminated surfaces . . . . . . . . . . . . . . . . . . . . . . 0.5 m (20 in)
Construction
Imager housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum and plastic
Thermal
Maximum ambient temperature (Ta) . . . . . . . . . . . . . . . . . . . . . . . . . . 40° C (104° F)
Maximum surface temperature, steady state, Ta=40° C. . . . . . . . . . . 100° C (212° F)
Source
Lamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 W discharge
Approved models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Philips MSD 250
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Philips MSD 250/2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Osram HSD 250/78
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Osram HSD 250/60
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Osram HSD 250/80
Power supply
Power source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Imager Base via Imager J-Box
PCB fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.15 AT, 2 AT
Dynamic effects
Dimmer Gobo rotation, continuos or to indexed position Pan and tilt (with optional moving-mirror) Focus
78 Specifications - Imager
Page 79
Gobos
Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D
Outside diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53.3 mm (2.10 in.)
Maximum image diameter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 mm (1.57 in.)
Maximum thickness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 mm
Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . metal or glass
Photometrics
Standard beam angle . . . . . . . . . . . . . . . . . . . . . 23°, focal length = 100 mm (3.9 in.)
Optional bean angle. . . . . . . . . . . . . . . . . . 15° lens, focal length = 150 mm (5.9 in.)
Optional bean angle. . . . . . . . . . . . . . . . . . 32° lens, focal length = 70 mm (2.75 in.)
Size of a projected image using a gobo of a given size:
projected image size
Gobo image size required to achieve a projected image size:
gobo image size
gobo image size projected distance×
----------------------------------------------------------------------------------------=
projected size focal length×
------------------------------------------------------------------- -=
focal length
projected distance
Control & Programming
Control options . . . . . . . . . . . . . . . . DMX-512, stand-alone, synchronous operation
Receiver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-485
Setting and addressing. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-digit LCD control panel
Firmware update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Serial upload (.MU3)
Data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RJ-45
Data output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RJ-45
DMX channels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 or 12
Ordering information
Imager, Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90721000
Imager 04 DMX Gobo Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90540000
Imager 01 DMX Gobo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90540100
Moving-mirror for Imager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 91611069
Included items
User manual Osram HSD 250/80 Beacon gobo (installed) RJ-45 terminator (installed in J-Box) J-Box 4 rubber cable-glands for J-Box
Specifications - Imager 79
Page 80
Accessories
Martin infrared remote control transmitter. . . . . . . . . . . . . . . . . . . . . . P/N 90760010
Martin infrared remote control receiver . . . . . . . . . . . . . . . . . . . . . . . . P/N 91611047
MP-2 uploader:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90758420
MC-X Controller, 220-245V/50Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90718200
MC-X Controller, 110-120V/60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90718300
15 degree lens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 91611074
32 degree lens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 91611075
Slide projection kit (with heat filter) . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 91611076
Remote control upgrade kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 91614008
Air filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 91611079
Color filter - Lilac 503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402000
Color filter - Light Blue 102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402001
Color filter - Green 208 IAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402002
Color filter - Green 204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402003
Color filter - Orange 306M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402004
Color filter - Red 308 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402005
Color filter - Green 203 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402006
Color filter - Blue 108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402007
Color filter - UV-transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402008
Color filter - Half Minus Green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 46402009
Heat filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 41102060
The number next to some color filters are OCLI (Optical Coating Laboratory, Inc.) reference numbers.
80 Specifications - Imager
Page 81
Specifications - Imager 81
Page 82
Page 83
Page 84
www.martin-architectural.com Olof Palmes Allé 18 8200 Aarhus N Denmark
Tel: +45 8740 0000
Fax +45 8740 0010
Loading...