The following symbols are used to identify important safety information on the product
and in this manual:
installing, operating or servicing this product.
Warning! Safety hazard.
Risk of severe injury or
death.
Warning! See user manual
for important safety
information.
Warning! Hazardous
voltage. Risk of lethal or
severe electric shock.
Warning! Fire hazard.
Warning! Risk Group 3 product according to EN 62471. Do not look directly into
the beam. Do not view the light output with optical instruments or any device that
may concentrate the beam.
This lighting fixture is for professional use only and must be installed by a qualified
technician. It is not for household use. It presents risks of severe injury or death
due to fire hazards, electric shock and falls. It produces a powerful, concentrated
beam of light that can create a fire hazard or a risk of eye injury if the safety
precautions below are not followed.
Warning! Hot surface. Risk
of burns.
Warning! Risk of eye
injury. Wear protective
eyewear.
Warning! Do not look into
light output.
Respect all locally applicable laws, codes and regulations when installing,
operating or servicing the fixture.
Install, operate and service Martin™ products only as directed in their user
manuals or you may create a safety hazard or cause damage that is not covered
by product warranties.
Keep this user manual for future use. Before installing, using or servicing this
fixture, check that you have the latest version of the user manual, available on the
fixture’s Tech Docs/Support page on the Martin™ website at
http://www.martin.com. Martin™ user manual versions are identified by the
Revision letter given at the bottom of page 2.
Refer any operation not described in this user manual to Martin™ Global Service
or an authorized Martin™ service agent.
4 Exterior Projection 500 User Manual
Page 5
Follow the safety precautions listed below and observe all warnings in this manual
and printed on the fixture.
If you have any questions about how to install, operate or service the fixture
safely, please contact your Martin™ distributor (see www.martin.com/distributors
for details) or call the Martin™ 24-hour service hotline on +45 8740 0000, or in the
USA on 1-888-tech-180.
Protection from electric shock
This fixture is IP66 rated. Suitable for wet locations. Do not immerse in water.
Disconnect the fixture from AC power before carrying out any installation or
maintenance work and when the fixture is not in use.
Ensure that the fixture is electrically connected to ground (earth).
Use only a source of AC power that complies with local building and electrical
codes and has both overload and ground-fault (earth-fault) protection.
The circuit used to supply the fixture with AC power must include a power switch
that is easily accessible so that the fixture can easily be disconnected from power.
Isolate the fixture from power immediately if any seal, cover, cable, connector or
other component is damaged, defective, deformed, wet or showing signs of
overheating. Contact Martin™ for any service operation not described in this user
manual. Do not reapply power until repairs have been completed
Before using the fixture, check that all power distribution equipment and cables
are in perfect condition and rated for the electrical requirements of all connected
devices.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (Ta) exceeds 45° C (113° F).
The surface of the fixture casing can reach up to 85° C (185° F) during operation.
Avoid contact by persons and materials. Allow the fixture to cool for at least 10
minutes before handling.
Keep flammable materials well away from the fixture. Keep combustible materials
(e.g. fabric, wood, paper) at least 0.1 m (4 ins.) away from the fixture housing.
Ensure that there is free and unobstructed airflow around the fixture.
Do not illuminate surfaces within 0.5 m (1.6 ft.) of the front glass.
Do not stick filters, masks or other materials onto any optical component.
The fixture’s optical components can focus the sun’s rays, creating a risk of fire
and damage. Do not expose the front of the fixture to sunlight or any other intense
light source.
Protection from eye injury
Do not stare directly into the light output. Ensure that persons are not looking
directly into the lamp when the fixture lights up suddenly. This can happen when
power is applied, when the fixture receives a DMX signal, or when certain control
menu items are selected.
Do not look at the light output with magnifiers, telescopes, binoculars or similar
Exterior Projection 500 User Manual 5
optical instruments that may concentrate the light output.
Wear protective glasses and other PPE (personal protective equipment) when
working on or near the fixture.
Page 6
The risk group distances given below apply to the light output from one fixture
only. If fixtures can be operated in combination, light intensity can increase and
you should consult a lighting professional for safety recommendations.
The Exterior Projection 500 falls into the following risk groups according to EN
62471 at the distances indicated:
At a distance of less than 5.2m (17 ft.) from the fixture, the light output can
potentially cause eye or skin injury before an exposed person’s natural aversion
responses (blink reflex and reaction to skin discomfort) can protect them. At
distances greater than 5.2m (17 ft.), potential eye and skin injury hazards from the
light output are normally prevented by natural aversion reflexes.
Position the Exterior Projection 500 so that persons cannot be exposed to the
fixture’s light output at less than 5.2m (17 ft.) from the fixture and so that
prolonged staring into the light output at less than 7 m (23 ft.) from the fixture is
not expected.
Protection from injury
Fasten the fixture securely to a fixed surface or structure when in use. The fixture
is not portable when installed.
Ensure that any supporting structure and/or hardware used can hold at least 10
times the weight of all the devices they support.
Check that all external covers and installation hardware are securely fastened.
Do not operate the fixture with missing or damaged covers, shields or any optical
component.
Block access below the work area and work from a stable platform whenever
installing, servicing or moving the fixture.
In the event of an operating problem, stop using the fixture immediately and
disconnect it from power. Do not attempt to use a fixture that is obviously
damaged.
Do not modify the fixture or install other than genuine Martin™ parts.
6 Exterior Projection 500 User Manual
Page 7
Introduction
The Exterior Projection 500 from Martin™ is an image projection fixture that features a powerful
230 W LED engine, advanced dynamic effects and rugged weatherproofing.
Four models are available with beam angles ranging from narrow to very wide. Exterior Projection
500 Narrow, Medium and Wide models are suitable for the projection of images and/or text such
as logos. The Exterior Projection 500 Very Wide has less clearly defined projections than the other
three models and is best suited to the projection of abstract patterns. See www.martin.com for
photometric data relating to the different beam angle options. Fixtures can be converted from one
beam angle to another with the help of kits available from Martin, but beam angle kits must be
installed by Martin™ or its authorized service agents only.
The fixture features a rotating gobo wheel with six interchangeable rotating gobos and a gobo
animation effect that provides animated projections when used in combination with a rotating
gobo. The fixture has 8 dichroic color filters, one radial 3-facet and one linear 4-facet rotating prism
and a frost filter. It also has smooth electronic dimming, remote focusing and strobe effects.
The Exterior Projection 500 can be controlled using any controller that is compatible with the
industry-standard DMX512 lighting control protocol. It will also respond to RDM (Remote Device
Management) communication if you use an RDM-compliant controller. RDM lets you set up and
retrieve status information from fixtures over the DMX data link. Martin™ can provide suitable
high-quality DMX and DMX/RDM controllers with an intuitive user interface that make it easy to set
up impressive lighting effects. See www.martin.com for details.
The Exterior Projection 500 can also function without DMX control as a standalone projector and
display one of twenty dynamic lighting effects that you can pre-program.
Before using the product for the first time
1. Unpack and ensure that there is no transportation damage before using the fixture. Do not
attempt to operate a damaged fixture.
2. Check the fixture’s Tech Docs / Product Support page on the Martin Professional™ website at
www.martin.com and make sure that you have read the latest user documentation and
technical information about the fixture. Martin™ user manual revisions are identified by the
revision letter at the bottom of the inside cover.
3. Read ‘Safety information’ on page 4 of this user manual.
4. Ensure that the voltage and frequency of the power supply
match the power requirements of the fixture.
5. See illustration on right. Remove the cover (arrowed) from
the control panel and display on the side of the fixture so
that you can set up the fixture using the control panel.
6. If the temperature is below -20° C (-4° F), apply power to
the fixture but do not use it for 30 minutes. This will give
the fixture time to warm up to within its operating
temperature range.
Note that whenever AC power is applied to the fixture, it will reset all effects and functions to their
home positions. Reset is available when fixture temperature is above -20° C (-4° F).
Exterior Projection 500 User Manual 7
Page 8
Fixture overview
1. Control panel display (shown with cover removed)
2. Control buttons:
Enter the control menus, or
MENU
DOWN (▼)
UP (▲) Scroll up a menu or scroll ascending values
ENTER Confirm a selection
3. Adjustable mounting yoke
4. AC mains power cable
5. DMX data combined in/out cable
6. Pressure relief valve
Return to the previous level of the menu structure, or
Press and hold to exit the control menus
Scroll down a menu or scroll descending values
8 Exterior Projection 500 User Manual
Page 9
Physical installation
Warning! Read ‘Safety information’ on page 4 before installing the fixture.
Protection from the sun
Important! The fixture’s optical system can
focus rays from the sun inside the fixture,
causing internal damage and presenting a fire
hazard. Make sure that the sun will not shine
into the front of the fixture at any time.
The Glare Shield available from Martin™ (see
‘Accessories’ on page 43) can help protect
the front of the fixture from the sun.
If the control panel will be exposed to sunlight, install its cover to protect the panel and its display
from heat and UV radiation.
Protection from moisture
If there is a break or cut at any point in a cable (for example at a connection point), and if this is
exposed to water, moisture can be drawn up the inside of the cable due to the vacuum effect of
temperature fluctuations during operation. Ensure that the
fixture is protected from the entry of water via cables by
using IP66-rated connectors or junction boxes, or by
protecting connectors with weatherproof housings. Make
sure that all cables open into dry areas.
See illustration on right. Create a drip loop before cable
glands to reduce any tendency for glands to be constantly
immersed in water.
Mounting the fixture
The fixture can be mounted at any angle and the yoke can be fastened to a vertical, horizontal or
angled surface, but the sides of the fixture must be vertical when installed (see examples below),
or the fixture’s cooling airflow will be affected, leading to excessively high fixture temperature and
reduced light output.
Sides of fixture Sides of fixture not
vertical: OK vertical: Not OK
Exterior Projection 500 User Manual 9
Page 10
200
Ø53
82
Ø13
9
60
90°
Do not stand the fixture freely on a surface or leave it where it can be moved or fall over. Ensure
that the installation surface or structure and all fasteners used can safely bear at least 10 times the
weight of all the fixtures and equipment they will support.
Avoiding galvanic corrosion
The fixture and mounting bracket are manufactured in corrosion-resistant anodized aluminum.
Avoid mounting the fixture in direct contact with other types of metal, as this can cause galvanic
corrosion. When fastening to a metal that is not aluminum:
•Use an electrically insulating material (such as rubber or plastic) or coating between the
mounting bracket and the other metal.
•Use a non-conductive coating such as Delta Seal on fasteners (screws, bolts, washers,
etc.) where they come into contact with the mounting bracket.
Fasteners
The type of fasteners used will depend on the installation, but use a minimum of three highstrength corrosion-resistant fasteners that are suitable for the installation environment and
application. We recommend that all fasteners are stainless steel A4-70 grade according to ISO
3506 or steel grade 8.8 according to ISO 898-1 or better.
Install washers between the head of each fastener and the yoke base. If you use nuts, use selflocking type only and install washers under the nuts.
Anchoring to a surface or structure
The fixture’s mounting yoke base must be securely anchored to a flat surface on a wall, pedestal,
structural beam or other suitable support. The yoke allows the fixture to be manually panned and
tilted for beam aiming adjustment.
To anchor the fixture to a surface:
1. See illustration below. Fasten a 12 mm (1/2 inch) shaft diameter bolt to the surface through the
center hole A in the mounting yoke.
2. Fasten two bolts with 8 mm (5/16 inch) shaft diameter to the surface with one bolt passing
through each of the curved slots C to anchor the fixture. This will give approximately 90° of
pan adjustment.
3. Adjust the fixture’s pan angle (side-to-side beam aiming) as described later in this chapter.
Adjusting pan is best carried out with power applied to the fixture so that the projection is
visible. Once pan is correct, fasten two 12 mm (1/2 inch) shaft diameter bolts to the surface
with one bolt passing through each of the holes B. Once bolts have been installed in holes B,
pan adjustment is no longer possible.
CC
BB
A
Mounting yoke base
10 Exterior Projection 500 User Manual
Page 11
Secondary attachment
If a secondary attachment is required for reasons of safety (in
entertainment venues, onboard marine vessels or in temporary
installations, for example), see drawing on right. Loop a safety
cable that is approved for the weight of the fixture through the
secondary attachment point (arrowed) in the fixture and attach
the safety cable to a secure anchoring point so that the cable
will catch the fixture if the primary method of attachment fails.
Adjusting aiming (pan and tilt)
Warning! The fixture can become hot. Wear heat-resistant gloves if you adjust
the aim of the fixture when it is (or has recently been) powered on.
Fixture aim adjustment is best carried out after the fixture has been
connected to power and in weak light conditions so that the
projection from the fixture is clearly visible.
See illustration on right. If you require very precise aiming and setup,
we recommend that you order the projection setup gobo available
from Martin™ for the Exterior Projection 500 (see ’Accessories’ on
page 43) and install it in the gobo wheel while you adjust fixture aim,
focus, etc.
To adjust the aim of the fixture:
1. Set the fixture to project a setup gobo (see above) or another gobo with a sharply defined
pattern. You can select the image remotely either via DMX or by using the MANUAL TEST
menu in the fixture’s control panel (see ‘Manual test’ on page 18).
2. Put on heat-resistant gloves.
3. See ‘Anchoring to a surface or structure’ on page
10. Loosen the bolts in the center hole A and
curved slots C slightly, just until you can rotate the
yoke.
4. See illustration on right. Loosen the tilt lock Allen
(hex) screws (arrowed) on both sides of the yoke
slightly, just until you can tilt the fixture in the
yoke.
5. Pan and tilt the fixture until it is aimed correctly.
6. Use a torque driver and tighten the four tilt adjustment screws to a torque of 1.8 – 2.3 Nm.
7. See ‘Anchoring to a surface or structure’ on page 10. Tighten the bolts in the center hole A and
curved slots C and install bolts in holes B. Check that the fixture will be held securely in all
wind and weather conditions.
Exterior Projection 500 User Manual 11
Page 12
AC power
Warning! Read “Safety Information” on page 4 before installing the fixture.
Electrical installation must be carried out by qualified professionals only.
Lock out power to the entire installation before working on cables and connections.
For protection from dangerous electric shock, the fixture must be grounded (earthed).
The AC power distribution system must be fitted with current overload and ground-fault
(earth-fault) circuit breakers as well as a means to isolate fixtures from power and lock
out power during service.
The Exterior Projection 500 is supplied in EU and US models. Both models accept AC power at
100-240 V nominal or 277 V nominal at 50 or 60 Hz. Do not connect to power at any other voltage
or frequency.
You can connect the Exterior Projection 500 to either of the following mains power distribution
systems:
Do not try to connect to a three-phase three-wire (three phases, ground/earth) system.
There is no power on/off switch. Power is applied to an Exterior Projection 500 fixture as soon as it
is connected to power. Provide a means to disconnect or shut down power to fixtures that is easily
accessible and is located close to the fixtures.
Do not use an external dimming system to supply power to the fixture, as this may cause damage
to the fixture that is not covered by the product warranty.
Connecting to AC mains power
The fixture is supplied with a power cable installed ready for connection. See illustration below:
AC power cable
To connect to a single-phase system or to one phase of a three-phase four-wire system:
1. Lock out power to the installation.
2. Connect the conductors in the power cable to the distribution circuit as follows:
a) Connect the green wire (US models) or yellow/green wire (EU models) to ground (earth).
b) Connect the white wire (US models) or blue wire (EU models) to neutral.
c) Connect the black wire (US models) or brown wire (EU models) to live (one phase of a
three-phase system).
3. Check that all installation work is completed and carry out appropriate tests and safety checks
before applying power.
12 Exterior Projection 500 User Manual
Page 13
It is possible to install a power plug on the power cable for temporary use only. If you need to do
this, install a grounding type (earthed) plug with integral cable grip that is rated minimum 277 V,
6 A. Follow the plug manufacturer’s instructions and connect the wires in the power cable as
shown in the table below:
US system
EU system
Live or L Neutral or N
Earth, Ground or
Black White Green
Brown Blue Yellow/green
Power plug connections
Exterior Projection 500 User Manual 13
Page 14
Control data link
A DMX512 data link is required in order to control the fixture via DMX (and manage fixtures via
RDM, if used). Your Martin™ supplier will be happy to help if you need advice or assistance in
planning the link.
Follow these guidelines when creating a DMX data link:
•Use RS-485 data cable designed for exterior use. RS-485 cable has low capacitance and
a characteristic impedance of 85 to 150 Ohms. It is electrically shielded and has at least
one twisted pair of conductors. The minimum recommended wire size is 0.25 mm2 (24
AWG) for runs up to 300 meters (1000 ft.) and 0.32 mm2 (22 AWG) for runs up 500 meters
(1640 ft.). A cable run of more than 500 meters requires the use of a splitter-amplifier to
boost the DMX signal.
•If independent control of a fixture is required, that fixture must have its own DMX
channels. Any fixtures that will always be required to behave identically can have the
same DMX address, which means that they will use the same DMX channels.
•512 DMX channels are available in a single DMX universe. Each time the number of DMX
channels required by the fixtures on a data link reaches 512 and you want to add more
fixtures, create a new DMX universe on a new data link and connect the additional fixtures
to the new link.
•You can connect up to 32 fixtures in a single daisy chain on a DMX data link. Connecting
in a daisy chain means that you must connect the DMX data OUT from one fixture to the
DMX data IN of the next fixture, creating a single line of fixtures. Do not split the link into
branches by creating a Y shape in the cable or at connectors.
•However, you can split a DMX data link into two or more branches if you use an optically
isolated DMX splitter-amplifier. To preserve RDM functionality, use an RDM-compatible
splitter such as the Martin™ RDM 5.5 Splitter. Each branch can contain up to 32 fixtures.
•If you reach the limit of 32 fixtures on a DMX data link, you can connect up to 32 additional
fixtures if you add a splitter-amplifier such as the Martin™ RDM 5.5 Splitter to the link in
order to boost the data signal. Adding a splitter-amplifier also lets you extend a data link
beyond 500 meters (1640 ft.).
•The data link (and each branch of the link if you have created branches with a splitter-
amplifier) must be terminated at the end by placing a 120 ohm resistor (available from
Martin, P/N 04150308) across the data output hot (+) and data output cold (-) conductors
of the last fixture on the link.
•Do not create long parallel runs of AC power and data cables, as these may cause
interference on the data link. Even if not required by law, use separate conduits for power
and data cables.
•The Exterior Projection 500’s combined data input/output cable does not support the
optional second data wire pair that is provided for in the DMX512-A standard. Do not place
devices that use the second data pair on the same DMX data link as Exterior Projection
500 fixtures.
Connecting the data link
Important! All connections must be completely protected from moisture (inside IP66-rated junction
boxes, for example).
Important! Connect the data output from one fixture to the data input of one fixture only. If you
connect one data output to more than one data input, you will split the DMX data link into branches
which will probably cause data signal integrity problems.
14 Exterior Projection 500 User Manual
Page 15
The Exterior Projection 500 is supplied with a hard-wired 1.8 m (5.9 ft.) shielded cable with 2 pairs
of wires for connection to a DMX data link.
The pair of wires with a green sleeve is for data input from the control device or previous device in
the daisy chain. The pair of wires with a brown sleeve is for data output (throughput) to the next
device in the daisy chain.
Exterior 500 Projection DMX data cable
Connect the cable as shown in the table below. Do not connect the shield conductor to ground
(earth) or allow it to come into contact with a connector shell, as this may cause interference.
Input wires
(green sleeve)
Output wires
(brown sleeve) Shield
Wire color white green white brown black
Signal DMX in + DMX in – DMX out + DMX out – common
Male XLR
pinout
Female XLR
pinout
pin 3 pin 2 - - pin 1
- - pin 3 pin 2 pin 1
Data connection pinout
Exterior Projection 500 User Manual 15
Page 16
Fixture setup
Warning! Read ‘Safety information’ on page 4 before operating the fixture.
Using the control menus
This section explains the fixture settings and utilities that are available using the control panel and
display that are located on the side of the fixture.
You can find a full map of the control menus in ’Control menus’ on page 38. Some settings and
functions are also available via RDM.
Control menu settings are retained when the fixture is powered off.
Navigating in the control menus
To access the control menus, press the MENU button and hold for three seconds.
• To select a menu option or to confirm a selection, press the ENTER button.
• To scroll up and down the items in a menu or adjust values, use the DOWN ARROW (▼)
and UP ARROW (▲) buttons.
• To return to a higher level in the menu structure, press the MENU button.
• To exit all active control menus and return directly to the top level, press and hold the
MENU button.
Passwords
The Exterior Projection 500 onboard control panel is password-protected to discourage tampering.
There are two passwords:
•A user password that is set to 111 by default, but can be changed to any number from 0 to
999. This password is required to enter the control menus.
•A service password that is factory-set to 123 and cannot be changed. This password is
required to reset the ’Lamp Hours’ counter, set the fixture to Evaporation Mode before
closing the top cover, and enter the fixture offset menus. Note that users may only make
changes to the fixture offsets with guidance from Martin Service.
To enter or set a password, use the DOWN ARROW and UP ARROW buttons to scroll to the
required number. When the number is displayed, press ENTER to confirm.
Setting a DMX address
The Exterior Projection 500 uses thirteen DMX channels to receive instructions from a DMX
controller. The fixture’s DMX address, also known as the start channel, is the first of these
channels. If a fixture that requires 4 DMX channels has its DMX address set to 1, for example,
then it uses channels 1, 2, 3 and 4. The next fixture can have its DMX address set to 5, the next to
9 and so on until all the 512 channels in one DMX universe are allocated.
If you want independent control of a group of fixtures, give each fixture its own DMX address so
that each fixture has its own control channels. If you want a group of fixtures of the same type to
always behave identically, give all the fixtures the same DMX address so that they all use the
same DMX control channels.
You can set a fixture’s DMX address using the fixture’s control panel or by sending commands
from an RDM-compliant DMX controller.
To set the fixture’s DMX address from the control panel:
1. Press and hold the MENU button to access the control menu.
16 Exterior Projection 500 User Manual
Page 17
2. Use UP and DOWN to select DMX ADDRESS from the menu. Press ENTER.
3. The fixture’s current DMX address is displayed. Press UP or DOWN to scroll to the DMX
address that you want to give to the fixture.
4. Press ENTER to store the DMX address in the fixture.
5. Press MENU to exit.
Programming a standalone show
You can program a standalone show – a sequence of ’scenes’ that run in a loop – in the Exterior
Projection 500. A scene consists of a combination of effects such as gobo selection, gobo
movement, color, intensity, etc. You can set the standalone show to run if you are not using a
DMX controller or if a signal from a DMX controller is lost. The show can have up to 20 scenes that
display for up to 10 minutes each. You can program ’fades’ (changes from one scene to the next)
so that scenes change immediately or change gradually over a period of up to 120 seconds’
duration.
Note: To enable standalone operation, the OFFLINE MODE setting in the FIXTURE CONFIG
menu must be set to RUN SHOW. See ’Offline mode – behavior without DMX’ on page 20. A
fixture will only run a standalone show when it is not receiving a DMX signal.
To program a stand-alone show:
1. Access the control menu and use UP and DOWN to scroll to PROGRAM SHOW. Press
ENTER to select.
2. Set the total number of scenes:
a) Select SET SCENE TOTAL and press ENTER.
b) Use UP and DOWN to select from 1 to 20 scenes.
c) Press ENTER.
3. Modify the appearance of scenes:
a) Select EDIT SCENE and press ENTER.
b) Select the scene that you want to modify and press ENTER.
c) Select the effect that you want to adjust (STROBE, INTENSITY, COLOR, etc.) and press
ENTER.
d) Press UP or DOWN to scroll to a value. When satisfied, press ENTER to confirm your
selection.
e) Repeat steps c) and d) for each effect.
f) Press MENU to go back up one level in the menus and select another scene to modify.
g) When done editing scenes, press MENU again to return to the PROGRAM SHOW menu.
4. Set the length of time each scene is displayed before fading to the next scene and set the
length of time one scene fades to the next scene:
a) Select SET SHOW TIMES and press ENTER.
b) Select SET HOLD TIME and press ENTER. Press UP or DOWN to scroll to scene
duration from 0 to 99.9 seconds. Press ENTER to confirm your selection.
c) Select SET FADE TIME and press ENTER. Press UP or DOWN to scroll to a scene
change fade duration from 0 to 99.9 seconds. Press ENTER to confirm your selection.
5. Press MENU to exit.
Manual control mode
The fixture can be tested, reset and returned to default factory settings manually from the control
panel. To enter manual mode:
1. Access the control menu and select MANUAL MODE.
2. Press ENTER.
Exterior Projection 500 User Manual 17
Page 18
Manual test / manual single scene display
The manual test commands let you display a single scene (i.e. a single combination of effects)
manually, either for test purposes or to control the fixture without a DMX controller. To set up the
scene:
1. Select MANUAL TEST and press ENTER.
2. Use UP and DOWN to scroll through the fixture’s effect controls (STROBE, INTENSITY,
COLOR, GOBO SELECTION, etc.). Press ENTER to select an effect to adjust.
3. Use UP and DOWN to select a value for the effect, and press ENTER to confirm your
selection.
4. Repeat for each effect you want to control.
5. Press MENU to exit.
Any scene that you set in the MANUAL TEST menu is retained in memory when fixture power is
cycled off and on. The MANUAL TEST menu therefore lets you set up a permanent single-scene
display without DMX control.
Resetting effects
To reset an effect, returning it to its default setting:
1. Select RESET FUNCTIONS and press ENTER.
2. Select ALL or one of the effects.
3. Press ENTER to reset.
4. Press MENU to exit.
Returning to factory defaults
To return the fixture to its factory default settings, erasing any settings, standalone scenes, etc.
stored in the fixture’s memory:
1. Select FACTORY DEFAULT and press ENTER.
2. Select YES to return to factory defaults or NO to exit.
3. Press ENTER to confirm.
4. Give the fixture time to return to the factory default settings.
Display setting
The DISPLAY SETTING menu provides options to invert, dim, and turn off the control panel
display.
Display inverse
For easier reading when the fixture is mounted upside down, flip the display as follows:
1. Select DISPLAY INVERSE and press ENTER.
2. Select YES to invert the display or NO for normal reading.
3. Press ENTER to confirm.
Display auto turn off
The display can be set to stay on or to turn off 1 minute after the last key press. To set display
behavior:
1. Select DISPLAY AUTO OFF and press ENTER.
18 Exterior Projection 500 User Manual
Page 19
2. Select NO to keep the display illuminated, or YES to have the display turn off automatically
after 1 minute.
3. Press ENTER to confirm.
Display intensity
To adjust the brightness of the control panel display:
1. Select INTENSITY and press ENTER.
2. Scroll to a value from 0 to 100%.
3. Press ENTER to confirm.
Fixture status
You can view the following fixture status information in the FIXTURE STATUS menu:
• Current temperature of LED engine.
• Total number of hours the fixture has been in use.
• Total number of hours the LEDs have been powered on.
• Software version currently installed in the fixture.
You can also call up fixture status information from an RDM-compatible controller.
The FIXTURE CONFIG menu contains additional settings for customizing behavior.
Master/slave operation – important guidelines
Fixtures operating in standalone mode can be synchronized in master/slave operation if they are
all connected to each other on a DMX data link as described under ‘Control data link’ on page 14.
In master/slave operation, one fixture running a standalone show – the ’master’ fixture –sends
‘fade’ and ’wait’ signals to the other fixtures running standalone shows – the ’slave’ fixtures – so
that scene change times in slave fixtures are synchronized with the scene change times in the
master. Every time the master changes to its next pre-programmed scene, the slave fixtures
change to their next pre-programmed scene at the same time.
Note the following:
•Although scene changes in master and slave fixtures all occur at the same time, scenes
do not have to be identical. You can program different effects in the standalone scenes of
different fixtures.
•Each fixture displays its own pre-programmed standalone show until it reaches its last
scene, then it starts the show sequence again and continues in a loop. If all fixtures have
the same number of scenes in their shows, they will all start shows in synch. If the
standalone shows in different fixtures have different numbers of scenes, the fixtures will
restart their shows at different times relative to each other.
•If no controller is connected to the first fixture on the link, you can improve the quality of
the data signal sent to slave fixtures by connecting a DMX termination plug (a plug with a
120 Ohm resistor across data hot and data cold) to the data input of the first fixture.
•DMX and RDM signals will override standalone operation in both the master and the slave
fixtures. This means that standalone operation is only possible if no DMX signal is present.
•You must set only the first fixture on the link to be the master fixture. Set all the other
fixtures as slaves. If you set more than one fixture to act as master, you may cause
damage that is not covered by the product warranty.
Exterior Projection 500 User Manual 19
Page 20
Setting up master/slave operation
Set up master/slave operation as follows:
1. Program a standalone show in each fixture as described under ‘Programming a standalone
show’ on page 17.
2. On each fixture, access the control menu and select FIXTURE CONFIG. Press ENTER.
3. Check that all fixtures are set to SLAVE. On the first fixture on the link – and only on this
fixture – select MASTER and press ENTER. Press MENU to return to the FIXTURE CONFIG
menu.
4. ON each fixture, scroll to OFFLINE MODE and press ENTER. Then select RUN SHOW and
press ENTER. Finally, press and hold MENU to exit the control menus.
5. Fixtures will now run standalone shows synchronized with the master fixture’s standalone
shows whenever the fixtures are powered on and not receiving a DMX control signal.
Offline mode – behavior without DMX
There are three options for setting how a fixture behaves when it is not receiving a DMX signal
(including when it is receiving a DMX signal but the signal is suddenly lost):
• RUN SHOW: Fixture executes pre-programmed scenes in a standalone show.
• DMX LAST STATE: Fixture holds and displays the last received DMX command.
• BLACK OUT (default): Fixture blacks out.
To set the desired behavior:
1. Access the control menu and select FIXTURE CONFIG. Press ENTER.
2. Press UP or DOWN to select one of the above three options. Press ENTER to confirm.
Note that for standalone and master/slave operation, OFFLINE MODE must be set to RUN
SHOW.
Setting the software to match the fixture variant
Important! The user should normally never need to change the Fixture Variant setting.
Change the setting with guidance from Martin Service only.
The Exterior 500 Projection firmware fixture software (firmware) can be configured to match one of
the following two fixture variants:
• Exterior Projection 500 FR (Framing – special fixture variant)
By default, the software is configured to match the Multigobo variant. To change this setting:
1. Select SET VARIANT from the main menu and press ENTER.
2. Select from:
a) EP500 MG (Exterior Projection 500 Multigobo, the default setting) or
b) EP500 FR (Exterior Projection 500 Framing).
3. Press ENTER to confirm.
Setting effect offsets
Important! The user should normally never need to change the Fixture Offsets setting.
Change the setting with guidance from Martin Service only.
It is possible to adjust the home position of each effect by setting an offset in the FIXTURE
OFFSET menu. Adjustments are held in memory when the fixture is powered off and on.
Offsets can be used to match multiple fixtures after they have been installed (if precise gobo
alignment is required, for example).
20 Exterior Projection 500 User Manual
Page 21
To reduce the risk of unauthorized tampering with the fixture, you must enter the service password
(123) before you can access the FIXTURE OFFSET menu.
Setup via RDM
The Exterior Projector 500 is compatible with RDM (Remote Device Management). Using an
RDM-compliant DMX controller, you can communicate with all the fixtures on a data link without
needing to access the fixture’s control panels or connect to each fixture individually. RDM lets you
set the DMX addresses of all the fixtures on the link, carry out basic fixture configuration and
retrieve basic fixture data.
Before you can communicate with fixtures, you will need to send a ‘Disc Unique Branch’ scan
command from the RDM controller to detect the devices on the data link. You can then send a ‘Get
Supported Parameters’ RDM command to retrieve a list of the Parameter IDs or messages,
supported by the fixture.
Exterior Projection 500 User Manual 21
Page 22
Effects
Strobe / shutter
The strobe / shutter effect provides instant open and blackout as well as variable speed regular
and random strobe effects.
Electronic dimming
Overall intensity can be adjusted 0-100%. 16-bit dimming resolution is available using two DMX
channels.
Color wheel
The color wheel contains the 8 dichroic color filters listed below plus an open (white) position.
Colors can be selected in full position steps or continuously scrolled for split colors. The color
wheel can be rotated with variable speed and direction. It can also be set to display random colors
at slow, medium and fast speeds. The color wheel is shown below viewed from the LED side (rear
of the fixture):
Color wheel
Slot 1: Red Slot 5: Dark Blue
Slot 2: Magenta Slot 6: CTO
Slot 3: Yellow Slot 7: Cyan
Slot 4: Green Slot 8: Orange
As an alternative to the above colors, Martin™ can supply custom color filters made to special
order. Please consult your Martin™ supplier for details.
22 Exterior Projection 500 User Manual
Page 23
Gobos
The fixture contains a rotating gobo wheel with the six rotating glass gobos shown below, viewed
from the front glass side (front of the fixture):
The gobos can be set to indexed positions and rotated continuously with variable speed and
direction.
To project a gobo, select the gobo and action type (indexed angle or rotation) on channel 5, then
adjust the indexed angle or direction and speed of rotation on channels 6 and 7 until you obtain
the projection you want. Using two channels for adjustment gives 16-bit control.
Gobos are user-replaceable. You can replace them with custom gobos made to your own design
provided that the gobos meet the quality and specifications of the Martin™ gobos supplied with the
fixture (see ‘Gobos’ on page 42).
Exterior Projection 500 User Manual 23
Page 24
Animation effect
The gobo animation effect is designed to be used in combination with a rotating gobo and color
filter to create a moving image of flames, grass blowing in the wind, water, etc.
Animation effect
Adjust the speed of the gobo rotation, the speed of the animation effect and fixture focus to give
the most realistic animation.
Prism
The fixture has one 4-facet linear rotating and one 3-facet radial rotating prism. Either prism can
be deployed to obtain rotating split beam effects. Each prism can be set to an indexed position or
rotated with variable speed and direction.
Either one of the prisms or the frost filter (see below) can be deployed at one time.
Frost
The frost filter softens the light output, giving a diffuse beam.
Focus
The motorized focus lets you adjust the sharpness of projections from the controller. Gobo
animation effects, for example, can be most effective if they are slightly out of focus.
24 Exterior Projection 500 User Manual
Page 25
Operation
Important! Keep power applied at all times during periods when the temperature may fall
below freezing point.
The Exterior Projection 500 is designed to operate at ambient temperatures between -30°C (-22° F)
and 45° C (113° F), but keep power applied constantly whenever the ambient temperature falls
below 0° C (32° F). This allows the fixture to warm up internal components, ensuring the correct
operation of moving parts and lubricants and avoiding undue wear.
If the fixture’s temperature rises above its normal operating range, its light output is regulated. As
the ambient temperature nears 45° C and if the fixture is exposed to strong sunlight, for example,
output intensity will be reduced in order to protect the fixture.
Projection image sizes
When projecting a gobo with an image of maximum size at a perpendicular surface (i.e. tilt angle
0° relative to the surface), you can obtain up to the following image sizes in the projection with the
various beam angle options available in the Exterior Projection 500:
Narrow
(12°)
Medium
(22°)
Wide
(36°)
Ver y Wide
(50°)
With an open gobo slot, you can obtain up to the following projection sizes:
Narrow
(12°)
4 m
(13 ft.)
0.7
(2.3)
1.2
(3.9)
2.3
(7.6)
3.1
(10.1)
Projection diameter, gobo with max. image size– in meters (ft.)
4 m
(13 ft.)
0.8
(2.6)
6 m
(20 ft.)
1.0
(3.4)
1.9
(6.1)
3.5
(11.4)
4.6
(15.2)
6 m
(20 ft.)
1.2
(3.9)
8 m
(26 ft.)
1.4
(4.6)
2.5
(8.1)
4.6
(15.2)
6.2
(20.3)
8 m
(26 ft.)
1.6
(5.3)
10 m
(33 ft.)
1.7
(5.7)
3.1
(10.2)
5.8
(19.1)
7.7
(25.3)
10 m
(33 ft.)
1.9
(6.2)
12 m
(39 ft.)
2.1
(6.8)
3.7
(12.2)
7.0
(22.9)
9.3
(30.4)
12 m
(39 ft.)
2.3
(7.5)
14 m
(46 ft.)
2.4
(8.0)
4.3
(14.1)
8.1
(26.7)
10.8
(35.4)
14 m
(46 ft.)
2.7
(8.9)
16 m
(53 ft.)
2.8
(9.1)
5.0
(16.2)
9.3
(30.5)
12.3
(40.5)
16 m
(53 ft.)
3.1
(10.2)
18 m
(59 ft.)
3.1
(10.2)
5.6
(18.3)
10.5
(34.3)
13.9
(45.6)
18 m
(59 ft.)
3.5
(11.4)
20 m
(66 ft.)
3.5
(11.4)
6.2
(20.3)
11.6
(38.1)
15.4
(50.6)
20 m
(66 ft.)
3.9
(12.8)
Medium
(22°)
Wide
(36°)
Ver y Wide
(50°)
Exterior Projection 500 User Manual 25
1.4
(4.6)
2.4
(7.9)
3.4
(11.2)
2.2
(7.2)
3.6
(11.8)
5.2
(17.0)
Projection diameter, open gobo – in meters (ft.)
2.9
(9.5)
4.8
(15.8)
6.9
(22.6)
3.6
(11.8)
6.0
(19.7)
8.6
(28.2)
4.3
(14.1)
7.2
(23.6)
10.3
(33.8)
5.0
(16.2)
8.4
(27.6)
12.0
(39.4)
(18.7)
(31.5)
13.8
(45.3)
5.7
9.6
6.4
(21.0)
10.8
(35.4)
15.5
(50.9)
7.2
(23.6)
12.0
(39.4)
17.2
(56.4)
Page 26
Maintenance
Warning! Read ‘Safety information’ on page 4 before servicing the fixture.
Important! Opening the fixture can allow moisture to enter and cause
condensation on the front glass. Read ‘Managing humidity’ on page 26 and
follow the guidelines in this user manual carefully.
Refer any service or repair operation not described in this manual to an authorized Martin™
service technician. Do not try to carry out such an operation yourself, as doing so may present a
health or safety risk. It may also cause damage or malfunction, and it may void your product
warranty.
Installation, on-site service and maintenance can be provided worldwide by the Martin™ Global
Service organization and its approved agents, giving owners access to Martin’s expertise and
product knowledge in a partnership that will ensure the highest level of performance throughout
the product’s lifetime. Please contact your Martin™ supplier for details.
Optical components have fragile coatings and are exposed to very high temperatures. Handle and
store components with care. Wear cotton gloves while handling them. Keep them perfectly clean
and free of oil and grease to reduce the risk of heat damage.
Cleaning
Regular cleaning is essential for fixture life and performance. Buildup of dust and dirt degrades the
fixture’s light output and cooling ability.
Cleaning schedules will vary greatly depending on the operating environment. It is therefore
impossible to specify precise cleaning intervals for the Exterior Projection 500. Inspect fixtures
within their first few weeks of operation to see whether cleaning is necessary. Check again at
frequent intervals. This procedure will allow you to assess cleaning requirements in your particular
situation. If in doubt, consult your Martin dealer about a suitable maintenance schedule.
Do not use products that contain solvents, abrasives or caustic agents for cleaning, as they can
cause surface damage to the fixture. The aluminum housing and front glass can be cleaned with
mild detergents such as those for washing cars.
To clean the housing and front glass:
1. Isolate the fixture from AC power and allow the fixture to cool for 20 minutes.
2. Visually check that the silicone seals and the power and data cables are in good condition. If
any seal or cable shows signs of damage, cracking or loss of water resistance, stop cleaning
the fixture and contact a Martin authorized service technician for replacement.
3. If seals are in good condition, rinse off loose dirt with a hose or low-pressure water spray.
4. Wash the aluminum housing and front glass using warm water with a little mild detergent and
a soft brush or sponge. Do not use abrasive cleaners.
5. Rinse with clean water and wipe dry.
Managing humidity
Martin™ Exterior fixtures are IP66-rated and are designed to resist water and moisture in
environments with widely varying climate, temperature and humidity conditions. But if fixtures are
not managed correctly during installation and service, water and moisture can enter, leading to
humidity and condensation inside the fixtures. Maximize the performance and service life of your
product by following the precautions in this section.
26 Exterior Projection 500 User Manual
Page 27
General
•Carry out service during low-humidly weather conditions (or indoors if possible). Check
that fixtures are dry and free of moist air before closing them.
• Tighten cover screws exactly as directed in this manual and using a torque driver.
• Make sure that all threads are clean and dry. Do not apply lubricant to threads before
assembly. While lubricant may make disassembly easier during future service, it means
that tightening screws to the specified torque will compress seals too much.
•Air and water can be sucked along cables and into fixtures. A cracked or porous cable
jacket can allow water into the cable. Replace any cable that is not in perfect condition.
Make sure that cables from fixtures open into dry areas (e.g. junction boxes in dry
locations).
•Do not clean fixtures with high-pressure water jets or immerse them.
Seals and sealing surfaces
The fixture must be sealed effectively. Covers have silicone seals that will withstand rain and water
splashing but will not withstand immersion or high-pressure water jets. Reinstall covers and seals
carefully if you have removed them.
•Make sure that seals and sealing surfaces are perfectly clean, dry and in perfect condition
before installing a cover. If you need to clean seals, use water and a soft cloth only.
Replace any seal that shows signs of aging, damage, cracking, stretching or deformation.
Replacement seals are available from Martin™.
• Reinstall seals in exactly their original position.
• Install seals so that they closely follow the profile of the metal parts they are installed on.
When you run your finger around the sealing surface after you have installed a cover, you
should not be able to feel any places where the seal sticks out or sinks into the gap
between the sealing surfaces.
•Do not use liquid gasket or any other type of sealant on sealing surfaces or seals.
Removing humidity using Evaporation Mode and silica gel desiccant
Each time you open the top cover, remove humidity from inside the fixture as directed in this
chapter before you close the fixture again. See ’Reinstalling the top cover’ on page 28.
Pressure relief valves
A valve with a Gore-Tex membrane on the back of the fixture (see ‘Fixture overview’ on page 8)
equalizes pressure by allowing air to pass through it when the fixture heats up and cools down, but
at the same time it acts as a barrier to water in liquid form. The expulsion of warm air (with a
slightly higher water vapor content) and intake of cool air (with a slightly lower water vapor content)
prevents humidity buildup over time, provided that the valve works correctly and the fixture is
correctly sealed.
Valves become blocked over time as the micropores in the membrane fill with particles. If a valve
becomes blocked by dirt or water, excess pressure can damage seals or cause air and even water
to be sucked into the fixture along cables. Valves cannot be cleaned and must be replaced if they
show any signs of contamination or if they are not in perfect condition.
To obtain the maximum service life from your fixture, follow these guidelines:
•Do not allow water to collect on or near valves. Do not install a fixture with the valve
membrane horizontal so that water can pool on it.
•Replace a valve with a new item if it shows any signs of contamination or is not in perfect
condition.
•Replace valves after an extended period of use. Intervals for valve replacement depend
on the installation environment.
•Consult your Martin™ dealer about a suitable valve replacement schedule. Contact
Martin™ Service for valve replacement
Exterior Projection 500 User Manual 27
Page 28
Removing and reinstalling the top cover
Important! Open the fixture in dry weather conditions only. Use Evaporation Mode and a new
silica gel desiccant bag to avoid humidity inside the fixture.
Access to optical components is made easy by a cover on the top of the fixture.
Removing the top cover
To remove the top cover:
1. Disconnect the fixture from power and allow it to cool for at least 60 minutes.
2. See illustrations below. Use a 5 mm Allen key (hex wrench) to remove the four top cover
screws (arrowed). Lift the top cover off the fixture. For ease of access – and if it is safe to do
so – you can unclip the safety cable and remove the cover completely from the fixture.
Reinstalling the top cover
To reinstall the top cover:
1. See illustration on right. Check the silicone
seal in the top cover. If it is not in perfect
condition, replace it with a new item from
Martin™.
2. If you unclipped the top cover safety cable,
reinstall the safety cable so that it will catch
the top cover and prevent it from falling while
screws are loosened.
3. Place the top cover loosely over the top of the
fixture so that air can enter and leave the
fixture.
28 Exterior Projection 500 User Manual
Page 29
4. Obtain a silica gel desiccant bag (P/N
37220000) from Martin™ and a cable tie
190 – 200 mm in length. Do not remove
the silica gel bag from its sealed
aluminum foil bag until you are ready to
install the bag as described below.
5. Go into the Service Evaporation Mode
control menu and select PASSWORD.
Scroll to the service password (default =
123) and press ENTER.
6. Select COVER OPEN and press ENTER.
7. Select EVAPORATION ON to set the fixture to Evaporation Mode. This allows warm, humid air
to leave the fixture and dry air to enter the fixture. WAIT will appear in the display.
8. After approx. 15 minutes the display will stop showing WAIT and start showing CLOSE
COVER. Press ENTER.
9. Remove the silica gel bag from its
aluminum foil bag. See illustration on
right. Using a cable tie, fasten the silica
gel bag to the Sub-D connector on the
effects module.
10. Check that the top cover safety cable is
correctly installed.
11. Reinstall the four top cover screws by
first inserting them finger-tight. Then
use a torque driver and cross-tighten
the screws in a diagonal pattern,
increasing torque gradually in stages
until you reach a torque of 1.8 Nm.
Exterior Projection 500 User Manual 29
Page 30
Replacing a rotating gobo
Gobos are user-replaceable, and you can replace them with custom gobos made to your own
design. Gobos are exposed to severe thermal stresses, however, so custom gobos must meet the
specifications and quality standards of the Martin™ gobos supplied with the fixture (see ‘Gobos’ on
page 42), or they can lead to damage that is not covered by the product warranty.
For a practical solution to custom gobo design when projection requirements are very specific,
order the Projection Setup Gobo (see below) from Martin™ and use it to map projection
characteristics at the installation site. You can then give precise data to the gobo designer to use
as a guide.
Projection Setup Gobo for the Exterior Projection 500, P/N 91616068
Gobos 1 – 4 are printed/coated glass and share the same specifications, but gobos 5 and 6 are
structured glass and have different specifications to the others. See ‘Gobos’ on page 42.
Goboholders 5 and 6 are not interchangeable with any other goboholders and must always be
installed in the slot they came from. Textured glass gobos must be installed in goboholders 5 and
6, and you must reinstall the thrust washers supplied with gobos 5 and 6 between the gobo
retaining spring and the gobo.
See illustration below. The goboholder in slot 4 has a magnet (arrowed) that the fixture uses to
recognize the position of the gobo wheel and gobos. If you replace gobos, make sure that you
always install this goboholder in its original position in slot 4.
30 Exterior Projection 500 User Manual
Page 31
The rotating gobos in the Exterior Projection 500 are installed in goboholders that clip into the
rotating gobo wheel.
To replace a gobo:
1. Remove the top cover as described under ’Removing and reinstalling the top cover’ on page
28.
2. See illustration below. Position the alignment mark (arrowed) in the goboholder at a reference
point such as the midpoint between the end of the motor mounting plate and multi-connector
shown below. Always remove and reinstall goboholders with alignment marks in the same
position so that you keep gobos in the same orientation.
3. See illustration below. Pull the goboholder forwards, away from the wheel, then lift it up out of
the wheel.
Exterior Projection 500 User Manual 31
Page 32
4. See illustration below. Place the goboholder on a clean, flat work surface with the teeth facing
upwards. The gobo is held in place in the gobo holder by a spring. Taking care to avoid
scratching or applying pressure to the gobo, lever the end of the spring out, remove the spring
and then lift the gobo out of the goboholder.
5. See illustration below. Hold the gobo with the dark side facing upwards towards the teeth in
the goboholder. Match up the alignment marks (arrowed) in the gobo and goboholder. Lay the
new gobo flat in the goboholder.
Gobos 5 and 6 only
Gobos 5 and 6 are structured glass and require a thrust washer. See illustration below. Place
the black thrust washer (arrowed) over the gobo before you go on to the next step.
32 Exterior Projection 500 User Manual
Page 33
6. See illustration below. Note the end of the gobo retaining spring with the bend (arrowed) that is
used for levering the spring out of the goboholder. Making sure that the bend in the spring is at
the top (as shown below), press the spring down into the goboholder until the spring clips into
its recess in the goboholder. Check that the spring is secure and that the gobo is still sitting flat
in the goboholder.
7. Hold the goboholder up to the rotating gobo wheel in its
original position. Rotate it until the alignment mark in the
goboholder lines up with the reference point as shown in
Step 3.
8. See illustrations below and right. Push the goboholder into
position, sliding the tongue that sticks out from the
goboholder into position (arrowed) behind the gobo
activation cog, pressing against the gobowheel.
Exterior Projection 500 User Manual 33
Page 34
9. Check that the goboholder is held securely. Rotate the whole gobowheel with your finger and
check that the goboholder rotates in the wheel while you rotate the gobowheel. If the
goboholder does not rotate, it is not correctly installed and its teeth are probably not engaged
correctly in the teeth in the gobowheel. Lift the goboholder out of the gobowheel and reinstall it
correctly.
10. Reinstall the top cover as described under ’Removing and reinstalling the top cover’ on page
2828.
Installing a glare shield accessory
A glare shield is available as an optional accessory for the Exterior Projection 500. The shield
protects from stray light and can help protect the fixture from damage caused by the sun shining
on the front of the fixture. The glare shield can be installed in seconds.
To install a glare shield:
1. See illustration below. Use a 3 mm Allen key (hex wrench) to remove the five screws (arrowed)
from the front of the fixture.
2. Fasten the glare shield securely to the fixture using the five screws as shown in the illustration.
Use a torque driver and cross-tighten to a torque of 0.7 – 1.1 Nm.
Shutter closed
Shutter open
Strobe (slow → fast)
Shutter open
Random strobe (slow → fast)
Dimmer
0-100%
Color selection
Continuous scrolling
Open
Split open/Color 1
Color 1
Split Color 1/Color 2
Color 2
Split Color 2/Color 3
Color 3
Split Color 3/Color 4
Color 4
Split Color 4/Color 5
Color 5
Split Color 5/Color 6
Color 6
Split Color 6/Color 7
Color 7
Split Color 7/Color 8
Color 8
Split Color 8/Open
Open
Stepped scrolling
Color 1
Color 2
Color 3
Color 4
Color 5
Color 6
Color 7
Color 8
Open
Continuous Rotation
Clockwise, fast → slow
Stop (wheel stops at its current position)
Counterclockwise, slow → fast
Random Slots
Fast
Medium
Slow
Fade/
Snap
Snap 30
Fade 0
Snap 0
Default
value
Exterior Projection 500 User Manual 35
Page 36
5
0 – 4
5 – 9
10 – 14
15 – 19
20 – 24
25 – 29
30 – 34
35 – 39
40 – 44
45 – 49
50 – 54
55 – 59
60 – 64
65-209
210 – 232
233 – 255
Gobo selection
(adjust action on next channels)
Gobo indexed position
Open
Gobo 1 indexed position
Gobo 2 indexed position
Gobo 3 indexed position
Gobo 4 indexed position
Gobo 5 indexed position
Gobo 6 indexed position
Gobo rotation
Gobo 1 rotation
Gobo 2 rotation
Gobo 3 rotation
Gobo 4 rotation
Gobo 5 rotation
Gobo 6 rotation
No function
Gobo indexing angle/rotation movement
(select gobo on previous channel)
Gobo indexing angle
Indexed position (0° Index at 32768)
Gobo rotation speed and direction
No rotation
CW rotation fast → CW slow
No rotation
CCW rotation slow → CCW fast
No rotation
Gobo animation
Open
Stop
Animation slow→ fast
Prism/frost selection
Open
Prism 1 indexing
Prism 2 indexing
Prism 1 rotation
Prism 2 rotation
Open
No frost → full frost
Prism Indexing
Indexed position, 0° Index at 128
Prism Rotation
No rotation (prism indexed at 0°)
Rotating CW fast → CW slow
No rotation (prism stops at current position)
Rotating CCW slow → CCW fast
No rotation (prism indexed at 45°)
Parameter shortcuts = ON (default)
Parameter shortcuts = OFF
Auto-blackout = On
Auto-blackout = OFF (default)
Illuminate display on fixture
Turn off display on fixture
No function
Snap 0
Exterior Projection 500 User Manual 37
Page 38
Control menus
To access the control menus, press the MENU button and hold for three seconds. Use the UP ▲
and DOWN ▼ buttons to navigate the menus. Select menu options using the ENTER button. Exit
menus using the MENU button.
Menu Sub-menu Notes
DMX
Address
Program
Show
Manual
Mode
Display
Setting
Fixture
Status
001~500 Set fixture’s DMX address
Set scene total 1-20
Strobe
Edit scene Scene 1~20
Set show times
Manual test
Reset Functions
Factory Default Yes / NO
Inverse On / Off
Display auto off No / Yes(1 minute) Display panel sleeps after 1 minute
Intensity 0%-100%Adjust display panel intensity
Display lock On / Off Enable/disable password entry
LED Temperature XXX C Temperature of LED engine
Power-on Hours XXXX (Hours)
Lamp Hours XXXX (Hours)
Software Version V1.0.0
Set hold time 0~99.9s Default = 4.0s
Set fade time 0~99.9s Default = 0.0s
Strobe 0-255
Intensity 0-100%
Color 0-255
… …
All
Color
Gobo
Prism/Frost
Focus
Animation
Intensity
Color
…
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Set total number of scenes in
standalone show
Set value 0-255 or percentage 0100% for each effect
Reset all effects
Reset color wheel
Reset gobo wheel
Reset prism and frost
Reset focus
Reset gobo animation
Return fixture to factory default
settings
Flip readout in display panel through
180°
Number of hours fixture has been
powered on since manufacture
Number of hours light output has
been activated since manufacture
Currently installed software
(firmware) version
38 Exterior Projection 500 User Manual
Page 39
Fixture
Service
Config
Master/Slave Master/Slave
Run show
Offline mode
DMX last state
Black out
EP500-MG
Select variant
EP500-FR
Password 0…999
LED
Temperature
Power-on
Hours
Fixture Status
Lamp Hours
Software
Version
XXX C Temperature of LED engine
XXXX
(Hours)
XXXX
(Hours)
V x.x.x
Password 0…999
Fixture Offset
Color -128~127
Gobos -128~127
… …
Evaporation Mode Password 0…999
Fixture acts as master or slave in
master/slave operation
Set only one fixture to be master!
When no DMX signal is present,
fixture runs standalone show
When no DMX signal is present,
fixture displays the last effect it was
displaying before the DMX signal
stopped
When no DMX signal is present,
fixture blacks out
Match software to fixture variant:
Exterior 500 Projection Multigobo
Exterior 500 Projection Framing
Set fixture’s control panel service
password (factory default password
is set to 123 but you can set a new
password here)
Number of hours fixture has been
powered on since manufacture
Number of hours light output has
been activated since manufacture.
Press Enter, then use service
password (factory default = 123) to
access option to reset lamp hours to
zero
Currently installed software
(firmware) version
Note: For use by Martin Service!
Enter user password (111) for
access to effect offsets. Then set an
offset in effect’s home position
Enter service password (factory
default = 123) for access to function.
To clear humidity, open top cover
slightly, press Enter. When message
to close cover appears in display,
close top cover, press Enter.
Default settings are shown in bold.
Exterior Projection 500 User Manual 39
Page 40
Troubleshooting
This section describes some problems that you may experience and provides some suggestions
for easy troubleshooting:
Symptom Potential cause Remedies
No light from
fixture.
Fixture does not
respond correctly
to DMX control.
Power supply issue such
as faulty connector or
damaged cable.
Incorrect DMX setup.
Fault in the DMX network
due to connector or cable
damage or potential
interference from proximity
to a high voltage
installation.
Internal fault.
Ensure that the mains supply is connected
and supplying power to the fixture. Check all
power connections and cables.
Ensure that fixture’s DMX address matches
address set on DMX control device.
Check that fixture’s status LED shows that it is
receiving DMX. If not, check all DMX cables
and connections.
Ensure that DMX link is terminated.
Check that all components on DMX link use
standard DMX polarity.
Attempt to control the fixture with another
DMX control device.
Move or shield the DMX link if it is close to an
unshielded high-voltage installation.
Contact your Martin authorized distributor or
Martin Global Service for assistance.
40 Exterior Projection 500 User Manual
Page 41
Specifications
Physical
Dimensions (LxWxH) ............................................ 293 x 313 x 586 mm (11.5 x 12.3 x 23.1 in.)
Weight ............................................................................................................ 17.5 kg (38.6 lbs.)
All figures include mounting yoke
Dynamic Effects
Color wheel ................................................................................................... 8 colors plus open
Exterior Projection 500, Very Wide, US, Aluminum ............................................. P/N 90506530
Exterior Projection 500 User Manual 43
Page 44
Photobiological safety warning
The warning shown below is printed on this product. If it becomes difficult or impossible to read, it
must be replaced with a label reproduced from the illustration below:
Disposing of this product
Martin™ products are supplied in compliance with Directive 2012/19/EC of the
European Parliament and of the Council of the European Union on WEEE (Waste
Electrical and Electronic Equipment), where applicable. Help preserve the
environment! Ensure that this product is recycled at the end of its life. Your supplier
can give details of local arrangements for the disposal of Martin products
RISK GROUP 3
WARNING Possibly hazardous optical
radiation emitted from this product. Do not
look at operating lamp. Eye injury may result.
AVERTISSEMENT Produit à émission de
radiations visibles potentiellement
dangéreuses. Ne pas regarder le faisceau en
fonctionnement. Risque de lésions oculaires.