Martin ELP PAR IP User Manual [EN]

Page 1
ELP PAR IP
User Guide
Page 2

Dimensions

©2022-2023 HARMAN PROFESSIONAL DENMARK ApS. All rights reserved. Features, specifications and appearance are subject to change without notice. HARMAN PROFESSIONAL DENMARK ApS and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. Martin is a registered trademark of HARMAN PROFESSIONAL DENMARK ApS registered in the United States and/or other countries.
HARMAN PROFESSIONAL DENMARK ApS, Olof Palmes Allé 44, 8200 Aarhus N,
Denmark
HARMAN PROFESSIONAL SOLUTIONS U.S., 8500 Balboa Blvd., Northridge CA 91329,
USA
www.martin.com
ELP PAR IP User Guide Revision B
All dimensions are
in millimeters
Page 3
Table of contents
Dimensions ........................................................................................... 2
Safety information ................................................................................. 4
Introduction ......................................................................................... 10
Before using the product for the first time ..................................... 10
Fixture overview ................................................................................. 11
Physical installation ............................................................................ 12
Standing the fixture on a flat, horizontal surface ........................... 12
Fastening the fixture to a flat surface ............................................ 13
Mounting the fixture on a truss ...................................................... 13
Securing with a safety cable ......................................................... 14
Connecting to AC power ..................................................................... 15
Linking fixtures to power in a chain ............................................... 16
Connecting to data ............................................................................. 17
Tips for reliable data transmission ................................................ 17
Connecting the DMX data link....................................................... 18
Fixture setup ....................................................................................... 19
DMX address setting ..................................................................... 20
DMX mode .................................................................................... 20
Dimming curves ............................................................................ 21
Dimming speed and smoothness .................................................. 22
Blackout or Hold if DMX signal stops ............................................ 22
Scene capture ............................................................................... 22
Cooling mode ................................................................................ 23
Display rotation ............................................................................. 23
Display intensity ............................................................................ 24
Temperature units ......................................................................... 24
Resetting to factory defaults ......................................................... 24
Fixture test .................................................................................... 24
Fixture information ........................................................................ 25
DMX Live ...................................................................................... 26
Resetting the fixture ...................................................................... 26
Manual control .............................................................................. 27
Focus shortcut .............................................................................. 27
Control / Settings DMX channel .................................................... 28
Effects ................................................................................................ 29
RDM ................................................................................................... 31
Maintenance ....................................................................................... 33
Cleaning ........................................................................................ 33
Uploading new firmware ............................................................... 34
Service and repairs ....................................................................... 35
DMX protocol – Basic Mode (default) ................................................. 36
DMX protocol – Compact Mode .......................................................... 40
Control menus .................................................................................... 41
Troubleshooting .................................................................................. 46
Specifications ..................................................................................... 47
Page 4
4 Martin® ELP PAR IP User Guide

Safety information

WARNING!
Read the safety precautions in this manual before
installing, operating or servicing this product.
The following symbols are used to identify important safety information on the product and in this manual:
Warning!
Safety hazard. Risk of severe
injury or death.
Warning!
Powerful light
emission. Risk
of eye injury.
Warning!
See user
manual for
important
safety
information.
Warning!
Hazardous
voltage. Risk
of lethal or
severe electric
shock.
Warning!
Hot surfaces
and fire hazard.
Warning! Risk Group 2 product according to EN 62471 and IEC/TR 62778. Possibly hazardous radiation emitted from this product. May be harmful to the eyes. Do not stare at operating lamp and do not view the light output with optical instruments or any device that may concentrate the beam.
This lighting fixture is for professional use only and must be installed by a qualified technician. It is not for household use. It presents risks of severe injury or death due to fire hazards, electric shock and falls. It produces a powerful, concentrated beam of light that can create a fire hazard or a risk of eye injury if the safety precautions below are not followed. Respect all locally applicable laws, codes and regulations when installing, operating or servicing the fixture.
The light source contained in this fixture must be replaced by Martin Service or an authorized Martin Service partner only.
Page 5
Martin® ELP PAR IP User Guide 5
Install, operate and service Martin products only as directed in their user manuals, or you may create a safety hazard or cause damage that is not covered by product warranties.
Follow the safety precautions listed below and observe all warnings in this manual and printed on the product. Before you install, operate or service the fixture, check the Martin website at www.martin.com and make sure that you have the latest user documentation for the fixture. Document revisions are indicated at the bottom of page 2.
Technical Support
If you have questions about how to install or operate the fixture safely, please contact Harman Professional Technical support:
For technical support in North America, please contact: HProTechSupportUSA@harman.com Phone: (844) 776-4899
For technical support outside North America, please contact your national distributor.
Protection from electric shock
Disconnect the fixture from AC power before carrying out any installation or maintenance work and when the fixture is not in use.
Ensure that the fixture is electrically connected to ground (earth).
Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixture can easily be disconnected from power.
Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or other component is damaged, defective, deformed, shows signs of water ingress or showing signs of overheating. Do not reapply power until repairs have been completed.
Page 6
6 Martin® ELP PAR IP User Guide
Before using the fixture, check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices.
Use only Neutrik powerCON TRUE1 TOP cable connectors
to connect to the fixture’s power sockets. Do not connect devices to power in a chain that will exceed
the electrical ratings of any cable or connector used in the chain.
To connect fixtures to mains power in a chain, you must first obtain 12 AWG or 2.5 mm2 power input and throughput cables that are 16 A rated and temperature-rated to suit the application. In the USA and Canada the cables must be UL­listed, type SJT or equivalent. In the EU the cables must be type H05VV-F or equivalent. Suitable cables with Neutrik powerCON TRUE1 TOP connectors are available from Martin (see Accessorieson page 49). If you use these cables, you can connect fixtures to power in a linked chain, POWER OUT throughput socket to POWER IN input socket, but do not link more than:
four (4) ELP PAR IP fixtures in total at 100-120 V, or
seven (7) ELP PAR IP fixtures in total at 200-240 V.
If you intend to connect other devices to the POWER OUT socket in a daisy chain, add together the maximum current draw of all the devices in the chain. Do not create a chain of devices whose total maximum current draw will exceed the maximum current rating of any connector in the chain. The maximum permitted current at the POWER IN connector is 16 A. The maximum permitted current at the POWER OUT connector is 12 A.
The voltage and frequency at the POWER OUT socket are the same as the voltage and frequency applied to the POWER IN socket. Only connect devices to the POWER OUT socket that accept this voltage and frequency.
The fixture has an ingress protection rating of IP65. Do not immerse it. Do not expose it to high-pressure water jets.
The fixture is rated IP65 only when the following types of connector are used on cables connected to the fixture:
Neutrik powerCON TRUE1 NAC3FX-W (TOP) type connector at the power IN socket,
Page 7
Martin® ELP PAR IP User Guide 7
Neutrik powerCON TRUE1 NAC3MX-W (TOP) type connector at the power OUT/THRU socket,
Neutrik TOP type 5-pin locking XLR connectors at the XLR (DMX, RDM) data sockets.
Use only these connector types and use only cables that are suitable for the given application with respect to humidity, water and sunlight resistance.
The power and data connectors are fitted with rubber caps to protect from water ingress. Keep rubber caps installed at all times on all connectors that are not in use.
Arrange cables so that they arrive at connectors from below. With this arrangement, gravity will cause any condensation or water droplets to run away from connectors.
In wet locations, do not install the fixture with the connections panel facing upwards.
Do not cover, immerse or block the pressure equalization valve on the rear of the fixture.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
The surface of the product casing can reach up to 71° C (160° F) – TBC during operation. Avoid contact by persons and materials. Allow the fixture to cool for at least 15 minutes before handling.
Keep flammable materials well away from the fixture. Keep all combustible materials (e.g. fabric, wood, paper) at least
0.5 m (1.7 ft.) away from the fixture housing.
Ensure that there is free and unobstructed airflow around the fixture. Provide a minimum clearance of 0.5 m (1.7 ft.) around fans and air vents.
Do not use the fixture to illuminate surfaces within 1 m (3.3 ft.) of the fixture.
Do not stick filters, masks or other materials onto any optical component.
The fixture’s lenses can focus the sun’s rays, creating a risk of fire and damage. Do not expose the front of the fixture to sunlight or any other bright light source.
Page 8
8 Martin® ELP PAR IP User Guide
Protection from eye injury
Warning! Risk Group 2 product according to EN 62471 and IEC/TR 62778.
The ELP PAR IP fixture falls into the following risk groups according to EN 62471 and IEC/TR 62778 at the distances indicated below.
The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 21.5 m is not expected.
Do not look directly into the product’s light output. Do not look at operating lamp. Eye injury may result. Do not look at the light output with magnifiers, telescopes,
binoculars or similar optical instruments that may concentrate the light output.
Ensure that persons are not looking directly into the front of the fixture when the product lights up suddenly. This can happen when power is applied, when the product receives a DMX signal, or when certain control menu items are selected.
To minimize the risk of eye irritation or injury, disconnect the fixture from power at all times when the fixture is not in use and provide well-lit conditions to reduce the pupil diameter of anyone working on or near the fixture.
Protection from injury
The fixture is not portable when installed. Ensure that any supporting structure and/or hardware used
can hold at least 10 times the weight of all the devices they support.
Page 9
Martin® ELP PAR IP User Guide 9
If suspending from a rigging structure, fasten the fixture to a rigging clamp. Do not use safety cables as the primary means of support.
If the fixture is installed in a location where it may cause injury or damage if it falls, install as directed in this manual a secondary attachment such as a safety cable that will hold the fixture if a primary attachment fails. The secondary attachment must be approved by an official body such as TÜV as a safety attachment for the weight that it secures, must comply with EN 60598-2-17 Section 17.6.6 and must be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories.
Check that all external covers and rigging hardware are securely fastened.
Block access below the work area and work from a stable platform whenever installing, servicing or moving the fixture.
Do not operate the fixture with missing or damaged covers, shields or any optical component.
In the event of an operating problem, stop using the fixture immediately and disconnect it from power. Do not attempt to use a fixture that is obviously damaged.
Do not modify the fixture in any way not described in this manual or install other than genuine Martin parts.
Refer any service operation not described in this manual to a qualified technician.
Page 10
10 Martin® ELP PAR IP User Guide

Introduction

The ELP PAR IP is an IP65-rated bright LED PAR Can with calibrated color output from seven RGBW LEDs and a motorized zoom. It offers electronic dimming and strobe and features a bracket for floor or truss mounting.
The ELP PAR IP can be controlled using any DMX-compliant controller. The fixture is supplied with a folding mounting bracket.

Before using the product for the first time

1. Read ‘Safety information’ on page 4 before installing, operating or servicing the fixture.
2. Unpack and ensure that there is no transportation damage before using the fixture. Never attempt to operate a damaged fixture.
3. Check that the voltage and frequency of the local power source match the mains power requirements of the fixture.
4. Either hard-wire the fixture to an AC mains power source or provide a power input cable and local power plug as described in this manual and connect to an AC mains power outlet.
5. Check the support pages on the Martin Professional website at www.martin.com for the most recent user documentation and technical information about the fixture. Martin user manual revisions are identified by the revision letter at the bottom of the inside cover.
Be prepared for the fixture to suddenly emit bright light when power is applied.
Page 11
Martin® ELP PAR IP User Guide 11

Fixture overview

1 - Display 2 – Control buttons 3 – Tilt adjustment handle 4 – DMX IN (Neutrik IP-rated 5-pin locking XLR) 5 – Mains power IN (Neutrik powerCON TRUE1 TOP) 6 – Mains power THRU (Neutrik powerCON TRUE1 TOP) 7 – Pressure equalization valve 8 – DMX THRU (Neutrik IP-rated 5-pin locking XLR) 9 – Folding floor stand / mounting bracket
3
8
1
2
5
4
6 7
9
Page 12
12 Martin® ELP PAR IP User Guide

Physical installation

Read ‘Safety information’ on page 4 before installing the fixture.
The fixture must be used in a location with adequate ventilation. Ensure that there is free airflow around the fixture.
You can either fasten the fixture to a secure structure (such as a rigging truss) or surface. You can also stand it on a secure surface. Do not place the fixture in a location where it can be moved, fall over, or present a danger of tripping or injury.
If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails.
Martin can supply safety cables and rigging clamps that are suitable for use with the fixture (see ‘Accessories’ on page 49).

Mounting bracket angle scales

See illustration on right. The fixture’s mounting bracket has angle scales printed on both sides next to the adjustment handles. The scales show the precise angle at which the head is tilted. There are two scales. The inner scale is for use when standing the fixture on the floor. The outer scale is for use when flying the fixture overhead.

Standing the fixture on a flat, horizontal surface

Use a stable horizontal surface that can support at least 10 times the weight of all the fixtures and equipment that it will support.
See illustration on right. The fixture can be placed on the surface by releasing the adjustment handles (arrowed) on both sides of the fixture, fully opening the legs of the mounting bracket, and then re-tightening the adjustment handles.
Page 13
Martin® ELP PAR IP User Guide 13

Fastening the fixture to a flat surface

Use a stable horizontal surface that can support at least 10 times the weight of all the fixtures and equipment that it will support. Ensure that all fasteners used can support at least ten times the weight of all the fixtures and equipment that they will support.
To fasten the fixture to a surface:
1. See illustration on left. Pass an M12, grade 8.8 steel
minimum, bolt or screwbolt through the hole (arrowed) in the center of the main mounting bracket leg and into the surface.
2. If using a bolt, secure with a washer and self-locking nut.
3. Check that the fixture is held securely.
4. If you install the fixture in a location where it may
cause injury or damage if it falls, secure it as directed
below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.

Mounting the fixture on a truss

The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in any other orientation, you must use a half-coupler clamp (see illustration on right) that completely encircles the truss chord.
To clamp the fixture to a truss:
1. Check that the rigging structure can support at least ten times the weight of all fixtures and equipment to be installed on it.
2. Block access under the work area.
3. Either:
- Bolt a rigging clamp directly to the fixture’s mounting bracket using
an M12 grade 8.8 steel bolt and self-locking washer, or
Page 14
14 Martin® ELP PAR IP User Guide
- Bolt a rigging clamp to a Martin omega
bracket (available as an accessory by ordering P/N 91602001 from your Martin supplier) using a grade 8.8 steel bolt. See illustration on right. Fold the legs of the fixture’s mounting bracket together and fasten the omega bracket securely to the mounting bracket. Turn the quarter-turn fasteners on the omega bracket a full 90° to lock.
4. Working from a stable platform, hang the fixture
with its clamp on the truss and fasten the clamp securely.
5. Loosen the adjustment handles on both sides of the fixture, adjust the fixture’s tilt angle, and re-tighten the handles.
6. Secure the fixture with a safety cable as directed below.

Securing with a safety cable

1. Obtain a safety cable (or other secondary attachment) that is approved for the weight of the fixture.
2. See illustration on right. The fixture’s safety cable attachment point (arrowed) is located between the cooling ribs on the top of the fixture. Fasten the cable to this attachment point by either looping it around the attachment point or using a carabiner clip.
Do not simply loop the safety cable around the legs of the mounting bracket, as this will leave the fixture unsecured if the fixture separates from the mounting bracket.
3. Remove as much slack as possible from the safety cable and fasten it to a secure anchoring point.
4. Make sure that the safety cable will hold the fixture if a primary attachment fails.
Your Martin dealer can supply suitable safety cables and rigging clamps (see ‘Accessories’ on page 49).
Page 15
Martin® ELP PAR IP User Guide 15

Connecting to AC power

Read ‘Safety information’ on page 4 before connecting
the fixture to AC mains power.
Before you connect other fixtures to the POWER OUT socket, see ‘Linking fixtures to power in a chain’ on page 16.
For protection from electric shock, the fixture must be grounded (earthed). The power distribution circuit must be equipped with a fuse or circuit breaker and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixture can easily be disconnected from power.
Do not use an external dimming system to supply power to the fixture, as this may cause damage to the fixture that is not covered by the product warranty.
The fixture requires a power input cable with a Neutrik powerCON TRUE1 NAC3FX-W TOP female cable connector for AC mains power input. The cable must meet the requirements listed under “Protection from electric shock” on page 5. Martin can supply suitable cables with female TRUE1 TOP input connectors 1.5 m (4.9 ft.) or 5 m (16.4 ft.) long, as well as loose female TRUE1 TOP input connectors (see “Accessories” on page 49).
The fixture can be hard-wired to a building electrical installation if you want to install it permanently, or a power plug that is suitable for the local power outlets can be installed on the power cable. If you install a power plug on the power cable, follow the plug manufacturer’s instructions and connect the wires in the power cable as shown in this table:
Earth, Ground or
Neutral or N
Live or L
US system
Green
White
Black
EU system
Yellow/green
Blue
Brown
The fixture has an auto-ranging power supply that accepts AC mains power at 100-120/200-240 V at 50/60 Hz. Do not apply AC mains power at any other voltage or frequency to the fixture.
Page 16
16 Martin® ELP PAR IP User Guide

Linking fixtures to power in a chain

If you obtain a 12 AWG / 2.5 mm2 power input cable and 12 AWG / 2.5 mm2 throughput cables from Martin (see “Accessories” on page 49), you can relay mains power from one fixture to another by connecting fixtures to power in a linked daisy-chain, POWER OUT throughput socket to POWER IN input socket.
Using 12 AWG / 2.5 mm2 cables from Martin, you can create a daisy chain of linked fixtures that contains:
maximum four (4) ELP PAR IP fixtures in total at 100-120 V, or
maximum seven (7) ELP PAR IP fixtures in total at 200-240 V.
Page 17
Martin® ELP PAR IP User Guide 17

Connecting to data

Read ‘Safety information’ on page 4 before connecting
the fixture to a control data source.
A DMX 512 data link is required in order to control the fixture via DMX. The fixture has 5-pin XLR connectors for DMX data input (IN) and output (THRU).
The number of daisy-chained fixtures is limited by the number of DMX channels required by the fixtures in relation to the maximum 512 channels available in one DMX universe. Note that if independent control of a fixture is required, it must have its own DMX channels. Fixtures that are required to behave identically can share the same DMX address and channels. To add more fixtures or groups of fixtures when the above limit is reached, add a DMX universe and another daisy-chained link.

Tips for reliable data transmission

Use shielded twisted-pair cable designed for RS-485 devices: standard microphone cable cannot transmit control data reliably over long runs. 24 AWG cable is suitable for runs up to 300 meters (1000 ft.). Heavier gauge cable and/or an amplifier is recommended for longer runs. The pinout on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+). Pins 4 and 5 in the 5-pin XLR connectors are not used in the fixture but are available for possible additional data signals as required by the DMX512-A standard. Standard pinout is pin 4 = data 2 cold (-) and pin 5 = data 2 hot (+).
If you need to split the link into branches, use an opto-isolated splitter. Use an RDM-compatible splitter when using RDM.
Terminate the link by installing a DMX termination plug in the output socket of the last fixture. The termination plug, which is a male XLR plug with a 120 Ohm, 0.25 W resistor soldered between pins 2 and 3, “soaks up” the control signal so it does not reflect and cause interference. If a splitter is used, terminate each branch of the link.
Page 18
18 Martin® ELP PAR IP User Guide

Connecting the DMX data link

To connect the fixture to data:
1. Connect the DMX data output from the controller to the first fixture’s male XLR DMX input connector.
2. Connect the first fixture’s DMX output to the DMX input of the next
fixture and continue connecting fixtures output to input. Terminate the last fixture on the link with a DMX termination plug.
Page 19
Martin® ELP PAR IP User Guide 19

Fixture setup

This section explains the fixture characteristics that can be set to determine how it can be controlled and will behave. These settings are made using the menus available in the control panel. Settings are retained in memory when the fixture is powered off.
You can find a complete map of the control menu structure in Control menuson page 40.

Using the control menus

To access the control menus or to return to the next highest level in the menu structure, press the MENU button.
Navigate the menu structure using the DOWN, UP and ENTER buttons.
If you have selected a menu option, confirm your selection and set that
option using the ENTER button, or if you want to return to the next highest level in the menu structure without making a change, press the MENU button.
To exit the menus, press the MENU button.

Special keypress functions

Holding the UP button and pressing the DOWN button rotates the control panel display through 180°.
Holding the MENU button and pressing the UP button resets the entire fixture.
Holding the ENTER button pressed for two seconds puts the fixture into Focus shortcut mode for one minute (see ‘Focus shortcut’ on page 27).
MENU
Activate the control menus, or
open the Shortcuts menu by holding for 2 seconds,
or
return to the previous level of the menu structure, or
press to exit the menus
DOWN
Go down a menu level
UP
Go up a menu level
ENTER
Confirm the selected function
Hold for 2 seconds to enter Focus shortcut mode
Page 20
20 Martin® ELP PAR IP User Guide

Menu shortcuts

Pressing and holding the MENU button for two seconds opens a small Shortcuts menu with the following items:
RESET ALL carries out a complete reset of the fixture with all its effects.
ROTATE DISPLAY rotates the control panel display through 180°. This
function makes it easier to read the control panel menus when changing from standing to hanging installation.
PERSONALITY OVERVIEW displays a list of the fixture’s personality settings. Use the DOWN and UP buttons to scroll through the list.

DMX address setting

The DMX address, also known as the start channel, is the first channel used to receive instructions from a DMX controller. The fixture uses 14 DMX channels. This means that if you have a group of fixtures and you set the first fixture’s DMX address to 1, then DMX address 15 is available for the next fixture, DMX address 29 for the fixture after that, and so on.
For independent control, each fixture must be assigned its own control channels. You can give the same DMX address to two fixtures of the same type if you want them to behave identically. Giving the same DMX address to multiple fixtures can be useful for grouped control and troubleshooting.
To set the fixture’s DMX address:
1. In the fixture’s control panel, use the UP and DOWN buttons to select
DMX ADDRESS and press ENTER. The fixture’s currently set DMX address will blink in the display.
2. Use the UP and DOWN buttons to select a new address.
3. Once the new address has been selected, press ENTER to confirm it (or press MENU to exit without making a change).

DMX mode

Two DMX modes are available:
Basic Mode is the default DMX mode. It gives control of all the feature’s effects as well as the Control/Settings channel that lets you configure the fixture over the DMX link. Basic Mode uses 14 DMX channels.
Compact Mode is a reduced mode with a smaller DMX footprint. It gives control of a reduced number of effects, with 8-bit RGB control and does not give access to the Control/Settings channel. Compact Mode uses 9 DMX channels.
Page 21
Martin® ELP PAR IP User Guide 21

Extended, raw and calibrated modes

In extended mode the fixture is white calibrated. In raw mode, the fixture is completely uncalibrated and all LEDs operate at
up to full intensity. The color output of one fixture may not exactly match that of other fixtures.
In calibrated mode, LED intensity is slightly reduced where necessary in order to ensure that each fixture’s color output matches that of other fixtures.

Tungsten emulation mode

In tungsten emulation mode, the fixture’s white light output is made warmer,
the warm shift is increased at lower dimming levels, fading in is smoother
and an ‘afterglow‘ effect is added when fading out. This mode gives the ‘look and feel’ of a fixture that uses an incandescent light bulb as its source.

Dimming curves

Four dimming curves are available:
LINEAR The increase in light intensity appears to be linear as DMX value is increased.
SQUARE LAW light intensity control is finer at low levels and coarser at high levels.
INVERSE SQUARE LAW light intensity control is coarser at low levels and finer at high levels.
S-CURVE light intensity control is finer at low levels and high levels and coarser at medium levels.
To set the fixture’s dimming curve:
1. Select DIMMER CURVE and press ENTER. The currently set dimming curve mode will blink in the display.
2. Use the DOWN and UP buttons to select LINEAR, SQUARE LAW, INV SQ LAW, or S-CURVE.
3. Press ENTER to confirm your choice (or press MENU to exit without making a change).
Page 22
22 Martin® ELP PAR IP User Guide

Dimming speed and smoothness

You can optimize dimming to give either the fastest or the smoothest changes in dimming levels. To optimize dimming:
1. Select DIMMING SPEED and press ENTER.
2. Use the DOWN and UP buttons to select FAST (dimmer optimized for speed) or SLOW (dimmer optimized for smoothness).
3. Press ENTER to confirm your choice (or press MENU to exit without making a change).

Blackout or Hold if DMX signal stops

You can decide how the fixture should behave if you are controlling the fixture via DMX and then you stop sending the DMX data signal:
1. Select NO DATA MODE and press ENTER. The currently set mode will blink in the display.
2. Using the DOWN and UP buttons, select BLACKOUT or HOLD to decide how the fixture should respond if it stops receiving a DMX signal:
- If you select BLACKOUT, the fixture will black out
- If you select HOLD, the fixture will continue to show the effect that it
is displaying at the time.
3. Press ENTER to confirm your choice (or press MENU to exit without making a change).

Scene capture

The SCENE CATCH menu lets you capture all the DMX values that the
fixture is currently receiving and save them as a ‘scene’ that you can choose
to play back each time the fixture power is cycled off and on or each time that you carry out a reset.
Three scene capture controls are available:
SCENE CATCH RECORD stores the currently displayed scene in the fixture’s memory. Once you have captured a scene, the fixture keeps that scene in memory even if you cycle power off and on again.
SCENE CATCH = ON sets the fixture to show the scene that is stored in memory if the fixture stops receiving a DMX signal.
If the fixture receives a DMX control signal during scene playback, it will immediately stop showing its saved scene. If fixture power is cycled off and on again or if the fixture is reset, it will again show its saved scene.
SCENE CATCH = OFF disables the scene playback function: the fixture does not show the scene that is stored in memory.
Setting SCENE CATCH to OFF does not delete the saved scene from
Page 23
Martin® ELP PAR IP User Guide 23
memory: the scene will still be available if you set SCENE CATCH to ON again.

Cooling mode

The cooling mode setting lets you decide whether to give priority to lowest noise level or maximum light output:
1. Select COOLING MODE and press ENTER. The currently set mode will blink in the display.
2. Using the DOWN and UP buttons, select one of the three cooling options:
- If you select REGULATED FANS, the fans operate at normal speed.
Temperature regulation increases fan speed if the fixture approaches its maximum operating temperature. This setting provides a good compromise between low fan noise and powerful light output.
- If you select THEATER MODE, the fans operate at lower speed.
Temperature regulation reduces maximum light output if the fixture approaches its maximum operating temperature. This setting gives priority to the lowest possible noise.
The THEATER MODE setting also increases the LED PWM frequency to 19 200Hz to ensure flicker-free high speed video recording.
- If you select FULL, the fans operate at full speed without
temperature regulation. This setting maximizes cooling and gives priority to the highest possible light output intensity. FULL fan mode can also be used as a quick way of dislodging dirt from fans.
3. Press ENTER to confirm your choice (or press MENU to exit without making a change).

Display rotation

The fastest way to rotate the control panel display through 180° to match the fixture’s orientation is to press and hold the UP button and then press the DOWN button.
You can also rotate the display using the DISPLAY control menu:
1. Select DISPLAY DISPLAY ROTATION and press ENTER.
2. Use the DOWN and UP buttons to select NORMAL (display in normal
orientation) or ROTATE 180° (display inverted to make it easier to read if you install the fixture hanging vertically from its mounting bracket).
3. Press ENTER to confirm your choice (or press MENU to exit without making a change).
Page 24
24 Martin® ELP PAR IP User Guide

Display intensity

To set the brightness of the control panel display:
1. Select DISPLAY DISPLAY INTENSITY and press ENTER.
2. Use the DOWN and UP buttons to adjust the brightness of the display from 10% to 100%.
3. Press ENTER to confirm your choice (or press MENU to exit without making a change).

Temperature units

To set the fixture to display temperatures in degrees Celsius or Fahrenheit:
1. Select DISPLAY TEMPERATURE UNIT and press ENTER.
2. Use the DOWN and UP buttons to select °C or °F.
3. Press ENTER to confirm your choice (or press MENU to exit without making a change).

Resetting to factory defaults

To reset the fixture to its factory default settings:
1. Select FACTORY DEFAULT and press ENTER to confirm.
2. Use the DOWN and UP buttons to select YES to erase any custom
settings that you have configured and reset the fixture to its factory default settings, or select NO.
3. Press ENTER to confirm your choice (or press MENU to exit without making a change).

Fixture test

You can run an automatic sequence to test all the fixture’s effects or manually test individual effects using the control menus.

Automatic effects test

To perform a complete test of all of the fixture’s effects:
1. Select FIXTURE TEST TEST ALL and press ENTER to confirm. The automatic test will run.
2. To stop the test and return to the previous level of the menu structure, press MENU.

Manual effects tests

You can also manually test individual effects. To test LED dimming:
1. Select FIXTURE TEST TEST DIMMER and press ENTER.
Page 25
Martin® ELP PAR IP User Guide 25
2. To stop the test and return to the previous level of the menu structure, press MENU.
To test an individual effect:
1. Select FIXTURE TEST TEST EFFECTS and press ENTER.
2. Use the DOWN and UP buttons to select RED, GREEN, BLUE, CTC,
COLOR (this tests the virtual color wheel effect), or ZOOM. Press ENTER to confirm your selection. The fixture will now run an automatic test of the selected effect.
3. Press MENU to exit the test and return to the list of effects.

Fixture information

Power on time

1. Select INFORMATION POWER ON TIME and press ENTER to display the total number of hours the fixture has been powered on since it left the factory.
2. To return to the previous level of the menu structure, press MENU.

LED operating time

1. Select INFORMATION LED HOURS and press ENTER to display the total number of hours the LEDs have been activated since the fixture left the factory.
2. To return to the previous level of the menu structure, press MENU.

Firmware version

To see which software version is installed in the fixture:
1. Select INFORMATION SW VERSION and press ENTER. The display will indicate the currently installed firmware version.
2. Use the UP and DOWN buttons to scroll through firmware revisions.
3. To return to the previous level of the menu structure, press MENU.

Fixture ID number

You can set a custom 4-digit ID number for the fixture to help you identify it. To manage the ID number:
1. Select INFORMATION FIXTURE ID and press ENTER. The display will indicate the current fixture ID number.
2. Use the DOWN and UP buttons to increase or decrease the current
fixture ID number until you reach the ID number that you want to allocate to the fixture.
3. Press ENTER to confirm the new ID number (or press MENU to exit without making a change).
Page 26
26 Martin® ELP PAR IP User Guide

RDM unique ID number

You can view the fixture’s unique non-resettable 12-digit RDM ID number. To view the RDM UID number:
1. Select INFORMATION RDM UID and press ENTER. The display will indicate the fixture’s unique RDM ID number.
2. Press MENU to exit.

Fixture temperature readouts

To check the onboard temperature of the fixture:
1. Select INFORMATION TEMPERATURES and press ENTER. The
fixture will display on two lines the current temperatures of the LED PCB and of the PSU PCB.
2. To return to the previous level of the menu structure, press MENU.

Fan speed readouts

To view the current speed of each of the fixture’s cooling fans in RPM:
1. Select INFORMATION FAN SPEED and press ENTER. The fixture
will display on two lines the current speeds in RPM of the LED PCB cooling fan and of the PSU PCB cooling fan.
2. To return to the previous level of the menu structure, press MENU.

DMX Live

You can view the DMX values currently being received on each of the fixture’s DMX channels. This can be useful for troubleshooting purposes.
To view the DMX values being received:
1. Select DMX LIVE and use the UP and DOWN buttons to scroll through the value being received on each channel.
2. To return to the previous level of the menu structure, press MENU.

Resetting the fixture

You can reset the entire fixture to return it to its state when you powered it on, or you can reset its effects only.
To carry out a full reset, select MANUAL CONTROL RESET ALL, select YES or NO and press ENTER. The entire fixture will reset as if you had cycled power. The reset process will take several seconds.
To reset only the fixture’s effects, select MANUAL CONTROL → RESET EFFECTS and press ENTER. The fixture’s effects will reset. The
effects reset process will take several seconds.
Page 27
Martin® ELP PAR IP User Guide 27

Manual control

You can control the fixture’s effects manually without needing a DMX signal.
This lets you set up a stand-alone scene. To manually control the fixture:
1. Select MANUAL CONTROL and then use the UP and DOWN buttons to scroll to the effect that you want to control. Press ENTER.
2. Use the UP and DOWN buttons to scroll to the DMX value from 000 to
255 that you want to send to that effect. Press ENTER to confirm and send that value.
3. To return to the list of effects, press MENU.
4. If you want to manually control other effects together with the first effect,
repeat steps 1. and 2. and 3. above for the other effects. When you have finished setting effects, return to the previous level of the menu structure, by pressing MENU.
The fixture will continue to show the effects that you have set manually until you set new manual control values for the effects. The effects are unaffected by a power OFF/ON cycle: if you power the fixture off and on again, it will resume showing the effects.
To stop the effects, open the DMX SETUP menu. This will immediately stop all manually controlled effects.
When in manual control mode, pressing any button on the control panel lights up the control panel display and shows the message MANUAL CONTROL MODE.

Focus shortcut

The fixture features a ‘focus shortcut’ mode that lets you adjust the zoom effect. This can be useful if you are setting up multiple fixtures in the rig and want to match the appearance of their projected beams.
To adjust the zoom effect:
1. Hold ENTER for two seconds. Focus shortcut mode is now enabled for
one minute. Light output switches to full white and zoom moves to narrow
2. Use the UP and DOWN buttons to adjust the zoom effect for optimum angle and position.
3. To return to the previous level of the menu structure, press MENU.
4. The fixture will keep its zoom adjustment setting until the next power cycle.
Page 28
28 Martin® ELP PAR IP User Guide

Control / Settings DMX channel

The Control / Settings DMX channel lets you configure certain fixture settings remotely via DMX. It gives access to many of the settings that are available in the control menus (see the ‘Fixture setup’ chapter starting on page 19) and it also gives access to Hibernation Mode (see below).
The control / settings functions require you to hold the required DMX value for a certain number of seconds to implement them (see the DMX protocol section on page 36).

Hibernation mode

Hibernation mode sets light output intensity to zero and disables effect deployment.
The main purpose of this mode is to protect the fixture from the intake of airborne material such as dust and confetti and to provide an option for situations where noise is critical. The small reduction in power consumption obtained in hibernation mode is not the mode’s main purpose.
When you bring the fixture out of hibernation mode, it performs a full reset.
Page 29
Martin® ELP PAR IP User Guide 29

Effects

See the ‘DMX protocol’ section starting on page 36 for a full list of the DMX channels and values required to control the different effects.

Shutter effect

The electronic ‘shutter’ effect provides instant open and blackout, variable speed regular and random strobe.

Dimmer

Overall intensity can be adjusted 0-100% using smooth continuous electronic dimming with 16-bit control resolution.

Custom colors

The fixture offers an RGB color mixing interface with 16-bit resolution in Basic DMX Mode and 8-bit resolution in Compact DMX Mode. Colors are obtained using RGBW LED output.

Color wheel effect

Besides color mixing, Basic DMX Mode features a virtual color wheel effect with 48 preset colors. The virtual color wheel also provides variable speed color scrolling and random colors.
Note that DMX commands sent on the virtual color wheel channel override DMX commands sent on individual RGB color channels. This means that if you want to use RGB color control on DMX channels 4 – 9, the color wheel effect on channel 10 must be set to a DMX value from 0 to 10 (open position).
The virtual color wheel follows the selected calibration mode (see ‘Extended, raw and calibrated modes’ on page 21).

Color Temperature Control

The ELP PAR’s CTC channel lets you vary the color temperature of the fixture’s white output from 1800 K to 12 850 K. The default color temperature
is 6000 K (which corresponds to DMX value 118 on the CTC channel).
If the fixture cannot reach some low CTC values, it clips at the lowest achievable value (for example, DMX values 0-34 all give a color temperature of 1800 K).
Note that CTC is disabled if you put the fixture into raw mode.
Page 30
30 Martin® ELP PAR IP User Guide

Zoom

The Zoom channel lets you vary the angle of the light output continuously from minimum to maximum. 16-bit control is available in Basic and Compact DMX Modes.
Page 31
Martin® ELP PAR IP User Guide 31
RDM
The ELP PAR IP responds to the following RDM PIDs:
PID
Name
Description
GET
SET
0x0001
DISC_UNIQUE_BRANCH
Fixture discovery
N/A
N/A
0x0002
DISC_MUTE
Fixture discovery
N/A
N/A
0x0003
DISC_UN_MUTE
Fixture discovery
N/A
N/A
0x0020
QUEUED_MESSAGE
Get Queued Messages
Y
0x0030
STATUS_MESSAGES
Get Status/Error Information
Y
0x0031
STATUS_ID_DESCRIPTION
Status/Error Description
Y
0x0032
CLEAR_STATUS_ID
Clear Status/Error Queue
Y 0x0050
SUPPORTED_PARAMETERS
Parameter discovery
Y
0x0051
PARAMETER_DESCRIPTION
Parameter discovery
Y
0x0060
DEVICE_INFO
Get basic info
Y 0x0080
DEVICE_MODEL_DESCRIPTION
Product Name
Y
0x0081
MANUFACTURER_LABEL
Manufacturer Name
Y
0x0082
DEVICE_LABEL
User-Changeable Label
Y Y 0x0090
FACTORY_DEFAULTS
Reset to factory defaults
Y
Y
0x00C0
SOFTWARE_VERSION_LABEL
Firmware version
Y
0x00E0
DMX_PERSONALITY
DMX Mode
Y Y 0x00E1
DMX_PERSONALITY_DESCRIPTION
DMX Mode Name
Y
0x00F0
DMX_START_ADDRESS
DMX Start Address
Y
Y
0x0121
SLOT_DESCRIPTION
DMX Channel Description
Y 0x0200
SENSOR_DEFINITION
Sensor Description
Y
0x0201
SENSOR_VALUE
Sensor Value
Y
Y
0x0400
DEVICE_HOURS
Fixture Hours
Y Y 0x0405
DEVICE_POWER_CYCLES
Fixture Power Cycles
Y
Y
0x0500
DISPLAY_INVERT
Flip Display
Y
Y
0x0501
DISPLAY_LEVEL
Display Intensity
Y Y 0x1000
IDENTIFY_DEVICE
Highlight Fixture in rig
Y
Y
0x1001
RESET_DEVICE
Warm/Cold Reset
Y
0x1020
PERFORM_SELFTEST
Selftest
Y
Y
Page 32
32 Martin® ELP PAR IP User Guide
0x1021
SELF_TEST_DESCRIPTION
Selftest Description
Y
0x8001
DMX_RESET
Enable/Disable Fixt. Off via DMX
Y
Y
0x8003
FIXTURE_ID
User-Changeable Fixture Number
Y
Y
0x8004
COLOR_MODE
Set Color Mode
Y Y 0x8301
EFFECT_SPEED
Set Effects Speed
Y
Y
0x8308
DISPLAY_ERRORS_ENABLE
Show Errors on Display
Y
Y
0x8310
DIMMER_CURVE
Set Dimmer Curve
Y Y 0x8312
DISPLAY_AUTO_OFF
Display Auto Off
Y
Y
0x8329
HIBERNATION_MODE
Enable/Disable Hibernation
Y Y 0x832A
TUNGSTEN_MODE
Enable/Disable Tungsten Mode
Y
Y
0x8603
FAN_CLEAN
Fan Clean Mode
Y
Y
0x8604
FAN_MODE
Fan Mode
Y
Y
0x8700
SERIAL_NUMBER
Read Serial Number
Y
Page 33
Martin® ELP PAR IP User Guide 33

Maintenance

Read ‘Safety information’ on page 4 before servicing the fixture.
Refer any service operation not described in this user manual to a qualified service technician.
Disconnect the fixture from mains power and allow to cool completely before cleaning or servicing.
Service fixtures in an area where there is no risk of injury from falling parts, tools or other materials.

Cleaning

Excessive dust, smoke fluid, and particle buildup degrades performance, causes overheating and will damage the fixture. Damage caused by inadequate cleaning or maintenance is not covered by the product warranty.
The cleaning of external optical lenses must be carried out periodically to optimize light output. Cleaning schedules for lighting fixtures vary greatly depending on the operating environment. It is therefore impossible to specify precise cleaning intervals for the fixture. Environmental factors that may result in a need for frequent cleaning include:
Use of smoke or fog machines.
High airflow rates (near air conditioning vents, for example).
Presence of cigarette smoke.
Airborne dust (from stage effects, building structures and fittings or the
natural environment at outdoor events, for example).
If one or more of these factors is present, inspect fixtures within their first 100 hours of operation to see whether cleaning is necessary. Check again at frequent intervals. This procedure will allow you to assess cleaning requirements in your particular situation. If in doubt, consult your Martin dealer about a suitable maintenance schedule.
Use gentle pressure only when cleaning, and work in a clean, well-lit area. Do not use any product that contains solvents or abrasives, as these can cause surface damage.
To clean the fixture:
1. Disconnect the fixture from power and allow it to cool for at least 15 minutes.
Page 34
34 Martin® ELP PAR IP User Guide
2. Vacuum or gently blow away dust and loose particles from the outside of
the fixture and the air vents with low-pressure compressed air. Holding cooling fan blades stationary with a screwdriver will protect them from spinning too fast and possibly being damaged when you apply a vacuum or air jet.
3. Clean lenses by wiping gently with a soft, clean lint-free cloth moistened
with a weak detergent solution. Do not rub the surface hard: lift particles off with a soft repeated press. Dry with a soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water.
4. Clean the pressure equalization valve on the back of the fixture by
brushing gently with a soft brush. If the valve appears to be blocked, contact a Martin Service agent for replacement.
5. Check that the fixture is dry before reapplying power.

Uploading new firmware

Important! Do not switch the fixture off or disconnect the source of the
firmware during an update, or the firmware will be corrupted. You can check the currently installed firmware version in the INFORMATION
menu. Firmware updates can be downloaded automatically from the Martin cloud using the Martin Companion software suite on a PC connected to the Internet.
Fixture information and settings are not affected when you upload new firmware to the fixture. All ELP PAR IP fixtures that are powered on and connected via a DMX link to the fixture that you update will also have their firmware updated.
If you update firmware to a newer version, check the ELP PAR IP area of www.martin.com to see whether an updated version of this User Guide is available for the new firmware.
You need the following in order to install firmware:
A Windows PC running the latest version of the Martin Companion
software suite that is available for download from the Martin website at www.martin.com.
The latest ELP PAR IP firmware files (Martin Companion automatically
downloads these from the Martin fixture firmware cloud when you run it on a PC that is connected to the Internet).
A Martin Companion Cable USB-DMX hardware interface (see “Accessories” on page 49). Note that you can install new firmware in multiple fixtures at the same time using the Martin Companion Cable.
Page 35
Martin® ELP PAR IP User Guide 35
To install the ELP PAR IP firmware using a Martin Companion Cable:
1. Apply power to the ELP PAR IP fixture(s) and allow it to boot.
2. Connect the Martin Companion Cable’s USB connector to a USB port on
your PC. Connect the Martin Companion Cable’s XLR connector to either the fixture’s DMX IN connector or the DMX link.
3. Start the PC and launch Martin Companion. Check that the Martin
Companion application correctly detects the Martin Companion Cable (a green dot should appear next to USB Connected in the top right-hand corner of the window).
4. Locate the latest ELP PAR IP firmware in Martin Companion (FirmwareELPELP PAR IP).
5. Start the firmware update by clicking Update Firmware in Martin Companion. Do not disconnect the Martin Companion Cable or power off the fixture(s) until the upload is complete and the fixture(s) has successfully rebooted.
6. If you are updating multiple fixtures over a DMX link, check that they have all rebooted correctly.

Service and repairs

There are no user-serviceable parts inside the fixture. Do not open the housing. The LED light source is not user-replaceable.
Refer any service or repair operation not described in this manual to an authorized Martin service technician. Do not try to carry out such an operation yourself, as doing so may present a health or safety risk. It may also cause damage or malfunction, and it may void your product warranty.
Installation, on-site service and maintenance can be provided worldwide by the Martin Professional Global Service organization and its approved
agents, giving owners access to Martin’s expertise and product knowledge
in a partnership that will ensure the highest level of performance throughout the product’s lifetime. Please contact your Martin supplier for details.
Page 36
36 Martin® ELP PAR IP User Guide

DMX protocol – Basic Mode (default)

DMX footprint: 14 channels

Channel
Value
Function
Fade
type
De-
fault
1
0-19
20-49
50-200 201-210 211-255
Strobe and shutter effects
Shutter closed Shutter open Strobe, slow fast Shutter open Random strobe, slow fast
Snap
30
2
0-65535
Dimming coarse 0100%
Fade
0
3
Dimming fine
4
0-65535
Red coarse 0100%
Fade
0
5
Red fine
6
0-65535
Green coarse 0100%
Fade
0
7
Green fine
8
0-65535
Blue coarse 0100%
Fade
0
9
Blue fine
10
0-34
118
128
255
CTC 1800 K 6000 K 6500 K 12 850 K
Fade
118
11
0-10 11-12 13-14 15-16 17-18 19-20 21-22 23-24 25-26 27-28 29-30 31-32 33-34
Color wheel effect (color presets)
Open (white) Moroccan Pink (LEE 790) Pink (LEE 157) Special Rose Pink (LEE 332) Follies Pink (LEE 328) Fuchsia Pink (LEE 345) Surprise Pink (LEE 194) Congo Blue (LEE 181) Tokyo Blue (LEE 071) Deep Blue (LEE 120) Just Blue (LEE 079) Medium Blue (LEE 132)
Snap
0
Page 37
Martin® ELP PAR IP User Guide 37
Channel
Value
Function
Fade
type
De-
fault
11
(contd.)
35-36 37-38 39-40 41-42 43-44 45-46 47-48 49-50 51-52 53-54 55-56 57-58 59-60 61-62 63-64 65-66 67-68 69-70 71-72 73-74 75-76 77-78 79-80 81-82 83-84 85-86 87-88 89-90 91-92 93-94 95-96 97-98
99-100 101-102 103-104 105-106
107 - 190 191 - 214
215 - 219 220 - 243
Double CT Blue (LEE 200) Slate Blue (LEE 161) Full CT Blue (LEE 201) Half CT Blue (LEE 202) Steel Blue (LEE 117) Lighter Blue (LEE 353) Light Blue (LEE 118) Medium Blue Green (LEE 116) Dark Green (LEE 124) Primary Green (LEE 139) Moss Green (LEE 089) Fern Green (LEE 122) Jas Green (LEE 738) Lime Green (LEE 088) Spring Yellow (LEE 100) Deep Amber (LEE 104) Chrome Orange (LEE 179) Orange (LEE 105) Gold Amber (LEE 021) Millennium Gold (LEE 778) Deep Golden Amber (LEE 135) Flame Red (LEE 164) Red Magenta (LEE 113) Medium Lavender (LEE 343) Pure White (White LEDs only) Pure Red (Red LEDs only) Pure Yellow (Red+Green LEDs only) Pure Green (Green LEDs only) Pure Cyan (Green+Blue LEDs only) Pure Blue (Blue LEDs only) Pure Magenta (Blue+Red LEDs only) Peacock Blue (LEE 115) Dark Lavender (LEE 180) Double CT Orange (LEE 287) Full CT Orange (LEE 204) Half CT Orange (LEE 205) Deep Straw (LEE 015)
No function
Continuous rotation (color scroll) Ascending, fast slow Stop (at current position) Descending, slow fast
Page 38
38 Martin® ELP PAR IP User Guide
Channel
Value
Function
Fade
type
De-
fault
11
(contd.)
244 - 247 248 - 251 252 - 255
Random colors Random color, fast Random color, medium Random color, slow
Snap
0
12
0-65535
Zoom narrow wide coarse 0100%
Fade
32768
13
Zoom narrow wide fine
14
0 - 9 10 - 14 15 - 16
17
18-22
23 24 25 26
27 - 30
31 32
33 - 37
38 39 40
41 - 51
52 53 54
55 56
57 - 60
61 62
63 - 71
72 73 74 75 76
77 - 99
Control / Settings
No function (disables calibration) – 5 s. Reset fixture – 5 s.
No function
Reset beam – 5 s.
No function
Linear dimming curve – 1 s. Square law dimming curve 1 s. Inverse square law dimming curve –1 s. S-curve dimming curve – 1 s.
No function
Dimming speed = Fast 1 s. Dimming speed = Slow – 1 s.
No function
Extended color mode 1 s. Calibrated color mode – 1 s. Raw color mode –1 s.
No function
Display ON –1 s. Display OFF –1 s. Regulated fan speed, fixed intensity – 1 s. Full fan speed, regulated intensity – 1 s. Theater mode: reduced max. intensity, low fan speed – 1 s.
No function
Hibernation mode = ON – 5 s.
Hibernation mode = OFF – 5 s.
No function
Tungsten emulation = ON – 1 s.
Tungsten emulation = OFF – 1 s.
Scene catch record – 5 s. Scene catch playback = ON – 5 s. Scene catch playback = OFF – 5 s.
No function
Snap
0
Page 39
Martin® ELP PAR IP User Guide 39
Channel
Value
Function
Fade
type
De-
fault
100 101 102
103 - 113
114
115 - 198
199
200 - 255
Enable calibration – 5 s.
No function
Store dimmer calibration – 5 s.
No function
Store zoom calibration – 5 s.
No function
Reset ALL calibration settings to factory defaults – 5 s.
No function
Page 40
40 Martin® ELP PAR IP User Guide

DMX protocol – Compact Mode

DMX footprint: 9 channels

Channel
Value
Function
Fade
type
De-
fault
1
0-19
20-49
50-200
201-210 211-255
Strobe and shutter effects
Shutter closed Shutter open Strobe, slow fast Shutter open Random strobe, slow fast
Snap
30
2
0-65535
Dimming coarse 0 100%
Fade
0
3
Dimming fine
4
0-255
Red 0 100%
Fade 0 5
0-255
Green 0 100%
Fade 0 6
0-255
Blue 0 100%
Fade
0
7
0-34
118
128
255
CTC 1800 K 6000 K 6500 K 12 850 K
Fade
118
8
0-65535
Zoom narrow wide coarse 0100%
Fade
32768
9
Zoom narrow wide fine
Page 41
Martin® ELP PAR IP User Guide 41

Control menus

To access the control menus, press the MENU button. Use the UP and DOWN buttons to navigate the menus. Select any required menu option using the ENTER button. For more information, see Using the control menus on page 19.
Default fixture settings are shown in bold.
Menu
Setting/value
Notes
DMX SETUP
DMX ADDRESS
001499
Set fixture’s DMX address
DMX CONTROL MODE
COMPACT
Set DMX control mode BASIC
PERSONALITY
TUNGSTEN EMULATOR
ON
Activate tungsten incandescent lamp emulation mode
OFF
COLOR MODE
EXTENDED COLOR
Calibrated white, uncalibrated color
CALIBRATED
Calibrated white, calibrated color
RAW UNCALIBRATED
Raw: uncalibrated white, uncalibrated color
DIMMER CURVE
LINEAR
Dimming curve options SQUARE LAW
INV SQ LAW
S-CURVE
DIMMING SPEED
FAST
Optimize dimmer for speed
SLOW
Optimize dimmer for smoothness
NO DATA MODE BLACKOUT
Set fixture behavior if DMX signal stops: blackout or hold current effect
HOLD
Page 42
42 Martin® ELP PAR IP User Guide
SCENE CATCH
SCENE CATCH RECORD
Saves all current DMX values as playback scene
SCENE CATCH ON
Sets fixture to run currently saved playback scene after power cycle or reset. Any new DMX input disables scene playback until next power cycle.
SCENE CATCH OFF
Disables playback scene functionality
COOLING MODE
REGULATED FANS
Fans normal temp.-regulated
THEATER MODE
Fans low-noise temp. regulated (reduced max. output)
FULL
Fans constant full speed
DISPLAY
DISPLAY ROTATION
NORMAL
Normal orientation
ROTATE 180°
Inverted orientation
DISPLAY INTENSITY
10 - 100
Control panel display intensity in %
TEMPERATURE UNIT
°C
All temperature readouts in Celsius
°F
All temperature readouts in Fahrenheit
DEFAULT SETTINGS
FACTORY DEFAULT
NO
Return all fixture settings except calibration to factory defaults
YES
FIXTURE TEST
TEST ALL
Automatic test of all effects including dimming
TEST DIMMER
DIMMER
Automatic test of all effects
TEST EFFECTS
RED
Manually test individual effects. Use UP & DOWN to scroll through effects and pause test, press ENTER to start test. Press MENU to exit test.
COLOR = Virtual color wheel
GREEN
BLUE
CTC
COLOR
ZOOM
Page 43
Martin® ELP PAR IP User Guide 43
INFORMATION
POWER ON TIME
xxxxH
Display hours fixture powered on since manufacture
LED HOURS
xxxxH
Display hours LEDs powered on since manufacture
SW VERSION
Vx.x.x
Display currently installed firmware version
FIXTURE ID
0 - 9999
Display a user-settable 4-digit fixture ID number
RDM UID
xxxxxxxxxxxx
Display the fixture’s unique RDM
ID number
TEMPERATURES
LED / PSU
Display temperatures of all PCBs and the integrated PSU
FAN SPEED
LED / PSU
Display speeds in RPM of all cooling fans including the PSU cooling fan
DMX LIVE
STROBE
0 - 255
Scroll to display DMX values currently being received on each DMX channel from Strobe channel to Control / Settings channel
DIMMER
0 - 255
DIMMER FINE
0 - 255
ZOOM FINE
0 - 255
FUNCTION
0 - 255
MANUAL CONTROL
RESET ALL
NO
Reset entire fixture
YES
EFFECTS
NO
Reset effects only YES
STROBE
0 - 255
Manually send DMX values on each channel from Strobe channel to Zoom fine control channel
DIMMER
0 - 255
DIMMER FINE
0 - 255
ZOOM FINE
0 - 255
Page 44
44 Martin® ELP PAR IP User Guide
SERVICE
CALIBRATION
DIMMER
0 - 255
Calibrate overall dimming and RGB colors
RED
0 - 255
GREEN
0 - 255
BLUE
0 - 255
CTC
0 - 255
Adjust 6000 K center point
CTC Tint
0 - 255
Adjust green/ magenta tint
RAW CTC
0 - 255
Adjust 6000 K center point
RAW CTC Tint
0 - 255
Adjust green/ magenta tint
ZOOM
-128 - 127
Calibrate zoom
LOAD DEFAULTS
LOAD
Load the factory default calibration settings
SAVE
Save current custom calibration settings.
Important! See note below
SAVE SETTING
SAVE
Replace factory default calibration settings with custom values or zero values.
Important! See note below
CLEAR ALL VALUES
RESTORE
Reset all calibration values to zero.
Important! See note below
Important note
LOAD DEFAULTS → SAVE stores any custom calibration values that
you have created in the CALIBRATION menu. The fixture will keep using these values even when the fixture power is cycled off and on.
LOAD DEFAULTS → LOAD loads the original factory default calibration values (unless these have been overwritten or erased – see below)
Page 45
Martin® ELP PAR IP User Guide 45
CLEAR ALL VALUES → RESTORE erases all calibration settings – both
custom settings and the original factory settings. Important! If you use
this command you will need to fully recalibrate the fixture.
Important! SAVE SETTING → SAVE permanently overwrites the
original factory settings with either the custom settings created using LOAD DEFAULTS → SAVE or the zero values created using CLEAR ALL VALUES → RESTORE. The SAVE SETTING → SAVE
command should normally be used by Martin Service only!
Page 46
46 Martin® ELP PAR IP User Guide

Troubleshooting

This section describes a few common problems that may occur during operation and provides some suggestions for easy troubleshooting:
Symptom
Potential cause
Remedies
No light from fixture or fans not working.
Power supply issue such as faulty connector, damaged cable or internal fault.
Ensure that the mains supply is connected and supplying power to the fixture. Check all power connections and cables.
Contact your Martin authorized distributor or service center for assistance.
One of the control channels is unresponsive or only responds intermittently.
DMX setup or DMX link fault.
Faulty cable connection.
Damaged zoom step motor.
See next section.
Contact your Martin authorized distributor or service center for assistance.
Fixture does not respond to DMX control.
Incorrect DMX addressing.
Fault on DMX link due to damaged connector or cable, or potential interference from proximity to a high­voltage installation.
Ensure that fixture’s DMX
address matches address set on DMX control device.
Check all DMX cables and connections.
Ensure that DMX link is terminated.
Check that all components on DMX link use standard DMX polarity.
Attempt to control the fixture with another DMX control device.
Move or shield link if it is close to an unshielded high-voltage installation.
Page 47
Martin® ELP PAR IP User Guide 47

Specifications

Physical

Dimensions incl. bracket (LxWxH) ... 315x285x398 mm (12.4x11.3x15.7 in.)
Weight ................................................................................. 9.1 kg (20.1 lbs.)

Dynamic Effects

Color mixing ....................................................................................... RGBW
Color presets ............................. 48 color presets, virtual color wheel effects
Color temperature ................................................. Variable 1800 – 12 850 K
Electronic dimming ............................ 0 - 100%, four dimming curve options
Strobe and pulse effects ............ Variable speed and action, random strobe
Electronic 'shutter' effect ...................................... Instant open and blackout
Zoom .............................................................................................. Motorized

Control and Programming

Control options ............................................................................ DMX, RDM
DMX channels ................... 14 (Basic DMX Mode), 9 (Compact DMX Mode)
16-bit fine control ............................. Dimming, RGB (in Basic Mode), Zoom
LED color management modes ..................... Raw, extended and calibrated
DMX address setting ................................ Control panel with OLED display
DMX compliance .............................................................. USITT DMX512-A
RDM compliance ............................................................. ANSI/ESTA E1.20

Optics

Light source .................................................. 7 x 40 W RGBW Osram LEDs
Minimum LED lifetime .................. 50 000 hours (to >70% luminous output)*
Maximum output ....................................................................... 3300 lumens
Beam angle (half-peak) ............................................................... 4.4 – 33.3°
Field angle (one-tenth peak) ....................................................... .5.5 – 50.0°
*Figure obtained under manufacturer´s test conditions

Construction

Filter mount ...................................... PAR 46 – 191 x 191 mm (7.5 x 7.5 in.)
Color ..................................................................................................... Black
Housing ................................................................. Aluminum and composite
Ingress protection rating ........................................................................ IP65

Installation

Mounting points..................................... Adjustable bracket, surface or truss
mount (fits Martin Omega Bracket)
Location ........ Wet locations, temporary outdoor use, not for household use
Orientation .............................................................................................. Any
Minimum distance to illuminated surfaces .................................. 1 m (3.3 ft.)
Minimum distance to combustible material .............................. 0.5 m (1.7 ft.)
Minimum clearance around fans and vents ............................. 0.5 m (1.7 ft.)
Page 48
48 Martin® ELP PAR IP User Guide

Connections

AC power in and thru ................................. Neutrik powerCON TRUE1 TOP
DMX data in and thru .............................. Neutrik IP-rated 5-pin locking XLR

Electrical

AC power ........................................................ 100-240 V nominal, 50/60 Hz
Typical power consumption ................................................................ 300 W
Maximum half-cycle RMS inrush current ............................................ 11.2 A
Power supply unit ................................ Auto-ranging electronic switch mode

Maximum power and current

100-120 V, 60 Hz ....................................... 3.7 A, 330 W, Power factor 0.99
220-240 V, 50 Hz ....................................... 1.7 A, 330 W, Power factor 0.94
*Measurements made at nominal voltage with all LEDs at full intensity. Allow for a deviation of +/- 10%.

Thermal

Maximum surface temperature .............................................. 73° C (164° F)
Cooling .................................. Forced air (temperature regulated, low noise)
Maximum ambient temperature (Ta max.)............................. 40° C (104° F)
Minimum ambient temperature (Ta min).................................. -10°C (14° F)
Total heat dissipation* ............................................................. 1126 BTU/hr.
*Calculated, +/- 10%, at full intensity, full white

Approvals

Global CB Certification/IECEE ..................... IEC 60598-2-17 (IEC 60598-1)
EU safety ................... EN 60598-2-17 (EN 60598-1), EN 62471, EN 62493
EU EMC ........................... EN 55015, EN 55032, EN 55035, EN 61000-3-2,
EN 61000-3-3, EN 61547
US safety ......................................................................................... UL 1573
US EMC ....................................................................... FCC Part 15 Class B
Canadian safety ............................................................. CSA C22.2 No. 166
Canadian EMC .................................. ICES-003 Class B, ICES-005 Class B
Australia/NZ .......................................................................................... RCM
United Kingdom .................................................................................. UKCA

Environmental

RoHS ............................................................................................ Compliant
REACH ......................................................................................... Compliant
Page 49
Martin® ELP PAR IP User Guide 49
WEEE ........................................................................................... Compliant
Proposition 65 ............................................................................... Compliant
Efficacy (max. output) ................................................................... 14.3 lm/W
LWR* ............................................................................ 385 lm/kg (174 lm/lb)
*LWR = Lumen-to-Weight Ratio

Included Items

Adjustable mounting bracket

Accessories

Power input cables, 16 A

Power Input Cable, H07RN-F, 2.5 mm2, bare ends to
TRUE1 NAC3FX-W TOP (female), 1.5 m (4.9 ft.) ................. P/N 91611797
Power Input Cable, SJOOW, 12 AWG, bare ends to
TRUE1 NAC3FX-W TOP (female), 1.5 m (4.9 ft.) ................. P/N 91610173

Power relay cables, 16 A, for relaying power to fixtures in chains

Power Relay Cable, H07RN-F, 2.5 mm2,
TRUE1 to TRUE1, 2.5 m (8.2 ft.) ........................................... P/N 91611796
Power Relay Cable, SJOOW, 12 AWG,
TRUE1 to TRUE1, 2.5 m (8.2 ft.) ........................................... P/N 91610172

Power connectors

Cable Connector, Neutrik powerCON TRUE1
NAC3FX-W TOP (female) ............................................... P/N 91611789HU
Cable Connector, Neutrik powerCON TRUE1
NAC3MX-W TOP (male) ................................................... P/N 91611788HU

Installation hardware

Martin Omega bracket for rigging clamp attachment............. P/N 91602001
Half-coupler clamp ................................................................. P/N 91602005
G-clamp (suspension vertically downwards only) .................. P/N 91602003
Quick-trigger clamp (suspension vertically downwards only) P/N 91602007
Safety Cable, SWL 60 kg, BGV C1 / DGUV 17, black .......... P/N 91604006
Safety Cable, SWL 60 kg, BGV C1 / DGUV 17, silver .......... P/N 91604007

Related Items

Martin Companion software
suite (incl. firmware uploader) ............ Free download from www.martin.com
Martin Companion Cable
USB/DMX hardware interface ................................................ P/N 91616091

Ordering Information

ELP PAR IP in cardboard box ...................................... P/N MAR-90800010
Specifications are subject to change without notice. For the latest product specifications, see www.martin.com
Page 50
50 Martin® ELP PAR IP User Guide

Supplier’s Declaration of Conformity

Harman Professional, Inc. have issued an FCC Supplier’s Declaration of Conformity for this product. The Declaration of Conformity is available for download from the ELP PAR IP area of the Martin website at www.martin.com

FCC compliance statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Disposing of this product Martin® products are supplied in compliance with Directive 2012/19/EC of the European Parliament and of the Council of the European Union on WEEE (Waste Electrical and Electronic Equipment), where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of Martin products
Page 51
Page 52
www.martin.com
Loading...