Martin Cyclo 03 Directional User Manual

Page 1
martinarchitectural
Cyclo 03 Directional
user manual
Page 2
Dimensions
Measurements are in millimeters
1135
218
285
107
1100
1200
250°
50°
50°
50°
50°
All rights reserved. No part of this manual may be reproduced, in any form or by any means, with-
out permission in writing from Martin Professional A/S, Denmark.
© 2004 Martin Professional A/S, Denmark.
Printed in Denmark.
Page 3
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Data linking multiple luminaires. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Burning in fluorescent tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Stand-alone operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Stand-alone operation settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Single stand-alone operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Master/slave stand-alone operation . . . . . . . . . . . . . . . . . . . . . . . . . 16
DMX controlled operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Connecting a DMX control device. . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Setting a luminaire to DMX operation . . . . . . . . . . . . . . . . . . . . . . . . 21
Controlling via DMX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Fluorescent tube replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
DMX protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Cyclo 03 Directional Specifications . . . . . . . . . . . . . . . . . . . 31
Page 4
Page 5
Introduction
Thank you for selecting the Martin Cyclo 03 Directional. The Cyclo 03 Directional is a dynamic fluorescent color changing luminaire that can be programmed for stand-alone operation or controlled via DMX.
The Cyclo 03 Directional is designed for dynamic color illumination of walls and surfaces. A patented optical system ensures effective color mixing within the main reflector, allowing the luminaire to be positioned close to the illuminated surface without color hot-spots. Dimmable T5 fluorescent tubes combine high efficiency, bright color and long lamp life.
The Cyclo 03 Directional can be surface-mounted or mounted on standard 3-phase lighting track. It can be tilted through 250°, allowing flexibility of installation.
Control cables are through-wired for easy installation.
The Cyclo 03 Directional features:
• Controllable RGB color-mixing
• Full 0-100% intensity control of the red, green and blue tubes
• High output, long life T5 fluorescent tubes
• Flexible mounting options
• 250° of tilt
Important! Read this manual before attempting to install this product.
The most recent version of this user manual is available from the Support area of the Martin Architectural website at http://www.martin­architectural.com
Safety information
Warning! This product is for professional use only. It is not for household
use.
These products present risks of lethal or severe injury due to fire and heat, electric shock and falls. Read this manual before powering or installing these luminaires, follow the safety precautions listed below and observe all warnings in this manual and on the luminaires. If you have questions about
Introduction 5
Page 6
how to operate these luminaires safely, please contact your Martin dealer or call the Martin 24-hour service hotline at +45 70 200 201.
Protection from electric shock
• Disconnect the luminaire from AC power before removing or installing a tube or any part, and when not in use.
• Always ground (earth) the luminaire electrically.
• Use only a source of AC power that complies with local building and electrical codes and has both overload and ground (earth) fault protection.
• Ensure that the luminaire’s live and neutral conductors are both connected to the same RCD (ground fault circuit-breaker)
• Do not expose the luminaires to rain or moisture.
• Refer all service to a Martin service technician.
Protection from burns and fire
• Provide a minimum clearance of 0.1 meters (4 inches) around the luminaire.
• Do not modify the luminaire or install other than genuine Martin parts.
• Do not operate the luminaire if the ambient temperature (Ta) exceeds 40° C (104° F).
Protection from injury due to falls
• Ensure that all components and installation fittings are securely fastened.
• Ensure that all supporting structures, surfaces and fasteners can bear the weight of all luminaires installed.
• Block access below the work area whenever installing, servicing or removing the luminaire.
6 Cyclo 03 Directional user manual
Page 7
Installation
This section describes in general terms how to install the luminaire, connect it to AC power and connect control data cables. These procedures must be performed by qualified professionals.
Mounting
The Cyclo 03 Directional features two mounting options:
• track-mounting on standard 3-phase lighting track
• surface-mounting using mounting brackets that are available as accessories.
Warning! Check that all fasteners, structures and surfaces used to mount
the Cyclo 03 Directional can bear the total weight of all devices installed.
Work from a stable platform and block access below the work area when installing or servicing luminaires above head-height.
Lighting track mounting
The Cyclo 03 Directional can be mounted on lighting track from all major manufacturers (Nokia, Erco, Zumtobel, iGuzzini, Nordic Aluminium, etc.)
3mm
Installation 7
Page 8
A 3mm Allen key is required for this operation.
To mount a Cyclo 03 Directional on lighting track:
1. Isolate the lighting track from the power supply and ensure that power cannot be reapplied, even accidentally.
2. Hold the luminaire up to the lighting track and slide the ends of the mounting arms into the slot in the track.
3. Supporting the luminaire in position, fully tighten the 3mm Allen screws in the side of each mounting arm.
4. Check that the luminaire is held firmly in place before reapplying power.
Lighting track dimensions can vary slightly between manufacturers. If the Cyclo 03 Directional is not held firmly in place, you may need to repeat the above procedure, adding the square spacers supplied with the luminaire to take up any clearance between the mounting arms and the lighting track.
8 Cyclo 03 Directional user manual
Page 9
Surface mounting
The Cyclo 03 Directional can be surface-mounted on a floor, wall or ceiling using a bracket kit that is available as an accessory.
To surface-mount the Cyclo 03 Directional:
1. Ensure that the surface on which you want to mount the Cyclo 03 Directional can support the weight of all the luminaires installed on it.
2. Mark up two points 1100mm (43.3 in.) apart as center points for the mounting brackets. Allow enough space around the center points for the 110mm (4.3 in.) square cover plates
1100
Ø5.5
80
80
3. Hold each mounting bracket against the mounting surface so that the raised ridge in the bracket runs at 90° to the long side of the Cyclo 03 Directional (see illustrations), and so that the center point you have marked is visible in the middle of the rectangular hole in the center of the bracket.
4. Mark the mounting surface using the holes at the corners of each bracket as guides, and drill holes in the mounting surface for the fasteners.
5. Fasten the mounting brackets to the surface using eight high-tensile (grade 8.8 or over) M5 fasteners (screws, masonry bolts, etc.). Note that the ridge in the bracket must be at 90° to the long side of the luminaire.
110
COVERBRACKET
110
Installation 9
Page 10
6. Clip the bracket covers over the brackets with the long side of the rectangular hole at 90% to the.Cyclo 03 Directional.
7. Hold the luminaire up to the mounting brackets. Slide the ends of the mounting arms through the rectangular holes in the bracket covers and into the mounting brackets.
8. Carefully supporting the luminaire, fully tighten the 3mm Allen screws in the side of each mounting arm.
9. Check that the luminaire is totally secure.
AC power
It is the installer’s responsibility to ensure that all local safety regulations and legal requirements are observed when installing and connecting the Cyclo 03 Directional.
AC mains power compatibility and consumption data are given in the Specifications section on page 31.
Warning! Many installations use common neutral conductors in branch
circuit distribution boxes. The neutral lead in the cable must be connected to the same RCD (ground fault circuit breaker) as the live lead in the cable. If it is not, users are left unprotected from the risk of potentially lethal electric shock. It is the installer’s responsibility to ensure that the Cyclo 03 Directional’s neutral conductor is connected to the same RCD as the live conductor.
Important! Cyclo 03 Directional luminaires incorporate four electronic
ballasts that “leak” a total current of between 0.8mA and 4mA to ground (earth). Luminaires must be correctly connected to ground so that this “leakage” current can be absorbed.
It is also important that installation is carried out correctly in order to avoid unintentional tripping of the RCD (ground fault circuit breaker). Because of the “leakage” current, we recommend connecting a maximum of seven Cyclo 03 Directional luminaires per phase when circuits are protected by a 30mA RCD. Bear in mind that some RCDs rated at 30mA may trip when current leakage to ground is as low as 20mA.
Connecting to mains power
Cyclo 03 Directional luminaires have an ENSTO male connector built into the casing for mains power input. A female ENSTO connector is supplied with the luminaire for installation on the power supply cable.
10 Cyclo 03 Directional user manual
Page 11
To draw power from lighting track, a suitable power take-off plug from the lighting track supplier must be installed on the power supply cable in accordance with the lighting track supplier’s instructions.
Some common color-coding systems for mains wiring is given below:
Wire (EU) Wire (US) Pin Marking
brown black live “L” or “1”
blue white neutral “N”
yellow/green green ground
When installing the female ENSTO connector on the power cable, note the markings next to the screw terminals:
• The terminal marked 1 must be connected
to the live wire.
• The centre terminal marked must be connected to the ground (earth) wire.
• The terminal marked
N must be connected
the neutral wire.
The following connectors and cables are available from your Martin dealer:
ENSTO 3-pole 16A/250V male connector . . . . . . . . . . . P/N 05347202
ENSTO 3-pole 16A/250V female connector . . . . . . . . . . P/N 05327202
ENSTO male/female cable (15 cm/5.9in.). . . . . . . . . . . . .P/N 11501019
Installation 11
Page 12
Data linking multiple luminaires
You need to create a serial data link to:
• Operate two or more Cyclo 03 Directionals in master/slave stand-alone mode, where all luminaires run a synchronized light show without a separate DMX control device
• Control luminaires with a DMX control device.
A reliable data connection requires suitable cable. CAT 5 (category 5) UTP (unshielded twisted pair) network cable is suitable for this purpose. Your Martin Architectural dealer can advise and supply suitable cable.
Luminaires on a serial data link must be daisy-chained in one single line, maximum 500 meters (1640 ft.) long, with maximum 32 luminaires. To exceed 32 luminaires or 500 meters, or to add branches, an optically isolated amplifier-splitter such as the Martin RS-485 Opto-Splitter (P/N
90758060) must be used.
Data cable can be connected to the Cyclo 03 Directional via RJ-45 sockets that are wired as follows:
• pins 7 & 8 to ground (earth)
• pin 2 to signal - (cold)
• pin 1 to signal + (hot).
DMX controller
Termination plug
Master
Slave
Slave
Termination plug
DMX control link
12 Cyclo 03 Directional user manual
Master/slave link
Page 13
To create the data link:
1. Use suitable cable to connect one of the RJ-45 sockets on the first Cyclo 03 Directional to an RJ-45 socket on the next luminaire.
2. Continue connecting up to 32 luminaires using the RJ-45 sockets.
3. Terminate the link by inserting a an RJ-45 DMX termination plug (P/N
91613028) in the RJ-45 data output of the last luminaire.
4. If using a DMX control device, use suitable cable to connect the device’s DMX output to one of the RJ-45 sockets on the first Cyclo 03 Directional.
TIp! Random “flicker” and other unexplained control problems
during stand-alone master/slave operation can often be cured by inserting an RJ-45 DMX termination plug into the unused socket of the first luminaire.
Burning in fluorescent tubes
Optimum tube performance is obtained after burning in new fluorescent tubes for 100 hours at full power.
Installation 13
Page 14
Stand-alone operation
In stand-alone operation, the Cyclo 03 Directional can be used without a DMX controller. Static single colors or two-color mixes can be displayed, or luminaires can be programmed to change colors in cycles. Changes can be programmed at 1, 5, 10 or 30 second intervals.
Two stand-alone operation modes are available:
•In single stand-alone operation, luminaires run independently of each other. No data link is required.
•In master/slave stand-alone operation, luminaires must be linked. Synchronized action in all luminaires is triggered by one “master” luminaire.
In both single and master/slave stand-alone operation, luminaires are programmed via the pins on the DIP switch on the luminaire’s housing as shown in Table 1.
Pin Function
1 Red active 2 Green active 3 Blue active 4 Not used 5 & 6 Program speed
Pin 6 Pin 5 Speed
OFF OFF 1 sec. steps (fastest setting) OFF ON 5 sec. steps ON OFF 10 sec. steps
ON ON 30 sec. steps (slowest setting) 7 OFF = Blackout fading, ON = Crossfading 8 OFF = Run program, ON = Pause program 9 OFF = Master, ON = Slave (Note: do not set more than one luminaire as master) 10 ON = Stand-alone mode.
Table 1. Stand-alone DIP switch settings
14 Cyclo 03 Directional user manual
Page 15
A quick reference table covering DIP switch functions is also provided on
Blue
100% Blue
0% Red
50% Blue
50% Red
0% Blue
100% Red
the back cover of this manual.
Stand-alone operation settings
Activating colors
DIP switch pins 1 to 3 each activate a color in the stand-alone program.
Setting program speed
Combinations of DIP switch pins 5 and 6 allow one of four different speeds to be set.
Fading between colors
If DIP switch 7 is set to OFF (blackout fading), colors fade to almost blackout before the next color fades in.
100%
50%
0%
If DIP switch 7 is set to ON (crossfading), color fading overlaps. If two or more colors are active, one color fades in while another is fading out, giving a color mixing effect. For example, if red and blue are activated and crossfading is selected, colors will crossfade from red through purple to blue, then back through purple to red in a continuous cycle (see example).
Red
Blue
100% Blue
0% Red
Blue
50% Red 50% Blue
Purple
100% Red
0% Blue
Time
Red
Example: crossfading between red and blue
Stand-alone operation 15
Page 16
Setting a static color display
In stand-alone operation, a static (non-changing) color display can be set by pausing the program at the point where it is showing the desired color. Either one color or a mix of two colors can be “frozen” in this way.
To set a static color display:
1. Activate the color you wish to display (if you wish to display a two-color mix, activate these two colors) on DIP switch pins 1 to 3.
2. Set the luminaire as master by setting DIP switch pin 9 to OFF.
3. Set DIP switch pins 5 and 6 to ON to activate the slowest program speed.
4. Set DIP switch pin 7 to OFF to activate crossfading and DIP switch pin 8 to OFF to activate the program.
5. When the desired color or color mix appears, pause the program by moving DIP switch 8 to ON. This color will remain “frozen” until DIP switch 8 is moved to OFF.
Note that the paused color is lost when the luminaire is powered off. When powering the luminaire on again, DIP switch pin 8 must be moved to OFF before the program will start.
Single stand-alone operation
In single stand-alone operation, a luminaire runs its own program independently of all other luminaires. To do this, the luminaire must be set as a master.
Activating single stand-alone operation
To activate single stand-alone operation:
1. Set DIP switch pin 10 to ON (activates stand-alone mode).
2. Set DIP switch pin 9 to OFF (activates master mode).
3. Apply power and program the luminaire using DIP switch pins 1 - 8 (see "Table 1. Stand-alone DIP switch settings" on page 14).
Master/slave stand-alone operation
Important! Do not set more than one luminaire on a data link as master,
and do not set a luminaire as master on a data link with a DMX
16 Cyclo 03 Directional user manual
Page 17
controller. Doing so may cause damage to the electronics that is not covered by the product warranty.
In master/slave stand-alone operation, one master luminaire transmits a synchronizing signal to slave luminaires over the data link each time it starts a new action. Slave luminaires start their next programmed action when they receive this signal from the master luminaire. Programs can be identical on all luminaires, or luminaires can – subject to certain practical constraints – run programs that are synchronized but not identical.
Note that:
• Colors are always displayed in the order: red, then green, then blue. This means that if red is activated, it will always be first in the program. If red is not activated but green is activated, green will be first in the program.
• Each luminaire follows the program set on its own DIP switch as described in "Table 1. Stand-alone DIP switch settings" on page 14.
More sophisticated light shows can be programmed using a DMX controller (see “DMX controlled operation” on page 21).
The synchronization signal used by the Cyclo 03 Directional is identical to that used in other 3-tube Cyclo luminaires, allowing these products to be combined in master/slave operation on one data link. However, it is not compatible with 4-tube Cyclos. Consult your Martin Architectural dealer if you need advice on combining and controlling products.
Identical light shows
Master and slave luminaires can be set to behave identically. In this mode, the master sends synchronizing signals to the slaves, and all luminaires run the same light show. Each slave luminaire follows the program set on its own DIP switch, so for identical operation, all luminaires’ DIP switch settings must be the same apart from pin 9, which is set to ON for slaves and OFF for the master.
Synchronized non-identical light shows
It is also possible to synchronize changes but program slave luminaires to behave differently from the master. To use this feature effectively, you need to plan your light show using scenes as building blocks and set the luminaires’ DIP switches accordingly.
A scene is a change from one ouput to another. When a luminaire is in slave mode, it starts a scene when it receives a synchronization signal from the master. The time taken by the scene is determined by the speed setting of the DIP switch. A slave will not respond to new synchronization signals until its scene is complete.
Stand-alone operation 17
Page 18
When crossfading is selected, each color takes up one scene (fade in only). When blackout fading is selected, each color takes up two scenes (fade in and fade out). This means that a maximum of 6 scenes can be programmed with all 3 colors activated and blackout fading selected.
Each time the master luminaire starts at scene 1, it sends a signal to all the slave luminaires to start at scene 1. This means that if a slave luminaire has:
1. Fewer scenes than the master luminaire, it will run these in a cycle until the master luminaire signals that the program should start from the beginning again.
2. More scenes than the master, the additional scenes will never run, because the program will reset to the first scene when the master starts its program from the beginning.
Here is an example of what will happen when a slave luminaire has fewer scenes than the master luminaire:
Luminaire setting Scene pattern
Master with 6 scenes 123456 123456 123456 ... Slave with 4 scenes 123412 123412 123412...
Program examples
The following examples show how an individual luminaire’s program is made up of scenes.
The following symbols are used in program diagrams:
Tube turned fully off
Fade in
Fade out Fade to 50% and back to 100% in one scene
(applies when only one color is active and crossfading is selected)
Example 1
DIP switch 7 is set to ON (crossfading) and only red is activated:
18 Cyclo 03 Directional user manual
Red
Scene
1 1 11 111 1 111 1
Page 19
Example 2
DIP switch 7 is set to OFF (blackout fading) and only red is activated:
Red
Scene
21 21 21 21 21 21
Example 3
DIP switch 7 is set to ON (crossfading) and red and blue are activated:
Red
Blue
Scene
1 2 21 211 2 21 21
Example 4
DIP switch 7 is set to OFF (blackout fading) and red and blue are activated:
Red
Blue
Scene
21 43 421 3 421 3
Example 5
To achieve a rainbow effect, activate red, green and blue and set DIP switch pin 7 to ON (crossfading).
Red
Green
Blue
Scene
1 2 3 1 2 3 1 2 3 1 2 3
Activating master/slave stand-alone operation
To activate master/slave stand-alone operation:
1. Power all luminaires off.
2. Set all luminaires as slaves and put them into stand-alone mode by setting DIP switch pins 9 and 10 to ON.
3. Decide which luminaire to use as master and set this luminaire’s DIP switch pin 9 to OFF. Note that any luminaire can be set as master, but
Stand-alone operation 19
Page 20
you will obtain the most reliable data signal by either setting the first luminaire on the link as master or using RJ-45 DMX termination plugs at both ends of the data link.
4. When power is applied, slave luminaires will go to the next scene in their program each time the master goes to its next scene. Slave luminaires will also start scene 1 of their programs each time the master starts scene 1 of its program.
20 Cyclo 03 Directional user manual
Page 21
DMX controlled operation
The Cyclo 03 Directional may be programmed and operated with any lighting control device that is compatible with the USITT DMX standard.
See also “DMX protocol” on page 30.
Connecting a DMX control device
Connect a data cable to the DMX control device’s data output and one of the Cyclo 03 Directional’s RJ-45 DMX sockets. If your control device has an XLR data output socket, you may need to buy or wire an XLR-to-RJ45 converter. For details of wiring and polarity, see “Data linking multiple luminaires” on page 12.
Setting a luminaire to DMX operation
DMX operation is enabled by setting pin 10 on the DIP switch to OFF. Pins 1 - 9 are then used to set the luminaire’s control address.
Setting a DMX control address
The Cyclo 03 Directional uses 3 DMX control channels. The DMX address, also known as the start channel, is the first of these channels. It must be set on the luminaire and selected on the DMX controller before the controller can send commands to the luminaire via a DMX link.
The Cyclo 03 Directional responds to commands sent to the DMX address and the next two channels. If the DMX address is set to 100, the Cyclo 03 Directional uses channels 100, 101 and102.
Allow enough channels when setting the DMX address. If control channels for one luminaire overlap control channels for another luminaire, one of the luminaires will receive the wrong commands.
If two or more Cyclo 03 Directionals share the same DMX address, they will receive the same commands and respond identically. Individual control will be impossible.
DMX controlled operation 21
Page 22
The default factory-set control address is ‘1’.
To set the Cyclo 03 Directional’s DMX address:
1. Set DIP switch pin 10 to OFF.
2. Decide on a DMX address for the luminaire. If you are calculating the DMX addresses for multiple fixtures, save time by using the online Martin Address Calculator at http://www.martin.dk/service/utilities/AddrCalc/index.asp (see illustration below).
3. You can also look up DIP-switch settings using the Martin DIP Switch
Calculator, available for use and downloadable at http://www.martin.dk/service/dipswitchpopup.htm If you do not have Internet access, refer to "Table 2: DIP switch address settings" on page 23.
4. Set DIP switch pins 1 through 9 to ON (1) or OFF (0) with reference to
the table.
22 Cyclo 03 Directional user manual
Page 23
Find the address in the table. Read the settings for pins 1 - 5 to the left and read the settings for pins 6 - 9 above the address. “0” means OFF and “1” means ON. Pin 10 is always OFF for DMX operation.
For example, to set the DMX address to 101, you need to set DIP-switch pins 1, 3, 6 and 7 to ON. The DIP switch settings for Channel 101 are highlighted in the table.
DIP switch Setting
0 = OFF
1 = ON
#1 #2 #3 #4 #5
0 0 0 0 0 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481 0 1 0 0 0 2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482 1 1 0 0 0 3 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483 0 0 1 0 0 4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484 1 0 1 0 0 5 37 69 101 133 165 197 229 261 293 325 357 389 421 453 485 0 1 1 0 0 6 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486 1 1 1 0 0 7 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487 0 0 0 1 0 8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488 1 0 0 1 0 9 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489 0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498 1 1 0 0 1 19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499 0 0 1 0 1 20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500 1 0 1 0 1 21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501 0 1 1 0 1 22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502 1 1 1 0 1 23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503 0 0 0 1 1 24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504 1 0 0 1 1 25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505 0 1 0 1 1 26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506 1 1 0 1 1 27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507 0 0 1 1 1 28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508 1 0 1 1 1 29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509 0 1 1 1 1 30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510 1 1 1 1 1 31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511
#90000 000011111111 #80000 111100001111 #70011 001100110011 #60101 010101010101
Table 2: DIP switch address settings
DMX controlled operation 23
Page 24
Controlling via DMX
The Cyclo 03 Directional’s advanced fluorescent tubes can be dimmed from maximum output right down to zero using three channels on a DMX controller. This allows a wide range of color shades with almost infinitely variable intensity to be obtained using additive color mixing. The color temperature of white light can also be fine-tuned.
Depending on the functions available on the controller, sophisticated light shows on the Cyclo 03 Directional can be programmed over time, allowing constantly and rapidly shifting color mixes, or color displays which change slowly according to the time of day, or even year, for example. See the controller’s manual for details.
Your Martin Architectural dealer can advise about available controllers and control options.
Page 25
Service
With long-life fluorescent tubes and no moving parts, the Cyclo 03 Directional is almost service-free.
Fluorescent tube replacement
The Osram high output T5 tubes fitted as standard meet color specifications for at least 10 000 hours, after which color intensity may gradually fall. Average tube life is 20 000 hours, but note that tube life will vary depending on operating conditions.
No tools are required to replace a fluorescent tube on the Cyclo 03 Directional.
The reflector and diffuser must be removed for access to the tubes. These two components are attached to the luminaire housing by safety wires and can be left hanging from these wires during tube replacement.
Diffuser
Reflector
Service 25
Page 26
To change a tube:
1. Isolate the luminaire from the power supply and ensure that power cannot be reapplied, even accidentally.
2. Ensure that the luminaire is securely mounted before beginning any servicing work.
3. The reflector is held in place by metal spring clips. Hold the second fin from each end firmly and pull downwards to release the reflector. If the reflector is difficult to move by pulling, insert a small screwdriver between the reflector and the housing, next to the second fin from the end, to help release the clip.
26 Cyclo 03 Directional user manual
Page 27
4. The diffuser is held in place by metal clips at each end of the luminaire. Push a clip back and remove the diffuser. You now have access to the tubes.
5. Pressing on the metal caps at both ends of the tube, rotate the tube 1/4 turn in whichever direction is easiest, and slide the tube’s terminal pins out of their sockets. Support the tube at both ends as it is released.
6. To install a new tube, line it up so that the manufacturer’s markings on all tubes are at the same end of the luminaire. Slide the tube’s terminal pins fully into their sockets and rotate the tube 1/4 turn to engage the pins. Check that the tube is held securely in the sockets.
7. Replace the diffuser and then the reflector by pushing them onto their clips before reapplying power.
Service 27
Page 28
Tube positions
Tube positions in the Cyclo 03 Directional are identified as follows:
Marking in luminaire
R
G
B
The burning positions of fluorescent tubes affect their operating temperature, light output and tube life. For best results:
• Install tubes so that the manufacturer’s markings are all at the same end of the luminaire.
• If the luminaire is mounted in a vertical position or at an angle from the horizontal, place the ends of the tubes that carry the manufacturer’s markings at the lower end of the luminaire.
Marking on tube Reference illustration
OSRAM FQ 54W/60 RED
OSRAM FQ 54W/66 GREEN
OSRAM FQ 54W/67 BLUE
R G B
Cleaning
Turn off power to the luminaire before cleaning, and use a damp cloth to wipe clean.
28 Cyclo 03 Directional user manual
Page 29
Troubleshooting
Problem Probable cause(s) Remedy
No response from fixture when power is applied.
Fixture does not respond correctly to DMX control.
In stand-alone mode, DIP switch pin 8 set to ON (pause).
No power to luminaire. Check power connections. No power to lighting track. Check power connection to
Ground fault protection circuit breaker (RCD) has tripped.
Controller not connected. Check DMX data link. Inspect
Incorrect DMX addressing. Check address setting on
Data link not terminated. Insert RJ-45 termination plug
Two devices transmitting on link.
Set DIP switch pin 8 to OFF to resume stand-alone program.
lighting track. Reset RCD. If problem
persists, have an electrician replace the RCD or reduce the number of fixtures powered via one RCD.
connections and test cables. Repair or replace as necessary.
fixture and controller.
in unused socket of last fixture on data link.
Check that all luminaires are set as slaves (DIP s witch pin 9 ON).
Fixtures do not behave correctly in master/slave mode
Poor quality light output and/or color rendering.
Defective luminaire. Bypass luminaires one at a
time until normal operation is regained.
Two luminaires transmitting on link.
Defective luminaire. Bypass luminaires one at a
Tube or tubes not burnt in. Run luminaire for at least 100
Tube defective. Disconnect luminaire and
Check that only one luminaire is set to operate as master.
time until normal operation is regained.
hours to burn in tubes.
replace tube.
Troubleshooting 29
Page 30
DMX protocol
Channel Value Percent Function
1
2
3
0-2
3-252
253-255
0-2
3-252
253-255
0-2
3-252
253-255
1 - 99
100
1 - 99
100
1 - 99
100
Start code = 0
Red intensity
0
0
0
Tube off Intensity 1 Intensity 100%
Green intensity
Tube off Intensity 1 Intensity 100%
Blue intensity
Tube off Intensity 1 Intensity 100%
100%
100%
100%
30 Cyclo 03 Directional user manual
Page 31
Cyclo 03 Directional
PHYSICAL
L x W x H (with mounting arms) . . . . . . . . . . . . . .1200 x 107 x 285 mm
L x W x H (without mounting arms) . . . . . . . . . . . .1200 x 107 x 218 mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.7 kg (19.3 lbs)
Luminaire colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Titanium, white
SOURCE
Light source. . . . . . . . . . . . . . . . . . . . . . . T5 fluorescent tubes (3x54W)
Approved lamp type . . . . . . . . . . . . . . . . . OSRAM T5 high output 54W
Color authenticity . . . . . . . . . . . . . . . . . . . Guaranteed to 10 000 hours
Average tube life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 000 hours
DYNAMIC EFFECTS
0-100% dimmable tubes . . . . . . . . . . . . . . . . . . . . .Red, green and blue
Specifications
(47.3 x 4.2 x 11.2 in.)
(47.3 x 4.2 x 8.6 in.)
CONTROL AND PROGRAMMING
Control options . . . . . . . . . . . . . . . DMX512, stand-alone, master/slave
Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-485
Setting and addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIP switch
Data input/ output . . . . . . . . . . . . . . . . . . . . . . . . RJ-45 (through-wired)
Number of DMX channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION
3-phase lighting track mounting with universal track adaptor Surface mounting with optional mounting brackets
Orientation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Any
Minimum free space around luminaire . . . . . . . . . . . . . . 25 mm (1 inch)
THERMAL
Maximum ambient temperature (T
Maximum total heat dissipation. . . . . . . . . . . . . . . . . . . . . . 618 BTU/hr.
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Convection
POWER
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 V - 254 V, 50 / 60 Hz
Maximum power and current @ 208 V / 50 Hz . . . . . . . . 0.87 A / 180 W
Maximum power and current @ 230 V / 50 Hz . . . . . . . . 0.80 A / 181 W
Maximum power and current @ 250 V / 50 Hz . . . . . . . . 0.73 A / 179 W
AC input . . . . . . . . . . . . . . . . . . . . . . . . . . EnstoNet Installation System
) . . . . . . . . . . . . . . . . 40° C (104° F)
a
Cyclo 03 Directional Specifications 31
Page 32
CONSTRUCTION
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mild steel
Optics . . . . . . . . . . . . . . . . . . . . . . . . . . High specular 99.9% aluminum
INCLUDED ITEMS
Red T5 high output fluorescent tube . . . . . . . . . . . OSRAM FQ 54W/60
Green T5 high output fluorescent tube . . . . . . . . . OSRAM FQ 54W/66
Blue T5 high output fluorescent tube. . . . . . . . . . . OSRAM FQ 54W/67
ENSTO 3 pole 16A/250V male connector . . . . . . . . . . . . P/N 05347202
ENSTO 3 pole 16A/250V female connector . . . . . . . . . . P/N 05327202
User manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 35000163
ACCESSORIES
Wall/ceiling bracket (set of 2), titanium . . . . . . . . . . . . . . .P/N 91611187
Wall/ceiling bracket (set of 2), white . . . . . . . . . . . . . . . . .P/N 91611186
Termination plug RJ-45 . . . . . . . . . . . . . . . . . . . . . . . . . P/N 91613028
RJ-45 connector (15 cm/ 5.9 in.) . . . . . . . . . . . . . . . . . . P/N 11840088
ENSTO male/female cable (15 cm/5.9in.) . . . . . . . . . . . P/N 11501019
XLR male to RJ-45 converter . . . . . . . . . . . . . . . . . . . . . P/N 11840087
XLR female to RJ-45 connector . . . . . . . . . . . . . . . . . . . P/N 11840086
50 x CAT5 network cables - 2 m (6.5 ft) . . . . . . . . . . . . . P/N 91611044
30 x CAT5 network cables - 5 m (16.4 ft) . . . . . . . . . . . . P/N 91611045
15 x CAT5 network cables - 10 m (32.8 ft) . . . . . . . . . . . P/N 91611046
ORDERING INFORMATION
Cyclo 03 Directional, titanium . . . . . . . . . . . . . . . . . . . . . P/N 90550055
Cyclo 03 Directional, white . . . . . . . . . . . . . . . . . . . . . . . P/N 90550050
32 Cyclo 03 Directional user manual
Page 33
Page 34
Page 35
Page 36
3. Blue
8. ON = Pause OFF = Play
9. ON = Slave or DMX OFF = Master
2. Green
1. Red
4. Not used
5/6. Program speed
10. ON = Stand-alone OFF = DMX
1 2 3 4 5 6 7 8 9 10
ON
7. ON = Crossfading OFF = Blackout fading
Quick reference