Glass Doors, Fan Assembly, and Outside Combustion Air Kit Available
MODELS:
400BWBA 400BWBIA 400BWBCA 400BWBCIA
500BWBA 500BWBIA 500BWBCA 500BWBCIA
400BWBA and
500BWBA Series
Radiant Type
These fireplaces are U. L.
Only Unvented Gas Log Sets which have been found to comply with the Standard For Unvented Room
Heaters ANSI Z21.11.2, are to be installed in this fireplace. A hood must be installed when mantle is
installed at 12” from fireplace opening.
READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS
400BWBCA and
500BWBCA Series
Circulating Type
®
listed for use with “S” Series chimney system components.
Page 2
CONTENTS
CONGRATULATIONS!
You have chosen the finest wood burning fireplace available. Your fireplace has been
designed for years of heating and viewing enjoyment. Please take time to read this entire
manual before installing or operating your fireplace.
Listing and Code Approval ..............................................2
Important Safety Information .......................................... 3
Glass Door Maintenance ........................................... 36
Checklist of DOs and DON’Ts .................................... 37
Replacement parts .........................................................39
Warranty .......................................................... Back Cover
28
LISTING AND CODE APPROVALS
The instructions contained in this manual provide the information necessary to install this fireplace in accordance with
Underwriterʼs Laboratories requirements and in compliance with the National Fire Protection Association Standard No. 211.
Some codes may require the fireplace and chimney be electrically grounded. Before beginning the installation, check with
local building officials to obtain required permits and assure compliance with local regulations and codes. If you encounter
problems with code requirements, contact your dealer for assistance.
IMPORTANT: This fireplace is listed by Underwriters Laboratories to U.L. 127 standard for factory-built fireplaces. The design
of this fireplace and these instructions complied with applicable safety standard for a factory built fireplace in effect at the time
the fireplace was manufactured. You should be aware, however, that failure to install, operate, and maintain this or any other
factory built fireplace properly can result in a house fire or other occurrences that could cause deaths, injuries, and property
damages. Persons installing and/or supervising the installation of this fireplace must have appropriate skills in using the tools
and techniques required and have reading and comprehension skills sufficient to read and follow these instructions. These
instructions contain warnings, cautions, and notes to emphasize important safety information. To assure that safe and satisfactory service is received from this fireplace, please read the following special notices and all the contents of this manual.
2 61D0008
Page 3
IMPORTANT SAFETY INFORMATION
INSTALLER
Please leave these instructions with the owner.
• Read these instructions entirely before beginning any part of the installation. Save
these instructions for any future repairs.
• Use these instructions as a guide during the installation of the fireplace.
• Install all the parts used with this fireplace system in accordance with these installation
instructions. Failure to do so may be hazardous and will void the warranty.
• Do not alter fireplace and accessories in any way that is not specifically recommended
in this manual.
• Refer to your local building code for local requirements pertaining to installation of
factory-built fireplaces. Martin Hearth and Heating fireplaces are intended for installation
WARNING
and use according to standard NFPA 211 of the National Fire Protection Association.
• Do not install fireplace with a masonry flue.
• Do not pack required air spaces with combustible material or insulation not specifically
recommended for use in such areas.
OWNER
Please retain these instructions for future reference
.
This fireplace is NOT designed for installation in manufactured homes without a vented
attic space. Fireplace may be installed in manufactured homes which have a vented
attic space if the fireplace is equipped with GD36BA, GD36PBA, GD36SSA, GD42BA,
GD42PBA or GD42SSA glass doors, an AK6 outside combustion air kit (instead of the
AK4 outside combustion air kit offered for residential type homes as described later
NOTICE
by this instruction manual), a SVTR firestop thimble, and the minimum installed height
from floor to flue outlet is 13'. (See Figure 14, page 16.)
Do not use a fireplace insert or other
product not specified for use with
this fireplace.
CAUTION
Improper installation or use of this fireplace will void its warranty and can cause:
• Damage to the fireplace from overheating.
• Hazardous temperatures to develop on combustible materials adjacent to the fireplace
or chimney.
• The emission of smoke, sparks or hazardous gases into the dwelling.
WARNING
• Leakage of rain water into the dwelling.
61D0008 3
Page 4
OPERATION GUIDELINES
HOW YOUR FIREPLACE SHOULD BE USED
This fireplace is intended for supplemental heating only and
is not intended for use as a primary heating system.
This fireplace is designed to sit directly on a combustible
floor. The fireplace must be installed with clearances to combustible building materials as specified by this manual. Only
parts manufactured by Martin Hearth and Heating and labeled
for use with this fireplace should be used in the installation
of the fireplace except for special roof flashings that may be
fabricated locally. The use of improper parts in the installation
can be hazardous and voids the warranty offered by Martin
Hearth and Heating.
This fireplace is designed to burn solid wood fuel (wood),
UL- classified processed solid fuel fire logs, or a certified
decorative gas appliance may be installed in the fireplace as
described later by this instruction manual.
This fireplace is not designed to burn coal, unplumbed liquid
fuels, unplumbed gaseous fuels or household refuse. Any
attempt to burn these fuels in the fireplace can be hazard
ous.
HOW YOUR FIREPLACE WORKS
As wood is burned in the fireplace, room air entering the
fireplace is circulated around the fireplace firebox. This air
circulation protects the firebox from overheating. Air circulation through the fireplace must not be blocked or restricted
in any manner. Blocking or restricting air circulation through
the fireplace can cause a fire hazard.
RESIDENTIAL INSTALLATION
air; this permits flexibility in planning your installation. See
Figures 24 thru 27 and their instructions for typical installation of outside combustion air kits. Review the precautions
and recommendations in this manual pertaining to outside
combustion air.
Note: Outside air for combustion is optional in
residential type installations unless required
by local codes. Outside air for combustion
it is mandatory in manufactured home
installations. Use an AK6 outside combustion
air kit in manufactured home installations,
instead of the AK4 offered for residential type
installations.
GLASS DOORS
Glass doors (models GD36BA, GD36PBA, GD36SSA,
GD42BA, GD42PBA and GD42SSA by Martin Hearth and
Heating) may be installed to receive the maximum benefit
from your fireplace. For large fires, the maximum heating
benefit from the fireplace will be obtained with the doors open
due to the high amount of radiant heat being emitted out of
the front opening of the fireplace. With a small fire, or before
retiring in the evenings, it is best to operate the fireplace with
the doors closed to prevent excessive room air from being
drawn up the chimney. When the doors are open, the mesh
screens should be closed to help keep burning embers from
popping out of the firebox.
Note: Glass doors are mandatory on fireplaces
installed in manufactured homes.
In residential type installation, an AK4 outside combustion air
kit may be connected to the left side of the fireplace to allow
outside air to enter the firebox through a dampered opening in
that side of the fireplace. This outside combustion air feature
reduces the room air used for combustion and prevents exces
sive heat loss from the room. When the fireplace is in use,
the fireplaceʼs “outside combustion air” damper connected
to an AK4 may be opened to allow air from outside to enter
the fireplace firebox. When the fireplace is not in use, the
“outside combustion air” damper should be closed to prevent
cold air from entering the firebox. An “outside combustion
air” damper is open when its control lever is up and closed
when its control lever is down. A control lever for the outside combustion airdamper is located inside the firebox near the top
of the side firebrick on the left side of the fireplace. The design
of the fireplace allows the routing of the combustion air duct
downward or horizontally to obtain the outside combustion
4 61D0008
-
Fireplaces equipped with glass doors
should be operated only with the
glass doors fully open or fully closed.
If doors are left partly open, gas and
flame may be drawn out of the fireplace
opening, creating risks of both fire and
WARNING
smoke.
Page 5
OPERATIONAL GUIDELINES
FLUE DAMPER
The fireplace also is equipped with a flue damper which must
be open when the fireplace is in use. The flue damper control
lever is located inside the fireplace. The counterweighted
damper is operated by simply unlocking up to open or pulling
and locking down to close the damper. When the fireplace is
not in use, the damper should be closed to prevent cold air
form entering the chimney as well as preventing warm air in
the room from escaping up the chimney.
Note: It is normal for a small amount of smoke to
be released from the upper portion of the
fireplace the first few times you use your
new Martin Hearth and Heating fireplace.
This results from an oil residue on the metal.
Open a door or window to allow the smoke
to escape.
GRATE
The grate included with this fireplace helps to appropriately
locate and contain the burning wood.
Failure to use this grate may cause
overheating of parts of the fireplace
and allow large pieces of burning
wood to roll forward out of the firebox.
Replace warped or damaged grate
only with a Martin Hearth and Heating
WARNING
grate.
CHIMNEYS
All fireplace chimneys are in direct contact with cold air on the
exterior of the structure. Consequently, when the fireplace is
not in use, cold air can fall down the chimney of the fireplace
to cool off the fireplace chase. Therefore, the fireplace chase
must be insulated to minimize the risk of cold coming into
the home. Even if the fireplace chase is adequately insulated,
this cannot completely ensure that cold air coming into the
structure will be eliminated. Cold air coming inside is a possibility with any fireplace or device that freely uses air on the
outside of the structure. Todayʼs homes are more energy-efficient and, therefore, better insulated and tightly constructed.
Unfortunately, when air is removed from the house (by a
bathroom fan or consumed by a furnace) additional air is
needed to replace the air consumed. Unless the additional air
is supplied, this can cause a negative pressure in the home.
When this happens, the house will draw in outside air from
the cracks in the windows, down the fireplace flue or other
locations of air leakage in the home. Because cold air coming
in may be unavoidable in some structures, Martin Hearth
and Heating is not responsible for heat loss or air infiltration
through or around the fireplace.
61D0008 5
Page 6
PRODUCT FEATURES
PRODUCT SPECIFICATIONS
• This fireplace is designed to burn solid wood fuel (wood), UL-classified processed solid fuel fire logs, or a certified
decorative gas appliance may be installed in the fireplace as described later by this instruction manual.
• The appliance must be properly connected to a venting system.
Optional
Fan
Switch
Screens
Grate
Figure 1 - Wood Burning Fireplace
(Circulating Unit Shown)
6 61D0008
Page 7
FIREPLACE LOCATION
Plan for the installation of your fireplace. This includes determining
where the unit is to be installed, the vent configuration to be used, framing
and finishing details, and whether any optional accessories (i.e. blower,
wall switch, or remote control) are desired. Consult your local building
code agency to ensure compliance with local codes, including permits
and inspections.
The following factors should be taken into consideration:
• This fireplace should have sufficient access for its safe operation and maintenance.
• Locate a position where the flue system of the fireplace can be properly installed without damaging the integrity
of the building. e.g. cutting wall or ceiling joist (example: load-bearing framing members).
• Install floor protection when the appliance is installed directly on tile or other combustible material.
• Check fireplace and flue system clearance requirements.
• Locate the fireplace in a large and open room that is centrally located in the house. This will optimize heat
circulation and comfort.
• Locate fireplace away from frequently opened doors, central heat outlets or returns, or other places where air
movements may disturb the airflow around the fireplace.
Note: Air turbulence near the fireplace may cause smoke to spill out of the fireplace opening.
Do not install fireplace
over carpeting.
CAUTION
• Locate fireplace near a load bearing wall. Make sure the support structure is strong enough or reinforced if
fireplace is to be trimmed with a heavy stone or brick facing and hearth extension.
• This fireplace may be installed along a wall, across a corner, or use an exterior chase. See Figure 2 for suggested locations.
• Location should be out of high traffic areas and away from furniture and draperies.
• Never obstruct the front opening of the fireplace.
• Do
• Vent pipe routing. See Venting section found in this manual for allowable venting configurations.
• Minimum clearances to combustibles, side-wall, ceiling, woodwork, and windows must be maintained. See Clearances
not install in the vicinity where gasoline or other flammable liquids are stored.
• Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc. This could make installation
harder. It could also be a hazard for persons installing or cleaning the chimney.
• Do not install where the chimney cap will be near abrupt changes in the roof shape, nearby wall or embankments, under
or near trees or above the roof of a single story wing of a two story building. See Figure 4. Any of these conditions may
cause turbulence or pressure condition which may create poor chimney draft and smoke spillage from the fireplace opening into the home.
• Use elbows to offset the chimney to avoid obstructions or to locate the chimney cap in a better location. See Chimney Offsets Section on pages 18 and 21 for instructions on proper elbow use. Poor installation or location of the chimney cap
and/or components can cause wind blown rain to enter the chimney.
• The selected location must have a 15" square combustible material-free space for the chimney to pass through.
• If the chimney is to pass through living or storage spaces, there must be adequate space to enclose the chimney to avoid
personal contact with, or damage to, the chimney.
Continued
Preferred
Location
Poor
Location
Figure 4 - Preferred Chimney Location
61D0008 9
Page 10
SCL Telescoping
Chimney Cap
Flat Chase Flashing
R3672 (36"x72")
or
R4884 (48"x84")
Chimney Sections
“S” Series
Insulate Outside
Walls of Chase
Solid Continuos
Surface
Insulation
(Thermal Barrier)
Outside Base
Solid
Surface
8'0"
Level
Joist Insulate
Same as Ceiling
See
Warning
Below
SF Firestop
Spacer
INSTALLATION PREPARATION
LOCATING CHIMNEY (CONTINUED)
• If the fireplace is to be installed on an outside wall, the surrounding walls (chase) must be constructed and insulated.
See Figure 5. If you do not insulate the fireplace from outside temperatures, heat loss through and around the fireplace
will occur.
• You must use Model SF Firestop
• It is recommended for safety and reducing heat loss that firestopping be used at the
• Do not insulate chase with blown or fill type insulation. Only allow insulation to come
WARNING
Figure 5 - Installing Fireplace on an Outside Wall
ceiling level for chase installation even if local codes do not require firestopping.
into contact with fireplace at points where fireplace would normally be contacted by
framing materials.
10 61D0008
Page 11
8"
Min.
6" Min. Brick
or Stone
from Top
of Platform
Brick or Stone Hearth Extension
52" (400 Models)
66" (500 Models)
16" Min.
(400 Unit)
20" Min.
(500 Unit)
8"
Min.
6" Min. Brick
or Stone
from Top
of Platform
Brick or Stone Hearth Extension
52" (400 Models)
66" (500 Models)
16" Min.
(400 Unit)
20" Min.
(500 Unit)
FLOOR PROTECTION
INSTALLING FIREPLACE ON COMBUSTIBLE FLOOR
If fireplace is installed on a combustible floor, protect the floor area either side of the fireplace opening and in the front
with an insulating non-combustible hearth extension. (16" [400 unit] or 20" [500 unit] minimum in front of fireplace and
8" minimum on both sides. See Figures 6 through 12.
Fireplace
Hearth Extension Clearances & Width
400 Unit 500 Unit
On Both Sides 8" Min. 8" Min.
Front of Fireplace 16" Min. 20" Min.
Extension Width 52" 66"
Air Vents — DO NOT BLOCK
Metal Safety Strip Must Be
Use if Unit Is Placed on
Combustible Floor
Figure 6 - Installing Floor
Protection (Circulating Model)
Note: Do not block the side air
vents or air inlet louvers on
the lower front of the fireplace
with hearth extension.
Air vents and air inlet louvers allow
necessary cooling air around the fireplace. Determine the finished height of
the hearth extension to be used. Raise
the fireplace on a platform, if necessary,
to prevent blocking of air openings and
lower louvered panel.
Note: No platform is needed if
hearth extension does
not exceed 1" thick for
circulating units or 6½" for
radiant units.
61D0008 11
Platform May Extend Under Hearth
Extension if Desired
Safety Strip
3"x36" Min. (400 Unit)
3"x42" Min. (500 Unit)
16" Min.
(400 Unit)
20" Min.
(500 Unit)
21"
211/2"
40
1
/2"
40
1
/8" (400 Unit)
46
1
/8" (500 Unit)
16"min. - 400 unit
20" min. - 500 unit
8"8"
FLOOR PROTECTION
INSTALLING FIREPLACE ON COMBUSTIBLE FLOOR (CONTINUED)
This hearth extension must be either 6" (minimum) thick stone or brick; a H1652 (400 units) or H2066 (500 units) Hearth
Extension Kit; or a locally constructed hearth that has a “K” factor less than .43 and at least ½" thick. For other non-combustibles, the total thickness minimum is 1.16 times its thermal conductivity (K).
The following relations could be useful —
C = K divided by the material thickness
(Example C = .43 divided by 1/2 (.50)
C = .86)
K = C multiplies by the material thickness
(Example K = .86 multiplied by 1/2 (.50)
K = .43)
R = The material thickness divided by K
(Example R = 1/2 (.50) divided by .43
R = 1.16)
C = Thermal Conductant
R = Thermal Resistance
Minor shifting of the supporting floor or
expansion and contraction may eventually
cause a crack to develop between the hearth
extension and the face of the fireplace with
either type hearth extension. To help prevent
the cracking, firmly fasten the hearth extension
materials in place. Screw wall ties to the face of
the fireplace. Imbed the wall ties in the mortar
joints of brick, stone, or other non-combustible
materials.
Gas
Opening
Junction
Box
Opening
Floor
Level
Place metal safety strip packed with the
fireplace beneath the fireplace. Extend metal
safety strip under the hearth extension or into
a mortar joint of the hearth. See Figures 6 through 9. If a crack does eventually develops,
the metal safety strip will prevent sparks or
embers from falling from the fireplace onto
combustible flooring materials.
12 61D0008
Figure 9 - Installing Hearth Extension and Metal Safety Strip
Figure 8 - Installing Hearth Extension
Fireplace
Hearth
(Circulating Model Shown)
Only install metal safety
strip horizo ntal to the
fireplace.
Unpack and check the fireplace and chimney for damage. If any items are been damaged or missing, contact your Martin Hearth
and Heating dealer. Do not substitute parts. Use only parts listed for use with Martin Hearth and Heating Models 400BWBA,
400BWBIA, 400BWBCA, 400BWBCIA. 500BWBA, 500BWBIA, 500BWBCA and 500BWBCIA fireplaces.
CLEARANCES
1. Provide required clearances shown in Figures 10 through 12. Provide 2" minimum chimney air space clearance to com-
bustibles.
2. Place fireplace in the desired location. Securely support and level fireplace. Check face of the fireplace with a carpenterʼs
level. If fireplace is not plumb, correct it by placing shims under the edges of fireplace.
3. Block in the fireplace to prevent any shifting of firebox. Secure fireplace with nails or screws through the flanges located on
each side of the fireplace. Do not enclose the fireplace until the combustion air duct and chimney pipes are installed.
Note: Some local codes may require electrically grounding the fireplace and chimney.
Continued
Figure 10 - Minimum Clearances for Corner
Installation
61D0008 13
Figure 11 - Minimum Clearances for Wall Installation
Page 14
20' min. Height (4-30 Elbows)86' max. Height (Chimney Support Every 30')
StormCollar
Bottom of Fireplace
Warm Air Outlet — Do Not Block
Galvanized Metal Strip
Glass Door Accessory
Cool Air Inlet — Do not Block
Nail to Framing Members
Round Chimney Cap
Model SC
Flue Outlet Height
Roof Flashing Model 612
Firestop - Model SF(Requires 15"x15" Opening)2" min. Air Space to Combustibles
Top Spacer
Flexible DuctType FP-4-U
Combustion Air Assembly Model AK4
Front-to-BackFraming Dimensions
403/4"
Framing
Dimension
401/2" - 400 Units46
1
/2" - 500 UnitsFraming Dimension
21
3
/4"
Chimney (2" min. Air Space)to Combustibles —S12 1' PipeS18 18" Pipe
S36 3' PipeS48 4' Pipe
FIREPLACE INSTALLATION
CLEARANCES CONTINUED
Figure 12 - Proper Clearances and Chimney Height
14 61D0008
Page 15
A
A
3' min.
Flue Outlet
Height
Flue Outlet
Height
Flue Outlet
Height
3' min.
2' min. when
Dim. “A” is 10'
or Less
2' min. when
Dim. “A” is 10'
or Less
A
CHIMNEY INSTALLATION
INSTALLING CHIMNEY SAFETY INFORMATION
You must properly install the chimney to assure safe and satisfactory performance of the fireplace. This is an important part
of the installation. Review the Chimney Installation Section thoroughly.
For your safety, some of the important things to remember in regard to chimneys are
listed below:
• Use only parts and accessories labeled for use with this fireplace.
• Use only undamaged parts and accessories.
• Enclose the chimney where it passes through the living spaces to prevent contact with
and possible damage to the chimney.
• Install firestop spacers at each ceiling level.
WARNING
• Install the proper chimney cap or chimney housing on the chimney to prevent the entry
of rain and debris into the chimney and to assure the proper venting of smoke.
• Do not use more than four elbows in the chimney.
Note: To select the proper chimney height, see Figures 12 through 16. The flue outlet must be a minimum
of 3' above the highest point where the chimney penetrates the roof and a minimum of 2' above all portions
of the building within ten feet. If the chimney is to include elbows to offset the chimney, see Chimney Offset
and Cap Installation Section. There must be at least 2" air space between all sections of the chimney and
combustible materials between floors.
Do not extend the chimney more than 90" above the roof without additional support.
Figure 13 - Proper Chimney Height
61D0008 15
Page 16
Attic Space
See Table 1 for
Roof Opening Size
Firestop Spacer SF
2"min. Clearances
to Combustibles
Model SC Chimney Cap
Storm Collar
(Including with Cap)
Flashing
(612 or 1212)
Max. Installation
Height - 86' Chimney
3' Min. and 2' Above
Any Point
Within 10'
Flue Outlet Height
Third Floor
Area
Second Floor
Area
First Floor
Area
Firestop Spacer SF
Firestop Spacer SF
15" Square Hole
in Joist (2" Air
Space Clearance
To Combustibles)
15" Square Hole
in Joist (2" Air
Space Clearance
To Combustibles)
Do not install combustible materials
below top spacer. Non-combusitble
materials such as brick or tile may
be used to trim face of fireplace. Do
not cover any part of louvered panel
and cool air inlet. Combustibles must
WARNING
not overlap the black painted face of
fireplace.
16 61D0008
Page 17
CHIMNEY INSTALLATION
LOCATING CENTER LINE
You will need to lay out, cut and frame openings through all ceilings
and the roof at the point where the chimney will pass through.
Place fireplace in planned position for installation. Unless the chimney
is to be offset, the point where the center line of the chimney will pass
through the ceiling and roof can be determined with a plumb line. See Figure 16. Drive a nail in the center point.
Note: Make sure the chimney location is well away from
ceiling and roof joists and/or anything else that might
be in the way.
Drive a long nail through the roof from underneath to mark the roof
opening center line. Make sure the nail is long en ought to go through
the roof and be seen on the rooftop. If the chimney is to penetrate a
pitched roof, the hole in the roof must be rectangular instead of square
and should be sized according to Table 1.
Center Line
to Chimney
Plumb
Line
Plumb
Bob
Actual
Center Point
Imaginary
Center
Point
Figure 16 - Dropping Plum Line
from Ceiling
INSTALLING FIRESTOP SPACER
Install the firestop spacer from beneath the ceiling as shown in Figure 17
unless the space above is attic space.
In an attic, install firestop spacer at the floor level of attic. You must have joists or headers on all four sides of the spacer.
Use a minimum of four (4) 8-penny nails to secure the spacer. See Figure 18.
Inlet Air Pipe
Flue Pipe
Floor Joist
Ceiling Joist
Inlet Air Pipe
Flue Pipe
Firestop
Header
Spacer
Firestop Spacer
Header
Chimney Section
Figure 17 - Installing Firestop Spacer
at Floor Level
Figure 18 - Installing Firestop Spacer
at Attic Level
Chimney Section
61D0008 17
Page 18
259/16"
S12
913/16"
303/4"
S18
123/16"
463/8"
S36
S48
S36
S36
S36
S18
2113/16"
563/4"
27
13
/16"
30
5
/16"
611/16"
395/16"
76
11
/16"
CHIIMNEY INSTALLATION
INSTALLING “S” SERIES CHIMNEY SPACERS
To install the “S” series chimney sections, insert the male end of the flue (the smallest diameter pipe) into the flue outlet of
the fireplace. Press down until the snap locks engage. Continue to add chimney sections on top of each other until chimney
is at least 6" above roof opening on all sides. See Figure 19.
Note: As the chimney sections are installed, check each joint to make sure it is properly locked to the
previous section.
Make outer pipe stronger by using two or three sheet metal screws placed through the area where the outer pipes overlap one
1
another. Carefully drill a
/8" diameter hole through the chimney sections. Do not drill into inner stainless steel flue pipe.
Be very careful when drilling the holes
into the outer pipe. Do not drill into
inner stainless steel flue pipe.
WARNING
Note: Dimensions may vary slightly due to manufacturing tolerances.
Figure 19 - Chimney Sections for Elbow Offsets
18 61D0008
Page 19
CHIIMNEY INSTALLATION
INSTALLING CHIMNEY SUPPORTS
Note: For a total fireplace installation of more
that 30' feet, you must use chimney
support model SCS at or below 30'
to support the weight of additional
chimney pipe.
To install the chimney support, place the crimped end of
the flue and outlet air duct portions into the last section
of chimney pipe. Push down until the outside of inlet
air duct of the chimney support overlaps and snap locks
the chimney support into the chimney section.
Nail the support straps tightly to a building frame
member or ceiling joist as shown by Figure 20. Use at
least two (2) 8-penny nails per strap.
Outer Pipe
Flue
Support
Straps
(Fasten Securely)
Firestop
Chimney
Support
Figure 20 - Installing Chimney Supports
Snap-Lock
Chimney Support
Securely to Lower
Pipes before
Fastening Support
Straps
ELBOW INSTALLATION
The following are important points that should be observed when installing elbows on the fireplace.
1. Securely nail down to the surrounding structure support straps of all elbows not installed directly on top of the fireplace.
This allows the support strap to carry the weight of the chimney above the elbow and prevents this weight from breaking
the elbow or chimney sections apart.
2. Do not use elbows in any combination that inclines the chimney more than 30° from vertical. See Figure 21.
Air Inlet Pipe
30° Elbow
Figure 21 - Elbow Supports
Flue Pipe
61D0008 19
Page 20
Rise
6'
(Maximum Offset)
CHIIMNEY INSTALLATION
Center Line
Continue Chimney to
Proper Height and
Storm Collar
Flashing
Roof
Install Round
Chimney Cap or
Chimney
Housing
Vertical Chimney
Enclosure
Support
Straps
SF Firestop Spacer
2" min. Air Space
Clearance to
Combustibles
Note: Two (2)
elbows may be
used when total
installation height
is more than 13'.
Figure 22 - Installing Chimney with Total Height of
Fireplace and Chimney 13' or More
Note: Vertical
chimney enclosure
is recommend.
Diagonal chimney
enclosure is
acceptable.
Support Strap
Center Line
Support Straps
Note: Do not let support
straps penetrate firestop
Note: Chimney
must be enclosed
in accessible
areas
Vertical Chimney
Enclosure
Support Straps
Diagonal
Chimney
Enclosure
Note: Four (4) elbows may be used when total installation
height is more than 20'. Four (4) is the maximum number of
elbows allowed.
ELBOW INSTALLATION (CONTINUED)
3. The number of elbows per chimney allowed are as follows:
If the total height of the fireplace and chimney is 13' 6"
or more, two (2) elbows may be used.
If the total height of the fireplace and chimney is 20' or
more, four (4) elbows may be used.
4. Inclined portions of chimney is often used as storage.
Enclose the inclined portions of chimney that pass through
living spaces to avoid contact with and possible damage
to chimney. Maintain minimum air space of 2" between
chimney and enclosing. See Figures 22 and 23.
5. The length of inclined portion of chimney between elbows must not exceed 6' if elbows are not supported.
The length of inclined portion of chimney between elbows must not exceed 20' if elbows are supported every 6' with
metal support straps.
6. When enclosing the elbows and inclined portions of the chimney, enclosing materials must be installed vertically to
maintain the required 2"minimum air space clearance to the chimney at the extremities of the offset. It is best that enclosing material not follow inclined portions of chimney.
SF Firestop Spacer
— 2" min. Air
Space Clearance to
Combustibles
Figure 23 - Installing Chimney with Total
Height of Fireplace and Chimney 20' or More
20 61D0008
Page 21
CHIIMNEY INSTALLATION
OFFSET INSTALLATION SEQUENCE
Determine the location and amount of offset required. Select the combinations of chimney sections and elbows required
from the Chimney Height and Offset Charts.
CHIMNEY HEIGHT CHART (FROM TOP OF UNIT OR FINISHED HEARTH)
Continued
Height
(Inches)
35
39
47
52
58
64
70
75
82
87
94
99
105
111
117
122
129
134
141
146
152
158
164
169
176
181
188
193
199
205
211
216
223
228
235
240
246
252
258
263
270
275
282
287
293
293
305
310
317
322
329
Intermediate Sections
12"18"36"48"
0
2
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
1
0
1
0
1
0
0
0
0
1
2
0
1
2
0
1
3
0
2
3
1
2
0
1
3
0
2
3
1
2
0
1
3
0
2
3
1
2
0
1
3
0
2
3
1
2
0
1
3
0
2
3
1
2
0
0
0
1
0
1
1
0
1
1
0
2
1
0
2
1
0
2
1
3
2
1
3
2
1
3
2
4
3
2
4
3
2
4
3
5
4
3
5
4
3
5
4
6
5
4
6
5
4
6
5
7
Height
(Inches)
334
340
346
Intermediate Sections
12"18"36"48"
0
0
0
1
0
1
1
3
0
6
5
7
CHIMNEY SECTIONS
WITH ELBOW OFFSETS
Elbow
Set
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
100051222203/4
Chimney Sections Total
12"18"36"48"
0
0
1
0
2
1
0
2
0
20
1
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
0
0
1
1
0
0
0
1
1
0
0
1
0
0
2
1
0
0
1
1
2
0
0
1
1
0
3
1
0
0
2
1
3
0
1
1
2
0
0
1
1
0
3
1
0
0
2
1
3
0
1
1
2
0
0
1
1
0
3
1
0
0
2
1
3
0
1
1
2
Inches
0
0
0
0
0
0
0
1
0
1
1
0
1
1
0
2
1
0
2
1
0
2
1
3
2
1
3
2
1
3
2
4
3
2
4
3
2
4
3
OffSet
41/2
10
13
151/2
151/2
22
24
28
301/2
331/2
361/2
391/2
42
451/2
48
511/2
54
57
60
63
651/2
69
711/2
75
771/2
801/2
831/2
861/2
89
921/2
95
981/2
101
104
107
110
1121/2
116
1181/2
(Inches)
Total
Inches
Rise
17
261/2
313/4
36
411/4
471/4
503/4
573/4
62
673/4
721/2
771/2
82
88
921/4
981/2
1023/4
1073/4
1131/4
1181/4
1221/2
1283/4
133
1391/4
1431/2
1431/2
154
159
1631/4
1691/2
1733/4
180
1841/4
1891/4
1943/4
1993/4
204
2101/4
2141/2
Height
352
357
364
369
376
Intermediate Sections
12"18"36"48"
0
0
0
0
0
0
1
0
1
0
STRAIGHT RUN
CHIMNEYS
Chimney support is required at
25' chimney height.
CHIMNEYS WITH
ELBOW OFFSETS
The length of the inclined portion of the chimney between
elbows must not exceed 6' when
unsupported.
The length of the inclined portion of the chimney between
elbows must not exceed 20' if
the chimney is supported at 6'
intervals using either metal support straps or an SCS chimney
support.
The SCS chimney support when
installed at a 30° angle will add
8' of rise and 4
chimney height calculations.
5
/8" of offset to the
2
3
1
2
0
6
5
7
6
8
61D0008 21
Page 22
79/16"
71/4"
22
1
/16"
15"
30°
A
A
3' min.
Flue Outlet
Height
Flue Outlet
Height
Flue Outlet
Height
3' min.
2' min. when
Dim. “A” is 10'
or Less
2' min. when
Dim. “A” is 10'
or Less
A
CHIIMNEY INSTALLATION
OFFSET INSTALLATION SEQUENCE
(CONTINUED)
1. Install the first SE30 elbow by placing the extended flue into the mating
part of the fireplace or chimney section. Push down until the outside of
inlet air duct of the elbow overlaps. Snap lock the elbow into the fireplace
or chimney section.
2. Nail the support straps to the framing member with a minimum of two (2)
8-penny nails per strap.
Chimney
3. Install the sections of pipe between elbows until the proper number of
Center Line
chimney sections have been installed.
4. Install the second elbow to return the run of the chimney to vertical.
Figure 23 - SF30 Firestop
Spacer
5. Nail the support straps of the second elbow to a building frame member.
6. Continue installing the vertical portion of the chimney. See Figures 22
and 23.
Note: If the inclined portion of the chimney passes through a floor or ceiling, an SF30 firestop spacer should
be installed to provide the firestop and support required. Be sure proper spacing in maintained
between the chimney and combustibles. See Figure 23.
CHIMNEY CAP INSTALLATION
MODEL SC CHIMNEY CAP
Note: The proper chimney height is important to assure proper draft and safety.The chimney cap must
extend the flue outlet 4" above the top of the last section of chimney. Keep this mind when
determining the proper height for the chimney. The chimney should not be extended more than
90" above the supporting roof structure without additional support. In the case of an “A” frame
type construction or other steep pitch roofs that require more than 90" of chimney above the roof,
attach a support to the chimney at the 90" level that is strong enough to support a wind load of
31/8 pounds for each inch the chimney extends above 90". The flue outlet must be a minimum of 3'
above the point where in penetrates the roof. See Figure 24.
Figure 24 - Proper Chimney Height
22 61D0008
Page 23
181/2"
36"
CHIMNEY CAP INSTALLATION (CONTINUED)
Be careful to avoid electrical shock
hazard when contacting wires to the
metal chimney components.
CAUTION
1. Extend the regular chimney sections until the top of the chimney is 4"
below the total flue height desired. Do not snap the last section of inlet
air duct or largest diameter pipe in place until Step 3 is completed.
2. Remove the shingles from around the chimney so that the flashing
may be installed. Install the upper part of the flashing under the
shingles.
3. Set the flashing on the roof. Scribe a line around the flashing. Cut
1
/4" below the scribed line. This should increase the diameter of the
flashing outlet enough to allow the flashing to be placed over the
chimney. See Figure 25.
CHIIMNEY INSTALLATION
Flashing
Cut Off 1/4"
below Scribed
Line
Figure 25 - Cutting Off Top of the
Flashing
Note: SCL chimney cap is the same
as SC chimney cap except that the
SCL cap is a longer telescoping pipe
used in special installations (i.e. chase
installations)
4. Snap the last section of inlet air duct in place. Slide flashing over the
chimney. Check for minimum clearances. Adjust chimney if necessary to make minimum clearances.
5. Nail the flashing securely in place with eight (8) nails.
6. Seal crack between top of flashing and chimney with mastic. Leave
some extra mastic at this area to be used in step 8.
7. Place the storm collar around the chimney and put collar
together like a belt in belt loops. With the loops facing
up, slide the end of collar under the two loops on the
other end. Overlap the ends of the collar until it is tight
against the chimney. Bend the free end of the collar back
over the loops to hold the storm collar securely together.
Trim off the excess ends of the storm collar.
8. Slide storm collar down snugly against the flashing until
the excess mastic left in step six is forced up into crack
between the storm collar and chimney. This will make the
joint between the flashing and the chimney watertight.
See Figure 26.
9. Place chimney cap into matching parts of the last chimney section. Push chimney cap down until the brackets on the
bottom of the chimney cap sits on the chimney pipe. Punch or drill
where specified on the brackets. Fasten chimney pipe down with the No. 8 screws provided. Note: Do not penetrate
the inner stainless steel pipe while installing the screws.
Figure 26 - Installing Storm Collar
Use pliers and wear gloves when
handling the storm color The edge of
the storm color is sharp. If you are not
careful, you could cut your hands.
CAUTION
1
/8" diameter holes in the inlet air duct (chimney pipe)
Model SC
Chimney Cap
Apply Mastic
Here
Storm Collar
Flashing
and Chimney Cap
10. Check all the parts of the fireplace, chimney and chimney termination cap. Make sure none have been damaged or bent
during installation. Check to see that all parts have been properly installed.
Note: The metal used for chimney cap has a rust-protective coating but the cut edges of the parts are not
61D0008 23
protected. Detergent-wash and paint exposed parts of chimney cap with galvanized primer paint.
This will prevent rusting and rust staining of nearby structures.
Page 24
3"min.
Overlap
10"max. Space between
Chimney Section and
Chase Cover
CHIIMNEY INSTALLATION
CHIMNEY CAP CHASE INSTALLATION
The preinstalled chimney sections must be no more than 10" below the top of the chase. Plan the installation so that either
a 2' or 3' chimney section will be used for the top section. This is necessary to completely install inlet air telescope and
chimney cap into the top section.
Note: When two fireplace chimneys are terminated
Be careful around electrical wires
to avoid the electrical shock hazard
of contacting the wires with the
metal chimney components.
WARNING
1. Extend the chimney sections until the top of the chimney is not more than 10" below top of the chase.
2. Center the hole in the chase cover over the chimney. Lance and form chase cover overhang over the chase. Secure chase
cover overhang with nails. The chase cover overhang keeps water from seeping under the chase cover. If two or more
chase cover overhangs are to be used on the same chase, solder the chase covers together to form watertight seams.
3. Place the inlet air telescope inside the hole in the chase cover. Lower inlet air telescope down into the mating pipe of
the chimney until flange on the telescope section rest on flange of the chase cover overhang.
Note: All telescoping sections should extend a minimum of 3" inside the mating chimney pipes.
above the same chase, the centers of the chimney caps
should be at least 24" apart to help prevent smoke from
fireplace in use from being drawn down the chimney of
fireplace that is not in use. Additional spacing between
caps or staggering the height of the caps will also
help.
4. Place SCL or SQL8 chimney cap into matching duct telescope and flue telescope of the last chimney section. See Figure
27. Lower the cap until the brackets on the bottom of the chimney cap rests on the raised flange of the flat flashing.
1
Punch or drill
/8" diameter holes in the raised flange of the flat flashing. Fasten cap to the flashing with the No. 8 screws
provided.
5. Check all parts of the chimney and chimney cap. Make sure none have been damaged or bent during installation. Check
to see that all parts have been installed properly.
Note: The metal used for the chimney and chimney cap has a rust-protective coating but the cut edges of
the parts are not protected. Detergent-wash and paint exposed parts of the chimney and chimney cap
with galvanized primer paint. This will prevent rusting and rust staining of nearby structures.
Chimney Cap Support Brackets
Screw
Maintain Chimney
System Air Space
Clearances to
Combustibles Above
Roof Line
Inlet Air Telescope
Chase
Figure 27 - Installing Chimney Cap Chase
24 61D0008
Roof
Page 25
8'max.
OUTSIDE COMBUSTION AIR PRECAUTIONS AND RECOMMENDATIONS
COMBUSTION AIR
1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner.
Locate assembly above the snow line to prevent blockage by snow accumulation.
2. Never mount the combustion air inlet assemblyin a garage or storage area where combustible fumes such as gasoline
might be drawn into the fireplace.
3. Combustion air can be drawn from the crawl space under a house when an adequate supply of air is provided by open
ventilation.
4. Do not take combustion air from attic space or garage space.
5. Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly.
These conditions increase the resistance to the free flow of air through the duct. See Figures 28 through 31 for methods
of installing the outside air for combustion assemblies.
Continued
Plate
Basement
Wall
Above
Snow
Level
Ground
Level
Termination Cap
Firestop Spacer
Figure 28 - Basement Installation
Inlet Grill
in Soffit
(Overhang)
Do not take combustion
air from attic space or
garage.
CAUTION
Figure 29 - Concrete Slab Installation
(Optional Outside Air Runs)
61D0008 25
Page 26
OUTSIDE COMBUSTION AIR PRECAUTIONS AND RECOMMENDATIONS
COMBUSTION AIR (CONTINUED)
Second Floor
Do not take combustion
Firestop
Spacer
air from attic space or
garage.
CAUTION
Duct Extended
to Miss Joist
To Outside Wall
Figure 30 - Installation Above Basement or
Crawl Space
Inside Wall
One Wall,
Inside Room
Outside
Wall
Figure 31 - 45° Corner Installation on Slab Floor
26 61D0008
Page 27
OUTSIDE COMBUSTION AIR PRECAUTIONS AND RECOMMENDATIONS
The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside
combustion air to one side of the fireplace. Use the model AK4 combustion air kit.
MODEL AK-4 COMBUSTION AIR ASSEMBLY
1. Remove the cover plate from the 4" outlet opening location on the left or
right outside of the fireplace.
2. Place the insulation ring between the AK-4 starting collar and fireplace wall.
3. Place the starting collar (4") into the hole on the side of fireplace. Fasten it in place with the four sheet metal screws
provided. See Figures 32 and 33.
Note: The air starting collar extends through the fireplace outer wrap. When the air starting collar is
securely attached, it will form a seal against the fireplace wall.
DO NOT remove the
cover if the outside air
will not be connected.
WARNING
4. Attach outside duct to starting collar with duct clamp or screws.
Left Side of
Fireplace
Shorter End
of Air Starting
Figure 32 - Attaching Outside Air Starting Collar
and Insulation Ring to Left Side of Fireplace
5. Cut a 6-inch diameter opening for model AK-4 in the outside
wall covering where the outside vent is to be located. See
Figure 34.
6. Select and cut a piece of duct long enough to attach to the
fireplace and stick out at least 3" beyond the face of the wall
to which the AK-4 inlet air vent will be attached. Cut duct
with a standard pocket knife. See Figure 33.
Insulation Ring
AK-4 Starting
Collar
Sheet
Meal
Screws
Collar
6" Diameter
Duct
Extending
3"min.
See Figure 33.
Screws
Left Side of
Fireplace
Figure 33 - Attaching Outside Duct
to Starting Collar
Hole
Air Starting
Collar
Duct
Screw
Nail
Holes
Use FP-4 U duct for maximum efficiency
and safety. Do not use a combustible
duct. Always use UL Listed Class 0 or
1 duct material.
WARNING
61D0008 27
AK-4 Inlet
Air Vent
Figure 34 - Combustion Air Assembly for
Model No. AK-4
Screws
Continued
Page 28
OUTSIDE COMBUSTION AIR PRECAUTIONS AND RECOMMENDATIONS
MODEL AK-4 COMBUSTION AIR ASSEMBLY (CONTINUED)
7. If the duct is the insulated type, push the insulation back from one end of
the duct approximately 2". See Figure 35.
8. Slip the exposed end of the duct over the starting collar on the fireplace.
9. Using the sheet metal screws provided, secure the duct end to the collar
attached to the fireplace.
Duct
Connector
Approximately
2"
10. Nail or screw the combustion air assembly to the surface of the wall.
Note: If the wall covering is brick or stone, use appropriate masonry
fasteners. Mount combustion air assembly with “TOP’”
upward to prevent cold air from entering through the wall. If
necessary, splice the duct. Use a model 403-duct connector
to splice duct sections.
Figure 35 - Installing Duct
Connector 403
INSTALLING MODEL 403 DUCT CONNECTOR
1. Push insulation back approximately 2" from the end of each duct.
2. Slip each duct over duct connector until an equal length of connector extends into each duct.
3. Place duck clamp over the end of each duct. Tighten duct clamp down snuggly.
4. Push insulation back into place and over duct clamp.
GAS APPLIANCE INSTALLATION
Improper installation or operation of a gas appliance in this fireplace can allow
unburned gas to leak out which will cause a fire or explosion hazard, or the release
of poisonous carbon monoxide into the dwelling which can cause serious injury or
death to its inhabitants.
DANGER
Insulation
Duct Clamp
To reduce these risks to a minimum, read and follow the following important notices and instructions carefully.
1. The provision for a gas line is intended for connection to a decorative gas appliance which has an automatic shutoff device
and complies with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSIZ21.60. If a decorative gas appliance is installed, it must be installed in accordance with the National Fuel Gas Code, ANSIZ223.1.
28 61D0008
Keep fireplace damper fully
opened at all times when
using a decorative VENTED
gas appliance.
WARNING
Continued
Page 29
GAS APPLIANCE INSTALLATION
If an unvented gas appliance is installed in the fireplace, the gas appliance must
only be operated with the fireplace glass door fully open (if included). Only unvented
gas log sets which have been found to comply with the standard for unvented room
heaters, ANSI/IAS/AGA Z21.11.2 are to be installed in this fireplace.
CAUTION
Do not operate an
unvented gas log set in
this fireplace with the
chimney removed.
WARNING
2. An approved gas shut off valve must be located outside the fireplace in an area accessible to the users of the fireplace.
3. All gas piping and fitting must be either steel or malleable iron. Unions must be of the ground joint type.
4. Some code authorities prohibit or place restrictions on the use of gas appliances in fireplaces. Check with local code
authorities before proceeding with installation.
5. The gas appliance and all connecting gas piping must only be installed by a licensed gas appliance installer. See Figure 36 for the gas line opening dimensions on the fireplace.
6. The installer of the fireplace and gas appliance must describe the operation of the fireplace and appliance to the people
who will be operating them and leave all instruction manuals with the operator of the appliance.
Maintain ½"min. Air
Space Clearance to
Combustibles for Gas
Line Out to 4" from
Side of Fireplace
Combustive Materials May Be
Located at Zero Clearance to Gas
Line Beyond 4" from Fireplace Side
Figure 36 - Gas Line Opening Dimensions
Outer Fireplace Wrap
Inner Fireplace Wrap
Side Brick
28"max.
Fireplace
Opening
Gas Line
Access Tube
Hearth Brick
61D0008 29
Page 30
INSTALLING GAS APPLIANCE
PASSING GAS LINE THROUGH FIREPLACE WALL
1. Locate recessed area in side brick side liner.
2. Lightly tap recessed area with a hammer until a round hole is
tapped out. See Figure 37.
3. Remove the two (2) screws that hold cover plates on jacket
wrap. Discard cover plate.
4. Install the gas pipe through the tube between the firebox and
jacket.
5. Attach the gas appliance to the gas pipe according to the appliance makers instructions.
6. Pack insulation around the pipe to prevent air flowing through
the tube either into or out of the firebox for proper seal.
1. Turn gas off at the appliance.
2. Turn the gas on at the cut off valve.
3. Test the gas line connections for leaks with soapy water solution or a liquid leak
detector. DO NOT USE A MATCH OR OTHER FLAME SOURCE TO CHECK FOR GAS
WARNING
LEAKS. If a gas leak is detected, turn the gas off immediately. Fix the leak.
Back Brick
Liner
Figure 37 - Hole in Side Brick Liner
Side Brick
Liner
Hole
7. Follow the instructions provided by the manufacturer for testing and adjusting gas line.
30 61D0008
Page 31
8"
47"
54"
1
1
/2"
max.
12"
12"
max.
42
1
/2"
TRIM AND MANTEL INSTALLATION FOR GAS APPLIANCES
Mantel Trim Installation (Unvented Gas Appliances Only)
The fireplace face may be left exposed or trimmed. If trim is installed, fasten it securely to face of fireplace. Trim materials
must not extend closer than 3/8" to the vertical edge of fireplace opening if you plan to use glass doors.
1. Install hood on fireplace with mantels 12" from the
opening of fireplace. Mantel may be no more than
12" deep. Combustible framing members may be
placed across top spacers. See Figure 38.
2. Combustible mantel and/or trim may be installed
within shaded area in Figure 39. Use only noncombustible materials below top of spacers and
behind front face.
Hood (p/n 075629) must be installed when
mantel is 12" from fireplace opening.
Note: Glass doors must be removed when
using hood.
WARNING
Note: No
combustible
materials
within 12"
of opening.
2¾" Hood
(p/n 075629)
Figure 38 - Locating Mantel 12" from Opening
when Using Hood
Top Spacers
Shaded
Area
Non-combustible
Wall Board
Figure 39 - Placement of Combustible
Mantel and Trim without Hood
Note: These instructions are for acceptable combustible mantel location in GAS APPLIANCES ONLY. See
61D0008 31
Figures 40 through 41 for acceptable combustible mantel locations for wood burning fireplaces.
Page 32
12"max.
A
B
TRIM AND MANTEL INSTALLATION FOR WOOD BURNING FIREPLACES
• The fireplace face may be left exposed or trimmed. If trim is installed, fasten it securely to face of fireplace. Seal any
cracks between trim material and face of fireplace. Cracks can cause a fire and prevent fireplace from working properly.
• Place wall ties in mortar joints of masonry trim. Fasten wall ties to face of fireplace with sheet metal screws.
• Use only non-combustible materials below top of spacers.
Combustible
Wallboard
Area to Be
Figure 40 - Spacer Location
Non-Combustible
Trim
Sealed
LOCATING FRONT AND SIDE CLEARANCES
Seal any spac e betwe en face of
fireplace and non-combustible facing
material. Failure to seal this crack is a
possible fire hazard and will void the
warranty.
WARNING
Do not cover or restrict
side vent areas with
surround or trim materials
WARNING
LOCATING MANTEL
Maximum depth of mantel is 12"
A = 6½" - Minimum from top of fireplace opening to bottom
of any combustible trim material sticking out no
more than 1½" beyond face of fireplace
To find front clearances, extend a line from back corner of
unit to 4" in front of fireplace face and 1" outside screened
opening. Combustible materials may be placed within shaded
areas. Note: Do not let combustible materials overlap
black painted surface more than 1/8". See Figure 41.
Trim may butt against side walls of fireplace. The other 3 walls
must have ¾" clearances.
Extended Line
¾"
Combustible
Material
within Shaded
Area
1" Reference
Figure 41 - Front and Side Clearances
4" Reference
Separation
0" Clearance
to Front Side
Walls
B = 12" - Minimum from top of fireplace opening to bottom
of combustible trim material sticking out more
than 1½" from top of fireplace opening
Combustible
Wallboard
Figure 42 - Locating Mantel
Combustible
Mantel
Non-
Combustible
Surround Trim
Top of
Fireplace
Opening
32 61D0008
Page 33
M1M2
FAN
ASSEMBLIES
CORD SET
120V, 50HA
GROUND
TO FUSE
OR CIRCUIT
BREAKER
SWITCH
(SPST)
GLASS DOOR INSTALLATION
This fireplace has been tested and listed for use with optional Model GD36BA, BD36PBA, GD36SSA, GD42BA,
BD42PBA, and GD42SSA glass doors. For installation of glass doors, see the instructions provided with the doors.
FAN ACCESSORY
The mo del 400BWBCA, 400BWBCIA,
500BWBCA, and 500BWBCIA fireplaces may
be equipped with a Model FA2A fan accessory.
If the fireplace is to be equipped with the FA2A
fan at anytime, the junction box assembly must
be installed on the fireplace during fireplace
installation. See Figures 43 through 45. If
junction box is not installed at this time, wall
finishing materials must be removed to gain
access to the side of the fireplace to install
junction box later.
Note: A rectangular switch knockout is
provided on the lower right hand
face of the fireplace.
Switch
Knock Out
Attach Each
Fan with Two
(2) Screws
Here
Front of
Fireplace
Firebox
Bottom
Fan Installation
Fireplace Bottom
Figure 44 - Blower Location (Side View)
Opening for
Figure 43 - Blower Location
(Faces Back of Fireplace)
Junction Box
Cover
Fan
61D0008 33
Figure 45 - Wiring Diagram
Page 34
FIREPLACE OPERATION
HOW TO BUILD A BETTER FIRE
Fireplace damper must
be fully opened when
using a gas appliance.
WARNING
See Gas
Appliance
Installation for
more guidelines.
ADVANTAGES OF A WOOD BURNING
FIREPLACE
These are practical and ecological advantages of using wood
as a fuel. Also to be considered is the aesthetic appeal. Most
of us consider a wood fire with nostalgia. We enjoy the aroma
and find the flickering light of a cozy hearth reminding us of
things past. Wood has a low ash content. The little ash that
remains after burning is useful in home gardening as a fertilizer and soil conditioner.
WHICH WOODS ARE BEST?
Each wood species offers something different in aroma or
heat value. You should consider your needs and desires before
building your fire.
Softwoods, like pine, spruce and fir are easy to ignite because
they contain a lot of resin. However, a fire built entirely of
softwoods burns out quickly. You also must add wood more
often. While a softwood fire is not too desirable for a long
evening, itʼs fine in the morning when you want quick warmth
or late in the evening when you want a fire that will burn out
before you go to bed.
On occasion when a longer fire is desired, itʼs best to combine
softwoods with the heavier hardwoods such as ash, beech,
birch, maple, oak and hickory. Hardwood burns slower, with
shorter flames, and produce steady, glowing coals.
For the most pleasing aroma, burn the wood of fruit trees
such as apple and cherry, or nut trees such as beech, hickory
and pecan. This wood is generally more expensive, but a
little combined with other wood goes a long way. Start your
fire with a mixture of softwood and hardwood. Add some
fruit or nut wood for nostalgic aroma. Since most woods
will not burn well when freshly cut, the wood you purchase
should be reasonably dry. Purchase logs that will fit when laid
across your grate. Ask that the larger, heavier logs be split.
Kindling should be short, easily split lengths of softwood,
lumber yard or mill scraps, or twigs and branches gathered
from your yard.
The first three fires should be of moderate size. This lets the
fireplace adjust to the heat and the bricks to cure.
First, make sure your room is well ventilated, your damper
open and the flue is unobstructed. Then make sure your wood
is dry and seasoned. Unseasoned wood burns poorly. If you
use unseasoned wood with poor ventilation or an obstructed
chimney, smoking could occur.
If your fireplace is equipped with an outside combustion air
assembly, open the combustion air inlet by pushing upward
on the lever located above the firebrick on the left side of the
firebox.
Never use gasoline, gasoline-type
lantern fuel, kerosene, charcoal lighter
fluid, or similar liquids to start or
“freshen up” a fire in this fireplace.
Keep all such liquids well away from
the fireplace while it is in use. Use
WARNING
of this fuel ca n ca us e a se ri ou s
explosion.
Prepare your fire by placing two logs on the iron grate or fire
basket, and laying the tinder between them. Tinder may be
dry scrap paper, twigs or bark. On top place a small handful of twigs or split softwood kindling. Place more dry logs
over this base. Keep logs close together, as narrow air spaces
between them promote better drafts. Heat reflected between
adjacent surfaces aids in raising and maintaining combustion
temperatures.
Youʼll need a minimum of three logs, preferably four, to
make a good fire. Add kindling and new logs as needed to
rekindle a dying fire. New logs should be added at the rear
grate after raking the coals toward the front. Note: Do Not Overfire the Fireplace. Overfire conditions happen when
you use large amounts of kindling, building scraps or other
improper fuels.
Ashes are important because they form a bed of glowing
coals. Let ashes build up to 1" to 2" on the bottom of the
grate. Excess ashes can be used to check a flaming fire or to
“bank” your fire. Cover the logs with ashes. A “banked” fire
will hold glowing coals for 8-10 hours, thereby saving a fire
for later use.
34 61D0008
Page 35
FIREPLACE OPERATION
WOOD VS. FOSSIL FUELS
Compared to fossil fuels, a full cord of dry hickory weighs
about two tons and is approximately equal in heating value
to a ton of hard coal. On a per pound basis, heavy hardwoods
have about half the heating value of coal. The table below
shows the relative densities and heat values of a variety of
dry woods. Varieties at the top of the list (Dogwood) burn
longer and those near the bottom (White Pine) ignite and
burn quicker. A combination of both light and heavy wood
is desired.
SPECIES VALUE DENSITY HEAT
Dogwood .70-.79 100-107
Hickory .70-.74 100
Oak .60-.73 86-99
Black Locust .69-.70 95-98
Beech .64-.66 89-91
Hard Maple .58-.65 83-88
Birch .55-.64 79-86
Apple .58-.62 83-84
Ash .57-.61 81-82
Southern Pine .51-.60 73-81
Elm .50-.59 71-80
Cherry .50-.52 70
Douglas Fir .45-.51 64-69
Spruce .41-.44 59
Redwood .33-.40 47-54
White Pine .35-.37 50
A FEW WORDS OF CAUTION
Do not burn plastics, poison ivy twigs and stems and chemically treated woods such as discarded poles and railroad ties
in your fireplace. These create air pollution and can cause
extreme irritation for some people.
Use hemlock, spruce, juniper and other resinous woods with
caution. They contain moisture pockets which, upon heating,
“pop” with considerable vigor.
Always use a fire screen. Always “bank” a fire (or at least push
all unburned fuel to the rear of the grate) before leaving a fire
unattended. Do not use this fireplace as an incinerator.
The termination of the chimney above the roof is exposed to
wind, cold, and pressure changes. These and other environ
mental conditions may make it hard to get a sufficient chimney
draft at times. At other times the draft may be sufficiently
disrupted and cause smoke to spill from the fireplace opening.
If problems with chimney draft occur, help start chimney draft
before you build a fire by holding a piece of burning paper
near the flue opening at the top of the firebox to preheat the
chimney. If smoke spills from the fireplace opening after the
fire is burning, open a window on the up wind side of the house
that is far enough away form the fireplace that the wind will
not blow across the fireplace opening. Push burning wood as
near the back of the fireplace as possible. If your fireplace has
glass doors, close them.
IMPORTANT: Do not leave children or physically or
mentally handicapped, or senile persons alone with a
burning fireplace.
-
61D0008 35
Page 36
MAINTENANCE
FUEL STORAGE
Wood can be dried sufficiently for burning within a few weeks
if protected form rain in a low humidity area. It is better to
cut wood and allow it to dry for a year. In all cases, the wood
should be stacked so that both ends of the sticks are exposed
to the air and protected from rain. The drier the wood, the
more usable heat produced by the fire and less likely rapid
accumulation of soot and creosote within the chimney is to
occur. See Chimney Maintenance for information on the
hazards of soot and creosote accumulation. Small quantities
of wood required for fire tending must be kept at least 30"
from the fireplace.
DISPOSAL OF ASHES
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on
a noncombustible floor or on the ground well away from all
combustible materials until they are finally disposed of. If the
ashes are buried or locally dispersed, they should be kept in
the closed container until all cinder has thoroughly cooled.
Ashes should never be placed in a container with combustible
materials.
CHIMNEY MAINTENANCE
Creosote, Formation and Need for Removal
hen wood is burned slowly, it produces tar and other organic
vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue
accumulates on the flue lining. When ignited, this creosote
makes an extremely hot fire.
Note: The chimney should be inspected at least twice
a year during the heating season to determine
if a creosote buildup has occurred. If creosote
has accumulated it should be removed to
reduce the risk of a chimney fire.
The chimney cap can be removed for inspection, maintenance
and cleaning by removing three screws from the support legs
and lifting upward.
When the fireplace is new, inspect the chimney often and clean
the chimney any time creosote is seen on the flue walls. Once
you see a pattern of how often creosote is accumulating, you
can determine how often the chimney should be inspected.
Also changes in the outside environmental conditions such as
temperature and humidity or changes in the operation of the
fireplace can lead to rapid buildup of soot and/or creosote.
Have a a qualified and reputable chimney sweep clean the
chimney or remove creosote or soot with brushes on wooden
or fiberglass poles. Note: Do not use metal pipes,
chains, wires, etc., to clean the chimney. They can
scratch the surface of the stainless steel flue. This
will shorten the life of the flue and provide a rough
surface for soot particles to attach to.
Be sure to cover nearby furnishing and arrange some method
of catching soot and creosote particles that may fall during
the chimney cleaning process. If glass doors are installed on
the fireplace, they should be closed. Extra caution must be
used to avoid damage to the flue damper during the cleaning
process.
In addition to checking and cleaning the chimney on a regular
basis, be sure to inspect the chimney before starting a fire at
the beginning of each heating season. Make sure the chimney
is clear from any accumulation of soot, creosote or any other
debris. Make sure all joints are intact.
Martin Hearth and Heating does not recommend chemical
cleaners because some may contain elements that corrode the
metal parts of the chimney or fireplace.
FIREPLACE MAINTENANCE
At the end of each heating season or when the fireplace will not
be in use for an extended time, the ashes should be removed
and the hearth area should be swept clean. The slow absorption
of moisture into the ashes over a long period of time could
corrode metal fireplace parts.
At the beginning of each heating season, always operate the
flue damper and make sure it has not become stuck from soot,
creosote, etc.
Keep the lower and upper grille panels clean and free from
dirt and lint accumulation at all times to get the maximum
efficiency from your fireplace.
As you use the fireplace, expansion and contraction will cause
minor cracking of the hearth, back and side refractory mate
rials. This is normal and unavoidable. If the cracks become
large enough or parts dislodge and metal behind the refractory is exposed, the refractory panels should be replaced with
new panels. Obtain these panels Martin Hearth and Heating
fireplace dealer.
GLASS DOOR MAINTENANCE
For glass door maintenance, see instructions provided with
the glass doors.
-
36 61D0008
Page 37
CHECKLIST OF DO’S AND DON’Ts
DO’S
MAINTENANCE AND SAFETY
1. Do check with local building officials to be sure the installation of the fireplace complies with all building codes
and requirements. Obtain required building permits. Do
plan your installation with safety as you primary consideration.
2. Do use only the prescribed material and parts for the
installation of the fireplace.
3. Do insulate the exterior walls surrounding the fireplace
to prevent excessive heat loss from the fireplace.
4. Do trim the face of the fireplace only with non-combus
tible materials.
5. Do attach the non-combustible face trim material firmly
to the face of the fireplace.
6. Do block in or fasten the fireplace to prevent the possibil
ity of the fireplace shifting out of position.
7. Do connect the air circulation blower to a properly
grounded and fused electrical circuit.
8. Do enclose the chimney where it passes through living
spaces or spaces accessible for storage purposes to prevent contact with and possible damage to the chimney.
9. Do install firestop spacers at each ceiling level when the
chimney is installed in a multistory building.
10. Do install the proper chimney cap or chimney housing
on the chimney to prevent rain and debris from entering
the chimney.
11. Do keep all flammable liquids, gases and pressurized
containers away form the fireplace.
12. Do check the fireplace for proper adjustment and opera
tion before leaving it unattended for long periods of
time.
13. Do inspect and clean the fireplace chimney regularly.
14. Do keep the fire screens closed when the fireplace is left
unattended to minimize the danger of sparks popping out
of the fireplace.
-
15. Do use the grate furnished with and for this fireplace.
16. Do start a fire only with paper, kindling or solid composi
tion fire starters specifically designed for starting a fire.
The use of liquid fire starter can cause an explosion within
-
the fireplace.
17. Do place all ashes in a metal container with a tight fitting lid and place them on a noncombustible surface well
away from other combustible materials until they have
completely cooled.
18. Do store your fuel supply at a distance equal to or greater
than the spacing recommended for combustible materials
from the fireplace.
19. Do build fires of moderate intensity in the fireplace for the
first three fires to allow materials to adjust and cure before
being subjected to the intense heat of a large fire.
-
-
If not installed, operated and maintained in accordance with the manufacturers
instructions, this product could expose you to substances in fuel or from fuel combustion
which can cause death or serious illness and which are known to the state of California
to cause cancer, birth defects or other reproductive harm. Also, operation, installation
and servicing of this product could expose you to airborne particles of glass wool fibers
WARNING
known to the state of California to cause cancer through inhalation.”
61D0008 37
Page 38
MAINTENANCE AND SAFETY
DON’Ts
1. Donʼt allow other installations or operation considerations
to take priority over safety considerations.
2. Donʼt attempt to use the fireplace until the installation is
complete.
3. Donʼt use unlisted parts and accessories with the fireplace
except for special flashings fabricated locally.
4. Donʼt use damaged parts or accessories with this fire
place.
5. Donʼt install the fireplace in an exposed or uninsulated
area.
6. Donʼt install the fireplace over carpeting.
7. Donʼt install the fireplace on a poorly constructed base
or fail to fasten down or attach the fireplace to prevent it
from shifting out of position.
8. Donʼt create or allow a crack to develop between the
metal face of the fireplace and noncombustible trim.
9. Donʼt use power blowers or air circulation systems with
this fireplace that are not specifically recommended by
Martin Hearth and Heating.
10. Donʼt connect accessory air circulation blowers to
improperly fused or ungrounded electrical circuits.
11. Donʼt install the fireplace where flammable or explosive
liquids or vapors are likely to be present.
12. Donʼt neglect all the considerations mentioned in this
manual concerning clearances to combustibles, spacing from obstructions and proper chimney height when
selecting the location and installing the chimney.
13. Donʼt allow insulating materials to contact the chimney.
14. Donʼt neglect to apply caulking or mastic to the required
joints of the flashing and between the flashing roof.
15. Donʼt dry clothing or other articles near the fireplace.
16. Donʼt store or place flammable liquids, gases or pressur
ized containers near the fireplace.
17. Donʼt neglect to instruct all responsible persons in the
proper and safe operation of the fireplace.
18. Donʼt fail to instruct all persons, especially children and
-
elderly persons, concerning the hazards of improper operation and unauthorized tampering with the fireplace.
19. Donʼt use this fireplace to burn paper, cardboard, or other
debris.
20. Donʼt neglect to inspect and clean the chimney regularly.
21. Donʼt operate the fireplace with the glass fire screen doors
partially open. The doors should always be fully open or
fully closed.
22. Donʼt use gasoline, kerosene, engine oil, charcoal lighter
fluid or other flammable liquids to start or intensify a fire.
Using these and similar materials can cause an explosion
within the fireplace.
23. Donʼt store fuel supply closer to the fireplace than the
minimum spacing required for combustible materials.
24. Donʼt subject the fireplace to the intense heat of a large
fire the first three times the fireplace is used, but build
moderate fires to allow the materials to cure and adjust.
25. Donʼt clean the chimney with metallic devices or chemical
cleaners.
26. Donʼt use the fireplace or chimney for venting wood or
coal burning heaters or inserts unless approved in writing
by Martin Hearth and Heating.
27. Donʼt put combustibles within 24 inches of the fireplace
opening
-
38 61D0008
Page 39
1
2
3
4
5
6
1
2
3
4
5
6
REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER
Failure to position the parts in accordance with these diagrams or failure to use only
parts specifically approved with this appliance may result in property damage or
personal injury.
WARNING
61D0008 39
Radiant Models:
400BWBA 400BWBIA 500BWBA
500BWBIA
Page 40
REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER
clear glass
1GD36BAOptional 36" black bifold glass door kit. black finish frame; tempered clear glass
1GD36SSAOptional 36" stainless bifold glass door kit; stainless finish frame; tempered clear glass
1GD42PBAOptional 42" polished brass bifold glass door kit; polished brass finish frame; tempered
clear glass
1GD42BAOptional 42" black bifold glass door kit; black finish fram; tempered clear glass
1GD42SSAOptional 42" stainless bifold glass door kit; stainless finish frame;tempered glass is clear.
2SCSChimney support (Required when chimney height exceeds 30')
3SE30Elbow offset/return package containing two 8" diameter 30° elbows
46120 to 6/12 variable pitch roof flashing; one 612 flashing required with SC round chimney cap
on 0 to 6/12 pitch roof
4 12126/12 to 12/12 variable pitch roof flashing. One 1212 flashing required with SC round
chimney cap on 6/12 to 12/12 pitch roof
5SCRound chimney cap for contemporary installation; includes storm collar
6SF141/2" firestop spacer. One required at each ceiling or floor level
7H165216"x52" hearth extension for protecting floor against sparks and radiant heat
7H206620"x66" hearth extension for protecting floor against sparks and radiant heat
8AK44" diameter outside combustion air kit; allows air from outside to enter fireplace (For
residential homes)
8AK66" diameter outside combustion air kit; allows air from outside to enter fireplace (For
manufactured homes)
9FP4U4" diameter x 8' long flexible uninsulated combustion air duct (Use with AK4 kit)
9FP6U6" diameter x 8' long flexible uninsulated combustion air duct (Use with AK6 kit)
104034" duct connector for splicing FP4U ducts; includes one connector and two clamps
106036" duct connector for splicing FP6U ducts; includes one connector and two clamps
11FA2AOptional fan kit, with switch; FA2 fan installs under firebox bottom; removal of brick is
required; install JB1 junction box at the time the fireplace is installed if the FA2A Fan is to
be installed at any time.
12R367236"x72" flat chase flashing with single flue hole
12R488448"x84" flat chase flashing with single flue hole
13CF8Terra Cotta masonry-look termination chimney cap for chase installation; use with VFK
flashing kit
14S4848" long x 8" diameter chimney flue section
14S3636" long x 8" diameter chimney flue section
14S1818" long x 8" diameter chimney flue section
14S1212" long x 8" diameter chimney flue section
40 61D0008
Page 41
REPLACEMENT PARTS
REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER
1
3
4
2
5
7
6
13
11
8
9
12
10
14
REPLACEMENT PARTS (NOT SHOWN)
ItemDescription
SCLRound chimney cap with telescoping pipe and storm collar. (For chase installation)
SQ8Square termination chimney cap (181/2" x 181/2") for chase installation (Use with VFK flashing kit)
SF30Firestop spacer for 30° chimney incline through ceiling or floor
S88" diameter double-wall telescope pipe for use with LFSQT chimney cap
LFSQTSquare shroud termination chimney cap for chase installation; use with S8 telescope pipe and
VFK flashing kit (Minimum chase top dimensions: 26"x26")
SPCPyramid shroud termination chimney cap for chase installation
H36Hood for heat deflection; may be installed on fireplace in residential type home to reduce the
recommended clearance to a combustible mantel; do not use with glass doors.
VFKVent flashing kit consisting of adjustable radiation shield with spacer brackets and fasteners
(For venting a field-constructed flashing assembly on a combustible chase top)
61D0008 41
Page 42
NOTES
42 61D0008
Page 43
ATTENTION
APPLIANCE
INSTALLER
PLEASE RETURN THESE
OPERATING AND
INSTALLATION
INSTRUCTIONS
TO THE CONSUMER!
61D0008 43
Page 44
LIMITED WARRANTY
FACTORY-BUILT FIREPLACE AND COMPONENTS
(EXCEPT BLOWERS)
WHAT IS COVERED AND FOR HOW LONG
• Five-Year Coverage: For five years from the date this fireplace and components are first purchased for use, Martin Hearth and
Heating will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed
the factory retail price in effect at the time of purchase.
• Ten-Year Coverage: From the sixth through the tenth year following the date this fireplace or accessory is first purchased for use,
Martin Hearth and Heating will make available to you, at our factory, a free replacement for any defective part in this fireplace or
accessory.
• Twenty-Five-Year Availability of Replacement Parts: From the eleventh through the twenty-fifty year following the date this
fireplace or accessory is first purchased for use, Martin Hearth and Heating will make available at our factory replacement parts for
this fireplace or accessory, which you may purchase for the list price current at the time your purchase order is received.
WHAT IS NOT COVERED
This limited warranty does not cover:
• Transportation or shipping cost.
• The cost of a service call to diagnose trouble.
• Painted surfaces.
• Damage or defect caused by improper installation, accident, misuse, abuse or alteration.
• Poor ventilation of smoke or gases caused by air-conditioning and heating systems, exhaust fans, or pressure differentials produced
by wind.
• Broken glass components
• Cracks in ceramic and castable parts that do not affect safe operation.
• We do not warrant this fireplace to be in compliance with your local building code. Building codes vary greatly throughout the country, and you should determine whether your local building code contains restrictions on the use of this fireplace before you purchase
it.
• Blowers or fans, which are warranted separately.
• Heat loss due to the passage of heat or air through or around the fireplace.
Also, under our five year coverage, we do not pay the cost of removal and replacement of any portion of the structure in which the fire
place is situated, made necessary by the repair, removal or re-installation of the fireplace.
And under our twenty-five year warranty of availability of replacement parts, we only promise to maintain a supply of replacement parts
at our factory for you to purchase.
LIMITATIONS AND EXCLUSIONS
1. No one has authority to add to or vary this limited warranty, or to create for Martin Hearth and Heating any other obligation of
liability in connection with this fireplace and accessory.
2. Martin Hearth and Heating shall not be liable for incidental, consequential, special or contingent damages you might suffer as a result
of its breach of this written warranty or any implied warranty. Some states do not allow the exclusion of limitation of incidental or
consequential damages, so the above limitations may not apply to you.
3. This warranty applies only to the original purchaser of the fireplace or to the original owner of the dwelling when the fireplace is
installed in a new dwelling and may not be transferred.
-
5. This warranty applies only to a fireplace sold and used in the United States.
For information about this warranty, contact:
Technical Services Department
2813 W. Mall Drive, Unit B
Florence, Alabama 35630
1-866-500-5671
www.martinhearthandheating.com
October 2004 P/N 61D0008 • Rev. 2
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.