Adding a calibration circuit when T/BLK-4 is not used
Note: The calibration circuit must always
be fitted, even when scaling resistors are
not fitted. This circuit is fitted as standard
on T/BLK-4.
100k
3k
1k5
R
CAL
V+
(Red/2)
Vref
COM
(Orange/3)
(Brown/1)
WIRE CONNECTIONS and SCREW TERMINAL FUNCTIONS
(EMV 1125) (T.BLK-4)
0. Black (BK) V- Negative power supply connection.
1. Brown (BR) COM The ground for the analogue section of the A/D converter,held activelyat 2.8V(nom.)belowV+.
COM must not be allowed to sink excessivecurrent (>100 A)byconnecting it directly to a higher voltage.
Positivepower supplyconnection.
3. Orange (OR) Vref Connection forcalibration circuit(seediagrambelow).
4. Yellow (YL) IN HI Positive measuring differential input. IN HI and IN LO must be no closer than 1V to either the positiveor negativesupply.
5. Green (GN) INLO Negative measuringdifferentialinput. (On T/BLK-4,INLO is connectedtoCOMvianormally-closedLinkL2.)
6. Blue (BL) DP COM Commonconnection fordecimal pointsDP1, DP2andDP3,seebelow.
µ
2. Red (RD) V+
7. Violet(VI) DP1 199.9
8. Grey (GY) DP2 19.99 Connect to DP COM to display required decimal point.
9. White (WT) DP3 1.999 (or makeappropriate solderlink onT/BLK-4)
Do notconnect more than one meter to the same powersupply if the meters cannot use the same signalground. Taking any input beyond the power supplyrails
will damage themeter. Keep leads shortto ensure noise-free operation.
Specifications liable to change without prior warning EMV 1125 Issue 3 January/2001 M.C. Applies to EMV 1125/2
Required F.S.R. Ra Rb CAL
200mV N/A N/A Adjust
2V 910k 100k
20V 1M 10k
200 A 0R 1k
2mA 0R 100R
20mA 0R 10R Ad
200mA 0R 1R
Adjust
Adjust
Adjust
Adjust
just
Adjust
µ
SCALING and CALIBRATION
A calibrationcircuit andtwo resistors (Raand Rb)may be added on the
EMV 1125 or T/BLK-4 board (cut Link La if fitting Ra) to alter the full
scale reading of the meter - see table. Note that the meter will have to
be (re-)calibrated byadjusting thepotentiometer.
APPLICATIONS
INPUT
+
-
Ra 100k
Rb
IN HI
(Yellow/4)
IN LO
(Green/5)
Adding an input filter and scaling resistors when T/BLK-4 is not used
100nF
Note: To reduce noise on the meter's input, fit the input filter components (1M
and 10nF) shownabove. Theinput filter is fitted as standardon T/BLK-4.
1
CAL
Rb
V- V +
INHI
INLO
Ra
La
L1
L2
123
DP
BK BR RD OR YL GN BL VI GY WT
Solder wires from EMV 1125
Calibration
potentiometer
Scaling resistors (values for 2V and 20V FSD Supplied with T/BLK-4)
Decimal point
links
Connecting to T/BLK-4
Measuring current.
Recalibrate the module.
The current to be measured must be
isolated from the module's power supply.
Rb =I0.2
Full Scale
+
+
-
-
Supply
Voltage
Current to be
measured
1
CAL
Rb
V- V+
INHI
INLO
Ra
La
L1
L2
123
DP
BK BR RD OR YLGN BL VI GY WT
+
-
Supply
Voltage
1
CAL
Rb
V- V+
INHI
INLO
Ra
La
L1
L2
123
DP
GN BL VI GY WT
Measuring a supply voltage.
(min. 7.5V, max. 15V)
Cut Links La and L2.
Recalibrate the module.
510k
510k
10k
Measuring a floating voltage
source of 200mV full scale.
Add Ra and Rb and cut Link La to
increase the measurement range.
+
+
-
-
Supply
Voltage
+200mV
Input Voltage
1
CAL
Rb
V- V+
INHI
INLO
Ra
La
L1
L2
123
DP
BK BR RD OR YLGN BL VI GY WT