QM 130 M 9SegmentLCDMeter
This low cost, compactindicatorisideally suited for low or highvolumeapplications. The meter features a 9segmentLCDtodisplay 1V d.c.
full scale reading. Other voltagesandcurrents can be measured viatheadditionof2scaling resistors. The meter canbeusedinapplications
where the orderofmagnitude of the reading ismoreimportant than the value ofthereading itself. It allows theoperatorto scan the display
and receive a quick visual feedback. Installation is particularly easy; the module requires only a single round hole in the panel. A rubber
seal is included, providing splashproof protection for the unit when fitted to the meter during installation.
9 Segment LCD
Colour Scale
Auto-zero
1V d.c. Full Scale Reading
Single Hole Mounting
No Calibration Required
Splashproof
Stock Number
StandardMeterQM 130M
Specification Min. Typ. Max. Unit
Accuracy (overall error) * 1 Segment ( 1)
Full scale reading 1 V d.c.
Resolution 125 mV d.c.
Sample rate samples/sec
Operating temperature range 0 50 °C
Supply voltage (V+ to V-) 5 9 12 V d.c.
Supply current (@5Vd.c.) mA
10
6
+
* At voltages above 1V d.c., the display flashes.
DIMENSIONS All dimensions in mm (inches)
Seal
Panel
QM 130 M
21.40 (0.84)
/
32
43.50 (1.71)
21.75 (0.85)
5.00
(0.20)
14.0 (0.55)
9.0
(0.35)
31.0 (1.22)
Viewing Area
Washer
(Display shown in overrange mode)
10.70
(0.42)
10.70
(0.42)
PANELFITTING
Drill a5.5mm / " holein the panel. Fit seal tothe rear ofthe module. Fit the module to the panel by passing its screw threaded studand the wiresthrough the
hole, fitting the washer and tightening the nut. Take care not to trap any of the connecting wires. Do not to overtighten the nut as this may damage the meter.
REAR VIEW
21.75 (0.85)
Module thickness: 5.5mm (0.22")
7
3 Wires - 30cm (12.0)
Nut
Martel Electronics, Corp. P.O. Box 770 Londonderry, NH 03053
Toll Free: (800) 821-0023 Phone: (603) 434-1433 Fax: (603) 434-1653
WIRE FUNCTIONS
RED V+ Positivepower supplyconnection.
BLACK 0V Negative powersupplyconnection.
WHITE Vin Positivemeasuring inputwithreference to0V.
Range from0to 1Vd.c.
SCALING
Two external resistors may be used to alter the full scale
reading of the meter - see table for sample values.
Alternatively, use the following formulae to calculate Ra
and Rb. Select the nearest available standard resistor. To
achieve optimum accuracy, use1%metalfilmresistors.
Required F.S.R. Ra Rb
10V 910k 100k
100V 1M 10k
10mA 0R 100R
100mA 0R 10R
Voltage
Ra
+
V1 V2
Rb
-
Vin
0V
Ra=1M
Rb=Ra.
V2 .
V1-V2
Current
+
-
Vin
I
FSD
Rs
0V
Rs=I1V
FSD
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. The user must
ensure that the incorporation of the unit into the user’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements
for Electrical Equipment for Measuring, Control and Laboratory Use).
VARIOUS OPERATING MODES
5...12Vd.c.
V+
0V
0V
0-1Vd.c.
5...12Vd.c.
V+
Vin
+
0V
-
0V
Power
Supply
Load
Vin
Rs
Measuring a voltage in the range
Measuring a d.c. current.
0 to 1V d.c.
Rs =I1V
5...12Vd.c.
V+
Power
Supply
I
Load
Rs
Vin
Current
V+
0V
Ra
Vin
Rb
Voltage
0V
0V
Simultaneous d.c. Voltage and Current Measurement.
Rs =I1V
SpecificationsliabletochangewithoutpriorwarningQM 130M Issue8September/2001M.C.AppliestoQM 130M