Martel Electronics QM120ET User Manual

QM 120 ET Nema 4 SingleHoleMountingElapsedHourMeter
QM 120ET isaneasytomountLCDdigitalelapsedhourmeter.Themodulefeatures9999.9and99999hourranges,resultingin1/10hourand1hourresolution respectively.Aleadingzeroblankinginputisprovided,allowingtheusertoswitchoffunwantedleadingzeros.Themoduleincorporatesanoutputwhich pulseshighaftereveryhourcounted.Thisisparticularlyusefulinapplicationswheremaintenanceorinspectionarerequiredatregulartimeintervals.The timerfeaturesTripandTotalranges.TheTriprangecanberesettozero.Tomounttheunitintoapanel,theuserneedonlydrillasingle5.5mm/hole.The moduleisfittedtothepanelbylocatingitsscrewthreadedstudthroughthehole,fittingthewasherandtighteningthenutprovided.Themodule's8 connectingwirespassthroughthehollowstudintothetargetapplication,wheretheycanbeeasilyconnectedasrequired.Arubbersealisincluded, providingsplashproofprotectionfortheunitwhenfittedtothemeterduringinstallation.
SingleHoleMounting
7
"
/
32
9999.9and99999HourRanges
TRIP
TOTAL
Hrs
9mm/0.35"LCDDigitHeight
ResetandTrip/TotalInputs
--------------------
LeadingZeroBlankingInput
PulseOutputEveryHour
ShownActualSize
Splashproof
StockNumber
EasyMountingElapsedHourMeterQM 120 ET
Seal
Elapsed
HourMeter
9.0
(0.35)
Panel
Nut
Washer
8Wires-30cm(12.0)
SpecificationMin.Typ.Max.Unit
ResolutionRange9999.90.1Hour
Accuracy*±2±6Sec./24Hrs. Operatingtemperaturerange050°C Supplyvoltage(V+)527Vd.c. Supplycurrent1.5mA InputLowVoltage(V**00.5V InputHighVoltage(V***2V+V
*Baseduponconstantrunning.Thereispotentialfor±2secondserroreachtime
themoduleispowereddownandthenupagain.Overtime,theaccumulatederror
approximatestozero. **Appliestotheinputs:Range,V-Sense,LZB,ResetandTrip/Total ***AppliestoV-Senseinputonly.
Range999991Hour
IL)
IH)
SAFETY
TocomplywiththeLowVoltageDirective(LVD93/68/EEC),inputvoltagestothemodule’swiresmustnotexceed60Vd.c.Theusermust ensurethattheincorporationofthemeterintoequipmentconformstotherelevantsectionsofBSEN61010(SafetyRequirementsfor ElectricalEquipmentforMeasuring,ControlandLaboratoryUse).
DIMENSIONSAlldimensionsinmm(inches)
LCDshowninpower-onself-testmode.
10.70 (0.42)
10.70 (0.42)
TRIP
21.40(0.84)
--------------------
REARVIEW
21.75(0.85)
Modulethickness:5.5mm(0.22")
TOTAL
43.50(1.71)
Hrs
5.00 (0.20)
21.75(0.85)
CONNECTION
0Black0V 1Brown9999.9/99999 2RedV+ 3OrangeVoltageSense 4Yellow1HrPulse 5GreenLeadingZeroBlanking 6BlueReset 7VioletTrip/Total
FITTINGTHEHourMeter
Drilla5.5mm/"holeinthepanel.Fitsealtotherearofthemodule. thepanelbypassingitsscrewthreadedstudandthewiresthroughthehole,fittingthe washerandspringwasherandtighteningthenutprovided.Takecarenottotrapanyof theconnectingwires.Do
7
/
32
notovertightenthenutasthismaydamagethemeter.
Fitthemoduleto
Martel Electronics, Corp. P.O. Box 770 Londonderry, NH 03053 Toll Free: (800) 821-0023 Phone: (603) 434-1433 Fax: (603) 434-1653
WIRE FUNCTIONS
0. Black 0V Negative power supply connection.
1. Brown RANGE Do not connect for 99999 Hour range.
2. Red V+
3. Orange V-SENSE Connect to V+to start/continue counting elapsed hours.
4. Yellow PULSE Normally at 0V,thisoutputgoesHigh(+3.3V)every100hourinterval in TRIP mode.
5. Green LZB Do not connect to display leading zeros.
6. Blue RESET Connect momentarily to 0V to reset the display to zero (internally connected to V+ via pull-up resistor).
7. Violet TRIP/TOTAL Do not connect for TOTALmode operation.InTOTAL mode, the elapsed hour meter cannot be reset to zero.
Connect to 0V for 9999.9 Hour range. Positivepower supplyconnection.
Connect to 0V or do not connect to read TRIP or TOTALvalue withoutcounting elapsedhours.
Connect to 0V to blank all leading zeros. When reading is 0000.0 or 00000, leading zeros are not blanked.
Connect to 0V for TRIP mode operation. In TRIP mode, the elapsed hour meter can be reset to zero.
Warning : Do not connect the following wires to V+: RANGE, PULSE, LZB, RESET, TRIP/TOTAL, as this may
damage the meter. The user must incorporate suitable protection circuitry in applications where the voltage to any of the meter's wires can exceed 27V d.c., including transient conditions, else damage to the meter may occur. In particular, for applications in harsh electrical environments, e.g. automotive, suitable external protection must be provided to protect against "load dump" conditions, transients, etc.
DISPLAY FUNCTIONS
8888.8 The 5 digit readout displays elapsedtime inhours.
TRIP TOTAL
----------
This symbol is displayed when trip mode is selected (see WireFunctionsabove) This symbol is displayed when total mode is selected (see WireFunctionsabove) The 10-segment incrementing bar indicates that the module is working correctly and counting hours.
APPLICATIONS
Basic 3-wire operation:
- 99999 Hour range
- Leading Zeros are displayed
- Timing in TOTAL mode Open S1 to read TOTAL value without counting hours.
TRIP TRIP
-
Orange
S1
Red Orange
TOTAL
Hrs
Black
0V
Red
Hrs
V+
V+
RedOrange
TOTAL
Hrs
-
Black
Green
S1
Leading zeros blanked. Close S1 to select TRIP mode.
Red
Orange
Hrs
V+
Violet
0V
V+
LED
R
Yellow
-
Brown
Black
9999.9 Hour range
- Leading Zeros are displayed
- Timing in TRIP mode
SpecificationsliabletochangewithoutpriorwarningQM 120 ET Issue6September/200. AppliestoQM 120 ET
Violet
0V
Using the PULSE O/P to drive an LED. The LED will illuminate once after every hour.
Black
-
Brown
Violet