Martel Electronics QM100V User Manual

QM 100V Single Hole Mounting 2-Wire Meter
QM 100V is an easy to mountLC D digitalpanel meter.
measuring. Only valid readingsare displayed; themodule indicates"LO"at voltages below4V and "HI" at voltagesabove 25V. drill a single 5.5mm / hole in the panel. The module is tted to the panel by locating its threaded stud through the hole, tting the washer and tightening the nut provided. The module's connecting wires pass through the hollow stud into the target application for connection. protection forthe unitwhen ttedto themeter duringinstallation.
7
"
/
32
The modulefeatures a4 to25V measurementrange with100mV resolutionand ispowered fromthe signalit is
To install the meter, theuser need only
A rubber seal is included, providing splashproof
Single Hole Mounting
2-Wire Operation
4to25
V d.c. Full Scale Reading
12.5mm / 0.5" LCD Digit Height
Reverse Polarity Protection
Splashproof
APPLICATION
+4 to +25V d.c.
RED
BLACK
0V
Easy Mounting V oltmeter QM 100V
Specication Min. Typ. Max. Unit
Valid displayed reading* 4.0 25.0 V d.c.
Operating temperature range 0 50 °C
* Atvoltages below4.0V d.c.,the LCDwill display and willultimately goblank.
At Voltages inexcess of25.0V d.c.,the LCD will display . Do NOTexceed 50V d.c., asthis maydamage themeter. The moduleincludes reversepolarity protectionup to30V forup to30 seconds. Operation andaccuracy atvoltages above25.0V orbelow 4.0Vare notspecied.
egatlovylppuS
LO
HI
Shown Actual Size
Stock Number
)tnuoc1±(V2.0)rorrellarevo(ycaruccA
tnuoc1±ytiraeniL
.c.dVm001noituloseR
ces/elpmas3etarelpmaS
.c.dV053
Am3tnerrucylppuS
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s wires must not exceed 60Vd.c. The user must ensure that the incorporation of the meter into the user ’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and Laboratory Use).
DIMENSIONS All dimensions in mm (inches)
21.40 (0.84)
43.50 (1.71)
REAR VIEW
10.70 (0.42)
10.70 (0.42)
FITTING THE EMV 1200-40
FITTING THE QM100V
Drill a 5.5mm / " hole in the panel. the panel by passing its screw threaded stud and the wires through the hole, tting the washer and tightening the nut provided. Take care not to trap either of the connecting wires. Do
not to overtighten the nut as this may damage the meter.
CAL
21.75 (0.85)
Module thickness: 5.5mm (0.22")
7
/
32
21.75 (0.85)
Fit seal to the rear of the module. Fit the module to
5.00 (0.20)
Reading when Vin < 4V,
before display switches o.
Reading when Vin > 25V.
WARNING! In automotive applications or where an alternator is present and there is the possibility of a transient voltage spike it is recommended to use some type of transient voltage suppressor (TVS) to protect the meter.
METER
TVS DIODE
+–
Seal
EMV 1200-40
QM100V
TVS ZENER DIODE Martel Part Number: 80311
Digikey (www.digikey.com) Part Number: 1N6287AGOS-ND
9.0
(0.35)
Panel
2 wires - 30cm (12.0)
Nut
Washer
PO Box 770, Londonderry, NH 03053 1-800-821-0023 www.martelcorp.com
Loading...