High Accuracy Pressure Calibrator with
Simultaneous mA or Voltage Measurement
Features
0.05% full scale accuracy
Microprocessor-based design
Compatible with wide range of pressure
media
Simultaneous display of pressure versus
mA or voltage signals
Pressure switch test
Built-in 24 V loop power supply
Built-in RS-232 interface
PPC-9001
Optional hand pump attaches as pressure
source
Rugged manifold with three connection
ports
Easy user access to pressure calibration
adjustment
The Martel Electronics PPC-9001 Precision Pressure
Calibrator is designed to meet the needs of the most
demanding field calibration applications. Its micropro-
cessor design yields many useful features including a
built-in RS-232 port for data transfer to a PC. The
PPC-9001 offers a wide range of pressure media
compatibility and a pressure connection manifold
that allows secure mounting of the optional hand
pump. The built-in loop power supply, combined
with milliAmp or voltage read capability, make the
PPC-9001 ideal for calibrating pressure and flow
transmitters.
Tel: 800-821-0023; E-mail: sales@martelcorp.com; Web: www.martelcorp.com
Martel Electronics, P.O. Box 770, Londonderry, NH 03053
Specifications
Pressure
Ranges 0 to 5.000 PSI
0 to 30.000 PSI
0 to 100.00 PSI
Accuracy 0.05% F.S. ±1 LSD; 18° to 28°C
Engineering Units PSI, Bar, mBar, kg/cm2, mm Hg, in Hg, kPa, in H
cm H
0 @ 4 °C, cm H20 @ 20 °C, mm H20 @ 4 °C
2
Electrical
Ranges 0 to 24.000 mA
0 to 20.000 VDC
Accuracy 0.05% F.S. ±1 LSD; 18° to 28°C
Current Overload Protection 1/8 A fuse
Temperature Stability 0.01%/°C for both pressure and electrical for temperatures outside of 23°C ±5°C
Loop Power 24 VDC ±10%; supply built-in
Environmental
Operating temperature 32 to 122°F / 0 to 50°C
Storage temperature -20 to 60°C
Media Compatibility
All pressure ranges non-corrosive gasses and liquids
Connections
Pressure 1/8" FNPT
Current banana jacks on 3/4" centers
Pressure Switch Test dry, (unpowered) contacts only, nominal 24 mA @ 24 VDC excitation current supplied
to contacts
Display LCD
dual pressure and mA or V readout
Power Requirements 4-AA alkaline cells or 4 AA Ni-Cd cells
Optional AC adapter, Ni-Cd charger available
Dimensions 7" x 3.8" x 1.6" (177.8 x 96.5 x 40.6 mm) HWD
Accessories Included Tools, carrying case, test leads, 4 AA alkaline batteries, instruction manual, and NIST
Certificate
0 @ 4 °C, in H20 @ 20 °C, in H20 @ 60 °F,
2
Ordering Information
Description Model
High Accuracy Pressure Calibrator PPC-9001
High Accuracy Pressure Calibrator Kit PPC-9001K**
AA Ni-Cd Batteries (requires 4) 10077
Optional A/C Adapter/Charger 1001-9V
**PPC-9001K Pressure Kit
Kit includes:
PPC-9001, MECP100 Hand Pump, carrying case, test leads, AC adapter, fittings, tools, 4-AA alkaline batteries,
instruction manual, and NIST Certificate
©2002 Martel Electronics All trademarks are the property of their respective owners. 021127R0/OEMM