Martel Electronics DPM750S-BL User Manual

Page 2 of 4
DPM 750S-BL
3½ Digit Backlit LCD Voltmeter Module
The DPM 750S-BL features a 200mV d.c. measurement range with auto-zero and auto-polarity. Decimal points are user selectable.
The meter features a negative rail generator which enables the meter to measure a signal referenced to its own power supply GND. A low drift bandgap reference circuit ensures accurate readings over a wide temperature range. low cost means it will
LED backlighting ensures excellent readability under low light conditions. The module's suit high and low volume applications. This module is supplied with a plastic mounting bezel. A waterproof seal to IP67 / NEMA 4X is achievable, using the optional BEZ 700-IP bezel.
FEATURES
• 12.7
mm (0.5") Digit Height
• 200mV d.c. Full Scale Reading
• 3.0 to 7.5V or 6.0 to 15V d.c. Operation
Auto-zero and Auto-polarity
Programmable Decimal Points
• Low Battery Warning
• Bandgap Reference
°°
CF
µA
mV
k
MH
z
TYPICAL APPLICATIONS
• Precision Instrumentation Systems
• Power Supply Monitoring
• Test Boxes
ORDERING INFORMATION
Stock Number Standard Meter DPM 750S-BL IP67 / NEMA 4X Bezel BEZ 700-IP
• Panel-Mount Indication
• Low Power Voltage Measurement
ELECTRICAL SPECIFICATIONS
Specification Min. Typ. Max. Unit
Accuracy (overall error) * 0.1 % (±1 count) Linearity ±1 count Sample rate 2.5 samples/sec Operating temperature range 0 50 °C Temperature stability 50 ppm/°C Supply voltage V+ to GND configuration 3 5 7.5 V d.c.
Supply current V+ to GND configuration 500 A
Backlight supply voltage 4.75 5.0 ** V d.c. Backlight supply current @ 5V d.c. 30 mA Input leakage current (Vin = 0V) 1 10 pA
* To ensure maximum accuracy, re-calibrate periodically.
** An external series resistor is required above 5V, see Applications.
*** This specification linearly derates to 30mA @ 50°C.
V+ to V- configuration 6 9 15 V d.c.
µ
V+ to V- configuration
350 A
50 ***
µ
SAFETY
To comply with the Low Voltage Directive (LVD93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. The user must ensure that the incorporation of the panel meter into the user’sequipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and Laboratory Use).
LASCAR ELECTRONICS LTD. MODULE HOUSE WHITEPARISH WILTSHIRE SP5 2SJ UK TEL: +44 (1794) 884567 FAX: +44 (1794) 884616 E-mail: sales@lascar.co.uk
LASCAR ELECTRONICS INC. 3750 West 26th Street Erie PA 16506 USA TEL: +1 (814) 835 0621 FAX: +1 (814) 838 8141 E-mail: us-sales@lascarelectronics.com
PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.lascarelectronics.com
www.martelcorp.com
LASCAR ELECTRONICS (HK) LIMITED FLAT C, 5/FL., LUCKY FTY. BLDG. 63-65 HUNG TO ROAD KWUN TONG KOWLOON HONG KONG TEL: +852 2797 3219 FAX: +852 2343 6187 E-mail: b4lascar@samsongroup.com.hk
Page2of4
Page1of4
page 1 of 4
Page 2 of 4
DPM 750S-BL
DIMENSIONS
All dimensions in mm (inches)
3½ Digit Backlit LCD Voltmeter Module
34.5 (1.36)
64.5 (2.54)
Panel cut-out: 62.0 - 32.0
(2.44 - 1.26)
PANEL FITTING
Panel thickness: 1.0 - 3.0
(0.04 - 0.12)
25.0 (0.98)
53.0 (2.17)
46.7 (1.84)
60 (2.36)
2.8 (0.11) dia
6.1 (0.24)
30 (1.18)
17.7 (0.7)
6.1
(0.24)
1.6 (0.06)
(0.26)
1.6
(0.06)
6.5
9.5
(0.37)
Insulating Washer
FUNCTIONAL BLOCK DIAGRAM
V+
Vref
COM
INHI
INLO
CAL
BL-
+
_
A/D
8
1
Shake-proof Washer
21
3
PIN CONFIGURATION (rear view)
Vm°CA°FµMkOhmHz:
CAL
V+
GND
(0.1)
LCOM
BL-
INHI
INLO
DP1
Rb Ra
DP2
DP3V-COM
~
La
101
18.6 (0.73)2.54
6.3
(0.25)
V-
DP321GND
Page2of4
PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.lascarelectronics.com
www.martelcorp.com
Page2of4
page 2 of 4
DPM 750S-BL
CIRCUIT DIAGRAM
1
4
5
10
LCOM
3½ Digit Backlit LCD Voltmeter Module
XDP
2
BC847
BC847
V+
33
3
9
6
7
8
PIN FUNCTIONS
1. V+ Positivepower supply to the meter andLEDbacklighting.
2. GND 0V powersupplyto the meter.
3. BL- Negativepowersupplyconnectionto the LED backlighting.
4. INHI Positivemeasuring input.
5. INLO Negative measuring input.
6. DP1 Connect toV+todisplayDP1 (199.9).
7. DP2 Connect toV+todisplayDP2 (19.99).
8. DP3 Connect toV+todisplayDP3 (1.999).
9. V- Negative power supplytothe meter.
10. COM Ground foranaloguesection of A/D converter. It isactivelyheldat3.05V (nom.) below V+ and mustnotbeallowed to sink excessive current (>100 A) by,for instance, connecting to a highervoltage.
µ
LCD 600
XDP
BC847
Note: A negative supply is generated internally and mirrors the positive supply. For example: if V+ is +5V, then the
internally generated V- is -5V. When measuring with the input referenced to the same supply rail as that of the panel meter,thenthelimitationson the input range are (V- + 1.5V) to (V+ - 1.5V).
SOLDER LINKS
LCOM Normally Open. When soldered,connectsCOMtoINLO. La Normally Closed. Short circuitsthescalingresistorRa.
PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.lascarelectronics.com
Page3of4
www.martelcorp.com
page 3 of 4
Page 4 of 4
DPM 750S-BL
3½ Digit Backlit LCD Voltmeter Module
SCALING
Two resistors Ra and Rb may be used to alter the full scale reading (FSR) of the meter - see table. The meter will have to be re­calibrated by adjusting the calibration potentiometer on the rear of the module.
Voltage
Vin 200V 1M 1k
Current
I
in 20mA 0R 10R
*Ensure that Ra is rated for high voltage use.
FSR Ra Rb
2V 910k 100k
20V 1M 10k
2000V* 1M 100R
200 A 0R 1k
µ
2mA 0R 100R
200mA 0R 1R
+
Vin or inI
-
Ra
Rb
4
INHI
5
INLO
APPLICATIONS
Do not connect more than one meter to the same power supply if the meters cannot use the same signal ground. Taking any input beyond the power supply rails will damage the meter.
3.0 to 7.5V Meter Power Supply
+3.0 to +7.5V
+
4
11 1
V+
INHI
BL-
3
±200mV
-
Measuring a single ended input voltage referenced to supply, i.e. the input voltage and the meter's power supply share the same 0V rail. Ensure solder link LCOM is open.
5
INLO
GND
22 2
6.0 to 15.0V Meter Power
+3.0 to +7.5V
+
±200mV
-
-3.0 to -7.5V
4
5
INHI
INLO
V+
V-
1
3
BL-
9
+3.0 to +7.5V
V+
44
+
INHI
±200mV
S
BL
R=
BL
V+-5V
30mA
-
5
INLO
GND
0V
Measuring an input voltage referenced to a floating supply, i.e. the input voltage and the meter's power supply are isolated from each other. Ensure solder link LCOM is closed.
+6.0 to +15.0V
1
V+
4
+
INHI
±200mV
S
BL
R=
BL
V+-V--5V
30mA
-
5
INLO
V-
9
+3.0 to +7.5V
V+
5
INHI
INLO
GND
S
BL
V+-5V
BL
30mA
33
I+
BL- BL-
S
BL
R=
V+-5V R=
BL
30mA
Rb
I-
0V 0V
Measuring a current from a circuit which is floating with respect to the DPM's supply, i.e. the current and the meter's power supply are isolated from each other. Ensure solder link LCOM is closed.
BL-
+6.0 to +15.0V
3
S
BL
R=
V+-5V
BL
30mA
Rb
I-
I+
4
5
0V
INHI
INLO
V+
V-
1
R=
V+-5V
BL
30mA
3
BL-
S
BL
R
BL
9
0V
Measuring a single ended input voltage referenced to a split supply, i.e. the input voltage and the meter's power supply share the same 0V rail. Ensure solder link LCOM is open.
Specifications liable to change without prior warning DPM 750S-BL Issue 1 August/2002 M.C. Applies to DPM 750S-BL/2
Measuring an input voltage referenced to a floating supply, i.e. the input voltage and the meter's power supply are isolated from each other. Ensure solder link LCOM is closed.
PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.lascarelectronics.com
www.martelcorp.com
Measuring a current from a circuit which is floating with respect to the DPM's supply, i.e. the current and the meter's power supply are isolated from each other. Ensure solder link LCOM is closed.
Page4of4
Page4of4
page 4 of 4
Loading...