Martel Electronics DPM2000 User Manual

DPM 2000 3½ Digit LCD Module
The DPM 2000 uses advanced components and construction techniques to provide an unrivalled combination of high performance, elegant appearance and low cost. The module uses a bandgap reference for extra temperature stability. For single rail operation, the DPM 2000S features abuilt-innegativerailgenerator,enablingthemeter to measurea signalreferenced to itsown powersupply 0V.
15mm (0.6“) Digit Height
Programmable Decimal Points
Auto-zero
Auto-polarity
200mV d.c. Full Scale Reading (F.S.R.)
Single Rail Version
SCALING
Two resistors Ra and Rb may be fitted in order to alter the full scale reading (F.S.R) of the meter - see table. The meter will need re-calibration.
Required F.S.R. Ra Rb
2V Note 910k 100k 20V Note 1M 10k 200V Note 1M 1k 2kV Note 1M 100R 200 A link 1k
µ
2mA link 100R 20mA link 10R 200mA link 1R
NOTE
Ensure that link 10 is open if fitting Ra.
Standard Meter DPM 2000 Single Rail Version DPM 2000S
Specification Min. Typ. Max. Unit
Accuracy (overall error) * 0.05 0.1 % (±1 count) Linearity ±1 count Sample rate 3 samples/sec Operating temperature range 0 50 °C Temperature s 30 ppm/°C Supply DPM 2000 7.5 9 14 (V+ to V-) DPM 2000S 3.5 5 6.5 Supply current DPM 2000 150
Input leakage current (Vin = 0V) 1 10 pA
* To ensure maximum accuracy, re-calibrate periodically.
tability
voltage
DPM 2000S 500
Stock Number
V
A
µ
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the measuring inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure that the incorporation of the DPM into the user’s equipment conforms tothe relevantsections of BS EN61010 (SafetyRequirements forElectrical Equipmentfor Measuring, Control andLaboratory Use).
DIMENSIONS All dimensions in mm (inches)
32.5 (1.28)
36.0 (1.42)
27.5 (1.08)
72.0 (2.83)
Display in TEST mode
67.5 (2.66)
60.0 (2.36)
53.0 (2.09)
62.5 (2.46)
Ø2.50
(0.10)
19.0 (0.75)
29.5 (1.16)
ab
cd e
29.5 (1.16)
8
+
LMP
TEST
9
H5
12
13
fg
­pH
XB3
XDP
6
11 4 2 7
14
Rb Ra
g
µ
V
%
°F
°C
-5V
CLK
XG3V+RBG
REF-
A
m
M
REF+E3BPABPOL
K
DP1
REF HI
3
1
5
10
:
-
~
DP2
DP3
L
H
REF LO
COM
V-II
ON BOARD SOLDER LINKS
SCALING RESISTORS
a. 1.00 (0.04) b. 9.00 (0.35) c. 1.25 (0.05) d. 5.50 (0.22) e. 4.00 (0.16)
f. 0.50 (0.02)
g. 2.54 (0.10)
Martel Electronics, Corp. P.O. Box 770 Londonderry, NH 03053 Toll Free: (800) 821-0023 Phone: (603) 434-1433 Fax: (603) 434-1653
PIN FUNCTIONS
1. V- Negative power supply connection.
2. IH Positivemeasuring input. Analogue inputs mustbe nocloser than1V to either thepositive or negative supply. The negative
3. IL Negativemeasuring input. supply of anS-type meteris generatedinternally and mirrorsthe positive supply voltage.
4. COM The ground forthe analoguesection ofthe A/D converter,held actively at2.8V (nom.)below V+. COM mustnot beallowed to sink excessivecurrent (>100 A) byconnecting it directlyto ahigher voltage.
µ
5. REF LO Negative inputfor referencevoltage.
6. REF HI Positiveinput forreference voltage(connected via Link1 toREF+).
7. POL Drivefor negative(-) annunciator. Internally connectedvia Link 11to theannunciator.
8, 10, 15,19 Outputs for autorangingapplications.
9. BP LCD backplane drive waveform.
11. REF+ Positiveoutput frominternal reference (connectedvia Link1 toREF HI).
12. REF- Negative output frominternal reference. MUST betied to asuitable groundreturn to bias bandgap(normally COM).
13. R BG Ouput of bandgapreference (1.22V nom).
14. V+ Positive power supplyconnection.
16. CLOCK Clock output. Maybe usedfor systemstiming or as aninput to overridethe internaloscillator and control the samplerate.
17. -5V Outputfrom negativerail generatorcircuit (DPM 2000Sonly). This isan inversion ofV+.
18. XDP Connectto requiredannunciators/DPs(see Special Note- Annunciators).
20. TEST Connect to V+to momentarilyturn on segmentsas illustrated. It shouldnot beoperated formore than afew secondsas theD.C. voltage applied tothe LCDmay 'burn'the display. This pinis 5V (nom)below V+and isthe ground for thedigital section ofthe meter. It can beused topower externallogic up to amaximum of 1mA.
SPECIAL NOTE - ANNUNCIATORS.
The DPM annunciators (DPs, °C, etc.) can be displayed either by connecting to XDP or by applying a solder blob link to the XDP pads located under the annunciator input
pads. However, as these annunciators are normally 'floating', under certain conditions
they may appear when not wanted. To suppress unwanted annunciators, apply a
solder blob to the backplane pads located in-between the annunciator input pads. If the annunciators are being switched, connect them via M resistor to the BP
(Pin 9), the annunciators will then operate normally when connected to XDP. Ensure
that an annunciator is not connected directly to the XDP and BP at the same time. Note - if suppressing POL (-) annunciator by direct connection to BP then Link 11 MUST be cut first.
RIGHT
ANNUNCIATOR
XDP
Link either BP or XDP
to annunciator.
ANNUNCIATOR
BP
XDP
WRONG
ANNUNCIATOR
XDP
Do not link BP & XDP
to the annunciator
at the same time
ANNUNCIATOR
BP
XDP
VARIOUS OPERATING MODES
ON-BOARD LINKS: In order to quickly and easily change operating modes for different applications, the meter has several on-board links. They are designed to be easily opened (cut) or shorted (soldered). Do not connect more than one meter to the same power supply if the meters cannot use the same signal ground. Taking any input beyond the power supply rails will damage the meter.
2
±200mV
Check Links 2, 3 & 4 are SHORTED.
+
3
-
Measuring a floating voltage source of 200mV full scale.
2
R
3
0.2
R=
I
FSR
Check Links 2, 3 & 4 are SHORTED.
Measuring current (supply MUST be isolated).
IN HI
IN LO
IN HI
IN LO
V+
14
V+
V-
1
V-
+
±200mV
Check Links 3 & 4 are SHORTED. Check Links 3 & 4 are SHORTED.
-
0V
1vmin.
3
2
V+
IN HI
IN LO
V-
Split supply operation (DPM 2000).
V+
14
V+
1
V
2
V
V-
1
V-
Check Link 1 is OPEN.
V+
2
+
IN HI
3
-
IN LO
6
+
REF HI
5
REF LO
-
V-
Measuring the ratio of two voltages. Reading = 1000 V /V
50mV < <200mV V<2V
V
12.
12
2
V+
Normally OPEN Solder to SHORT
V+
14
V-
1
V-
Normally SHORTED Cut to OPEN
V+
14
2
14V max. 7V min.
1
V-
±200mV
+
-
3
IN HI
IN LO
Measuring a single ended input referenced to supply (DPM 2000S).
2
3
4
IN HI
REF BG
IN LO
COM
V+
14
V+
V-
1
V-
V+
14
1
V-
IIN
13
100K
6R2
SET
5K
ZERO
IOUT
Check Links 3 & 4 are SHORTED.
Measuring 4-20mA to read 0-999 (supply MUST be isolated).
Specifications liable to change without prior warning DPM 2000 Issue 3 August/1997 M.C. Applies to DPM 2000/5
Loading...