The Martel Electronics 307 and 308 Temperature
307 and 308
Temperature Meters
Meters
ment of temperature. Both instruments provide ±0.3% of
reading or better accuracy and 0.1°C/°F resolution over their
measurement ranges. Both instruments feature input protection
to 60 VDC or 24 Vrms. REL, HOLD, MIN/MAX, and °C/°F
selection functions simplify use. Both automatic power off to
preserve and extend battery life.
provide a variety of options for the accurate measure-
Features:
Single (307) or dual (308) inputs
-200 to +1370 °C /-328 °F to +2,498 °F
measurement range
Dual display (308)
°C/°F function select button
Model 307
The 307 is a single-input, auto-ranging temperature
meter with a measurement range of -200 to +1370
°C/-328 °F to +2,498 °F. REL, HOLD, MAX/MIN,
and °C/°F selection functions, and temperature unit
selection are available at the push of a button.
Model 308
The 308 is a dual-input, dual display, auto-ranging
temperature meter with a measurement range of
-200 to +1370 °C/-328 °F to +2,498 °F. REL, HOLD,
MAX/MIN, and °C/°F selection functions, and
temperature unit selection are available at the push
of a button.
Specifications (25°C unless otherwise noted)
Inputs
307 1
308 2
Measurement Range
Celsius -200 °C to +1,370 °C
Fahrenheit -328 °F to +2,498 °F
Input Protection 60 VDC or 24 Vrms AC max.
Accuracy
Celsius ±0.3 % of reading +1.0 °C
Fahrenheit ±0.3 % of reading +2.0 °F
Resolution
Celsius 0.1 °C
Fahrenheit 0.1 °F
Display
307 Single
308 Dual
Special Features
Auto power off, REL function, HOLD function,
MAX/MIN function
Autoranging
Temperature Range
Operating 0 °C to +40 °C; <80% RH
Storage -10 °C to +60 °C
Power Requirements
Battery Type 9 V; NEDA 1604, IEC 6F22, JIS 006P
Mechanical
Dimensions 7.2" L x 2.5" W x 1.1" H
(18.4 cm x 6.4 cm x 3.0 cm)
Weight 7.0 ounces (200 gms)
Accessories (included)
Battery, instruction manual, Type-K bead sensor (1- w/307; 2- w/308)
Temperature Probe Kits
A variety of temperature probe configurations are available for use with the 307 and 308
temperature meters. All are Type-K, and feature ±2.2°C/±0.75% or ±3.9°F/±0.75% accuracy.
TP-K01 — Bead Probe
-50°C to 200°C/-58°F to +392°F
TP-K02 — Immersion Probe
-50°C to 700°C/-58°F to +1,292°F
TP-K03 — Surface Probe
-50°C to 400°C/-58°F to +752°F
TP-K04 — Piercing Probe
-50°C to 600°C/-58°F to +1,122°F
TP-K05 — Surface Probe
-50°C to 400°C/-58°F to +752°F
TP-K06 — Air & Gas Probe
-50°C to 800°C/-58°F to +1,504°F
©2001 Martel Electronics All trademarks are the property of their respective owners. 010829R0/OEMM/5M