Marson MT6222 Quick Manual

Page 1
2D Fixed Barcode Scanner
2D Fixed Barcode Scanner Quick Guide (Rev2) P/N: 8013-0055001
SPECIFICATIONS
STEP1 - CONNECT TO HOST STEP2 - CONFIGURE INTERFACE STEP3 - POSITION SCANNER STEP4 - INSTALL SOFTWARE UTILITY
DIMENSION SCANNING RANGE
Light source 625nm visible red LED Aimer 650nm visible red Laser Scan rate 60 frames/sec Resolution 5mil/ 0.127mm PCS 30% Width of Field 131mm (13Mil Code39) Depth of Field 5 Mil Code39: 55 - 160mm 10 Mil Code39: 65 - 270mm 13 Mil UPC/EAN: 65 - 285mm 10 Mil DataMatrix: 50 - 125mm 10 Mil QR Code: 65 - 130mm Dimension W56 x L41 x H20 mm Housing ABS (Housing), PC (Back Cover) Weight 120g ± 10g Cable Length 90cm/35.4in (Fixed Cable) Interface RS232, USB HID, USB VCP Voltage 5VDC±5%
Working Current < 320mA Standby Current < 100mA Operating Temp. -10 to 55˚C (14˚F to 131˚F)
Storage Temp. -20 to 65˚C (-4˚F to 149˚F)
Ambient Light 30,000 lux
Drop Durability 1.5M
Sealing IP55 Symbologies QR Code, DataMatrix, PDF417 and all major 1D barcodes
Top View
Front View
RS232 (D-Sub 9 Female):
Pin
Signal 2 3 5 7 8
TXD(Out)
RXD(In)
GND
CTS(In)
RTS(Out)
USB Connection USB Connection
RS232 Connection
RS232 Connection
1. Connect the scanner to the host.
2. The scanner will be powered by the USB connection.
1. By default, barcode data will be sent as HID keyboard input (USB HID).
2. Below configuration barcodes allow you to switch between two USB modes (USB HID & USB VCP)
3. For USB VCP driver, please download it from our web­ site or contact your local distributor.
4. Only USB VCP interface allows you to enable software trigger (see back page for details)
2. Pitch the scanner at a minimum of ±5˚ to avoid specular reflection.
1. Maximum Scan Angle: Skew ±55˚, Pitch ±55˚, Tilt ±360˚
Skew ±55˚
Pitch ±55˚
Tilt ±360˚
Based on different hardware & configuration method, there are 2 types of software utility:
1.
EZU Software - works with USB HID interface
2. BEO Software - works with RS232 & USB VCP and supports command operation
Both are available for download from below link:
Please visit www.marson.com.tw and enter MT6222 > Downloads
Or simply scan below barcode by smartphone
1. Connect the scanner to the host.
2. Supply power directly to Pin 9 or plug power adapter to the DC Jack. The scanner will be powered up.
1. By default, barcode data will be transmitted by the communication protocols of 9600-8-N-1
2. RS232 interface allows you to enable software trigger (see back page for details)
Quick Guide
56mm
41mm
20mm
Side View
Scanner (Side View)
Barcode
+5VCC
9
Pin
Signal 1 2 3
+5VCC
Data ­Data +
4 GND
USB (Type A Male):
. C006$
USB VCP
. C008$
USB HID
(Top View)
5 Mil Code39: 55 - 160mm
10 Mil Code39: 65 - 270mm
13 Mil EAN/UPC: 65 - 285mm
6.67Mil PDF417: 60 - 130mm
20Mil PDF417: 55 - 185mm
10Mil DataMatrix: 50 - 125mm
20Mil DataMatrix: 65 - 230mm
10Mil QR Code: 65 - 130mm
15Mil QR Code: 45 - 170mm
36˚
Unit: MM
Auto-sensing Area
Barcode Scanning Area
Page 2
STEP5 - CONNECT
STEP5 - CONNECT
STEP6 - CONFIGURE THE SCANNER
STEP6 - CONFIGURE THE SCANNER
ADVANCED - READING MODE
ADVANCED - READING MODE & COMMAND
EZU SOFTWARE CONFIGURATION (USB HID)
BEO SOFTWARE CONFIGURATION (RS232 & USB VCP)
1. Right-click on the icon on the desktop and tick “Run this program as an administrator” in the pop-up menu.
2. Double-click icon on the desktop to launch the program.
3. In Communication Setting window, select “2D-Fixed” as genre and “USB” as interface. Click [Save Home(H)] to continue.
1. Click on icon on the toolbar to retrieve scanner’s parameters.
2. Double-click on the items you want to edit and then press [Enter] to save changes.
1. By default, the scanner is in Infrared Auto-Sensing Mode, which enables it to start scanning when an object comes within Auto-Sensing Range. The scanner will scan again only after the object/barcode that has been successfully scanned previously is removed from Auto-Sensing Range. This mode is best suited for access control, kiosk, parking , e-locker and so on.
2. Auto-Sensing Range is configurable. To configure Auto­ Sensing Range, go to Ez Utility > General Settings > Reading Operation > Auto-Sensing Range; there are three options avaliable: (1) Near - Max. 13cm Auto-sensing Range (2) Middle (Default) - Max. 20cm Auto-sensing Range (3) Far - Max. 27cm Auto-sensing Range
1. Continuous Mode enables the scanner to scan continuously To configure Continuous Mode, please go to Ez Utility > General Settings > Reading Operation > Reading Mode
2. Continuous Mode can deal with more scan-intensive applications, such as factory automation (production line).
3. Click on icon on the toolbar to update scanner’s parameters.
4. Click on icon on the toolbar if you want to save current configurations for later use.
Ez Utility
Ez Utility
1. Right-click on the icon on the desktop and tick “Run this program as an administrator” in the pop-up menu.
2. Double-click icon on the desktop to launch the program.
3. Click on icon on the toolbar, set 9600-8-N-1 and set COM# as appropriate. Click [Save Home(H)] to continue.
BEO
BEO
1. Click on icon on the toolbar to retrieve scanner’s parameters.
2. Double-click on the items you want to edit and then press [Enter] to save changes.
1. The scanner with RS232 or USB VCP interface supports Serial Trigger Mode which allows user to start scanning by software trigger sent from the host.
2. To configure Serial Trigger Mode, please go to BEO > Setting Window > Scan Application > Reading Mode
3. In Serial Trigger Mode, the scanner will start scanning after receiving below command:
{ G }
The scanner stops scanning after a successful barcode scan or receiving below command:
{ S }
*Note: Full functions of the scanner can be controlled by the host through software command via RS232 or USB VCP interface. For full list of commands, please refer to Serial Command Manual which is available from our website or your local distributor.
3. Click on icon on the toolbar to update scanner’s parameters.
4. Click on icon on the toolbar if you want to save current configurations for later use.
Infrared Auto-Sensing Mode
Continuous Mode
Serial Trigger Mode
Loading...