ACCESSORY INSTALLATION SUPPLEMENT
Door Limit and Magnetic Reed Switches
1. Mars door limit and magnetic reed switches are
available with NEM A 1, 4X and 7 rat ings. Contac t the
factory for additional ratin gs and details. (See FIG. 1
for typical single swing, hinged door type, door limit
switch installation)
FIG. 1
2. Use light gauge materials when field fabricating
brackets to activate and deactivate the door limit
switch(s). (FIG. 2) Figure 2 also shows the typical
installation of the combination plunger/roller type
NEMA 1 door limit switch, for all non-hinged style
doors.
Document No: ACC-IOM
Date: 0810
3. All wiring must be per local and NEC (National
Electric Code) codes.
4. Panels or controllers m ay be required. Ref er to wiring
diagram inside the control panel box.
FIG. 3
FIG. 4
14716 S. Broadway St. , Garde na, CA 90248
Bracket Installation
1. Side Extension Plates: For doorways wider than
the air curtain, use combination of Side Extension
Plates and Adjustable Mounting Brackets. (FIG. 5)
FIG. 5 (LPV Sho wn)
2. Adjustable Mounting Brackets: For installation of
air curtain over drum-style roll-up door, use
Extended Wall Mounting Brackets. (FIG. 6)
FIG. 6 (STD Shown)
3. Extended Wall Mounting: For Tandem Mounting of
air curtain over sectional style door, use either wall
mounting angle brackets or t hr eaded r ods.
4. Top Mounting Brackets: For overhead installation
of units, use in conjunction with the threaded holes
provided on top of unit.
Note: Angle brackets, threaded rods and I Beams
are provided by others. (FIGS. 7 & 8) All optional
brackets are not available for WMI/WMH and BD
Series.
(310) 532–1555 ● (800) 421-1266
Fax: (310) 324-3030