Disconnects & Safety Switches
MARS SERIES 833 & 803
Midwest A/C Disconnects - NEMA 3R
MARS
NO.
DESCRIPTION
83385 60 amp non-fused, single phase 6
83386 30 amp fused, single phase 6
3387 60 amp fused, single phase 6
8
CASE
QTY.
Pullouts For MARS Disconnect Boxes
MARS offers both fusible and non-fusible single phase non-metallic air conditioner
disconnects. These horse power rated units are constructed of Noryl
xtended and rugged durability. Units are corrosion resistant, weatherproof, and
e
maintenance free. UL listed and CSA certified.
MARS
NO.
DESCRIPTION
83313 60 amp non-fused pullout for 83315 1
83314 30 amp fused pullout for 83316 1
83318 60 amp fused pullout for 83317 1
83319 30 amp fused pullout for 83396 1
80312 60 amp non-fused pullout for 80315 & 80308 1
80313 30 amp fused pullout for 80316 1
80314 60 amp fused pullout for 80317 1
®
thermoplastic for
CASE
QTY
MARS A/C Disconnect/GFCI Receptacle Combination
MARS A/C Disconnect/ GFCI Receptacle Combination disconnects provide a convenient
low cost means to satisfy NEC Article 210.63 requirements for HVAC/R Equipment Outlets
and Article 406.8(B)(1) for Receptacle – Wet Locations. The NEMA 3R design insures a safe,
weather tight installation for residential, light commercial and even some industrial applications.
Features & Benefits:
• 60 amp, non-fused, pullout type
• 240 volt A/C, single phase
• UL & CUL listed
• Meets NEC #210.63 & #406.8(B) (1)
• Compact size – 5"x7"x4"
MARS
NO.
83308 60 Amp, Non-Fused, 15 Amp, 125V GFCI Duplex Receptacle 6
83309 60 Amp, Non-Fused, 20 Amp, 125V GFCI Duplex Receptacle 6
• Removable cover
• Heavy galvanized ‘G90’ steel with
highest quality electro-deposition
finish resists corrosion and fading
• NEMA 3R rated
DESCRIPTION
MARS
PACK
83313
83385
83308
Unique side opening door
permits greater visibility
and access to work area
83314
83318
Pre-wired GFCI
receptacle
SERVICE & INSTALLATION
MARS Side Open Pullout Disconnect w/GFCI Receptacle
The MARS Side Open Disconnect w/GFCI Receptacle provides a convenient low
cost means to satisfy NEC 2003 code changes requiring that a GFCI receptacle with
a "while in use" cover be within a 25ft line of sight of the condenser unit. The pre-wired
receptacle with stripped wire ends makes installation of disconnect and receptacle
quick and easy. This unit provides a significantly lower "installed cost" to the contractor
when compared to installing a standard disconnect and separate GFCI receptacle with
"while in use" cover to comply with the new NEC code change.
Additional features and benefits include: Convenient electrical power cord channel
w/retaining clip for easy and safe use of portable tools; Large wiring compartment for
both disconnect switch and receptacle; Angled receptacle mounting to eliminate the
possibility of crushing portable electrical plugs when closing "while in use” cover;
Attractive side opening cover design for ease of installation; Ultra UV powder coating.
Specifications:
• 60 amp, non-fused, pullout type
• Pre-wired 15A, 125V GFCI
receptacle included
• 240 volt, single phase
• 10,000 amp rated
MARS
NO.
DESCRIPTION
80308 Pullout disconnect
W/GFCI receptacle
The largest selection of motors, components and accessories for the HVAC/R Industry
• NEMA 3R & UL rainproof
• UL & CUL approved
• Rated for 10HP @ 240 volts
• Meets NEC #210.63 & #406.8(B)(1)
• Multiple patents pending
STD.
PACK
CASE
QTY
66
80308
Convenient electrical power
cord channel w/retaining clip
for easy and safe use of
portable tools
Easy to remove
concentric
knockouts &
secure locking
mechanism
Patented “Finger Safe”
Pullout section
prevents accidental
contact with electrodes
SI–7